{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,30]],"date-time":"2026-10-30T21:32:26Z","timestamp":1793395946316,"version":"4.5.0"},"reference-count":30,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2013,7,3]],"date-time":"2013-07-03T00:00:00Z","timestamp":1372809600000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/2.0"},{"start":{"date-parts":[[2013,7,3]],"date-time":"2013-07-03T00:00:00Z","timestamp":1372809600000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/2.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BioMed Eng OnLine"],"published-print":{"date-parts":[[2013,12]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Purpose<\/jats:title>\n                    <jats:p>Nondegradable steel-and titanium-based implants are commonly used in orthopedic surgery. Although they provide maximal stability, they are also associated with interference on imaging modalities, may induce stress shielding, and additional explantation procedures may be necessary. Alternatively, degradable polymer implants are mechanically weaker and induce foreign body reactions. Degradable magnesium-based stents are currently being investigated in clinical trials for use in cardiovascular medicine. The magnesium alloy MgYREZr demonstrates good biocompatibility and osteoconductive properties. The aim of this prospective, randomized, clinical pilot trial was to determine if magnesium-based MgYREZr screws are equivalent to standard titanium screws for fixation during chevron osteotomy in patients with a mild hallux valgus.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>Patients (n=26) were randomly assigned to undergo osteosynthesis using either titanium or degradable magnesium-based implants of the same design. The 6 month follow-up period included clinical, laboratory, and radiographic assessments.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>No significant differences were found in terms of the American Orthopaedic Foot and Ankle Society (AOFAS) score for hallux, visual analog scale for pain assessment, or range of motion (ROM) of the first metatarsophalangeal joint (MTPJ). No foreign body reactions, osteolysis, or systemic inflammatory reactions were detected. The groups were not significantly different in terms of radiographic or laboratory results.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion<\/jats:title>\n                    <jats:p>The radiographic and clinical results of this prospective controlled study demonstrate that degradable magnesium-based screws are equivalent to titanium screws for the treatment of mild hallux valgus deformities.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1186\/1475-925x-12-62","type":"journal-article","created":{"date-parts":[[2013,7,2]],"date-time":"2013-07-02T22:28:43Z","timestamp":1372804123000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":474,"title":["Biodegradable magnesium-based screw clinically equivalent to titanium screw in hallux valgus surgery: short term results of the first prospective, randomized, controlled clinical pilot study"],"prefix":"10.1186","volume":"12","author":[{"given":"Henning","family":"Windhagen","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kerstin","family":"Radtke","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Andreas","family":"Weizbauer","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Julia","family":"Diekmann","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yvonne","family":"Noll","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ulrike","family":"Kreimeyer","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Robert","family":"Schavan","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Christina","family":"Stukenborg-Colsman","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hazibullah","family":"Waizy","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2013,7,3]]},"reference":[{"key":"672_CR1","doi-asserted-by":"publisher","first-page":"39","DOI":"10.1007\/s10853-012-6572-2","volume":"48","author":"H Waizy","year":"2013","unstructured":"Waizy H, Seitz JM, Reifenrath J, Weizbauer A, Bach FW, Meyer-Lindenberg A, Denkena B, Windhagen H: Biodegradable magnesium implants for orthopedic applications. J Mater Sci 2013, 48: 39\u201350. 