{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,27]],"date-time":"2026-06-27T23:23:13Z","timestamp":1782602593860,"version":"3.54.5"},"reference-count":21,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2011,5,24]],"date-time":"2011-05-24T00:00:00Z","timestamp":1306195200000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["J Cardiothorac Surg"],"published-print":{"date-parts":[[2011,12]]},"abstract":"<jats:title>Abstract<\/jats:title>\n          <jats:sec>\n            <jats:title>Background<\/jats:title>\n            <jats:p>We report a case of delayed endovascular correction of graft collapse occurred after emergent Thoracic Endovascular Aortic Repair (TEVAR) for traumatic aortic isthmus rupture.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Case presentation<\/jats:title>\n            <jats:p>In 7<jats:sup>th<\/jats:sup> post-operative day after emergent TEVAR for traumatic aortic isthmus rupture (Gore TAG<jats:sup>\u00ae<\/jats:sup> 28-150), a partial collapse of the endoprosthesis at the descending tract occurred, with no signs of visceral ischemia. Considering patient's clinical conditions, the graft collapse wasn't treated at that time. When general conditions allowed reintervention, the patient refused any new treatment, so he was discharged.<\/jats:p>\n            <jats:p>Four months later the patient complainted for severe gluteal and sural claudication, erectile disfunction and abdominal angina; endovascular correction was performed. At 18 months the graft was still patent.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Discussion and Conclusion<\/jats:title>\n            <jats:p>Graft collapse after TEVAR is a rare event, which should be detected and treated as soon as possible. Delayed correction of this complication can be lethal due to the risk of visceral ischemia and limbs loss.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1186\/1749-8090-6-76","type":"journal-article","created":{"date-parts":[[2011,5,24]],"date-time":"2011-05-24T18:17:30Z","timestamp":1306261050000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":4,"title":["Delayed endovascular treatment of descending aorta stent graft collapse in a patient treated for post- traumatic aortic rupture: a case report"],"prefix":"10.1186","volume":"6","author":[{"given":"Giovanni","family":"Nano","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Daniela","family":"Mazzaccaro","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Giovanni","family":"Malacrida","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Maria Teresa","family":"Occhiuto","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Silvia","family":"Stegher","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Domenico G","family":"Tealdi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2011,5,24]]},"reference":[{"key":"433_CR1","unstructured":"Bertrand S, Cuny S, Petit P, Trosseille X, Page Y, Guillemot H, Drazetic P: Traumatic rupture of thoracic aorta in real-world motor vehicle crashes. Traffic Inj Prev."},{"issue":"6","key":"433_CR2","doi-asserted-by":"publisher","first-page":"1403","DOI":"10.1016\/j.jvs.2009.02.234","volume":"49","author":"A Azizzadeh","year":"2009","unstructured":"Azizzadeh A, Keyhani K, Miller CC, Coogan SM, Safi HJ, Estrera AL: Blunt traumatic aortic injury: initial experience with endovascular repair. J Vasc Surg. 2009, 49 (6): 1403-8. 10.1016\/j.jvs.2009.02.234.","journal-title":"J Vasc Surg"},{"key":"433_CR3","doi-asserted-by":"publisher","first-page":"228","DOI":"10.1016\/j.jvs.2004.03.051","volume":"40","author":"CJ Hansen","year":"2004","unstructured":"Hansen CJ, Bui H, Donayre CE, Aziz I, Kim B, Kopchok G, Walot I, Lee J, Lippmann M, White RA: Complications of endovascular repair of high-risk and emergent descending thoracic aortic aneurysms and dissections. J Vasc Surg. 2004, 40: 228-34. 10.1016\/j.jvs.2004.03.051.","journal-title":"J Vasc Surg"},{"key":"433_CR4","doi-asserted-by":"publisher","first-page":"1143","DOI":"10.1016\/S0003-4975(02)03386-6","volume":"73","author":"CM Rodrigues Alves","year":"2002","unstructured":"Rodrigues Alves CM, da Fonseca JH, de Souza JA, Camargo Carvalho AC, Buffolo E: Endovascular treatment of thoracic disease: patient selection and a proposal of a risk score. Ann Thorac Surg. 2002, 73: 1143-8. 