{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,28]],"date-time":"2025-10-28T14:52:47Z","timestamp":1761663167134},"reference-count":18,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2013,4,17]],"date-time":"2013-04-17T00:00:00Z","timestamp":1366156800000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/2.0"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J Image Video Proc"],"published-print":{"date-parts":[[2013,12]]},"DOI":"10.1186\/1687-5281-2013-19","type":"journal-article","created":{"date-parts":[[2013,4,17]],"date-time":"2013-04-17T10:32:18Z","timestamp":1366194738000},"source":"Crossref","is-referenced-by-count":12,"title":["LBPV descriptors-based automatic ACR\/BIRADS classification approach"],"prefix":"10.1186","volume":"2013","author":[{"given":"Alima Damak","family":"Masmoudi","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Norhen Gargouri","family":"Ben Ayed","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Dorra Sellami","family":"Masmoudi","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Riad","family":"Abid","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2013,4,17]]},"reference":[{"key":"56_CR1","doi-asserted-by":"publisher","first-page":"909","DOI":"10.1088\/0031-9155\/41\/5\/007","volume":"41","author":"JW Byng","year":"1996","unstructured":"Byng JW, Boyd NF, Fishell E, Jong RA, Yaffe MJ: Automated analysis of mammographic densities. Phys. Med. Biol 1996, 41: 909-923. 10.1088\/0031-9155\/41\/5\/007","journal-title":"Phys. Med. Biol"},{"key":"56_CR2","doi-asserted-by":"publisher","first-page":"192","DOI":"10.1148\/radiology.219.1.r01ap16192","volume":"219","author":"RL Birdwell","year":"2001","unstructured":"Birdwell RL, Ikeda DM, O\u2019Shaughnessy KD, Sickles EA: Mammographic characteristics of 115 missed cancers later detected with screening mammography and the potential utility of computer-aided detection. Radiology 2001, 219: 192-202.","journal-title":"Radiology"},{"key":"56_CR3","doi-asserted-by":"publisher","first-page":"781","DOI":"10.1148\/radiol.2203001282","volume":"220","author":"TW Freer","year":"2001","unstructured":"Freer TW, Ulissey MJ: Screening mammography with computeraided detection: prospective study of 01286 patients in a community breast center. Radiology 2001, 220: 781-786. 10.1148\/radiol.2203001282","journal-title":"Radiology"},{"key":"56_CR4","doi-asserted-by":"publisher","DOI":"10.1055\/b-002-59230","volume-title":"Breast Cancer\u2014The Art and Science of Early Detection With Mammography","author":"L Tabar","year":"2005","unstructured":"Tabar L, Tot T, Dean PB: Breast Cancer\u2014The Art and Science of Early Detection With Mammography. Germany: Georg Thieme Verlag, Stuttgart; 2005."},{"key":"56_CR5","doi-asserted-by":"publisher","first-page":"133","DOI":"10.1053\/crad.2002.1131","volume":"58","author":"WT Ho","year":"2003","unstructured":"Ho WT, Lam PWT: Clinical performance of computer-assisted detection (CAD) system in detecting carcinoma in breasts of different densities. Clin. Radiol 2003, 58: 133-136. 10.1053\/crad.2002.1131","journal-title":"Clin. Radiol"},{"key":"56_CR6","doi-asserted-by":"publisher","first-page":"670","DOI":"10.1093\/jnci\/87.9.670","volume":"87","author":"NF Boyd","year":"1995","unstructured":"Boyd NF, Byng JW, Jong RA, Fishell EK, Little LE, Miller AB, Lockwood GA, Tritchler DL, Yaffe MJ: Quantitative classification of mammographic densities and breast cancer risk: results from the Canadian national breast screening study. J. Nat. Cancer Inst 1995, 87: 670-675. 10.1093\/jnci\/87.9.670","journal-title":"J. Nat. Cancer Inst"},{"key":"56_CR7","volume-title":"Illustrated Breast Imaging Reporting and Data System BIRADS","author":"American College of Radiology","year":"1998","unstructured":"American College of Radiology: Illustrated Breast Imaging Reporting and Data System BIRADS. Philadelphia, PA: American College of Radiology; 1998."},{"key":"56_CR8","doi-asserted-by":"publisher","first-page":"2486","DOI":"10.1002\/1097-0142(197605)37:5<2486::AID-CNCR2820370542>3.0.CO;2-8","volume":"37","author":"JN Wolfe","year":"1976","unstructured":"Wolfe JN: Risk for breast cancer development determined by mammographic parenchymal pattern. Cancer 1976, 37: 2486-2492. 