{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,22]],"date-time":"2026-01-22T17:08:30Z","timestamp":1769101710777,"version":"3.49.0"},"reference-count":39,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2011,7,20]],"date-time":"2011-07-20T00:00:00Z","timestamp":1311120000000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/2.0"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Radiat Oncol"],"published-print":{"date-parts":[[2011,12]]},"DOI":"10.1186\/1748-717x-6-85","type":"journal-article","created":{"date-parts":[[2011,7,20]],"date-time":"2011-07-20T14:15:53Z","timestamp":1311171353000},"source":"Crossref","is-referenced-by-count":18,"title":["Eight years of IMRT quality assurance with ionization chambers and film dosimetry: experience of the montpellier comprehensive cancer center"],"prefix":"10.1186","volume":"6","author":[{"given":"Pascal","family":"Fenoglietto","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Benoit","family":"Lalibert\u00e9","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Norbert","family":"Aill\u00e8res","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Olivier","family":"Riou","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jean-Bernard","family":"Dubois","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"David","family":"Azria","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2011,7,20]]},"reference":[{"key":"408_CR1","doi-asserted-by":"publisher","first-page":"21","DOI":"10.1016\/S0360-3016(99)00101-7","volume":"45","author":"E Butler","year":"1999","unstructured":"Butler E, The BS, Grant WH: SMART (simultaneous modulated accelerated radiation therapy) boost: A new accelerated fractionation schedule for the treatment of head and neck cancer with intensity modulated radiotherapy. Int J Radiat Oncol Biol Phys 1999, 45: 21-32. 10.1016\/S0360-3016(99)00101-7","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"408_CR2","doi-asserted-by":"publisher","first-page":"241","DOI":"10.1016\/j.radonc.2005.10.011","volume":"77","author":"E Miles","year":"2005","unstructured":"Miles E, Clark C, Urbano M: The impact of introducing intensity modulated radiotherapy into routine clinical practice. Radiother Oncol 2005, 77: 241-246. 10.1016\/j.radonc.2005.10.011","journal-title":"Radiother Oncol"},{"key":"408_CR3","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1016\/j.radonc.2003.09.004","volume":"70","author":"E Adams","year":"2004","unstructured":"Adams E, Convery D, Cosgrove V: Clinical implementation of dynamic and step-and-shoot IMRT to treat prostate cancer with high risk of pelvic lymph node involvement. Radiother Oncol 2004, 70: 1-10. 10.1016\/j.radonc.2003.09.004","journal-title":"Radiother Oncol"},{"key":"408_CR4","doi-asserted-by":"publisher","first-page":"189","DOI":"10.1016\/j.radonc.2003.10.012","volume":"70","author":"C Clark","year":"2004","unstructured":"Clark C, Bidmead A, Mubata C: Intensity-modulated radiotherapy improves target coverage, spinal cord sparing and allows dose escalation in patients with locally advanced cancer of the larynx. Radiother Oncol 2004, 70: 189-198. 10.1016\/j.radonc.2003.10.012","journal-title":"Radiother Oncol"},{"key":"408_CR5","doi-asserted-by":"publisher","first-page":"273","DOI":"10.1120\/1.1499095","volume":"3","author":"C Clark","year":"2002","unstructured":"Clark C, Mubata C, Meehan C: IMRT clinical implementation: Prostate and pelvic node irradiation using Helios and a 120-leaf multileaf collimator. J Appl Clin Med Phys 2002, 3: 273-284. 