10.1016\/S0003-4975(02)03386-6.","journal-title":"Ann Thorac Surg"},{"issue":"5","key":"433_CR5","doi-asserted-by":"publisher","first-page":"1153","DOI":"10.1016\/j.jtcvs.2009.06.017","volume":"139","author":"L Canaud","year":"2010","unstructured":"Canaud L, Alric P, Desgranges P, Marzelle J, Marty-An\u00e9 C, Becquemin JP: Factors favoring stent-graft collapse after thoracic endovascular aortic repair. J Thorac Cardiovasc Surg. 2010, 139 (5): 1153-7. 10.1016\/j.jtcvs.2009.06.017.","journal-title":"J Thorac Cardiovasc Surg"},{"key":"433_CR6","doi-asserted-by":"publisher","first-page":"124","DOI":"10.1016\/S0741-5214(03)01034-6","volume":"39","author":"G Melissano","year":"2004","unstructured":"Melissano G, Tshomba Y, Civilini E, Chiesa R: Disappointing results with a new commercially available thoracic endograft. J Vasc Surg. 2004, 39: 124-30. 10.1016\/S0741-5214(03)01034-6.","journal-title":"J Vasc Surg"},{"key":"433_CR7","doi-asserted-by":"publisher","first-page":"503","DOI":"10.1583\/04-1515R.1","volume":"12","author":"MM Idu","year":"2005","unstructured":"Idu MM, Reekers JA, Balm R, Ponsen KJ, de Mol BAJM, Legemate DA: Collapse of a stent-graft following treatment of a traumatic thoracic aortic rupture. J Endovasc Ther. 2005, 12: 503-7. 10.1583\/04-1515R.1.","journal-title":"J Endovasc Ther"},{"key":"433_CR8","doi-asserted-by":"publisher","first-page":"1270","DOI":"10.1016\/j.jvs.2006.02.016","volume":"43","author":"G Mestres","year":"2006","unstructured":"Mestres G, Maeso J, Fernandez V, Matas M: Symptomatic collapse of a thoracic aorta endoprosthesis. J Vasc Surg. 2006, 43: 1270-3. 10.1016\/j.jvs.2006.02.016.","journal-title":"J Vasc Surg"},{"key":"433_CR9","doi-asserted-by":"publisher","first-page":"1096","DOI":"10.1016\/j.jvs.2006.01.034","volume":"43","author":"LL Hoornweg","year":"2006","unstructured":"Hoornweg LL, Dinkelman MK, Goslings JC, Reekers JA, Verhagen HJ, Verhoeven EL, Schurink GW, Balm R: Endovascular management of traumatic ruptures of the thoracic aorta: a retrospective multicenter analysis of 28 cases in the Netherlands. J Vasc Surg. 2006, 43: 1096-102. 10.1016\/j.jvs.2006.01.034.","journal-title":"J Vasc Surg"},{"key":"433_CR10","doi-asserted-by":"publisher","first-page":"873","DOI":"10.1016\/j.athoracsur.2006.04.012","volume":"82","author":"HY Tehrani","year":"2006","unstructured":"Tehrani HY, Peterson BG, Katariya K, Morasch MD, Stevens R, DiLuozzo G, Salerno T, Maurici G, Eton D, Eskandari MK: Endovascular repair of thoracic aortic tears. Ann Thoracic Surg. 2006, 82: 873-8. 10.1016\/j.athoracsur.2006.04.012.","journal-title":"Ann Thoracic Surg"},{"key":"433_CR11","doi-asserted-by":"publisher","first-page":"609","DOI":"10.1016\/j.jvs.2005.11.045","volume":"43","author":"MG Steinbauer","year":"2006","unstructured":"Steinbauer MG, Stehr A, Pfister K, Herold T, Zorger N, T\u00f6pel I, Paetzel C, Kasprzak PM: Endovascular repair of proximal endograft collapse after treatment for thoracic aortic disease. J Vasc Surg. 2006, 43: 609-12. 10.1016\/j.jvs.2005.11.045.","journal-title":"J Vasc Surg"},{"key":"433_CR12","doi-asserted-by":"publisher","first-page":"451","DOI":"10.1016\/j.ejvs.2007.06.005","volume":"34","author":"RJ Hinchliffe","year":"2007","unstructured":"Hinchliffe RJ, Krasznai A, Schultzekool L, Blankensteijn JD, Falkenberg M, L\u00f6nn L, Hausegger K, de Blas M, Egana JM, Sonesson B, Ivancev K: Observations on the failure of stent-grafts in the aortic arch. Eur J Vasc Endovasc Surg. 2007, 34: 451-6. 10.1016\/j.ejvs.2007.06.005.","journal-title":"Eur J Vasc Endovasc Surg"},{"key":"433_CR13","doi-asserted-by":"publisher","first-page":"928","DOI":"10.1016\/j.jvs.2007.06.049","volume":"46","author":"MR Go","year":"2007","unstructured":"Go MR, Barbato JE, Dillavou ED, Gupta N, Rhee RY, Makaroun MS, Cho JS: Thoracic endovascular aortic repair for traumatic aortic transection. J Vasc Surg. 2007, 46: 928-33. 10.1016\/j.jvs.2007.06.049.","journal-title":"J Vasc Surg"},{"key":"433_CR14","doi-asserted-by":"publisher","first-page":"780","DOI":"10.1016\/j.jvs.2007.03.059","volume":"46","author":"CD Rodd","year":"2007","unstructured":"Rodd CD, Desigan S, Hamady MS, Gibbs RG, Jenkins MP: Salvage options after stent collapse in the thoracic aorta. J Vasc Surg. 2007, 46: 780-5. 