{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,7]],"date-time":"2026-10-07T17:01:45Z","timestamp":1791392505111,"version":"4.3.3"},"reference-count":32,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2009,4,9]],"date-time":"2009-04-09T00:00:00Z","timestamp":1239235200000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/2.0"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J Orthop Surg Res"],"published-print":{"date-parts":[[2009,12]]},"DOI":"10.1186\/1749-799x-4-10","type":"journal-article","created":{"date-parts":[[2009,4,9]],"date-time":"2009-04-09T14:13:25Z","timestamp":1239286405000},"source":"Crossref","is-referenced-by-count":73,"title":["In vivo evaluation of a vibration analysis technique for the per-operative monitoring of the fixation of hip prostheses"],"prefix":"10.1186","volume":"4","author":[{"given":"Leonard C","family":"Pastrav","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Siegfried V N","family":"Jaecques","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ilse","family":"Jonkers","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Georges","family":"Van der Perre","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Michiel","family":"Mulier","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2009,4,9]]},"reference":[{"key":"107_CR1","doi-asserted-by":"publisher","first-page":"433","DOI":"10.1080\/000164700317381081","volume":"71","author":"U Lucht","year":"2000","unstructured":"Lucht U: The Danish Hip Arthroplasty Register. Acta Orthop Scand. 2000, 71: 433-439. 10.1080\/000164700317381081.","journal-title":"Acta Orthop Scand"},{"key":"107_CR2","doi-asserted-by":"crossref","first-page":"802","DOI":"10.1302\/0301-620X.78B5.0780802","volume":"78","author":"AR Britton","year":"1996","unstructured":"Britton AR, Murray DW, Bulstrode CJ, McPherson K, Denham RA: Long-term comparison of Charnley and Stanmore design total hip replacements. J Bone Joint Surg Br. 1996, 78: 802-808.","journal-title":"J Bone Joint Surg Br"},{"key":"107_CR3","doi-asserted-by":"crossref","first-page":"517","DOI":"10.2106\/00004623-198567040-00003","volume":"67","author":"BF Kavanagh","year":"1985","unstructured":"Kavanagh BF, Ilstrup DM, Fitzgerald RH: Revision total hip arthroplasty. J Bone Joint Surg Am. 1985, 67: 517-526.","journal-title":"J Bone Joint Surg Am"},{"key":"107_CR4","doi-asserted-by":"crossref","first-page":"1169","DOI":"10.3928\/0147-7447-19971201-12","volume":"20","author":"B Mj\u00f6berg","year":"1997","unstructured":"Mj\u00f6berg B: The theory of early loosening of hip prostheses. Orthopedics. 1997, 20: 1169-1175.","journal-title":"Orthopedics"},{"key":"107_CR5","doi-asserted-by":"publisher","first-page":"285","DOI":"10.1002\/jor.1100100216","volume":"10","author":"K S\u00f8balle","year":"1992","unstructured":"S\u00f8balle K, Hansen ES, Rassmussen HB, Jorgensen PH, Bunger C: Tissue ingrowth into titanium and hydroxyapatite-coated implants during stable and unstable mechanical conditions. J Orthop Res. 1992, 10: 285-299. 10.1002\/jor.1100100216.","journal-title":"J Orthop Res"},{"key":"107_CR6","doi-asserted-by":"crossref","first-page":"480","DOI":"10.2106\/00004623-200403000-00004","volume":"86-A","author":"RM Meek","year":"2004","unstructured":"Meek RM, Garbuz DS, Masri BA, Greidanus NV, Duncan CP: Intraoperative fracture of the femur in revision total hip arthroplasty with a diaphyseal fitting stem. J Bone Joint Surg Am. 2004, 86-A: 480-485.","journal-title":"J Bone Joint Surg Am"},{"key":"107_CR7","doi-asserted-by":"publisher","first-page":"689","DOI":"10.1016\/0021-9290(93)90032-A","volume":"26","author":"G Lowet","year":"1993","unstructured":"Lowet G, Van Audekercke R, Perre Van der G, Geusens P, Dequeker J, Lammens J: The relation between resonant frequencies and torsional stiffness of long bones in vitro. Validation of a simple beam model. J Biomech. 1993, 26: 689-696. 10.1016\/0021-9290(93)90032-A.","journal-title":"J Biomech"},{"key":"107_CR8","doi-asserted-by":"publisher","first-page":"1255","DOI":"10.1016\/0021-9290(96)00054-1","volume":"29","author":"G Lowet","year":"1996","unstructured":"Lowet G, Perre Van der G: Ultrasound velocity measurement in long bones: measurement method and simulation of ultrasound wave propagation. J Biomech. 