{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,29]],"date-time":"2026-09-29T06:16:41Z","timestamp":1790662601277,"version":"4.1.0"},"reference-count":21,"publisher":"Springer Science and Business Media LLC","issue":"1","content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["J NeuroEngineering Rehabil"],"published-print":{"date-parts":[[2009,12]]},"abstract":"<jats:title>Abstract<\/jats:title>\n          <jats:sec>\n            <jats:title>Background<\/jats:title>\n            <jats:p>A self-contained, self-controlled, pneumatic power harvesting ankle-foot orthosis (PhAFO) to manage foot-drop was developed and tested. Foot-drop is due to a disruption of the motor control pathway and may occur in numerous pathologies such as stroke, spinal cord injury, multiple sclerosis, and cerebral palsy. The objectives for the prototype PhAFO are to provide toe clearance during swing, permit free ankle motion during stance, and harvest the needed power with an underfoot bellow pump pressurized during the stance phase of walking.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Methods<\/jats:title>\n            <jats:p>The PhAFO was constructed from a two-part (tibia and foot) carbon composite structure with an articulating ankle joint. Ankle motion control was accomplished through a cam-follower locking mechanism actuated via a pneumatic circuit connected to the bellow pump and embedded in the foam sole. Biomechanical performance of the prototype orthosis was assessed during multiple trials of treadmill walking of an able-bodied control subject (n = 1). Motion capture and pressure measurements were used to investigate the effect of the PhAFO on lower limb joint behavior and the capacity of the bellow pump to repeatedly generate the required pneumatic pressure for toe clearance.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results<\/jats:title>\n            <jats:p>Toe clearance during swing was successfully achieved during all trials; average clearance 44 \u00b1 5 mm. Free ankle motion was observed during stance and plantarflexion was blocked during swing. In addition, the bellow component repeatedly generated an average of 169 kPa per step of pressure during ten minutes of walking.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusion<\/jats:title>\n            <jats:p>This study demonstrated that fluid power could be harvested with a pneumatic circuit built into an AFO, and used to operate an actuated cam-lock mechanism that controls ankle-foot motion at specific periods of the gait cycle.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1186\/1743-0003-6-19","type":"journal-article","created":{"date-parts":[[2009,6,16]],"date-time":"2009-06-16T06:15:09Z","timestamp":1245132909000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":65,"title":["A pneumatic power harvesting ankle-foot orthosis to prevent foot-drop"],"prefix":"10.1186","volume":"6","author":[{"given":"Robin","family":"Chin","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Elizabeth T","family":"Hsiao-Wecksler","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Eric","family":"Loth","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"G\u00e9za","family":"Kogler","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Scott D","family":"Manwaring","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Serena N","family":"Tyson","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"K Alex","family":"Shorter","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Joel N","family":"Gilmer","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2009,6,16]]},"reference":[{"key":"179_CR1","volume-title":"Gait analysis: normal and pathological function","author":"J Perry","year":"1992","unstructured":"Perry J: Gait analysis: normal and pathological function. Thorofare, NJ: Slack; 1992."