{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,31]],"date-time":"2026-07-31T18:16:31Z","timestamp":1785521791579,"version":"3.56.0"},"reference-count":56,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2013,4,18]],"date-time":"2013-04-18T00:00:00Z","timestamp":1366243200000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/2.0"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Source Code Biol Med"],"published-print":{"date-parts":[[2013,12]]},"DOI":"10.1186\/1751-0473-8-11","type":"journal-article","created":{"date-parts":[[2013,4,18]],"date-time":"2013-04-18T08:14:39Z","timestamp":1366272879000},"source":"Crossref","is-referenced-by-count":202,"title":["BioPatRec: A modular research platform for the control of artificial limbs based on pattern recognition algorithms"],"prefix":"10.1186","volume":"8","author":[{"given":"Max","family":"Ortiz-Catalan","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Rickard","family":"Br\u00e5nemark","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Bo","family":"H\u00e5kansson","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2013,4,18]]},"reference":[{"issue":"6","key":"91_CR1","doi-asserted-by":"publisher","first-page":"643","DOI":"10.1682\/JRRD.2010.09.0177","volume":"48","author":"EJ Scheme","year":"2011","unstructured":"Scheme EJ, Englehart K: Electromyogram pattern recognition for control of powered upper-limb prostheses: State of the art and challenges for clinical use. J Rehabil Res Dev. 2011, 48 (6): 643-10.1682\/JRRD.2010.09.0177.","journal-title":"J Rehabil Res Dev"},{"issue":"6","key":"91_CR2","doi-asserted-by":"publisher","first-page":"719","DOI":"10.1682\/JRRD.2010.08.0161","volume":"48","author":"B Peerdeman","year":"2011","unstructured":"Peerdeman B, Boere D, Witteveen H, Hermens H, Stramigioli S, Rietman H, Veltink P, Misra S: Myoelectric forearm prostheses: State of the art from a user-centered perspective. J Rehabil Res Dev. 2011, 48 (6): 719-738. 10.1682\/JRRD.2010.08.0161.","journal-title":"J Rehabil Res Dev"},{"key":"91_CR3","unstructured":"MATLAB version 7.13.0.564 (R2011b). Natick: The MathWorks Inc. 2011"},{"issue":"5","key":"91_CR4","doi-asserted-by":"publisher","first-page":"847","DOI":"10.1109\/TBME.2006.889192","volume":"54","author":"LJ Hargrove","year":"2007","unstructured":"Hargrove LJ, Englehart K, Hudgins B: A comparison of surface and intramuscular myoelectric signal classification. IEEE Trans Biomed Eng. 2007, 54 (5): 847-853.","journal-title":"IEEE Trans Biomed Eng"},{"key":"91_CR5","doi-asserted-by":"publisher","first-page":"65","DOI":"10.1109\/TBME.2008.2003293","volume":"56","author":"H Huang","year":"2009","unstructured":"Huang H, Kuiken T: A Strategy for Identifying Locomotion Modes Using Surface Electromyography. IEEE Trans Biomed Eng. 2009, 56: 65-73.","journal-title":"IEEE Trans Biomed Eng"},{"issue":"6","key":"91_CR6","doi-asserted-by":"publisher","first-page":"1698","DOI":"10.1109\/TBME.2011.2113182","volume":"58","author":"EJ Scheme","year":"2011","unstructured":"Scheme EJ, Englehart KB, Hudgins BS: Selective classification for improved robustness of myoelectric control under nonideal conditions. IEEE Trans Biomed Eng. 2011, 58 (6): 1698-705.","journal-title":"IEEE Trans Biomed Eng"},{"issue":"8","key":"91_CR7","doi-asserted-by":"publisher","first-page":"1956","DOI":"10.1109\/TBME.2008.919734","volume":"55","author":"MA Oskoei","year":"2008","unstructured":"Oskoei MA, Hu H: Support vector machine-based classification scheme for myoelectric control applied to upper limb. IEEE Trans Biomed Eng. 2008, 55 (8): 1956-1965.","journal-title":"IEEE Trans Biomed Eng"},{"key":"91_CR8","volume-title":"MyoElectric Controls\/Powered Prosthetics Symposium, Fredericton","author":"BA Lock","year":"2005","unstructured":"Lock BA, Englehart K, Hudgins B: Real-time myoelectric control in a virtual environment to relate usability vs. accuracy. MyoElectric Controls\/Powered Prosthetics Symposium, Fredericton. 