1996, 29: 1255-1262. 10.1016\/0021-9290(96)00054-1.","journal-title":"J Biomech"},{"key":"107_CR9","doi-asserted-by":"publisher","first-page":"549","DOI":"10.1016\/0021-9290(83)90069-6","volume":"16","author":"G Van der Perre","year":"1983","unstructured":"Perre Van der G, Cornelissen P: On the mechanical resonance of a human tibia in vitro. J Biomech. 1983, 16: 549-10.1016\/0021-9290(83)90069-6.","journal-title":"J Biomech"},{"issue":"3","key":"107_CR10","doi-asserted-by":"publisher","first-page":"244","DOI":"10.1115\/1.3138412","volume":"105","author":"G Van der Perre","year":"1983","unstructured":"Perre Van der G, Van Audekercke R, Martens M, Mulier JC: Identification of in vivo vibration modes of human tibia by modal analysis. J Biomech Eng. 1983, 105 (3): 244-248.","journal-title":"J Biomech Eng"},{"key":"107_CR11","doi-asserted-by":"publisher","first-page":"323","DOI":"10.1016\/0021-9290(90)90060-G","volume":"23","author":"G Nikiforidis","year":"1990","unstructured":"Nikiforidis G, Bezerianos A, Dimarogonas A, Sutherland C: Monitoring of fracture healing by lateral and axial vibration analysis. J Biomech. 1990, 23: 323-330. 10.1016\/0021-9290(90)90060-G.","journal-title":"J Biomech"},{"key":"107_CR12","first-page":"151","volume-title":"Micromovement in Orthopaedics","author":"J Collier","year":"1993","unstructured":"Collier J, Donarski J, Worley J, Lay A: The use of externally applied mechanical vibrations to assess both fractures and hip prosthesis. Micromovement in Orthopaedics. Edited by: Turner-Smith R. 1993, Oxford Univ. Press, 151-163."},{"key":"107_CR13","doi-asserted-by":"publisher","first-page":"50","DOI":"10.1097\/00005131-199601000-00008","volume":"10","author":"Y Nakatsuchi","year":"1996","unstructured":"Nakatsuchi Y, Tsuchikane A, Nomura A: Assessment of fracture healing in the tibia using the impulse response method. J Orthop Trauma. 1996, 10: 50-62. 10.1097\/00005131-199601000-00008.","journal-title":"J Orthop Trauma"},{"issue":"1 Suppl","key":"107_CR14","doi-asserted-by":"publisher","first-page":"29S","DOI":"10.1016\/8756-3282(95)00377-0","volume":"18","author":"G Van der Perre","year":"1996","unstructured":"Perre Van der G, Lowet G: In vivo assessment of bone mechanical properties by vibration and ultrasonic wave propagation analysis. Bone. 1996, 18 (1 Suppl): 29S-35S.","journal-title":"Bone"},{"key":"107_CR15","doi-asserted-by":"publisher","first-page":"226","DOI":"10.1034\/j.1600-0501.1997.080309.x","volume":"8","author":"N Meredith","year":"1997","unstructured":"Meredith N, Book K, Friberg B, Jemt T, Sennerby L: Resonance frequency measurements of implant stability in vivo. A cross-sectional and longitudinal study of resonance frequency measurements on implants in the edentulous and partially dentate maxilla. Clin Oral Implants Res. 1997, 8: 226-233. 10.1034\/j.1600-0501.1997.080309.x.","journal-title":"Clin Oral Implants Res"},{"key":"107_CR16","first-page":"1406","volume":"27","author":"F Burny","year":"2000","unstructured":"Burny F, Donkerwolcke M, Moulart F, Borgwardt A, Vryzakis P, Pichon D, Collier R, Louridas S, Perre Van der G, Denayer I, Jaecques S, Catrysse M, Puers R: STIMuLus: Smart Total Implant for the Monitoring of Loosening [abstract]. Medical Physics. 2000, 27: 1406-","journal-title":"Medical Physics"},{"key":"107_CR17","doi-asserted-by":"publisher","first-page":"315","DOI":"10.1016\/S0268-0033(01)00002-X","volume":"16","author":"AP Georgiou","year":"2001","unstructured":"Georgiou AP, Cunningham JL: Accurate diagnosis of hip prosthesis loosening using a vibrational technique. Clin Biomech (Bristol, Avon). 2001, 16: 315-323. 10.1016\/S0268-0033(01)00002-X.","journal-title":"Clin Biomech (Bristol, Avon)"},{"key":"107_CR18","doi-asserted-by":"publisher","first-page":"77","DOI":"10.1243\/PIME_PROC_1989_203_014_01","volume":"203","author":"AD Rosenstein","year":"1989","unstructured":"Rosenstein AD, McCoy GF, Bulstrode CJ, McLardy-Smith PD, Cunningham JL, Turner Smith AR: The differentiation of loose and secure femoral implants in total hip replacement using a vibrational technique: an anatomical and pilot clinical study. Proc Inst Mech Eng [H]. 