{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,16]],"date-time":"2026-05-16T16:57:44Z","timestamp":1778950664210,"version":"3.51.4"},"reference-count":51,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2008,8,7]],"date-time":"2008-08-07T00:00:00Z","timestamp":1218067200000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/2.0"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J Orthop Surg Res"],"published-print":{"date-parts":[[2008,12]]},"DOI":"10.1186\/1749-799x-3-35","type":"journal-article","created":{"date-parts":[[2008,8,8]],"date-time":"2008-08-08T06:13:30Z","timestamp":1218176010000},"source":"Crossref","is-referenced-by-count":10,"title":["Failure of dual radius hydroxyapatite-coated acetabular cups"],"prefix":"10.1186","volume":"3","author":[{"given":"Fabio","family":"D'Angelo","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Mauro","family":"Molina","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Giacomo","family":"Riva","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Giovanni","family":"Zatti","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Paolo","family":"Cherubino","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2008,8,7]]},"reference":[{"key":"80_CR1","doi-asserted-by":"crossref","first-page":"147","DOI":"10.1097\/00003086-198712000-00014","volume":"225","author":"RG Geesink","year":"1987","unstructured":"Geesink RG, de Groot K, Klein CP: Chemical implant fixation using hydroxyl-apatite coatings. The development of a human total hip prosthesis for chemical fixation to bone using hydroxyl-apatite coatings on titanium substrates. Clin Orthop Relat Res. 1987, 225: 147-170.","journal-title":"Clin Orthop Relat Res"},{"key":"80_CR2","doi-asserted-by":"crossref","first-page":"74","DOI":"10.2106\/00004623-199901000-00011","volume":"81","author":"JS Xenos","year":"1999","unstructured":"Xenos JS, Callaghan JJ, Heekin RD, Hopkinson WJ, Savory CG, Moore MS: The porous-coated anatomic total hip prosthesis, inserted without cement. A prospective study with a minimum of ten years of follow-up. J Bone Joint Surg Am. 1999, 81: 74-82.","journal-title":"J Bone Joint Surg Am"},{"key":"80_CR3","doi-asserted-by":"crossref","first-page":"21","DOI":"10.1097\/00003086-198912000-00004","volume":"249","author":"WH Harris","year":"1989","unstructured":"Harris WH, Maloney WJ: Hybrid total hip arthroplasty. Clin Orthop Relat Res. 1989, 249: 21-29.","journal-title":"Clin Orthop Relat Res"},{"issue":"4","key":"80_CR4","doi-asserted-by":"crossref","first-page":"737","DOI":"10.2106\/00004623-196951040-00012","volume":"51","author":"WH Harris","year":"1969","unstructured":"Harris WH: Traumatic arthritis of the hip after dislocation and acetabular fractures: treatment by mold arthroplasty. An end-result study using a new method of result evaluation. J Bone Joint Surg Am. 1969, 51 (4): 737-755.","journal-title":"J Bone Joint Surg Am"},{"key":"80_CR5","doi-asserted-by":"crossref","first-page":"2378","DOI":"10.2106\/00004623-200312000-00016","volume":"85","author":"E Ebramzadeh","year":"2003","unstructured":"Ebramzadeh E, Sangiorgio SN, Lattuada F, Kang JS, Chiesa R, McKellop HA, Dorr LD: Accuracy of measurament of polyethylene wear with use of radiographs of total hip replacements. J Bone Joint Surg Am. 2003, 85: 2378-84.","journal-title":"J Bone Joint Surg Am"},{"key":"80_CR6","doi-asserted-by":"crossref","first-page":"505","DOI":"10.2106\/00004623-200303000-00017","volume":"85","author":"AJ Hui","year":"2003","unstructured":"Hui AJ, McCalden RW, Martell JM, MacDonald SJ, Bourne RB, Rorabeck CK: Validation of two and three-dimensional radiographic techniques for measuring polyethylene wear after total hip arthroplasty. J