10.1120\/1.1499095","journal-title":"J Appl Clin Med Phys"},{"key":"408_CR6","doi-asserted-by":"publisher","first-page":"850","DOI":"10.1259\/bjr\/19737738","volume":"76","author":"H McNair","year":"2003","unstructured":"McNair H, Adams E, Clark C: Implementation of IMRT in the radiotherapy department. Br J Radiol 2003, 76: 850-856. 10.1259\/bjr\/19737738","journal-title":"Br J Radiol"},{"key":"408_CR7","doi-asserted-by":"publisher","first-page":"161","DOI":"10.1016\/S0958-3947(02)00099-7","volume":"27","author":"C Saw","year":"2002","unstructured":"Saw C, Ayyangar K, Zhen W: Clinical implementation of intensity-modulated radiation therapy. Med Dosim 2002, 27: 161-169. 10.1016\/S0958-3947(02)00099-7","journal-title":"Med Dosim"},{"key":"408_CR8","doi-asserted-by":"publisher","first-page":"80","DOI":"10.1120\/jacmp.2022.25307","volume":"5","author":"X Zhu","year":"2004","unstructured":"Zhu X, Schultz C, Gillin M: Planning quality and delivery efficiency of sMLC delivered IMRT treatment of oropharyngeal cancers evaluated by RTOG H-0022 dosimetric criteria. J Appl Clin Med Phys 2004, 5: 80-95.","journal-title":"J Appl Clin Med Phys"},{"key":"408_CR9","doi-asserted-by":"publisher","first-page":"91","DOI":"10.1016\/S0958-3947(02)00090-0","volume":"27","author":"G Ozyigit","year":"2002","unstructured":"Ozyigit G, Chao K: Clinical experience of head-and-neck cancer IMRT with serial tomotherapy* 1. Med Dosim 2002, 27: 91-98. 10.1016\/S0958-3947(02)00090-0","journal-title":"Med Dosim"},{"key":"408_CR10","doi-asserted-by":"publisher","first-page":"181","DOI":"10.1016\/S0167-8140(01)00305-X","volume":"60","author":"A Van Esch","year":"2001","unstructured":"Van Esch A, Vanstraelen B, Verstraete J: Pre-treatment dosimetric verification by means of a liquid-filled electronic portal imaging device during dynamic delivery of intensity modulated treatment fields. Radiother Oncol 2001, 60: 181-190. 10.1016\/S0167-8140(01)00305-X","journal-title":"Radiother Oncol"},{"key":"408_CR11","doi-asserted-by":"publisher","first-page":"235","DOI":"10.1016\/j.radonc.2004.02.014","volume":"71","author":"N Linthout","year":"2004","unstructured":"Linthout N, Verellen D, Van Acker S: A simple theoretical verification of monitor unit calculation for intensity modulated beams using dynamic mini-multileaf collimation. Radiother Oncol 2004, 71: 235-241. 10.1016\/j.radonc.2004.02.014","journal-title":"Radiother Oncol"},{"key":"408_CR12","doi-asserted-by":"publisher","first-page":"199","DOI":"10.1016\/j.radonc.2003.10.014","volume":"70","author":"D L\u00e9tourneau","year":"2004","unstructured":"L\u00e9tourneau D, Gulam M, Yan D: Evaluation of a 2D diode array for IMRT quality assurance. Radiother Oncol 2004, 70: 199-206. 10.1016\/j.radonc.2003.10.014","journal-title":"Radiother Oncol"},{"key":"408_CR13","doi-asserted-by":"publisher","first-page":"880","DOI":"10.1016\/S0360-3016(01)01749-7","volume":"51","author":"I Working","year":"2001","unstructured":"Working I: Intensity-modulated radiotherapy: current status and issues of interest. Int J Radiat Oncol Biol Phys 2001, 51: 880-914. 10.1016\/S0360-3016(01)01749-7","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"408_CR14","doi-asserted-by":"publisher","first-page":"256","DOI":"10.1016\/0167-8140(94)90025-6","volume":"32","author":"A Dutreix","year":"1994","unstructured":"Dutreix A, Derreumaux S, Chavaudra J: Quality control of radiotherapy centres in Europe: beam calibration. Radiother Oncol 1994, 32: 256-264. 