10.1002\/1097-0142(197605)37:5<2486::AID-CNCR2820370542>3.0.CO;2-8","journal-title":"Cancer"},{"key":"56_CR9","first-page":"215\u2014228","volume":"17","author":"S-C Yang","year":"2005","unstructured":"Yang S-C, Wang C-M, Chung Y-N, Hsu G-C, Lee S-K, Chung P-C, Chang C-I: A computer aided system for mass detection and classification in digitized mammograms. Biomed. Eng.- Appl. Basis Commun 2005, 17: 215\u2014228.","journal-title":"Biomed. Eng.- Appl. Basis Commun"},{"key":"56_CR10","doi-asserted-by":"publisher","first-page":"377","DOI":"10.1109\/42.41491","volume":"8","author":"S Lai","year":"1989","unstructured":"Lai S, Li X, Bischof W: On techniques for detecting circumscribed masses in mammograms. IEEE Trans. Med. Imagi 1989, 8: 377-386. 10.1109\/42.41491","journal-title":"IEEE Trans. Med. Imagi"},{"key":"56_CR11","volume-title":"Digital Image Processing Using Matlab","author":"RC Gonzalez","year":"2005","unstructured":"Gonzalez RC: Digital Image Processing Using Matlab. Pearson Publication; 2005."},{"key":"56_CR12","volume-title":"Computer-Aided Detection and Diagnosis in mmammography","author":"MP Sampat","year":"2005","unstructured":"Sampat MP, Markey MK, Bovik AC: Computer-Aided Detection and Diagnosis in mmammography. Amsterdam: Elsevier Academic Press; 2005."},{"issue":"7","key":"56_CR13","doi-asserted-by":"publisher","first-page":"971","DOI":"10.1109\/TPAMI.2002.1017623","volume":"24","author":"T Ojala","year":"2002","unstructured":"Ojala T, Pietik\u00e4inen M, M\u00e4enp\u00e4\u00e4 TT: Multiresolution gray-scale and rotation invariant texture classification with local binary pattern. IEEE Trans. Pattern Anal. Mach. Intell 2002, 24(7):971-987. 10.1109\/TPAMI.2002.1017623","journal-title":"IEEE Trans. Pattern Anal. Mach. Intell"},{"issue":"6","key":"56_CR14","doi-asserted-by":"publisher","first-page":"880","DOI":"10.1109\/TMI.2007.895460","volume":"26","author":"NH Eltonsy","year":"2007","unstructured":"Eltonsy NH, Tourassi GD, Elmaghraby AS: A concentric morphology model for the detection of masses in mammography. IEEE Trans. Med. Imagi 2007, 26(6):880-889.","journal-title":"IEEE Trans. Med. Imagi"},{"issue":"1","key":"56_CR15","first-page":"37","volume":"37","author":"G Kom","year":"2007","unstructured":"Kom G, Tiedeu A, Kom M: Automated detection of masses in mammograms by local adaptive thresholding. Comput. Biol. Med 2007, 37(1):37-48.","journal-title":"Med"},{"issue":"1","key":"56_CR16","doi-asserted-by":"publisher","first-page":"59","DOI":"10.1109\/42.481441","volume":"15","author":"N Petrick","year":"1996","unstructured":"Petrick N, Chan HP, Sahiner B, Wei D: An adaptive density-weighted contrast enhancement filter for mammographic breast mass detection. IEEE Trans. Med. Imagi 1996, 15(1):59-67.","journal-title":"IEEE Trans. Med. Imagi"},{"issue":"5","key":"56_CR17","doi-asserted-by":"publisher","first-page":"611","DOI":"10.1109\/42.538938","volume":"15","author":"N Karssemeijer","year":"1996","unstructured":"Karssemeijer N, te Brake GM: Detection of stellate distortions in mammograms. IEEE Trans. Med. Imagi 1996, 15(5):611-619. 10.1109\/42.538938","journal-title":"IEEE Trans. Med. Imagi"},{"key":"56_CR18","doi-asserted-by":"publisher","first-page":"95","DOI":"10.1007\/978-94-011-5318-8_16","volume":"25","author":"N Karssemeijer","year":"1998","unstructured":"Karssemeijer N, te Brake GM: Combining single view features and asymmetry for detection of mass lesions. Digital Mammography 1998, 25: 95-102.","journal-title":"Digital Mammography"}],"container-title":["EURASIP Journal on Image and Video Processing"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1186\/1687-5281-2013-19.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1186\/1687-5281-2013-19\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1186\/1687-5281-2013-19.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2017,4,30]],"date-time":"2017-04-30T21:22:51Z","timestamp":1493587371000},"score":1,"resource":{"primary":{"URL":"https:\/\/jivp-eurasipjournals.springeropen.com\/articles\/10.1186\/1687-5281-2013-19"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2013,4,17]]},"references-count":18,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2013,12]]}},"alternative-id":["56"],"URL":"https:\/\/doi.org\/10.1186\/1687-5281-2013-19","relation":{},"ISSN":["1687-5281"],"issn-type":[{"value":"1687-5281","type":"electronic"}],"subject":[],"published":{"date-parts":[[2013,4,17]]},"article-number":"19"}}