Bone Joint Surg Am. 2003, 85: 505-511.","journal-title":"J Bone Joint Surg Am"},{"key":"80_CR7","doi-asserted-by":"crossref","first-page":"965","DOI":"10.2106\/00004623-199407000-00002","volume":"76","author":"JM Lawrence","year":"1994","unstructured":"Lawrence JM, Engh CA, Macalino GE, Lauro GR: Outcome of revision hip arthroplasty done without cement. J Bone Joint Surg Am. 1994, 76: 965-973.","journal-title":"J Bone Joint Surg Am"},{"key":"80_CR8","first-page":"20","volume":"121","author":"JG DeLee","year":"1976","unstructured":"DeLee JG, Charnley J: Radiological demarcation of cemented sockets in total hip replacement. Clin Orthop Relat Res. 1976, 121: 20-32.","journal-title":"Clin Orthop Relat Res"},{"key":"80_CR9","doi-asserted-by":"publisher","first-page":"233","DOI":"10.1097\/01.blo.0000195923.28480.d4","volume":"446","author":"Kim Shin-Yoon","year":"2006","unstructured":"Shin-Yoon Kim, Do-Heon Kim, Yong-Goo Kim, Chang-Wug Oh, Joo-Chul Ihn: Early Failure of Hemispheric Hydroxyapatite-coated Acetabular Cups. Clin Orthop Relat Res. 2006, 446: 233-238. 10.1097\/01.blo.0000195923.28480.d4.","journal-title":"Clin Orthop Relat Res"},{"key":"80_CR10","doi-asserted-by":"publisher","first-page":"200","DOI":"10.1097\/00003086-199810000-00021","volume":"355","author":"WN Capello","year":"1998","unstructured":"Capello WN, D'Antonio JA, Manley MT, Feinberg JR: Hydroxyapatite in total hip arthoplasty: clinical results and critical issues. Clin Orthop Relat Res. 1998, 355: 200-211. 10.1097\/00003086-199810000-00021.","journal-title":"Clin Orthop Relat Res"},{"key":"80_CR11","doi-asserted-by":"crossref","first-page":"1333","DOI":"10.2106\/00004623-200109000-00007","volume":"83","author":"H Kawamura","year":"2001","unstructured":"Kawamura H, Dunbar MJ, Murray P, Bourne RB, Rorabeck CH: The porous coated anatomic total hip replacement: a ten to fourteen year follow-up study of cementless total hip arthroplasty. J Bone Joint Surg Am. 2001, 83: 1333-1338.","journal-title":"J Bone Joint Surg Am"},{"key":"80_CR12","doi-asserted-by":"crossref","first-page":"45","DOI":"10.1302\/0301-620X.69B1.3818732","volume":"69","author":"CA Engh","year":"1987","unstructured":"Engh CA, Bobyn JD, Glassman AH: Porous-coated hip replacement. The factors governing bone ingrowth, stress shielding, and clinical results. J Bone Joint Surg Br. 1987, 69: 45-49.","journal-title":"J Bone Joint Surg Br"},{"key":"80_CR13","doi-asserted-by":"publisher","first-page":"536","DOI":"10.3109\/17453679209154731","volume":"63","author":"S Overgaard","year":"1992","unstructured":"Overgaard S, Knudsen HM, Hansen LN, Mossing N: Hip arthroplasty in Jutland, Denmark: age and sex-specific incidences of primary operation. Acta Orthop Scand. 1992, 63: 536-542.","journal-title":"Acta Orthop Scand"},{"key":"80_CR14","doi-asserted-by":"publisher","first-page":"1375","DOI":"10.1002\/jbm.820211203","volume":"21","author":"K deGroot","year":"1987","unstructured":"deGroot K, Geesink R, Klein CP, Serekian P: Plasma spray coatings of hydroxyapatite. J Biomed Mater Res. 1987, 21: 1375-1381. 10.1002\/jbm.820211203.","journal-title":"J Biomed Mater Res"},{"key":"80_CR15","first-page":"300","volume":"272","author":"K Soballe","year":"1991","unstructured":"Soballe K, Hansen ES, BRockstedt-Rasmussen H, Hjortdal VE, Juhl GI, Pedersen CM, Hvid I, Bunger C: Gap healing enhanced by hydroxyapatite coating in dogs. Clin Orthop Relat Res. 1991, 272: 300-307.","journal-title":"Clin Orthop Relat Res"},{"key":"80_CR16","doi-asserted-by":"crossref","first-page":"824","DOI":"10.1302\/0301-620X.76B5.8083278","volume":"76","author":"F Lintner","year":"1994","unstructured":"Lintner F, Bohm G, Huber M, Scholz R: Histology of tissue adjacent to an HAC-coated femoral prosthesis: a case report. J Bone Joint Surg Br. 1994, 76: 824-830.","journal-title":"J Bone Joint Surg Br"},{"key":"80_CR17","doi-asserted-by":"publisher","first-page":"163","DOI":"10.1097\/00003086-199906000-00021","volume":"363","author":"DD D'Lima","year":"1999","unstructured":"D'Lima DD, Walker RH, Colwell CW: Omnifit-HA stem in total hip arthroplasty: a 2- to 5-year followup. Clin Orthop Relat Res. 1999, 363: 163-169. 