10.1016\/0167-8140(94)90025-6","journal-title":"Radiother Oncol"},{"key":"408_CR15","doi-asserted-by":"publisher","first-page":"273","DOI":"10.1016\/S0167-8140(99)00101-2","volume":"55","author":"I Ferreira","year":"2000","unstructured":"Ferreira I, Dutreix A, Bridier A: The ESTRO-QUALity assurance network (EQUAL). Radiother Oncol 2000, 55: 273-284. 10.1016\/S0167-8140(99)00101-2","journal-title":"Radiother Oncol"},{"key":"408_CR16","doi-asserted-by":"publisher","first-page":"340","DOI":"10.1016\/j.radonc.2005.06.021","volume":"76","author":"S Gillis","year":"2005","unstructured":"Gillis S, De Wagter C, Bohsung J: An inter-centre quality assurance network for IMRT verification: results of the ESTRO QUASIMODO project. Radiother Oncol 2005, 76: 340-353. 10.1016\/j.radonc.2005.06.021","journal-title":"Radiother Oncol"},{"key":"408_CR17","doi-asserted-by":"publisher","first-page":"108","DOI":"10.1016\/j.ijrobp.2007.05.092","volume":"71","author":"J Palta","year":"2008","unstructured":"Palta J, Liu C, Li J: Quality assurance of intensity-modulated radiation therapy. Int J Radiat Oncol Biol Phys 2008, 71: 108-112. 10.1016\/j.ijrobp.2007.05.092","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"408_CR18","doi-asserted-by":"publisher","first-page":"3629","DOI":"10.1088\/0031-9155\/47\/20\/305","volume":"47","author":"I Chetty","year":"2002","unstructured":"Chetty I, Charland P: Investigation of Kodak EDR film for megavoltage photon beam dosimetry. Phys Med Biol 2002, 47: 3629-3641. 10.1088\/0031-9155\/47\/20\/305","journal-title":"Phys Med Biol"},{"key":"408_CR19","doi-asserted-by":"publisher","first-page":"122","DOI":"10.1016\/j.meddos.2004.03.004","volume":"29","author":"M Dehghanpour","year":"2004","unstructured":"Dehghanpour M, Pham H: A retrospective analysis to determine if the timing of H&D curve production has a clinically significant effect on the percent difference in agreement of isodose delivery for film-based IMRT QA. Med Dosim 2004, 29: 122-123. 10.1016\/j.meddos.2004.03.004","journal-title":"Med Dosim"},{"key":"408_CR20","doi-asserted-by":"publisher","first-page":"656","DOI":"10.1118\/1.598248","volume":"25","author":"D Low","year":"1998","unstructured":"Low D, Harms W, Mutic S: A technique for the quantitative evaluation of dose distributions. Med Phys 1998, 25: 656-661. 10.1118\/1.598248","journal-title":"Med Phys"},{"key":"408_CR21","doi-asserted-by":"publisher","first-page":"29","DOI":"10.1016\/j.zemedi.2008.09.001","volume":"19","author":"F Schneider","year":"2009","unstructured":"Schneider F, Polednik M, Wolff D: Optimization of the Gafchromic\u2122 EBT protocol for IMRT QA. Z Med Phys 2009, 19: 29-37.","journal-title":"Z Med Phys"},{"key":"408_CR22","doi-asserted-by":"publisher","first-page":"319","DOI":"10.1016\/j.radonc.2004.02.016","volume":"71","author":"D Boehmer","year":"2004","unstructured":"Boehmer D, Bohsung J, Eichwurzel I: Clinical and physical quality assurance for intensity modulated radiotherapy of prostate cancer. Radiother Oncol 2004, 71: 319-325. 10.1016\/j.radonc.2004.02.016","journal-title":"Radiother Oncol"},{"key":"408_CR23","doi-asserted-by":"publisher","first-page":"2455","DOI":"10.1118\/1.1598711","volume":"30","author":"D Low","year":"2003","unstructured":"Low D, Dempsey J: Evaluation of the gamma dose distribution comparison method. Med Phys 2003, 30: 2455-2464. 