2005, 17-19 Aug"},{"key":"91_CR9","doi-asserted-by":"publisher","first-page":"2","DOI":"10.1080\/03091900512331332546","volume":"30","author":"F Sebelius","year":"2006","unstructured":"Sebelius F, Eriksson L, Balkenius C, Laurell T: Myoelectric control of a computer animated hand: a new concept based on the combined use of a tree-structured artificial neural network and a data glove. J Med Eng Technol. 2006, 30: 2-10. 10.1080\/03091900512331332546.","journal-title":"J Med Eng Technol"},{"key":"91_CR10","volume-title":"MyoElectric Controls\/Powered Prosthetics Symposium, Fredericton","author":"EJ Scheme","year":"2008","unstructured":"Scheme EJ, Englehart K: A flexible user interface for rapid prototyping of advanced real-time myoelectric control schemes. MyoElectric Controls\/Powered Prosthetics Symposium, Fredericton. 2008, 13-15 Aug"},{"issue":"2","key":"91_CR11","doi-asserted-by":"publisher","first-page":"134","DOI":"10.1109\/TNSRE.2011.2178864","volume":"20","author":"R Davoodi","year":"2012","unstructured":"Davoodi R, Loeb GE: Real-time animation software for customized training to use motor prosthetic systems. IEEE Trans Neural Syst Rehabil Eng. 2012, 20 (2): 134-142.","journal-title":"IEEE Trans Neural Syst Rehabil Eng"},{"key":"91_CR12","volume-title":"30th Annu. Int. IEEE EMBS Conf","author":"W Bishop","year":"2008","unstructured":"Bishop W, Armiger R, Burck J, Bridges M, Hauschild M, Englehart K, Scheme EJ, Vogelstein RJ, Beaty J, Harshbarger S: A real-time virtual integration environment for the design and development of neural prosthetic systems. 30th Annu. Int. IEEE EMBS Conf. 2008, Vancouver"},{"issue":"6","key":"91_CR13","doi-asserted-by":"publisher","first-page":"619","DOI":"10.1001\/jama.2009.116","volume":"301","author":"TA Kuiken","year":"2009","unstructured":"Kuiken TA, Li G, Lock BA, Lipschutz RD, Miller LA, Stubblefield KA, Englehart KB: Targeted muscle reinnervation for real-time myoelectric control of multifunction artificial arms. J Am Med Assoc. 2009, 301 (6): 619-628. 10.1001\/jama.2009.116.","journal-title":"J Am Med Assoc"},{"issue":"6","key":"91_CR14","doi-asserted-by":"publisher","first-page":"619","DOI":"10.1682\/JRRD.2010.08.0149","volume":"48","author":"AM Simon","year":"2011","unstructured":"Simon AM, Hargrove LJ, Lock BA, Kuiken T: Target achievement control test: Evaluating real-time myoelectric pattern-recognition control of multifunctional upper-limb prostheses. J Rehabil Res Dev. 2011, 48 (6): 619-628. 10.1682\/JRRD.2010.08.0149.","journal-title":"J Rehabil Res Dev"},{"key":"91_CR15","unstructured":"Ortiz-Catalan M: BioPatRec. [ http:\/\/code.google.com\/p\/biopatrec ]"},{"key":"91_CR16","doi-asserted-by":"publisher","first-page":"48","DOI":"10.1109\/RBME.2010.2085429","volume":"3","author":"S Micera","year":"2010","unstructured":"Micera S, Carpaneto J, Raspopovic S: Control of hand prostheses using peripheral information. IEEE Rev Biomed Eng. 2010, 3: 48-68.","journal-title":"IEEE Rev Biomed Eng"},{"issue":"2","key":"91_CR17","doi-asserted-by":"publisher","first-page":"185","DOI":"10.1109\/TNSRE.2009.2039619","volume":"18","author":"G