10.1097\/00003086-199906000-00021.","journal-title":"Clin Orthop Relat Res"},{"key":"80_CR18","doi-asserted-by":"crossref","first-page":"741","DOI":"10.1302\/0301-620X.73B5.1654336","volume":"73","author":"RJ Furlong","year":"1991","unstructured":"Furlong RJ, Osborn JF: Fixation of hip prostheses by hydroxyapatite ceramic coatings. J Bone Joint Surg Br. 1991, 73: 741-74.","journal-title":"J Bone Joint Surg Br"},{"key":"80_CR19","doi-asserted-by":"crossref","first-page":"147","DOI":"10.1097\/00003086-198712000-00014","volume":"225","author":"RG Geesink","year":"1987","unstructured":"Geesink RG, de Groot K, Klein CP: Chemical implant fixation using hydroxyl-apatite coatings: the development of a human total hip prosthesis for chemical fixation to bone using hydroxyl-apatite coatings on titanium substrates. Clin Orthop Relat Res. 1987, 225: 147-170.","journal-title":"Clin Orthop Relat Res"},{"key":"80_CR20","doi-asserted-by":"crossref","first-page":"1023","DOI":"10.2106\/00004623-199707000-00008","volume":"79","author":"WN Capello","year":"1997","unstructured":"Capello WN, D'Antonio JA, Feinberg JR, Manley MT: Hydroxyapatite-coated total hip femoral components in patients less than fifty years old: clinical and radiographic results after five to eight years of follow-up. J Bone Joint Surg Am. 1997, 79: 1023-1029.","journal-title":"J Bone Joint Surg Am"},{"key":"80_CR21","doi-asserted-by":"crossref","first-page":"1918","DOI":"10.2106\/00004623-199612000-00018","volume":"78","author":"WL Jaffe","year":"1996","unstructured":"Jaffe WL, Scott DF: Total hip arthroplasty with hydroxyapatitecoated prostheses. J Bone Joint Surg M. 1996, 78: 1918-1934.","journal-title":"J Bone Joint Surg M"},{"key":"80_CR22","doi-asserted-by":"crossref","first-page":"1496","DOI":"10.2106\/00004623-198971100-00007","volume":"71","author":"BF Kavanagh","year":"1989","unstructured":"Kavanagh BF, Dewitz MA, Ilstrup DM, Stauffer RN, Coventry MB: Charnley total hip arthroplasty with cement: fifteen-year results. J Bone Joint Surg Am. 1989, 71: 1496-1503.","journal-title":"J Bone Joint Surg Am"},{"key":"80_CR23","doi-asserted-by":"crossref","first-page":"1175","DOI":"10.2106\/00004623-199808000-00011","volume":"80","author":"MT Manley","year":"1998","unstructured":"Manley MT, Capello WN, D'Antonio JA, Geesink RGT: Fixation of acetabular cups without cement in total hip arthroplasty. A comparison of three different implant surface at minimum duration of follow-up of five years. J Bone Joint Surg Am. 1998, 80: 1175-1185.","journal-title":"J Bone Joint Surg Am"},{"key":"80_CR24","doi-asserted-by":"publisher","first-page":"582","DOI":"10.1302\/0301-620X.81B4.8715","volume":"81","author":"M R\u00f8kkum","year":"1999","unstructured":"R\u00f8kkum M, Brandt M, Bye K, Hetland KR, Waage S, Reigstad A: Polythylene wear, osteolysis and adetabular loosening with an HA-coated hip prosthesis. A follow-up of 94 consecutive arthroplasties. J Bone Joint Surg Br. 1999, 81: 582-589. 