10.1118\/1.1598711","journal-title":"Med Phys"},{"key":"408_CR24","doi-asserted-by":"publisher","first-page":"399","DOI":"10.1016\/j.radonc.2007.10.004","volume":"85","author":"E De Martin","year":"2007","unstructured":"De Martin E, Fiorino C, Broggi S: Agreement criteria between expected and measured field fluences in IMRT of head and neck cancer: The importance and use of the histograms statistical analysis. Radiother Oncol 2007, 85: 399-406.","journal-title":"Radiother Oncol"},{"key":"408_CR25","doi-asserted-by":"publisher","first-page":"303","DOI":"10.1016\/j.meddos.2008.03.004","volume":"33","author":"E Wilcox","year":"2008","unstructured":"Wilcox E, Daskalov G, Pavlonnis G: Dosimetric Verification of Intensity Modulated Radiation Therapy of 172 Patients Treated for Various Disease Sites: Comparison of EBT Film Dosimetry, Ion Chamber Measurements, and Independent MU Calculations. Med Dosim 2008, 33: 303-309. 10.1016\/j.meddos.2008.03.004","journal-title":"Med Dosim"},{"key":"408_CR26","doi-asserted-by":"publisher","first-page":"3661","DOI":"10.1118\/1.2952643","volume":"35","author":"G Yan","year":"2008","unstructured":"Yan G, Fox C, Liu C: The extraction of true profiles for TPS commissioning and its impact on IMRT patient-specific QA. Med Phys 2008, 35: 3661-3670. 10.1118\/1.2952643","journal-title":"Med Phys"},{"key":"408_CR27","doi-asserted-by":"publisher","first-page":"53","DOI":"10.1016\/S0167-8140(02)00174-3","volume":"65","author":"A Van Esch","year":"2002","unstructured":"Van Esch A, Bohsung J, Sorvari P: Acceptance tests and quality control (QC) procedures for the clinical implementation of intensity modulated radiotherapy (IMRT) using inverse planning and the sliding window technique: experience from five radiotherapy departments. Radiother Oncol 2002, 65: 53-70. 10.1016\/S0167-8140(02)00174-3","journal-title":"Radiother Oncol"},{"key":"408_CR28","doi-asserted-by":"publisher","first-page":"373","DOI":"10.1007\/s11517-007-0249-z","volume":"46","author":"D Gonz\u00e1lez-Casta\u00f1o","year":"2008","unstructured":"Gonz\u00e1lez-Casta\u00f1o D, Pena J, S\u00e1nchez-Doblado F: The change of response of ionization chambers in the penumbra and transmission regions: impact for IMRT verification. Med Biol Eng Comput 2008, 46: 373-380. 10.1007\/s11517-007-0249-z","journal-title":"Med Biol Eng Comput"},{"key":"408_CR29","doi-asserted-by":"publisher","first-page":"2693","DOI":"10.1120\/jacmp.v8i4.2693","volume":"8","author":"P Zygmanski","year":"2007","unstructured":"Zygmanski P, Rosca F, Kadam D: Determination of depth and field size dependence of multileaf collimator transmission in intensity-modulated radiation therapy beams. J Appl Clin Med Phys 2007, 8: 2693.","journal-title":"J Appl Clin Med Phys"},{"key":"408_CR30","doi-asserted-by":"publisher","first-page":"2209","DOI":"10.1118\/1.1410123","volume":"28","author":"T LoSasso","year":"2001","unstructured":"LoSasso T, Chui C, Ling C: Comprehensive quality assurance for the delivery of intensity modulated radiotherapy with a multileaf collimator used in the dynamic mode. Med Phys 2001, 28: 2209-2219. 10.1118\/1.1410123","journal-title":"Med Phys"},{"key":"408_CR31","doi-asserted-by":"publisher","first-page":"799","DOI":"10.1118\/1.1567951","volume":"30","author":"J Li","year":"2003","unstructured":"Li J, Dempsey J, Ding L: Validation of dynamic MLC-controller log files using a two-dimensional diode array. Med Phys 2003, 30: 799-805. 10.1118\/1.1567951","journal-title":"Med Phys"},{"key":"408_CR32","doi-asserted-by":"publisher","first-page":"301","DOI":"10.1016\/j.ijrobp.2006.11.056","volume":"68","author":"F S\u00e1nchez-Doblado","year":"2007","unstructured":"S\u00e1nchez-Doblado F, Hartmann G, Pena J: Uncertainty estimation in intensity-modulated radiotherapy absolute dosimetry verification. Int J Radiat Oncol Biol Phys 2007, 68: 301-310. 