},{"key":"179_CR2","doi-asserted-by":"publisher","first-page":"120","DOI":"10.1016\/j.gaitpost.2006.08.006","volume":"26","author":"CJ Newman","year":"2007","unstructured":"Newman CJ, Walsh M, O'Sullivan R, Jenkinson A, Bennett D, Lynch B, O'Brien T: The characteristics of gait in Charcot-Marie-Tooth disease types I and II. Gait Posture 2007, 26: 120-127.","journal-title":"Gait Posture"},{"key":"179_CR3","volume-title":"Atlas of orthoses and assistive devices","author":"American Academy of Orthopaedic Surgeons","year":"1997","unstructured":"American Academy of Orthopaedic Surgeons: Atlas of orthoses and assistive devices. 3rd edition. St. Louis: Mosby; 1997.","edition":"3"},{"key":"179_CR4","volume-title":"Orthotics and prosthetics in rehabilitation","author":"MM Lusardi","year":"2000","unstructured":"Lusardi MM, Nielsen CC: Orthotics and prosthetics in rehabilitation. Boston: Butterworth-Heinemann; 2000."},{"key":"179_CR5","doi-asserted-by":"publisher","first-page":"209","DOI":"10.1080\/03093640500199455","volume":"29","author":"S Yamamoto","year":"2005","unstructured":"Yamamoto S, Hagiwara A, Mizobe T, Yokoyama O, Yasui T: Development of an ankle \u2013 foot orthosis with an oil damper. Prosthet Orthot Int 2005, 29: 209-219.","journal-title":"Prosthet Orthot Int"},{"key":"179_CR6","doi-asserted-by":"publisher","first-page":"162","DOI":"10.1016\/j.apmr.2003.11.026","volume":"86","author":"O Yokoyama","year":"2005","unstructured":"Yokoyama O, Sashika H, Hagiwara A, Yamamoto S, Yasui T: Kinematic effects on gait of a newly designed ankle-foot orthosis with oil damper resistance: A case series of 2 patients with hemiplegia. Arch Phys Med Rehabil 2005, 86: 162-166.","journal-title":"Arch Phys Med Rehabil"},{"key":"179_CR7","first-page":"4140","volume-title":"IEEE International Conference on Robotics and Automation Rome, Italy","author":"SK Banala","year":"2007","unstructured":"Banala SK, Kulpe A, Agrawal SK: A Powered Leg Orthosis for Gait Rehabilitation of Motor-Impaired Patients. IEEE International Conference on Robotics and Automation Rome, Italy 2007, 4140-4145."},{"key":"179_CR8","doi-asserted-by":"publisher","first-page":"24","DOI":"10.1109\/TNSRE.2003.823266","volume":"12","author":"JA Blaya","year":"2004","unstructured":"Blaya JA, Herr H: Adaptive control of a variable-impedance ankle-foot orthosis to assist drop-foot gait. IEEE Trans Neural Syst Rehabil Eng 2004, 12: 24-31.","journal-title":"IEEE Trans Neural Syst Rehabil Eng"},{"key":"179_CR9","first-page":"2025","volume-title":"IEEE International Conference on Robotics and Automation. Pasadena, CA, USA","author":"AW Boehler","year":"2008","unstructured":"Boehler AW, Hollander KW, Sugar TG, Shin D: Design, implementation and test results of a robust control method for a powered ankle foot orthosis (AFO). IEEE International Conference on Robotics and Automation. Pasadena, CA, USA 2008, 2025-2030."},{"key":"179_CR10","doi-asserted-by":"crossref","first-page":"189","DOI":"10.1123\/jab.21.2.189","volume":"21","author":"DP Ferris","year":"2005","unstructured":"Ferris DP, Czerniecki JM, Hannaford B: An ankle-foot orthosis powered by artificial pneumatic muscles. J Appl Biomech 2005, 21: 189-197.","journal-title":"J Appl Biomech"},{"key":"179_CR11","doi-asserted-by":"publisher","first-page":"2636","DOI":"10.1016\/j.jbiomech.2006.12.006","volume":"40","author":"KE Gordon","year":"2007","unstructured":"Gordon KE, Ferris DP: Learning to walk with a robotic ankle exoskeleton. J Biomech 2007, 40: 2636-2644.","journal-title":"J Biomech"},{"key":"179_CR12","doi-asserted-by":"publisher","first-page":"620","DOI":"10.1016\/j.gaitpost.2006.07.002","volume":"25","author":"JA Norris","year":"2007","unstructured":"Norris JA, Granata KP, Mitros MR, Byrne EM, Marsh AP: Effect of augmented plantarflexion power on preferred walking speed and economy in young and older adults. Gait Posture 2007, 25: 620-627.","journal-title":"Gait Posture"},{"key":"179_CR13","first-page":"28","volume-title":"IEEE 10th International Conference on Rehabilitation Robotics. Noordwijk, The Netherlands","author":"AM Oymagil","year":"2007","unstructured":"Oymagil AM, Hitt JK, Sugar T, Fleeger J: Control of a Regenerative Braking Powered Ankle Foot Orthosis. IEEE 10th International Conference on Rehabilitation Robotics. Noordwijk, The Netherlands 2007, 28-34."