1989, 203: 77-81.","journal-title":"Proc Inst Mech Eng [H]"},{"key":"107_CR19","doi-asserted-by":"publisher","first-page":"278","DOI":"10.1016\/j.medengphy.2007.04.017","volume":"30","author":"A Rowlands","year":"2008","unstructured":"Rowlands A, Duck FA, Cunningham JL: Bone vibration measurement using ultrasound: Application to detection of hip prosthesis loosening. Med Eng Phys. 2008, 30: 278-284. 10.1016\/j.medengphy.2007.04.017.","journal-title":"Med Eng Phys"},{"key":"107_CR20","doi-asserted-by":"publisher","first-page":"886","DOI":"10.1016\/j.medengphy.2006.09.011","volume":"29","author":"M Lannocca","year":"2007","unstructured":"Lannocca M, Varini E, Cappello A, Cristofolini L, Bialoblocka E: Intra-operative evaluation of cementless hip implant stability: A prototype device based on vibration analysis. Med Eng Phys. 2007, 29: 886-894. 10.1016\/j.medengphy.2006.09.011.","journal-title":"Med Eng Phys"},{"key":"107_CR21","first-page":"443","volume-title":"Proceedings of ISMA 2004 International Conference on Noise and vibration engineering: 20\u201322 September 2004; Leuven","author":"S Jaecques","year":"2004","unstructured":"Jaecques S, Pastrav C, Zahariuc A, Perre Van der G: Analysis of the fixation quality of cementless hip prostheses using a vibrational technique. Proceedings of ISMA 2004 International Conference on Noise and vibration engineering: 20\u201322 September 2004; Leuven. Edited by: Sas P, De Munck M. 2004, Leuven: K.U. Leuven, 443-456."},{"key":"107_CR22","first-page":"92","volume-title":"EORS \u2013 Transactions, Proceedings of 15th Annual Meeting of European Orthopaedic Research Society \u2013 EORS 2005; Lisbon","author":"S Jaecques","year":"2005","unstructured":"Jaecques S, Pastrav C, Mulier M, Perre Van der G: Determination of THR stem insertion endpoint by vibrational analysis. EORS \u2013 Transactions, Proceedings of 15th Annual Meeting of European Orthopaedic Research Society \u2013 EORS 2005; Lisbon. Edited by: Cabral R, Cassiano NM, Camilo C. 2005, Lisbon: Soc Portugesa de Ortopedia e Traumatologia, 92-"},{"key":"107_CR23","first-page":"505","volume-title":"Proceedings of TEHNOMUS XIII, the 13th International conference on New technologies and products in machine manufacturing technology: 6\u20137 May 2005; Suceava","author":"C Pastrav","year":"2005","unstructured":"Pastrav C, Jaecques S, Deloge G, Mulier M, Perre Van der G: A system for intra operative manufacturing and stability testing of hip prostheses. Proceedings of TEHNOMUS XIII, the 13th International conference on New technologies and products in machine manufacturing technology: 6\u20137 May 2005; Suceava. Edited by: Dumitru I. 2005, Suceava: University of Suceava, 505-510."},{"key":"107_CR24","first-page":"23","volume":"6","author":"LC Pastrav","year":"2008","unstructured":"Pastrav LC, Jaecques SVN, Mulier M, Va der Perre G: Detection of the insertion end point of cementless hip prostheses using the comparison between successive frequency response functions. Journal of Applied Biomaterials & Biomechanics. 2008, 6: 23-29.","journal-title":"Journal of Applied Biomaterials & Biomechanics"},{"key":"107_CR25","first-page":"35","volume-title":"Proceedings of the International seminar Prediction and evaluation of total hip replacement performance: can we plan success? 22\u201323 June 2007; Leuven","author":"J Devos","year":"2007","unstructured":"Devos J, Jaecques S, Pastrav C, Perre Van der G: The influence of contact conditions on resonance frequencies of a hip stem-femur system: a finite element analysis. Proceedings of the International seminar Prediction and evaluation of total hip replacement performance: can we plan success? 22\u201323 June 2007; Leuven. Edited by: Jonkers I, Jaecques S, Mulier M, Van der Perre G. 2007, Leuven: K.U. Leuven, 35-36."