Li","year":"2010","unstructured":"Li G, Schultz AE, Kuiken T: Quantifying pattern recognition-based myoelectric control of multifunctional transradial prostheses. IEEE Trans Neural Syst Rehabil Eng. 2010, 18 (2): 185-192.","journal-title":"IEEE Trans Neural Syst Rehabil Eng"},{"issue":"3","key":"91_CR18","doi-asserted-by":"publisher","first-page":"239","DOI":"10.1109\/TNSRE.2011.2182525","volume":"20","author":"NE Bunderson","year":"2012","unstructured":"Bunderson NE, Kuiken T: Quantification of feature space changes with experience during electromyogram pattern recognition control. IEEE Trans Neural Syst Rehabil Eng. 2012, 20 (3): 239-246.","journal-title":"IEEE Trans Neural Syst Rehabil Eng"},{"issue":"2","key":"91_CR19","doi-asserted-by":"publisher","first-page":"186","DOI":"10.1109\/TNSRE.2010.2100828","volume":"19","author":"LH Smith","year":"2011","unstructured":"Smith LH, Hargrove LJ, Lock BA, Kuiken T: Determining the optimal window length for pattern recognition-based myoelectric control: balancing the competing effects of classification error and controller delay. IEEE Trans Neural Syst Rehabil Eng. 2011, 19 (2): 186-192.","journal-title":"IEEE Trans Neural Syst Rehabil Eng"},{"issue":"7","key":"91_CR20","doi-asserted-by":"publisher","first-page":"848","DOI":"10.1109\/TBME.2003.813539","volume":"50","author":"K Englehart","year":"2003","unstructured":"Englehart K, Hudgins B: A robust, real-time control scheme for multifunction myoelectric control. IEEE Trans Biomed Eng. 2003, 50 (7): 848-54. 10.1109\/TBME.2003.813539.","journal-title":"IEEE Trans Biomed Eng"},{"issue":"9","key":"91_CR21","doi-asserted-by":"publisher","first-page":"1849","DOI":"10.1007\/s10439-009-9737-7","volume":"37","author":"H Huang","year":"2009","unstructured":"Huang H, Zhou P, Li G, Kuiken T: Spatial filtering improves EMG classification accuracy following targeted muscle reinnervation. Ann Biomed Eng. 2009, 37 (9): 1849-1857. 10.1007\/s10439-009-9737-7.","journal-title":"Ann Biomed Eng"},{"issue":"3","key":"91_CR22","doi-asserted-by":"publisher","first-page":"270","DOI":"10.1109\/TNSRE.2009.2023282","volume":"17","author":"JW Sensinger","year":"2009","unstructured":"Sensinger JW, Ba Lock, Kuiken T: Adaptive pattern recognition of myoelectric signals: exploration of conceptual framework and practical algorithms. IEEE Trans Neural Syst Rehabil Eng. 2009, 17 (3): 270-278.","journal-title":"IEEE Trans Neural Syst Rehabil Eng"},{"issue":"4","key":"91_CR23","doi-asserted-by":"publisher","first-page":"424","DOI":"10.1109\/TNSRE.2010.2047590","volume":"18","author":"JJ Baker","year":"2010","unstructured":"Baker JJ, Scheme EJ, Englehart K, Hutchinson DT, Greger B: Continuous detection and decoding of dexterous finger flexions with implantable myoelectric sensors. IEEE Trans Neural Syst Rehabil Eng. 2010, 18 (4): 424-432.","journal-title":"IEEE Trans Neural Syst Rehabil Eng"},{"key":"91_CR24","volume-title":"33rd Annu. Int. Conf. IEEE EMxBS","author":"AM Simon","year":"2011","unstructured":"Simon AM, Hargrove LJ: A comparison of the effects of majority vote and a decision-based velocity ramp on real-time pattern recognition control. 33rd Annu. Int. Conf. IEEE EMxBS. 2011, Boston, 3350-3353. 30 Aug - 3 Sep"},{"key":"91_CR25","volume-title":"33rd Annu. Int. Conf. IEEE EMBS","author":"A Fougner","year":"2011","unstructured":"Fougner A, Scheme EJ, Chan ADC, Englehart K, Stavdahl O: A multi-modal approach for hand motion classification using surface EMG and accelerometers. 