{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,18]],"date-time":"2026-08-18T02:21:12Z","timestamp":1787019672631,"version":"build-2736575974"},"reference-count":37,"publisher":"Elsevier BV","issue":"1","license":[{"start":{"date-parts":[[2014,12,1]],"date-time":"2014-12-01T00:00:00Z","timestamp":1417392000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2014,12,1]],"date-time":"2014-12-01T00:00:00Z","timestamp":1417392000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2014,6,18]],"date-time":"2014-06-18T00:00:00Z","timestamp":1403049600000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/2.0\/"}],"content-domain":{"domain":["elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Journal of Cardiovascular Magnetic Resonance"],"published-print":{"date-parts":[[2014,12]]},"DOI":"10.1186\/1532-429x-16-42","type":"journal-article","created":{"date-parts":[[2014,6,18]],"date-time":"2014-06-18T19:32:28Z","timestamp":1403119948000},"page":"42","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":52,"title":["Towards highly accelerated Cartesian time-resolved 3D flow cardiovascular magnetic resonance in the clinical setting"],"prefix":"10.1016","volume":"16","author":[{"given":"Daniel","family":"Giese","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"James","family":"Wong","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Gerald F","family":"Greil","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Martin","family":"Buehrer","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tobias","family":"Schaeffter","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sebastian","family":"Kozerke","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1186\/1532-429X-16-42_bib1","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1186\/1532-429X-13-7","article-title":"Comprehensive 4D velocity mapping of the heart and great vessels by cardiovascular magnetic resonance","volume":"13","author":"Markl","year":"2011","journal-title":"J. Cardiovasc. Magn. Reson"},{"key":"10.1186\/1532-429X-16-42_bib2","doi-asserted-by":"crossref","first-page":"677","DOI":"10.1002\/jmri.22280","article-title":"Flow\u2010sensitive four\u2010dimensional cine magnetic resonance imaging for offline blood flow quantification in multiple vessels: a validation study","volume":"32","author":"Nordmeyer","year":"2010","journal-title":"J. Magn. Reson. Imaging"},{"key":"10.1186\/1532-429X-16-42_bib3","doi-asserted-by":"crossref","first-page":"1575","DOI":"10.1002\/mrm.22353","article-title":"Estimation of global aortic pulse wave velocity by flow\u2010sensitive 4D MRI","volume":"63","author":"Markl","year":"2010","journal-title":"Magn. Reson. Med"},{"key":"10.1186\/1532-429X-16-42_bib4","doi-asserted-by":"crossref","first-page":"872","DOI":"10.1002\/mrm.1116","article-title":"Estimation of relative cardiovascular pressures using time\u2010resolved three\u2010dimensional phase contrast MRI","volume":"45","author":"Ebbers","year":"2001","journal-title":"Magn. Reson. Med"},{"key":"10.1186\/1532-429X-16-42_bib5","doi-asserted-by":"crossref","first-page":"1218","DOI":"10.1002\/mrm.21778","article-title":"Quantitative 2D and 3D phase contrast MRI: optimized analysis of blood flow and vessel wall parameters","volume":"60","author":"Stalder","year":"2008","journal-title":"Magn. Reson. Med"},{"key":"10.1186\/1532-429X-16-42_bib6","doi-asserted-by":"crossref","first-page":"128","DOI":"10.1002\/jmri.23610","article-title":"Assessment of the accuracy of MRI wall shear stress estimation using numerical simulations","volume":"36","author":"Petersson","year":"2012","journal-title":"J. Magn. Reson. Imaging"},{"key":"10.1186\/1532-429X-16-42_bib7","doi-asserted-by":"crossref","first-page":"345","DOI":"10.1016\/j.mri.2004.01.002","article-title":"Three-dimensional phase contrast velocity