10.1302\/0301-620X.81B4.8715.","journal-title":"J Bone Joint Surg Br"},{"key":"80_CR25","first-page":"39","volume":"261","author":"RGT Geesink","year":"1990","unstructured":"Geesink RGT: Hydroxyapatite-coated total hip prostesis: two year clinical and roentgenographic results of 100 cases. Clin Orthop Relat Res. 1990, 261: 39-58.","journal-title":"Clin Orthop Relat Res"},{"key":"80_CR26","doi-asserted-by":"crossref","first-page":"102","DOI":"10.1097\/00003086-199212000-00015","volume":"285","author":"JA D'Antonio","year":"1992","unstructured":"D'Antonio JA, Capello WN, Jaffe WL: Hydroxyapatite-coated hip implants: multicenter three-year clinical and roentgenographic results. Clin Orthop Relat Res. 1992, 285: 102-115.","journal-title":"Clin Orthop Relat Res"},{"key":"80_CR27","doi-asserted-by":"crossref","first-page":"85","DOI":"10.1302\/0301-620X.78B1.0780085","volume":"78","author":"I \u00d6nsten","year":"1996","unstructured":"\u00d6nsten I, Carlsson AS, Sanz\u00e9n L, Besjakov J: Migration and wear of a hydroxyapatite-coated hip prosthesis a controlled roentgen stereophotogrammetric study. J Bone Joint Surg Br. 1996, 78: 85-91.","journal-title":"J Bone Joint Surg Br"},{"key":"80_CR28","doi-asserted-by":"publisher","first-page":"641","DOI":"10.1302\/0301-620X.84B5.12384","volume":"84","author":"KA Lai","year":"2002","unstructured":"Lai KA, Shen WJ, Chen CH, Yang CY, Hu WP, Chang GL: Failure of hydroxyapatite-coated acetabular cups: ten-year follow-up of 85 Landos Atoll arthroplasties. J Bone Joint Surg Br. 2002, 84: 641-646. 10.1302\/0301-620X.84B5.12384.","journal-title":"J Bone Joint Surg Br"},{"key":"80_CR29","first-page":"399","volume":"19","author":"WN Capello","year":"1995","unstructured":"Capello WN, D'Antonio JA, Feinberg JR: Hydroxyapatite-coated stems in patients under 50 years old: clinical and radiographic results at five-year minimum follow-up. Orthop Trans. 1995, 19: 399-404.","journal-title":"Orthop Trans"},{"key":"80_CR30","doi-asserted-by":"publisher","first-page":"184","DOI":"10.1054\/arth.2002.29394","volume":"17","author":"KA Giannikas","year":"2002","unstructured":"Giannikas KA, Din R, Sadiq S, Dunningham TH: Medium-term results of the ABG total hip arthroplasty in young patients. J Arthroplasty. 2002, 17: 184-188. 10.1054\/arth.2002.29394.","journal-title":"J Arthroplasty"},{"key":"80_CR31","doi-asserted-by":"crossref","first-page":"169","DOI":"10.2106\/00004623-199702000-00002","volume":"79","author":"GS Tompkins","year":"1997","unstructured":"Tompkins GS, Jacobs JJ, Kull LR, Rosenberg AG, Galante JO: Primary total hip arthroplasty with a porous-coated acetabular component. Seven-to-ten year results. J Bone Joint Surg Am. 1997, 79: 169-176.","journal-title":"J Bone Joint Surg Am"},{"key":"80_CR32","doi-asserted-by":"crossref","first-page":"975","DOI":"10.2106\/00004623-199607000-00001","volume":"78","author":"H Latimer","year":"1996","unstructured":"Latimer H, Lachiewicz PF, Chapel H: Porous-coated acetabular components with screw fixartion. Five to ten-year results. J Bone Joint Surg Am. 1996, 78: 975-981.","journal-title":"J Bone Joint Surg Am"},{"key":"80_CR33","doi-asserted-by":"crossref","first-page":"19","DOI":"10.1097\/00003086-199401000-00005","volume":"298","author":"RD Bloebaum","year":"1994","unstructured":"Bloebaum RD, Beeks D, orr LD, Savory CG, DuPont J, Hofmann AA: Complication with hydroxyapatite particulate separation in total hip arthroplasty. Clin Orthop Relat Res. 1994, 298: 19-26.","journal-title":"Clin Orthop Relat Res"},{"key":"80_CR34","doi-asserted-by":"publisher","first-page":"267","DOI":"10.1302\/0301-620X.80B2.8316","volume":"80","author":"EW Morscher","year":"1998","unstructured":"Morscher EW, Hefti A, Aebi U: Severe osteolysis after third-body wear due to hydroxyapatite particles from acetabular cup coating. J Bone Joint Surg Br. 1998, 80: 267-272. 