33rd Annu. Int. Conf. IEEE EMBS. 2011, Boston, 4247-4250. 30 Aug - 3 Sep"},{"key":"91_CR26","doi-asserted-by":"publisher","first-page":"82","DOI":"10.1109\/10.204774","volume":"40","author":"B Hudgins","year":"1993","unstructured":"Hudgins B, Parker P, Scott R: A new strategy for multifunction myoelectric control. IEEE Trans Biomed Eng. 1993, 40: 82-94. 10.1109\/10.204774.","journal-title":"IEEE Trans Biomed Eng"},{"issue":"6-7","key":"91_CR27","doi-asserted-by":"publisher","first-page":"431","DOI":"10.1016\/S1350-4533(99)00066-1","volume":"21","author":"K Englehart","year":"1999","unstructured":"Englehart K, Hudgins B, Parker P, Stevenson M: Classification of the myoelectric signal using time-frequency based representations. Med Eng Phys. 1999, 21 (6-7): 431-438. 10.1016\/S1350-4533(99)00066-1.","journal-title":"Med Eng Phys"},{"issue":"5","key":"91_CR28","doi-asserted-by":"publisher","first-page":"2974","DOI":"10.1152\/jn.00178.2007","volume":"98","author":"P Zhou","year":"2007","unstructured":"Zhou P, Lowery MM, Englehart KB, Huang H, L i G, Hargrove L, Dewald J, Kuiken T: Decoding a new neural machine interface for control of artificial limbs. J Neurophysiol. 2007, 98 (5): 2974-2982. 10.1152\/jn.00178.2007.","journal-title":"J Neurophysiol"},{"issue":"6","key":"91_CR29","doi-asserted-by":"publisher","first-page":"1410","DOI":"10.1109\/TBME.2009.2039480","volume":"57","author":"RN Khushaba","year":"2010","unstructured":"Khushaba RN, Al-Ani A, Al-Jumaily A: Orthogonal fuzzy neighborhood discriminant analysis for multifunction myoelectric hand control. IEEE Trans Biomed Eng. 2010, 57 (6): 1410-1419.","journal-title":"IEEE Trans Biomed Eng"},{"key":"91_CR30","doi-asserted-by":"crossref","unstructured":"Jiang N, Vest-Nielsen JL, Muceli S, Farina D: EMG-based simultaneous and proportional estimation of wrist\/hand dynamics in uni-Lateral trans-radial amputees. J Neuroengineering Rehabil. 2012, 9 (42).","DOI":"10.1186\/1743-0003-9-42"},{"key":"91_CR31","doi-asserted-by":"crossref","unstructured":"Poosapadi Arjunan S, Kumar DK: Decoding subtle forearm flexions using fractal features of surface Electromyogram from single and multiple sensors. J Neuroengineering Rehabil. 2010, 7 (53).","DOI":"10.1186\/1743-0003-7-53"},{"key":"91_CR32","doi-asserted-by":"crossref","unstructured":"L\u00f3pez NM, di Sciascio F, Soria CM, Valentinuzzi ME: Robust EMG sensing system based on data fusion for myoelectric control of a robotic arm. Biomed Eng Online. 2009, 8 (5).","DOI":"10.1186\/1475-925X-8-5"},{"key":"91_CR33","volume-title":"33rd Annu. Int. Conf. IEEE EMBS","author":"G Kanitz","year":"2011","unstructured":"Kanitz G, Antfolk C, Cipriani C: Decoding of individuated finger movements using surface EMG and input optimization applying a genetic algorithm. 33rd Annu. Int. Conf. IEEE EMBS. 2011, Boston, 1608-1611. 30 Aug - 3 Sep"},{"issue":"4","key":"91_CR34","doi-asserted-by":"publisher","first-page":"389","DOI":"10.3109\/17453677308989075","volume":"44","author":"P Herberts","year":"1973","unstructured":"Herberts P, Almstr\u00f6m C, Kadefors R, Lawrence PD: Hand prosthesis control via myoelectric patterns. Acta Orthopaedica Scandinavica. 