{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2023,10,14]],"date-time":"2023-10-14T15:43:09Z","timestamp":1697298189811},"reference-count":20,"publisher":"Springer Science and Business Media LLC","issue":"1","content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Patient Saf Surg"],"published-print":{"date-parts":[[2008,12]]},"abstract":"<jats:title>Abstract<\/jats:title>\n          <jats:sec>\n            <jats:title>Background<\/jats:title>\n            <jats:p>Totally implanted vascular access devices are frequently used in children for repeated blood samples or intravenous treatments. This prospective study aims at identifying the risk factors associated with infections, obstructions and surgical complications of these devices in pediatric patients.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Methods<\/jats:title>\n            <jats:p>From January 2006 to January 2008, all children older than one year of age with a diagnosis of solid or blood cell malignancy were included in the study. Insertion was performed by the surgeon according to a standardized protocol after landmark-guided puncture of the subclavian or internal jugular vein by a senior anesthesiologist. Dressing and post-operative care were standardized. Every manipulation was prospectively recorded by specialized dedicated nurses, and all patients were screened for complications one month post-surgery.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results<\/jats:title>\n            <jats:p>45 consecutive patients 1 to 16 years old were enrolled in the study. Mean age at the time of procedure was 8.5 years (range 1.3\u201315.6; SD \u00b1 4.88). There were 12 peroperative adverse events in 45 procedures (27%), detailed as follows: 3 pneumothoraces (7%), 3 hematomas (7%), 6 arterial punctures (13%). Among these events, intervention was necessary for two pneumothorax and one arterial puncture. There was no air embolism. At one month, we recorded 5 post-operative complications (11%): 2 thrombotic obstructions, one unsightly scar, and one scapular pain of unknown etiology. One patient needed repositioning of the catheter. There was no catheter-related infection.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusion<\/jats:title>\n            <jats:p>Prospective recording of TIVA insertion in children reveals a significant number of early incidents and complications, mainly associated with the percutaneous puncture technique. We found no infection in this series. Results of a longer follow-up in the same population are pending.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1186\/1754-9493-2-30","type":"journal-article","created":{"date-parts":[[2008,11,18]],"date-time":"2008-11-18T07:47:02Z","timestamp":1226994422000},"update-policy":"http:\/\/dx.doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":7,"title":["Incidents and complications of totally implanted vascular access devices in children: a prospective study"],"prefix":"10.1186","volume":"2","author":[{"given":"St\u00e9phane","family":"Tercier","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Christophe","family":"Gapany","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Manuel","family":"Diezi","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Chantal","family":"Cl\u00e9ment","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Katy","family":"Lemay","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jean-Marc","family":"Joseph","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2008,11,13]]},"reference":[{"issue":"4","key":"38_CR1","doi-asserted-by":"publisher","first-page":"377","DOI":"10.1002\/(SICI)1096-911X(199910)33:4<377::AID-MPO6>3.0.CO;2-X","volume":"33","author":"FD Munro","year":"1999","unstructured":"Munro FD, Gillett PM, Wratten JC, Shaw MP, Thomas A, MacKinlay Ga, Wallace WH: Totally implantable central venous access devices for paediatric oncology patients. Med Pediatr Oncol. 