10.1302\/0301-620X.80B2.8316.","journal-title":"J Bone Joint Surg Br"},{"key":"80_CR35","doi-asserted-by":"crossref","first-page":"66","DOI":"10.2106\/00004623-199901000-00010","volume":"81","author":"JC Clohisy","year":"1999","unstructured":"Clohisy JC, Harris WH: The Harris-Galante porous coated acetabular component with screw fixation: an average ten year follow-up study. J Bone Joint Surg Am. 1999, 81: 66-73.","journal-title":"J Bone Joint Surg Am"},{"key":"80_CR36","doi-asserted-by":"crossref","first-page":"108","DOI":"10.1097\/00003086-198607000-00023","volume":"208","author":"RM Pilliar","year":"1986","unstructured":"Pilliar RM, Lee JM, Maniatopolous C: Observations on the effect of movement on bone ingrowth into porous-surfaced implants. Clin Orthop Relat Res. 1986, 108-113. 208","journal-title":"Clin Orthop Relat Res"},{"key":"80_CR37","doi-asserted-by":"publisher","first-page":"570","DOI":"10.1002\/jbm.1056","volume":"58","author":"Limin Sun","year":"2001","unstructured":"Sun Limin, Berndt Christopher, Gross Karlis, Kucuk Ahmet: Material Fundamentals and Clinical Performance of Plasma-Sprayed Hydroxyapatite Coatings: A Review. J Biomed Mater Res (Appl Biomater). 2001, 58: 570-592. 10.1002\/jbm.1056.","journal-title":"J Biomed Mater Res (Appl Biomater)"},{"key":"80_CR38","doi-asserted-by":"publisher","first-page":"548","DOI":"10.1002\/jor.1100050410","volume":"5","author":"DJ Rapperport","year":"1987","unstructured":"Rapperport DJ, Carter DR, Schurman DJ: Contact finite element stress analysis of porous ingrowth acetabular cup implantation, ingrowth, and loosening. J Orthop Res. 1987, 5: 548-561. 10.1002\/jor.1100050410.","journal-title":"J Orthop Res"},{"key":"80_CR39","doi-asserted-by":"crossref","first-page":"534","DOI":"10.1302\/0301-620X.77B4.7615595","volume":"77","author":"RG Geesink","year":"1995","unstructured":"Geesink RG, Hoefnagels NH: Six-year results of hydroxyapatite-coated total hip replacement. J Bone Joint Surg Br. 1995, 77: 534-547.","journal-title":"J Bone Joint Surg Br"},{"key":"80_CR40","doi-asserted-by":"crossref","first-page":"319","DOI":"10.2106\/00004623-199603000-00001","volume":"78","author":"RH Rothman","year":"1996","unstructured":"Rothman RH, Hozack WJ, Ranawat A, Moriarty L: Hydroxyapatite-coated femoral stems. A matched-pair analysis of coated and uncoated implants. J Bone Joint Surg Am. 1996, 78: 319-324.","journal-title":"J Bone Joint Surg Am"},{"key":"80_CR41","doi-asserted-by":"publisher","first-page":"167","DOI":"10.1016\/S0883-5403(09)80010-7","volume":"8","author":"TW Bauer","year":"1993","unstructured":"Bauer TW, Stulberg BN, Jiang M, Geesink RGT: Uncemented acetabular components, histologic analysis of retrieved hydroxyapatite coated and porous implants. J Arthroplasty. 1993, 8: 167-177.","journal-title":"J Arthroplasty"},{"key":"80_CR42","doi-asserted-by":"publisher","first-page":"389","DOI":"10.1016\/S0883-5403(06)80037-9","volume":"8","author":"JP Collier","year":"1993","unstructured":"Collier JP, Surprenant VA, Mayor MB, Wrona M, Jensen RE, Surprenant HP: Loss of hydroxyapatite coating on retrieved, total hip components. J Arthroplasty. 1993, 8: 389-393. 10.1016\/S0883-5403(06)80037-9.","journal-title":"J Arthroplasty"},{"key":"80_CR43","doi-asserted-by":"publisher","first-page":"253","DOI":"10.3109\/17453679408995449","volume":"65","author":"DC Hardy","year":"1994","unstructured":"Hardy DC, Frayssinet P, Bonel G, Authom T, Le Naelou SA, Delinc\u00e9 PE: Two-year outcome of hydroxyapatitecoated prostheses: two femoral prostheses retrieved at autopsy. Acta Orthop Scand. 1994, 65: 253-257.","journal-title":"Acta Orthop Scand"},{"key":"80_CR44","doi-asserted-by":"publisher","first-page":"389","DOI":"10.1016\/S0883-5403(05)80190-1","volume":"10","author":"P Buma","year":"1995","unstructured":"Buma P, Gardeniers JW: Tissue reactions around a hydroxyapatite-coated hip prostheses: case report of a retrieved specimen. J Arthroplasty. 