10.1007\/s10853-012-6572-2","journal-title":"J Mater Sci"},{"key":"672_CR2","doi-asserted-by":"publisher","first-page":"589","DOI":"10.1097\/00006534-199410000-00004","volume":"94","author":"PK Sullivan","year":"1994","unstructured":"Sullivan PK, Smith JF, Rozzelle AA: Cranio-orbital reconstruction: safety and image quality of metallic implants on CT and MRI scanning. Plast Reconstr Surg 1994, 94: 589\u2013596. 10.1097\/00006534-199410000-00004","journal-title":"Plast Reconstr Surg"},{"key":"672_CR3","doi-asserted-by":"publisher","first-page":"1581","DOI":"10.1007\/s10856-008-3372-y","volume":"19","author":"N Sumitomo","year":"2008","unstructured":"Sumitomo N, Noritake K, Hattori T, Morikawa K, Niwa S, Sato K, Niinomi M: Experiment study on fracture fixation with low rigidity titanium alloy: plate fixation of tibia fracture model in rabbit. J Mater Sci Mater Med 2008, 19: 1581\u20131586. 10.1007\/s10856-008-3372-y","journal-title":"J Mater Sci Mater Med"},{"key":"672_CR4","doi-asserted-by":"publisher","first-page":"1728","DOI":"10.1016\/j.biomaterials.2005.10.003","volume":"27","author":"MP Staiger","year":"2006","unstructured":"Staiger MP, Pietak AM, Huadmai J, Dias G: Magnesium and its alloys as orthopedic biomaterials: a review. Biomaterials 2006, 27: 1728\u20131734. 10.1016\/j.biomaterials.2005.10.003","journal-title":"Biomaterials"},{"key":"672_CR5","doi-asserted-by":"crossref","first-page":"263","DOI":"10.1097\/00003086-199212000-00036","volume":"285","author":"OM Bostman","year":"1992","unstructured":"Bostman OM, Paivarinta U, Partio E, Manninen M, Vasenius J, Majola A, Rokkanen P: The tissue-implant interface during degradation of absorbable polyglycolide fracture fixation screws in the rabbit femur. Clin Orthop Relat Res 1992, 285: 263\u2013272.","journal-title":"Clin Orthop Relat Res"},{"key":"672_CR6","doi-asserted-by":"publisher","first-page":"2464","DOI":"10.1001\/jama.1938.02790530018007","volume":"111","author":"E McBride","year":"1938","unstructured":"McBride E: Absorbable metal in bone surgery. J Am Med Assoc 1938, 111: 2464\u20132467. 10.1001\/jama.1938.02790530018007","journal-title":"J Am Med Assoc"},{"key":"672_CR7","doi-asserted-by":"publisher","first-page":"128","DOI":"10.1111\/j.1527-5299.2006.04668.x","volume":"4","author":"D Bose","year":"2006","unstructured":"Bose D, Eggebrecht H, Haude M, Schmermund A, Erbel R: First absorbable metal stent implantation in human coronary arteries. Am Heart Hosp J 2006, 4: 128\u2013130. 10.1111\/j.1527-5299.2006.04668.x","journal-title":"Am Heart Hosp J"},{"key":"672_CR8","volume-title":"J Biomater Appl","author":"H Waizy","year":"2013","unstructured":"Waizy H, Diekmann J, Weizbauer A, Reifenrath J, Bartsch I, Neubert V, Schavan R, Windhagen H: In vivo study of a biodegradable orthopedic screw (MgYREZr-alloy) in a rabbit model for up to 12 months. J Biomater Appl 2013. 10.1177\/0885328212472215"},{"key":"672_CR9","doi-asserted-by":"crossref","first-page":"25","DOI":"10.1097\/00003086-198106000-00007","volume":"157","author":"DW Austin","year":"1981","unstructured":"Austin DW, Leventen EO: A new osteotomy for hallux valgus: a horizontally directed \"V\" displacement osteotomy of the metatarsal head for hallux valgus and primus varus. Clin Orthop Relat Res 1981, 157: 25\u201330.","journal-title":"Clin Orthop Relat Res"},{"key":"672_CR10","doi-asserted-by":"crossref","first-page":"31","DOI":"10.1097\/00003086-198106000-00008","volume":"157","author":"RA Mann","year":"1981","unstructured":"Mann RA, Coughlin MJ: Hallux valgus-etiology, anatomy, treatment and surgical considerations. Clin Orthop Relat Res 1981, 157: 31\u201341.","journal-title":"Clin Orthop Relat Res"},{"key":"672_CR11","doi-asserted-by":"publisher","first-page":"243","DOI":"10.7547\/87507315-84-5-243","volume":"84","author":"MS Downey","year":"1994","unstructured":"Downey MS: Complications of the Kalish bunionectomy. J Am Podiatr Med Assoc 1994, 84: 243\u2013249.","journal-title":"J Am Podiatr Med Assoc"},{"key":"672_CR12","doi-asserted-by":"publisher","first-page":"89","DOI":"10.3113\/FAI.2007.0016","volume":"28","author":"AA Faraj","year":"2007","unstructured":"Faraj AA, Naraen A, Twigg P: A comparative study of wire fixation and screw fixation in arthrodesis for the correction of hallux rigidus using an in vitro biomechanical model. Foot Ankle Int 2007, 28: 89\u201391. 