1999, 33 (4): 377-81. 10.1002\/(SICI)1096-911X(199910)33:4<377::AID-MPO6>3.0.CO;2-X.","journal-title":"Med Pediatr Oncol"},{"issue":"4","key":"38_CR2","doi-asserted-by":"crossref","first-page":"1267","DOI":"10.1200\/JCO.1999.17.4.1267","volume":"17","author":"EJ Bow","year":"1999","unstructured":"Bow EJ, Kilpatrick MG, Clinch JJ: Totally implantable venous access ports systems for patients receiving chemotherapy for solid tissue malignancies: A randomized controlled clinical trial examining the safety, efficacy, costs, and impact on quality of life. J Clin Oncol. 1999, 17 (4): 1267-","journal-title":"J Clin Oncol"},{"issue":"1","key":"38_CR3","doi-asserted-by":"publisher","first-page":"34","DOI":"10.1067\/mic.2003.29","volume":"31","author":"L Chang","year":"2003","unstructured":"Chang L, Tsai JS, Huang SJ, Shih CC: Evaluation of infectious complications of the implantable venous access system in a general oncologic population. Am J Infect Control. 2003, 31 (1): 34-39. 10.1067\/mic.2003.29.","journal-title":"Am J Infect Control"},{"issue":"10","key":"38_CR4","first-page":"397","volume":"60","author":"DA Koolen","year":"2002","unstructured":"Koolen DA, van Laarhoven HW, Wobbes T, Punt CJ: Single-centre experience with tunnelled central venous catheters in 150 cancer patients. Netherland Journal of Medicine. 2002, 60 (10): 397-401.","journal-title":"Netherland Journal of Medicine"},{"issue":"5","key":"38_CR5","first-page":"431","volume":"91","author":"JL Labourey","year":"2004","unstructured":"Labourey JL, Lacroix P, Genet D, Gobeaux F, Martin J, Venat-Bouvet L, Lavau-Denes S, Maubon A, Tubiana-Mathieu N: Thrombotic complications of implanted central venous access devices: prospective evaluation. Bull Cancer. 2004, 91 (5): 431-6.","journal-title":"Bull Cancer"},{"issue":"4","key":"38_CR6","doi-asserted-by":"publisher","first-page":"289","DOI":"10.1097\/00001622-200307000-00002","volume":"15","author":"CO Freytes","year":"2003","unstructured":"Freytes CO: Thromboembolic complications related to indwelling central venous catheters in children. Cur Opin Oncol. 2003, 15 (4): 289-92. 10.1097\/00001622-200307000-00002.","journal-title":"Cur Opin Oncol"},{"issue":"3","key":"38_CR7","doi-asserted-by":"publisher","first-page":"256","DOI":"10.1007\/s00520-001-0330-3","volume":"10","author":"C Barnes","year":"2002","unstructured":"Barnes C, Newall F, Monagle P: Thromboembolic complications related to indwelling central venous catheters in children with oncological\/haematological diseases: a retrospective study of 362 catheters. Support Care Cancer. 2002, 10 (3): 256-7. 10.1007\/s00520-001-0330-3.","journal-title":"Support Care Cancer"},{"issue":"11","key":"38_CR8","doi-asserted-by":"publisher","first-page":"805","DOI":"10.1007\/s00520-004-0607-4","volume":"12","author":"L Laurenzi","year":"2004","unstructured":"Laurenzi L, Natoli S, Benedetti C, Marcelli ME, Tirelli W, DiEmidio L, Arcuri E: Cutaneous bacterial colonization, modalities of chemotherapeutic infusion, and catheter-related bloodstream infection in totally implanted venous access devices. Support Care Cancer. 2004, 12 (11): 805-9. 10.1007\/s00520-004-0607-4.","journal-title":"Support Care Cancer"},{"issue":"6","key":"38_CR9","doi-asserted-by":"publisher","first-page":"722","DOI":"10.1016\/j.amjsurg.2004.08.041","volume":"188","author":"JT Carlo","year":"2004","unstructured":"Carlo JT, Lamont JP, McCarty TM, Livingston S, Kuhn JA: A prospective randomized trial demonstrating valved implantable ports have fewer complications and lower overall cost than nonvalved implantable ports. Am J Surg. 2004, 188 (6): 722-7. 