10.1016\/j.jvs.2007.03.059.","journal-title":"J Vasc Surg"},{"issue":"4","key":"433_CR15","doi-asserted-by":"publisher","first-page":"655","DOI":"10.1016\/j.jvs.2006.12.023","volume":"45","author":"BE Muhs","year":"2007","unstructured":"Muhs BE, Balm R, White GH, Verhagen HJ: Anatomic factors associated with acute endograft collapse after Gore TAG treatment of thoracic aortic dissection or traumatic rupture. J Vasc Surg. 2007, 45 (4): 655-61. 10.1016\/j.jvs.2006.12.023.","journal-title":"J Vasc Surg"},{"key":"433_CR16","doi-asserted-by":"publisher","first-page":"487","DOI":"10.1016\/j.jvs.2006.11.038","volume":"45","author":"DG Neschis","year":"2007","unstructured":"Neschis DG, Moaine S, Gutta R, Charles K, Scalea TM, Flinn WR, Griffith BP: Twenty consecutive cases of endograft repair of traumatic aortic disruption: Lessons learned. J Vasc Surg. 2007, 45: 487-92. 10.1016\/j.jvs.2006.11.038.","journal-title":"J Vasc Surg"},{"key":"433_CR17","doi-asserted-by":"publisher","first-page":"733","DOI":"10.1016\/j.jvs.2007.12.008","volume":"47","author":"L Canaud","year":"2008","unstructured":"Canaud L, Alric P, Branchereau P, Marty-An\u00e9 C, Berthet JP: Lessons learned from midterm follow-up of endovascular repair for traumatic rupture of the aortic isthmus. J Vasc Surg. 2008, 47: 733-8. 10.1016\/j.jvs.2007.12.008.","journal-title":"J Vasc Surg"},{"key":"433_CR18","doi-asserted-by":"publisher","first-page":"600","DOI":"10.1016\/j.jvir.2007.12.453","volume":"19","author":"DA Leung","year":"2008","unstructured":"Leung DA, Davis I, Katlaps G, Tisnado J, Sydnor MK, Komorowski DJ, Brinster D: Treatment of infolding related to the Gore TAG thoracic endoprosthesis. J Vasc Interv Radiol. 2008, 19: 600-5. 10.1016\/j.jvir.2007.12.453.","journal-title":"J Vasc Interv Radiol"},{"issue":"11 Suppl 1","key":"433_CR19","first-page":"II262","volume":"14;110","author":"A Bortone","year":"2004","unstructured":"Bortone A, De Cillis E, D'Agostino D, de Luca Tupputi Schinosa L: Endovascular treatment of thoracic aortic disease: four years of experience. Circulation. 2004, 14;110 (11 Suppl 1): II262-7.","journal-title":"Circulation"},{"issue":"3","key":"433_CR20","doi-asserted-by":"publisher","first-page":"337","DOI":"10.1016\/S1051-0443(97)70568-2","volume":"8","author":"CP Semba","year":"1997","unstructured":"Semba CP, Kato N, Kee ST, Lee GK, Mitchell RS, Miller DC, Dake MD: Acute rupture of the descending thoracic aorta: repair with use of endovascular stent-grafts. J Vasc Interv Radiol. 1997, 8 (3): 337-42. 10.1016\/S1051-0443(97)70568-2.","journal-title":"J Vasc Interv Radiol"},{"issue":"suppl II","key":"433_CR21","doi-asserted-by":"publisher","first-page":"II-39","DOI":"10.1177\/15266028020090S207","volume":"9","author":"J G\u00f6rich","year":"2002","unstructured":"G\u00f6rich J, Asquan Y, Seifarth H, Kr\u00e4mer S, Kapfer X, Orend KH, Sunder-Plassmann L, Pamler R: Initial experience with intentional stent-graft coverage of the subclavian artery during endovascular thoracic aortic repairs. J Endovasc Ther. 2002, 9 (suppl II): II-39-II-43.","journal-title":"J Endovasc Ther"}],"container-title":["Journal of Cardiothoracic Surgery"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1186\/1749-8090-6-76.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1186\/1749-8090-6-76\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1186\/1749-8090-6-76","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/1749-8090-6-76.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,9,1]],"date-time":"2021-09-01T14:04:59Z","timestamp":1630505099000},"score":1,"resource":{"primary":{"URL":"https:\/\/cardiothoracicsurgery.biomedcentral.com\/articles\/10.1186\/1749-8090-6-76"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2011,5,24]]},"references-count":21,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2011,12]]}},"alternative-id":["433"],"URL":"https:\/\/doi.org\/10.1186\/1749-8090-6-76","relation":{},"ISSN":["1749-8090"],"issn-type":[{"value":"1749-8090","type":"electronic"}],"subject":[],"published":{"date-parts":[[2011,5,24]]},"assertion":[{"value":"25 January 2011","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"24 May 2011","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"24 May 2011","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}}],"article-number":"76"}}