10.3113\/FAI.2007.0016","journal-title":"Foot Ankle Int"},{"key":"672_CR13","doi-asserted-by":"publisher","first-page":"415","DOI":"10.1016\/S0266-7681(05)80265-7","volume":"17","author":"TJ Herbert","year":"1992","unstructured":"Herbert TJ, Fisher WE, Leicester AW: The Herbert bone screw: a ten year perspective. J Hand Surg Br 1992, 17: 415\u2013419. 10.1016\/S0266-7681(05)80265-7","journal-title":"J Hand Surg Br"},{"key":"672_CR14","doi-asserted-by":"publisher","first-page":"46","DOI":"10.1007\/s00064-010-0005-7","volume":"23","author":"H Waizy","year":"2011","unstructured":"Waizy H, Stukenborg-Colsman C, Abbara-Czardybon M, Emmerich J, Windhagen H, Frank D: A special soft tissue procedure for treatment of hallux valgus. Oper Orthop Traumatol 2011, 23: 46\u201351. 10.1007\/s00064-010-0005-7","journal-title":"Oper Orthop Traumatol"},{"key":"672_CR15","doi-asserted-by":"crossref","first-page":"494","DOI":"10.2106\/00004623-200303000-00015","volume":"85A","author":"W Schneider","year":"2003","unstructured":"Schneider W, Csepan R, Knahr K: Reproducibility of the radiographic metatarsophalangeal angle in hallux surgery. J Bone Joint Surg Am 2003, 85A: 494\u2013499.","journal-title":"J Bone Joint Surg Am"},{"key":"672_CR16","doi-asserted-by":"publisher","first-page":"759","DOI":"10.3113\/FAI.2007.0759","volume":"28","author":"MJ Coughlin","year":"2007","unstructured":"Coughlin MJ, Jones CP: Hallux valgus: demographics, etiology, and radiographic assessment. Foot Ankle Int 2007, 28: 759\u2013777. 10.3113\/FAI.2007.0759","journal-title":"Foot Ankle Int"},{"key":"672_CR17","doi-asserted-by":"publisher","first-page":"315","DOI":"10.1007\/s00113-012-2159-2","volume":"115","author":"C Krettek","year":"2012","unstructured":"Krettek C, Muller C, Meller R, Jagodzinski M, Hildebrand F, Gaulke R: Is routine implant removal after trauma surgery sensible? Unfallchirurg 2012, 115: 315\u2013322. 10.1007\/s00113-012-2159-2","journal-title":"Unfallchirurg"},{"key":"672_CR18","doi-asserted-by":"publisher","first-page":"222","DOI":"10.1097\/01.blo.0000130208.90879.67","volume":"423","author":"T Gosling","year":"2004","unstructured":"Gosling T, Hufner T, Hankemeier S, Zelle BA, Muller-Heine A, Krettek C: Femoral nail removal should be restricted in asymptomatic patients. Clin Orthop Relat Res 2004, 423: 222\u2013226.","journal-title":"Clin Orthop Relat Res"},{"key":"672_CR19","doi-asserted-by":"crossref","first-page":"932","DOI":"10.2106\/00004623-199606000-00018","volume":"78","author":"MJ Coughlin","year":"1996","unstructured":"Coughlin MJ: Hallux valgus. J Bone Joint Surg Am 1996, 78: 932\u2013966.","journal-title":"J Bone Joint Surg Am"},{"key":"672_CR20","first-page":"512","volume":"31","author":"JR Hanft","year":"1992","unstructured":"Hanft JR, Kashuk KB, Bonner AC, Toney M, Schabler J: Rigid internal fixation of the Austin\/Chevron osteotomy with Herbert screw fixation: a retrospective study. J Foot Surg 1992, 31: 512\u2013518.","journal-title":"J Foot Surg"},{"key":"672_CR21","doi-asserted-by":"publisher","first-page":"203","DOI":"10.1053\/j.jfas.2005.02.003","volume":"44","author":"DS Caminear","year":"2005","unstructured":"Caminear DS, Pavlovich R Jr, Pietrzak WS: Fixation of the chevron osteotomy with an absorbable copolymer pin for treatment of hallux valgus deformity. J Foot Ankle Surg 2005, 44: 203\u2013210. 10.1053\/j.jfas.2005.02.003","journal-title":"J Foot Ankle Surg"},{"key":"672_CR22","doi-asserted-by":"publisher","first-page":"346","DOI":"10.1177\/107110079501600606","volume":"16","author":"HN Small","year":"1995","unstructured":"Small HN, Braly WG, Tullos HS: Fixation of the Chevron osteotomy utilizing absorbable polydioxanon pins. Foot Ankle Int 1995, 16: 346\u2013350. 10.1177\/107110079501600606","journal-title":"Foot Ankle Int"},{"key":"672_CR23","doi-asserted-by":"crossref","first-page":"1510","DOI":"10.2106\/00004623-199710000-00008","volume":"79","author":"LH Gill","year":"1997","unstructured":"Gill LH, Martin DF, Coumas JM, Kiebzak GM: Fixation with bioabsorbable pins in chevron bunionectomy. J Bone Joint Surg Am 1997, 79: 1510\u20131518.","journal-title":"J Bone Joint Surg Am"},{"key":"672_CR24","doi-asserted-by":"publisher","first-page":"12","DOI":"10.1186\/1475-925X-11-12","volume":"11","author":"H Waizy","year":"2012","unstructured":"Waizy H, Weizbauer A, Modrejewski C, Witte F, Windhagen H, Lucas A, Kieke M, Denkena B, Behrens P, Meyer-Lindenberg A, Bach F-W, Thorey F: In vitro corrosion of ZEK100 plates in Hank's Balanced Salt Solution. Biomed Eng Online 2012, 11: 12. 