1973, 44 (4): 389-409.","journal-title":"Acta Orthopaedica Scandinavica"},{"issue":"3","key":"91_CR35","doi-asserted-by":"publisher","first-page":"260","DOI":"10.1109\/TNSRE.2011.2108667","volume":"19","author":"C Cipriani","year":"2011","unstructured":"Cipriani C, Antfolk C, Controzzi M, Lundborg GN, Rosen B, Carrozza MC, Sebelius F: Online myoelectric control of a dexterous hand prosthesis by transradial amputees. IEEE Trans Neural Syst Rehabil Eng. 2011, 19 (3): 260-270.","journal-title":"IEEE Trans Neural Syst Rehabil Eng"},{"issue":"3","key":"91_CR36","doi-asserted-by":"publisher","first-page":"1128","DOI":"10.1109\/TBME.2007.909536","volume":"55","author":"P Shenoy","year":"2008","unstructured":"Shenoy P, Miller KJ, Crawford B, Rao RN: Online electromyographic control of a robotic prosthesis. IEEE Trans Biomed Eng. 2008, 55 (3): 1128-1135.","journal-title":"IEEE Trans Biomed Eng"},{"key":"91_CR37","volume-title":"33rd Annu. Int. Conf. IEEE EMBS","author":"H Mizuno","year":"2011","unstructured":"Mizuno H, Tsujiuchi N, Koizumi T: Forearm motion discrimination technique using real-time EMG signals. 33rd Annu. Int. Conf. IEEE EMBS. 2011, Boston, 4435-4438. 30 Aug - 3 Sep"},{"key":"91_CR38","volume-title":"33rd Annu. Int. Conf. IEEE EMBS","author":"J Zhong","year":"2011","unstructured":"Zhong J, Shi J, Cai Y, Zhang Q: Recognition of hand motions via surface EMG signal with rough entropy. 33rd Annu. Int. Conf. IEEE EMBS. 2011, Boston, 4100-4103. 30 Aug - 3 Sep"},{"key":"91_CR39","volume-title":"Principles of Multivariate Analysis: A User\u2019s Perspective","author":"W Krzanowski","year":"1988","unstructured":"Krzanowski W: Principles of Multivariate Analysis: A User\u2019s Perspective. 1988, New York: Oxford University Press"},{"key":"91_CR40","first-page":"4842","volume-title":"29th Annu. Int. Conf. IEEE EMBS Lyon","author":"L Hargrove","year":"2007","unstructured":"Hargrove L, Losier Y, Lock BA, Englehart K, Hudgins B: A real-time pattern recognition based myoelectric control usability study implemented in a virtual environment. 29th Annu. Int. Conf. IEEE EMBS Lyon. 2007, 4842-4845. 23-26 Aug"},{"key":"91_CR41","volume-title":"Neural Networks: A Comprehensive Foundation","author":"S Haykin","year":"1999","unstructured":"Haykin S: Neural Networks: A Comprehensive Foundation. 1999, Prentice Hall: Upper Saddle River"},{"key":"91_CR42","first-page":"15","volume":"V1","author":"T Achler","year":"2008","unstructured":"Achler T, Amir E: Input feedback networks: Classification and inference based on network structure. Artif Gen Intell Proc. 2008, V1: 15-26.","journal-title":"Artif Gen Intell Proc"},{"key":"91_CR43","doi-asserted-by":"publisher","first-page":"249","DOI":"10.1016\/S0925-2312(02)00343-0","volume":"44\u201346","author":"T Achler","year":"2002","unstructured":"Achler T: Input shunt networks. Neurocomputing. 2002, 44\u201346: 249-255.","journal-title":"Neurocomputing"},{"key":"91_CR44","volume-title":"Conference of the Canadian Medical & Biological Engineering Society","author":"A Chan","year":"2007","unstructured":"Chan A, Green G: Myoelectric control development toolbox. Conference of the Canadian Medical & Biological Engineering Society. 2007, Toronto, M0100-M0100."},{"key":"91_CR45","unstructured":"The BioSig Project. [ http:\/\/biosig.sourceforge.net\/index.html ]"},{"key":"91_CR46","volume-title":"Advances in Pattern Recognition","author":"IT Nabney","year":"2002","unstructured":"Nabney IT: NETLAB: Algorithms for Pattern Recognition. Advances in Pattern Recognition. 