1995, 10: 389-395. 10.1016\/S0883-5403(05)80190-1.","journal-title":"J Arthroplasty"},{"key":"80_CR45","first-page":"127","volume":"41","author":"RJ Friedman","year":"1992","unstructured":"Friedman RJ: Advances in biomaterials and factors affecting implant fixation. Instr Course Lect. 1992, 41: 127-136.","journal-title":"Instr Course Lect"},{"key":"80_CR46","doi-asserted-by":"publisher","first-page":"172","DOI":"10.1097\/00003086-199711000-00018","volume":"344","author":"TH Mallory","year":"1997","unstructured":"Mallory TH, Head WC, Lombardi AV: Tapered design for the cementless total hip arthroplasty femoral component. Clin Orthop Relat Res. 1997, 344: 172-178. 10.1097\/00003086-199711000-00018.","journal-title":"Clin Orthop Relat Res"},{"key":"80_CR47","doi-asserted-by":"crossref","first-page":"83","DOI":"10.1302\/0301-620X.74B1.1732272","volume":"74","author":"YH Kim","year":"1992","unstructured":"Kim YH, Kim VE: Results of the Harris-Galante cementless hip prosthesis. J Bone Joint Surg Br. 1992, 74: 83-87.","journal-title":"J Bone Joint Surg Br"},{"key":"80_CR48","doi-asserted-by":"crossref","first-page":"1439","DOI":"10.2106\/00004623-199173100-00001","volume":"73","author":"TW Bauer","year":"1991","unstructured":"Bauer TW, Geesink RC, Zimmerman R, McMahon JT: Hydroxyapatite-coated femoral stems. Histological analysis of components retrieved at autopsy. J Bone Joint Surg Am. 1991, 73: 1439-1452.","journal-title":"J Bone Joint Surg Am"},{"key":"80_CR49","doi-asserted-by":"publisher","first-page":"120","DOI":"10.1097\/00003086-199909000-00016","volume":"366","author":"AJ Yee","year":"1999","unstructured":"Yee AJ, Kreder HK, Bookman I, Davey JR: A randomized trial of hydroxyapatite coated prostheses in total hip arthroplasty. Clin Orthop Relat Res. 1999, 366: 120-132. 10.1097\/00003086-199909000-00016.","journal-title":"Clin Orthop Relat Res"},{"key":"80_CR50","doi-asserted-by":"crossref","first-page":"568","DOI":"10.1302\/0301-620X.76B4.8027142","volume":"76","author":"OL Huk","year":"1994","unstructured":"Huk OL, Bansal M, Betts F, Rimnac CM, Lieberman JR, Huo MH, Salvati EA: Polyethylene and metal debris generated by nonarticulating surfaces of modular acetabular components. J Bone Joint Surg Br. 1994, 76: 568-574.","journal-title":"J Bone Joint Surg Br"},{"key":"80_CR51","doi-asserted-by":"crossref","first-page":"1013","DOI":"10.2106\/00004623-199707000-00007","volume":"79","author":"RD Bloebaum","year":"1997","unstructured":"Bloebaum RD, Mihalopoulus NL, Jensen JW, Dorr LD: Post-mortem analysis of bone growth into porous-coated acetabular components. J Bone Joint Surg Am. 1997, 79: 1013-1022.","journal-title":"J Bone Joint Surg Am"}],"container-title":["Journal of Orthopaedic Surgery and Research"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1186\/1749-799X-3-35.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1186\/1749-799X-3-35\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1186\/1749-799X-3-35.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,2,29]],"date-time":"2024-02-29T03:49:11Z","timestamp":1709178551000},"score":1,"resource":{"primary":{"URL":"https:\/\/josr-online.biomedcentral.com\/articles\/10.1186\/1749-799X-3-35"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2008,8,7]]},"references-count":51,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2008,12]]}},"alternative-id":["80"],"URL":"https:\/\/doi.org\/10.1186\/1749-799x-3-35","relation":{},"ISSN":["1749-799X"],"issn-type":[{"value":"1749-799X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2008,8,7]]},"article-number":"35"}}