10.1186\/1475-925X-11-12","journal-title":"Biomed Eng Online"},{"key":"672_CR25","doi-asserted-by":"publisher","first-page":"649","DOI":"10.1007\/s10856-011-4544-8","volume":"23","author":"H Waizy","year":"2012","unstructured":"Waizy H, Weizbauer A, Maibaum M, Witte F, Windhagen H, Lucas A, Denkena B, Meyer-Lindenberg A, Thorey F: Biomechanical characterisation of a degradable magnesium-based (MgCa0.8) screw. J Mater Sci Mater Med 2012, 23: 649\u2013655. 10.1007\/s10856-011-4544-8","journal-title":"J Mater Sci Mater Med"},{"key":"672_CR26","doi-asserted-by":"publisher","first-page":"1421","DOI":"10.1016\/j.actbio.2010.10.031","volume":"7","author":"N Erdmann","year":"2011","unstructured":"Erdmann N, Angrisani N, Reifenrath J, Lucas A, Thorey F, Bormann D, Meyer-Lindenberg A: Biomechanical testing and degradation analysis of MgCa0.8 alloy screws: a comparative in vivo study in rabbits. Acta Biomater 2011, 7: 1421\u20131428. 10.1016\/j.actbio.2010.10.031","journal-title":"Acta Biomater"},{"key":"672_CR27","volume-title":"Acta Biomater","author":"J Kuhlmann","year":"2012","unstructured":"Kuhlmann J, Bartsch I, Willbold E, Schuchardt S, Holz O, Hort N, Hoche D, Heineman WR, Witte F: Fast escape of hydrogen from gas cavities around corroding magnesium implants. Acta Biomater 2012. 10.1016\/j.actbio.2012.10.008"},{"key":"672_CR28","doi-asserted-by":"publisher","first-page":"1301","DOI":"10.1016\/S0142-9612(99)00235-5","volume":"21","author":"N Hallab","year":"2000","unstructured":"Hallab N, Jacobs JJ, Black J: Hypersensitivity to metallic biomaterials: a review of leukocyte migration inhibition assays. Biomaterials 2000, 21: 1301\u20131314. 10.1016\/S0142-9612(99)00235-5","journal-title":"Biomaterials"},{"key":"672_CR29","doi-asserted-by":"publisher","first-page":"1041","DOI":"10.1002\/jbm.a.31713","volume":"86","author":"F Witte","year":"2008","unstructured":"Witte F, Abeln I, Switzer E, Kaese V, Meyer-Lindenberg A, Windhagen H: Evaluation of the skin sensitizing potential of biodegradable magnesium alloys. J Biomed Mater Res A 2008, 86: 1041\u20131047.","journal-title":"J Biomed Mater Res A"},{"key":"672_CR30","doi-asserted-by":"publisher","first-page":"153","DOI":"10.1016\/j.jmbbm.2012.02.002","volume":"9","author":"X Zhang","year":"2012","unstructured":"Zhang X, Yuan G, Niu J, Fu P, Ding W: Microstructure, mechanical properties, biocorrosion behavior, and cytotoxicity of as-extruded Mg-Nd-Zn-Zr alloy with different extrusion ratios. J Mech Behav Biomed Mater 2012, 9: 153\u2013162.","journal-title":"J Mech Behav Biomed Mater"}],"updated-by":[{"DOI":"10.1186\/s12938-020-00818-8","type":"correction","label":"Correction","source":"publisher","updated":{"date-parts":[[2020,11,23]],"date-time":"2020-11-23T00:00:00Z","timestamp":1606089600000}}],"container-title":["BioMedical Engineering OnLine"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1186\/1475-925X-12-62.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1186\/1475-925X-12-62\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/1475-925X-12-62.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,7,2]],"date-time":"2023-07-02T17:07:29Z","timestamp":1688317649000},"score":1,"resource":{"primary":{"URL":"https:\/\/biomedical-engineering-online.biomedcentral.com\/articles\/10.1186\/1475-925X-12-62"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2013,7,3]]},"references-count":30,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2013,12]]}},"alternative-id":["672"],"URL":"https:\/\/doi.org\/10.1186\/1475-925x-12-62","relation":{},"ISSN":["1475-925X"],"issn-type":[{"value":"1475-925X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2013,7,3]]},"assertion":[{"value":"8 April 2013","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"25 June 2013","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"3 July 2013","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"23 November 2020","order":4,"name":"change_date","label":"Change Date","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"Correction","order":5,"name":"change_type","label":"Change Type","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"An amendment to this paper has been published and can be accessed via the original article.","order":6,"name":"change_details","label":"Change Details","group":{"name":"ArticleHistory","label":"Article History"}}],"article-number":"62"}}