2002, London: Springer"},{"key":"91_CR47","unstructured":"Murphy K: Bayes Net Toolbox for Matlab. [ http:\/\/code.google.com\/p\/bnt ]"},{"key":"91_CR48","unstructured":"Demanet L, Lexing Y: WaveAtom. [ http:\/\/waveatom.org\/software.html ]"},{"key":"91_CR49","first-page":"7","volume-title":"Proceedings of the IASTED International Conference, Biomedical Engineering, BioMed Innsbruck","author":"M Ortiz-Catalan","year":"2012","unstructured":"Ortiz-Catalan M, Br\u00e5nemark R, H\u00e5kansson B: Biologically inspired algorithms applied to prosthetic control. Proceedings of the IASTED International Conference, Biomedical Engineering, BioMed Innsbruck. 2012, 7-15. 15-17, Feb"},{"issue":"3","key":"91_CR50","doi-asserted-by":"publisher","first-page":"645","DOI":"10.1109\/TBME.2011.2177662","volume":"59","author":"A Young","year":"2012","unstructured":"Young A, Hargrove L, Kuiken T: Improving myoelectric pattern recognition robustness to electrode shift by changing interelectrode distance and electrode configuration. IEEE Trans Biomed Eng. 2012, 59 (3): 645-652.","journal-title":"IEEE Trans Biomed Eng"},{"key":"91_CR51","doi-asserted-by":"crossref","unstructured":"Farf\u00e1n FD, Politti JC, Felice CJ: Evaluation of EMG processing techniques using information theory. Biomed Eng Online. 2010, 9 (72).","DOI":"10.1186\/1475-925X-9-72"},{"key":"91_CR52","first-page":"1","volume":"7","author":"J Demsar","year":"2006","unstructured":"Demsar J: Statistical comparisons of classifiers over multiple data sets. J Mach Learn Res. 2006, 7: 1-30.","journal-title":"J Mach Learn Res"},{"issue":"9","key":"91_CR53","doi-asserted-by":"publisher","first-page":"2537","DOI":"10.1109\/TBME.2011.2159216","volume":"58","author":"AJ Young","year":"2011","unstructured":"Young AJ, Hargrove LJ, Kuiken T: The effects of electrode size and orientation on the sensitivity of myoelectric pattern recognition systems to electrode shift. IEEE Trans Biomed Eng. 2011, 58 (9): 2537-2544.","journal-title":"IEEE Trans Biomed Eng"},{"issue":"4","key":"91_CR54","first-page":"283","volume":"13","author":"P Parker","year":"1986","unstructured":"Parker P, Scott R: Myoelectric control of prostheses. Crit Rev Biomed Eng. 1986, 13 (4): 283-310.","journal-title":"Crit Rev Biomed Eng"},{"key":"91_CR55","doi-asserted-by":"crossref","unstructured":"Ortiz-Catalan M, Br\u00e5nemark R, H\u00e5kansson B, Delbeke J: On the viability of implantable electrodes for the natural control of artificial limbs: Review and discussion. Biomed Eng Online. 2012, 11 (33).","DOI":"10.1186\/1475-925X-11-33"},{"key":"91_CR56","volume-title":"MyoElectric Controls\/Powered Prosthetics Symposium Fredericton","author":"B Lock","year":"2011","unstructured":"Lock B, Simon AM, Stubblefield K, Hargrove LJ: Prosthesis-guided training for practical use of pattern recognition control of prostheses. MyoElectric Controls\/Powered Prosthetics Symposium Fredericton. 2011, 14-19 Aug"}],"container-title":["Source Code for Biology and Medicine"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1186\/1751-0473-8-11.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1186\/1751-0473-8-11\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1186\/1751-0473-8-11.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2019,7,12]],"date-time":"2019-07-12T19:44:41Z","timestamp":1562960681000},"score":1,"resource":{"primary":{"URL":"https:\/\/scfbm.biomedcentral.com\/articles\/10.1186\/1751-0473-8-11"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2013,4,18]]},"references-count":56,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2013,12]]}},"alternative-id":["91"],"URL":"https:\/\/doi.org\/10.1186\/1751-0473-8-11","relation":{},"ISSN":["1751-0473"],"issn-type":[{"value":"1751-0473","type":"electronic"}],"subject":[],"published":{"date-parts":[[2013,4,18]]},"article-number":"11"}}