mapping acquisition improves wall shear stress estimation in vivo","volume":"22","author":"Wu","year":"2004","journal-title":"Magn. Reson. Imaging"},{"key":"10.1186\/1532-429X-16-42_bib8","doi-asserted-by":"crossref","first-page":"850","DOI":"10.1002\/mrm.21022","article-title":"Quantification of intravoxel velocity standard deviation and turbulence intensity by generalizing phase\u2010contrast MRI","volume":"56","author":"Dyverfeldt","year":"2006","journal-title":"Magn. Reson. Med"},{"key":"10.1186\/1532-429X-16-42_bib9","article-title":"Bayesian multipoint velocity encoding for concurrent flow and turbulence mapping","author":"Binter","year":"2012","journal-title":"Magn. Reson. Med"},{"key":"10.1186\/1532-429X-16-42_bib10","doi-asserted-by":"crossref","first-page":"1031","DOI":"10.1002\/mrm.10611","article-title":"kt BLAST and kt SENSE: dynamic MRI with high frame rate exploiting spatiotemporal correlations","volume":"50","author":"Tsao","year":"2003","journal-title":"Magn. Reson. Med"},{"key":"10.1186\/1532-429X-16-42_bib11","doi-asserted-by":"crossref","first-page":"1430","DOI":"10.1002\/mrm.20730","article-title":"Accelerating cine phase-contrast flow measurements using k-t BLAST and k-t SENSE","volume":"54","author":"Baltes","year":"2005","journal-title":"Magn. Reson. Med"},{"key":"10.1186\/1532-429X-16-42_bib12","doi-asserted-by":"crossref","first-page":"1226","DOI":"10.1002\/jmri.21561","article-title":"Parallel MRI with extended and averaged GRAPPA kernels (PEAK-GRAPPA): optimized spatiotemporal dynamic imaging","volume":"28","author":"Jung","year":"2008","journal-title":"J. Magn. Reson. Imaging"},{"key":"10.1186\/1532-429X-16-42_bib13","doi-asserted-by":"crossref","first-page":"15","DOI":"10.1016\/j.ejrad.2009.06.009","article-title":"Accelerated time-resolved three-dimensional MR velocity mapping of blood flow patterns in the aorta using SENSE and kt BLAST","volume":"75","author":"Stadlbauer","year":"2010","journal-title":"Eur. J. Radiol"},{"key":"10.1186\/1532-429X-16-42_bib14","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1186\/1532-429X-13-55","article-title":"Quantification and visualization of cardiovascular 4D velocity mapping accelerated with parallel imaging or kt BLAST: head to head comparison and validation at 1.5\u00a0T and 3\u00a0T","volume":"13","author":"Carlsson","year":"2011","journal-title":"J. Cardiovasc. Magn. Reson"},{"key":"10.1186\/1532-429X-16-42_bib15","article-title":"k\u2010t GRAPPA accelerated four\u2010dimensional flow MRI in the aorta: effect on scan time, image quality, and quantification of flow and wall shear stress","author":"Schnell","year":"2013","journal-title":"Magn. Reson. Med"},{"key":"10.1186\/1532-429X-16-42_bib16","doi-asserted-by":"crossref","first-page":"817","DOI":"10.1002\/jmri.21706","article-title":"Accelerated phase\u2010contrast MR imaging: comparison of k\u2010t BLAST with SENSE and doppler ultrasound for velocity and flow measurements in the aorta","volume":"29","author":"Stadlbauer","year":"2009","journal-title":"J. Magn. Reson. Imaging"},{"key":"10.1186\/1532-429X-16-42_bib17","doi-asserted-by":"crossref","first-page":"53","DOI":"10.1002\/mrm.24431","article-title":"Sparsity transform k\u2010t principal component analysis for accelerating cine three\u2010dimensional flow measurements","volume":"70","author":"Knobloch","year":"2012","journal-title":"Magn. Reson. Med"},{"key":"10.1186\/1532-429X-16-42_bib18","doi-asserted-by":"crossref","first-page":"87","DOI":"10.1148\/radiol.12120055","article-title":"Evaluation of valvular insufficiency and shunts with parallel-imaging compressed-sensing 4D phase-contrast MR imaging with stereoscopic 3D velocity-fusion volume-rendered