},{"key":"179_CR14","doi-asserted-by":"publisher","first-page":"3","DOI":"10.1186\/1743-0003-3-3","volume":"3","author":"GS Sawicki","year":"2006","unstructured":"Sawicki GS, Domingo A, Ferris DP: The effects of powered ankle-foot orthoses on joint kinematics and muscle activation during walking in individuals with incomplete spinal cord injury. J Neuroeng Rehabil. 2006, 3: 3.","journal-title":"J Neuroeng Rehabil."},{"key":"179_CR15","volume-title":"8th International Symposium on Fluid Power, ASME Fluids Engineering Conference. Jacksonville, FL","author":"R Chin","year":"2008","unstructured":"Chin R, Loth E, Hsiao-Wecksler ET: Fluid-power harvesting by pneumatic bellow during human gait. 8th International Symposium on Fluid Power, ASME Fluids Engineering Conference. Jacksonville, FL 2008."},{"key":"179_CR16","doi-asserted-by":"publisher","first-page":"69","DOI":"10.1016\/0021-9290(80)90180-3","volume":"13","author":"PR Cavanagh","year":"1980","unstructured":"Cavanagh PR, Ae M: A technique for the display of pressure distributions beneath the foot. J Biomech 1980, 13: 69-75.","journal-title":"J Biomech"},{"key":"179_CR17","doi-asserted-by":"publisher","first-page":"838","DOI":"10.1016\/j.jbiomech.2007.11.001","volume":"41","author":"DT Fong","year":"2008","unstructured":"Fong DT, Mao DW, Li JX, Hong Y: Greater toe grip and gentler heel strike are the strategies to adapt to slippery surface. J Biomech 2008, 41: 838-844.","journal-title":"J Biomech"},{"key":"179_CR18","volume-title":"Dynamics of Human Gait","author":"CL Vaughan","year":"1999","unstructured":"Vaughan CL, Davis BL, O'Connor JC: Dynamics of Human Gait. 2nd edition. Cape Town, South Africa: Kiboho Publishers; 1999.","edition":"2"},{"key":"179_CR19","volume-title":"Biomechanics and Motor Conbtrol of Human Movement","author":"AD Winter","year":"2005","unstructured":"Winter AD: Biomechanics and Motor Conbtrol of Human Movement. 3rd edition. Hoboken, NJ: John Wiley & Sons; 2005.","edition":"3"},{"issue":"1","key":"179_CR20","doi-asserted-by":"publisher","first-page":"65","DOI":"10.1016\/j.gaitpost.2009.03.003","volume":"30","author":"JC Menant","year":"2009","unstructured":"Menant JC, Steele JR, Menz HB, Munro BJ, Lord SR: Effects of walking surfaces and footwear on temporo-spatial gait parameters in young and older people. Gait Posture 2009,30(1):65-70.","journal-title":"Gait Posture"},{"key":"179_CR21","volume-title":"7th Japanese Fluid Power Society International Symposium on Fluid Power. Toyama, Japan","author":"M Takaiwa","year":"2008","unstructured":"Takaiwa M, Noritsugu T: Development of pneumatic walking support shoes using potential energy of human. 7th Japanese Fluid Power Society International Symposium on Fluid Power. Toyama, Japan 2008."}],"container-title":["Journal of NeuroEngineering and Rehabilitation"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/1743-0003-6-19.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,8,31]],"date-time":"2021-08-31T23:55:24Z","timestamp":1630454124000},"score":1,"resource":{"primary":{"URL":"https:\/\/jneuroengrehab.biomedcentral.com\/articles\/10.1186\/1743-0003-6-19"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2009,6,16]]},"references-count":21,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2009,12]]}},"alternative-id":["179"],"URL":"https:\/\/doi.org\/10.1186\/1743-0003-6-19","relation":{},"ISSN":["1743-0003"],"issn-type":[{"value":"1743-0003","type":"electronic"}],"subject":[],"published":{"date-parts":[[2009,6,16]]},"assertion":[{"value":"5 November 2008","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"16 June 2009","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"16 June 2009","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}}],"article-number":"19"}}