10.1016\/j.ijrobp.2006.11.056","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"408_CR33","doi-asserted-by":"publisher","first-page":"2921","DOI":"10.1088\/0031-9155\/52\/10\/019","volume":"52","author":"B Poppe","year":"2007","unstructured":"Poppe B, Djouguela A, Blechschmidt A: Spatial resolution of 2D ionization chamber arrays for IMRT dose verification. Phys Med Biol 2007, 52: 2921-2935. 10.1088\/0031-9155\/52\/10\/019","journal-title":"Phys Med Biol"},{"key":"408_CR34","doi-asserted-by":"publisher","first-page":"1391","DOI":"10.1088\/0031-9155\/46\/5\/305","volume":"46","author":"N Suchowerska","year":"2001","unstructured":"Suchowerska N, Hoban P, Butson M: Directional dependence in film dosimetry. Phys Med Biol 2001, 46: 1391-1397. 10.1088\/0031-9155\/46\/5\/305","journal-title":"Phys Med Biol"},{"key":"408_CR35","doi-asserted-by":"publisher","first-page":"329","DOI":"10.1118\/1.598520","volume":"26","author":"J Sykes","year":"1999","unstructured":"Sykes J, James H, Williams P: How much does film sensitivity increase at depth for larger field sizes? Med Phys 1999, 26: 329-30. 10.1118\/1.598520","journal-title":"Med Phys"},{"key":"408_CR36","doi-asserted-by":"publisher","first-page":"289","DOI":"10.1016\/j.radonc.2008.07.008","volume":"88","author":"W van Elmpt","year":"2008","unstructured":"van Elmpt W, McDermott L, Nijsten S: A literature review of electronic portal imaging for radiotherapy dosimetry. Radiother Oncol 2008, 88: 289-309. 10.1016\/j.radonc.2008.07.008","journal-title":"Radiother Oncol"},{"key":"408_CR37","doi-asserted-by":"publisher","first-page":"1286","DOI":"10.1118\/1.2712042","volume":"34","author":"R Crescenti","year":"2007","unstructured":"Crescenti R, Scheib S, Schneider U: Introducing gel dosimetry in a clinical environment: Customization of polymer gel composition and magnetic resonance imaging parameters used for 3D dose verifications in radiosurgery and intensity modulated radiotherapy. Med Phys 2007, 34: 1286-1297. 10.1118\/1.2712042","journal-title":"Med Phys"},{"key":"408_CR38","doi-asserted-by":"publisher","first-page":"330","DOI":"10.1016\/j.radonc.2008.07.002","volume":"89","author":"T Pawlicki","year":"2008","unstructured":"Pawlicki T, Yoo S, Court L: Moving from IMRT QA measurements toward independent computer calculations using control charts. Radiother Oncol 2008, 89: 330-337. 10.1016\/j.radonc.2008.07.002","journal-title":"Radiother Oncol"},{"key":"408_CR39","doi-asserted-by":"publisher","first-page":"634","DOI":"10.1016\/j.ijrobp.2007.09.054","volume":"70","author":"L Lee","year":"2008","unstructured":"Lee L, Le Q, Xing L: Retrospective IMRT dose reconstruction based on cone-beam CT and MLC log-file. Int J Radiat Oncol Biol Phys 2008, 70: 634-644. 10.1016\/j.ijrobp.2007.09.054","journal-title":"Int J Radiat Oncol Biol Phys"}],"container-title":["Radiation Oncology"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1186\/1748-717X-6-85.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1186\/1748-717X-6-85\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1186\/1748-717X-6-85.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2019,1,22]],"date-time":"2019-01-22T23:57:32Z","timestamp":1548201452000},"score":1,"resource":{"primary":{"URL":"https:\/\/ro-journal.biomedcentral.com\/articles\/10.1186\/1748-717X-6-85"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2011,7,20]]},"references-count":39,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2011,12]]}},"alternative-id":["408"],"URL":"https:\/\/doi.org\/10.1186\/1748-717x-6-85","relation":{},"ISSN":["1748-717X"],"issn-type":[{"value":"1748-717X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2011,7,20]]},"article-number":"85"}}