visualization","volume":"265","author":"Hsiao","year":"2012","journal-title":"Radiology"},{"key":"10.1186\/1532-429X-16-42_bib19","doi-asserted-by":"crossref","first-page":"819","DOI":"10.1097\/RLI.0b013e31829a4f2f","article-title":"Quantification of thoracic blood flow using volumetric magnetic resonance imaging with radial velocity encoding","volume":"48","author":"Frydrychowicz","year":"2013","journal-title":"Invest Radiol"},{"key":"10.1186\/1532-429X-16-42_bib20","doi-asserted-by":"crossref","first-page":"2172","DOI":"10.1007\/s00330-005-2829-3","article-title":"Applications of phase-contrast flow and velocity imaging in cardiovascular MRI","volume":"15","author":"Gatehouse","year":"2005","journal-title":"Eur. Radiol"},{"key":"10.1186\/1532-429X-16-42_bib21","doi-asserted-by":"crossref","first-page":"24","DOI":"10.1016\/j.ejrad.2011.01.094","article-title":"Four-dimensional phase contrast magnetic resonance angiography: potential clinical applications","volume":"80","author":"Frydrychowicz","year":"2011","journal-title":"Eur. J. Radiol"},{"key":"10.1186\/1532-429X-16-42_bib22","doi-asserted-by":"crossref","first-page":"792","DOI":"10.1148\/radiol.2492080146","article-title":"Mitral valve and tricuspid valve blood flow: accurate quantification with 3D velocity-encoded MR imaging with retrospective valve tracking1","volume":"249","author":"Westenberg","year":"2008","journal-title":"Radiology"},{"key":"10.1186\/1532-429X-16-42_bib23","doi-asserted-by":"crossref","first-page":"706","DOI":"10.1002\/mrm.22052","article-title":"k-t PCA: temporally constrained k-t BLAST reconstruction using principal component analysis","volume":"62","author":"Pedersen","year":"2009","journal-title":"Magn. Reson. Med"},{"key":"10.1186\/1532-429X-16-42_bib24","doi-asserted-by":"crossref","first-page":"405","DOI":"10.1002\/jmri.1880010404","article-title":"Encoding strategies for three-direction phase-contrast MR imaging of flow","volume":"1","author":"Pelc","year":"1991","journal-title":"J. Magn. Reson. Imaging"},{"key":"10.1186\/1532-429X-16-42_bib25","doi-asserted-by":"crossref","first-page":"361","DOI":"10.1081\/JCMR-200053538","article-title":"Blood flow quantification in adults by phase-contrast MRI combined with SENSE-a validation study","volume":"7","author":"Beerbaum","year":"2005","journal-title":"J. Cardiovasc. Magn. Reson"},{"key":"10.1186\/1532-429X-16-42_bib26","doi-asserted-by":"crossref","first-page":"300","DOI":"10.1002\/mrm.1910390218","article-title":"Concomitant gradient terms in phase contrast MR: analysis and correction","volume":"39","author":"Bernstein","year":"1998","journal-title":"Magn. Reson. Med"},{"key":"10.1186\/1532-429X-16-42_bib27","doi-asserted-by":"crossref","first-page":"521","DOI":"10.1002\/jmri.1880030315","article-title":"Semiautomated method for noise reduction and background phase error correction in MR phase velocity data","volume":"3","author":"Walker","year":"1993","journal-title":"J. Magn. Reson. Imaging"},{"key":"10.1186\/1532-429X-16-42_bib28","doi-asserted-by":"crossref","first-page":"73","DOI":"10.1002\/jmri.20361","article-title":"Correction of phase offset errors in main pulmonary artery flow quantification","volume":"22","author":"Lankhaar","year":"2005","journal-title":"J. Magn. Reson. Imaging"},{"key":"10.1186\/1532-429X-16-42_bib29","doi-asserted-by":"crossref","first-page":"25","DOI":"10.1186\/1532-429X-14-25","article-title":"Systemic-to-pulmonary collateral flow in patients with palliated univentricular heart physiology: measurement using cardiovascular magnetic resonance 4D velocity acquisition","volume":"14","author":"Valverde","year":"2012","journal-title":"J. Cardiovasc. Magn. Reson"},{"key":"10.1186\/1532-429X-16-42_bib30","doi-asserted-by":"crossref","first-page":"984","DOI":"10.1002\/mrm.22090","article-title":"Four-dimensional (4D) flow of the whole heart and great vessels using real-time respiratory