},{"issue":"5","key":"107_CR26","doi-asserted-by":"publisher","first-page":"444","DOI":"10.1016\/S0268-0033(03)00051-2","volume":"18","author":"G Qi","year":"2003","unstructured":"Qi G, Mouchon W, Tan TE: How much can a vibrational diagnostic tool reveal in total hip arthroplasty loosening?. Clin Biomech (Bristol, Avon). 2003, 18 (5): 444-458. 10.1016\/S0268-0033(03)00051-2.","journal-title":"Clin Biomech (Bristol, Avon)."},{"key":"107_CR27","doi-asserted-by":"crossref","first-page":"97","DOI":"10.1097\/00003086-198912000-00012","volume":"249","author":"JC Mulier","year":"1989","unstructured":"Mulier JC, Mulier M, Brady LP, Steenhoudt H, Cauwe Y, Goossens M, Elloy M: A new system to produce intraoperatively custom femoral prosthesis from measurements taken during the surgical procedure. Clin Orthop Relat Res. 1989, 249: 97-112.","journal-title":"Clin Orthop Relat Res"},{"key":"107_CR28","volume-title":"Modal Analysis Theory and Testing","author":"W Heylen","year":"1997","unstructured":"Heylen W, Lammens S, Sas P: Modal Analysis Theory and Testing. 1997, Leuven: K.U. Leuven, Belgium"},{"key":"107_CR29","first-page":"28","volume-title":"Proceedings of the International seminar Prediction and evaluation of total hip replacement performance: can we plan success? 22\u201323 June 2007; Leuven","author":"A Asiminei","year":"2007","unstructured":"Asiminei A, Pastrav C, Jaecques S, Mulier M, Perre Van der G: Intraoperative manufactured hip prosthesis insertion \u2013 a finite element simulation. Proceedings of the International seminar Prediction and evaluation of total hip replacement performance: can we plan success? 22\u201323 June 2007; Leuven. Edited by: Jonkers I, Jaecques S, Mulier M, Van der Perre G. 2007, Leuven: K.U. Leuven, 28-30."},{"key":"107_CR30","first-page":"6","volume-title":"Proceedings of the International seminar Prediction and evaluation of total hip replacement performance: can we plan success? 22\u201323 June 2007; Leuven","author":"W Claassen","year":"2007","unstructured":"Claassen W, Nijs J, Jaecques S, Perre Van der G, Mulier M: Early periprosthetic bone remodelling around cemented and uncemented custom-made femoral components and their uncemented acetabular cups. Proceedings of the International seminar Prediction and evaluation of total hip replacement performance: can we plan success? 22\u201323 June 2007; Leuven. Edited by: Jonkers I, Jaecques S, Mulier M, Van der Perre G. 2007, Leuven: K.U. Leuven, 6-8."},{"key":"107_CR31","first-page":"2","volume-title":"Proceedings of the International seminar Prediction and evaluation of total hip replacement performance: can we plan success? 22\u201323 June 2007; Leuven","author":"W Claassen","year":"2007","unstructured":"Claassen W, Nijs J, Mulier M, Jaecques S, Perre Van der G: Follow-up of implant performance using RSA. Proceedings of the International seminar Prediction and evaluation of total hip replacement performance: can we plan success? 22\u201323 June 2007; Leuven. Edited by: Jonkers I, Jaecques S, Mulier M, Van der Perre G. 2007, Leuven: K.U. Leuven, 2-5."},{"key":"107_CR32","volume-title":"Theory and Problems of Statistics","author":"MR Spiegel","year":"1972","unstructured":"Spiegel MR: Theory and Problems of Statistics. 1972, New York: McGraw-Hill Publishing Co Ltd"}],"container-title":["Journal of Orthopaedic Surgery and Research"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1186\/1749-799X-4-10.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1186\/1749-799X-4-10\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1186\/1749-799X-4-10.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,3,12]],"date-time":"2024-03-12T10:41:56Z","timestamp":1710240116000},"score":1,"resource":{"primary":{"URL":"https:\/\/josr-online.biomedcentral.com\/articles\/10.1186\/1749-799X-4-10"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2009,4,9]]},"references-count":32,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2009,12]]}},"alternative-id":["107"],"URL":"https:\/\/doi.org\/10.1186\/1749-799x-4-10","relation":{},"ISSN":["1749-799X"],"issn-type":[{"value":"1749-799X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2009,4,9]]},"article-number":"10"}}