self-gating","volume":"62","author":"Uribe","year":"2009","journal-title":"Magn. Reson. Med"},{"key":"10.1186\/1532-429X-16-42_bib31","doi-asserted-by":"crossref","first-page":"5","DOI":"10.1186\/1532-429X-12-5","article-title":"Flow measurement by cardiovascular magnetic resonance: a multi-centre multi-vendor study of background phase offset errors that can compromise the accuracy of derived regurgitant or shunt flow measurements","volume":"12","author":"Gatehouse","year":"2010","journal-title":"J. Cardiovasc. Magn. Reson"},{"key":"10.1186\/1532-429X-16-42_bib32","doi-asserted-by":"crossref","first-page":"1294","DOI":"10.1002\/mrm.23111","article-title":"Analysis and correction of background velocity offsets in phase contrast flow measurements using magnetic field monitoring","volume":"67","author":"Giese","year":"2012","journal-title":"Magn. Reson. Med"},{"key":"10.1186\/1532-429X-16-42_bib33","doi-asserted-by":"crossref","first-page":"82","DOI":"10.1002\/mrm.1910300113","article-title":"Analysis of systematic and random error in MR volumetric flow measurements","volume":"30","author":"Wolf","year":"1993","journal-title":"Magn. Reson. Med"},{"key":"10.1186\/1532-429X-16-42_bib34","doi-asserted-by":"crossref","first-page":"469","DOI":"10.1097\/00004728-199405000-00023","article-title":"Cine phase-contrast MR flow measurements: improved precision using an automated method of vessel detection","volume":"18","author":"Burkart","year":"1994","journal-title":"J. Comput. Assist. Tomogr"},{"key":"10.1186\/1532-429X-16-42_bib35","doi-asserted-by":"crossref","first-page":"420","DOI":"10.1002\/mrm.1910150308","article-title":"Signal\u2010to\u2010noise in phase angle reconstruction: dynamic range extension using phase reference offsets","volume":"15","author":"Conturo","year":"1990","journal-title":"Magn. Reson. Med"},{"key":"10.1186\/1532-429X-16-42_bib36","doi-asserted-by":"crossref","first-page":"122","DOI":"10.1002\/mrm.1910330119","article-title":"Three-point phase-contrast velocity measurements with increased velocity-to-noise ratio","volume":"33","author":"Lee","year":"1995","journal-title":"Magn. Reson. Med"},{"key":"10.1186\/1532-429X-16-42_bib37","doi-asserted-by":"crossref","first-page":"838","DOI":"10.1002\/jmri.1880070510","article-title":"Multistep phase difference phase contrast imaging","volume":"7","author":"Lamothe","year":"1997","journal-title":"J. Magn. Reson. Imaging"}],"container-title":["Journal of Cardiovascular Magnetic Resonance"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1097664723001151?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1097664723001151?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1186\/1532-429X-16-42.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,22]],"date-time":"2025-10-22T01:00:43Z","timestamp":1761094843000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S1097664723001151"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2014,12]]},"references-count":37,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2014,12]]}},"alternative-id":["S1097664723001151"],"URL":"https:\/\/doi.org\/10.1186\/1532-429x-16-42","relation":{},"ISSN":["1097-6647"],"issn-type":[{"value":"1097-6647","type":"print"}],"subject":[],"published":{"date-parts":[[2014,12]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Towards highly accelerated Cartesian time-resolved 3D flow cardiovascular magnetic resonance in the clinical setting","name":"articletitle","label":"Article Title"},{"value":"Journal of Cardiovascular Magnetic Resonance","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1186\/1532-429X-16-42","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"Copyright \u00a9 2014 THE AUTHORS. Published by Elsevier Inc on behalf of the Society for Cardiovascular Magnetic Resonance","name":"copyright","label":"Copyright"}],"article-number":"42"}}