10.1016\/j.amjsurg.2004.08.041.","journal-title":"Am J Surg"},{"issue":"2","key":"38_CR10","doi-asserted-by":"publisher","first-page":"205","DOI":"10.1097\/01.sla.0000133083.54934.ae","volume":"240","author":"D Dindo","year":"2004","unstructured":"Dindo D, Demartines N, Clavien PA: Classification of Surgical Complications. A New Proposal With Evaluation in a Cohort of 6336 Patients and Results of a Survey. Ann Surg. 2004, 240 (2): 205-213. 10.1097\/01.sla.0000133083.54934.ae.","journal-title":"Ann Surg"},{"key":"38_CR11","doi-asserted-by":"publisher","first-page":"50","DOI":"10.1007\/s003830200011","volume":"18","author":"R Babu","year":"2002","unstructured":"Babu R, Spicer RD: Implanted cascular access devices (ports) in children: compications and their prevention. Pediatr Surg Int. 2002, 18: 50-53. 10.1007\/s003830200011.","journal-title":"Pediatr Surg Int"},{"key":"38_CR12","doi-asserted-by":"publisher","first-page":"24","DOI":"10.1002\/jso.20410","volume":"93","author":"CM Seiler","year":"2006","unstructured":"Seiler CM, Frohlich BE, Dorsam UL, Kienle P, Buchler MW, Knaebel HP: Surgical Technique for Totally Implantable Access Ports (TAIP) Needs Improvement: A Multivariate Analysis of 400 Patients. J Surg Oncol. 2006, 93: 24-29. 10.1002\/jso.20410.","journal-title":"J Surg Oncol"},{"key":"38_CR13","doi-asserted-by":"publisher","first-page":"71","DOI":"10.1097\/00000542-199907000-00013","volume":"91","author":"ST Verghese","year":"1999","unstructured":"Verghese ST, McGill WA, Patel RI, Sell JE, Midgley FM, Ruttimann UE: Ultrasound-guided internal jugular venous cannulation in Infants. Anaesth. 1999, 91: 71-77. 10.1097\/00000542-199907000-00013.","journal-title":"Anaesth"},{"issue":"4","key":"38_CR14","doi-asserted-by":"publisher","first-page":"509","DOI":"10.1093\/bja\/aem041","volume":"98","author":"T Pirotte","year":"2007","unstructured":"Pirotte T, Veyckemans F: Ultrasound-guided subclavian vein cannulation in infants and chiildren: a novel approach. Br J Anaesth. 2007, 98 (4): 509-14. 10.1093\/bja\/aem041.","journal-title":"Br J Anaesth"},{"key":"38_CR15","doi-asserted-by":"publisher","first-page":"953","DOI":"10.1111\/j.1460-9592.2005.01609.x","volume":"15","author":"G Leyvi","year":"2005","unstructured":"Leyvi G, Taylor DG, Reith E, Wasnick JD: Utility of ultrasound-guided central venous cannulation in pediatric surgical patients: a clinical series. Pediatr Anesth. 2005, 15: 953-958. 10.1111\/j.1460-9592.2005.01609.x.","journal-title":"Pediatr Anesth"},{"key":"38_CR16","first-page":"49","volume-title":"Technology Appraisal Guidance","author":"National Institute for Clinical Excellence","year":"2002","unstructured":"National Institute for Clinical Excellence: Guidance on the use of ultrasound locating devices for placing central venous catheters. Technology Appraisal Guidance. 2002, 49. [http:\/\/www.nice.org.uk"},{"key":"38_CR17","first-page":"1431","volume":"169","author":"B Funaki","year":"1997","unstructured":"Funaki B, Szymski GX, Hackworth CA, Rosenblum JD, Burke R, Chang T, Leef JA: Radiologic placement of subcutaneous Infusion chest ports for long-term central venous access. Am J Radiol. 1997, 169: 1431-1434.","journal-title":"Am J Radiol"},{"issue":"4","key":"38_CR18","doi-asserted-by":"publisher","first-page":"883","DOI":"10.1097\/00000539-200110000-00016","volume":"93","author":"DB Andropoulos","year":"2001","unstructured":"Andropoulos DB, Bent ST, Skjonsby B, Staver SA: The optimal length of insertion of central venous catheters for pediatric patients. Anesth Analg. 2001, 93 (4): 883-886. 10.1097\/00000539-200110000-00016.","journal-title":"Anesth Analg"},{"issue":"3","key":"38_CR19","doi-asserted-by":"publisher","first-page":"355","DOI":"10.1111\/j.1399-6576.2006.00951.x","volume":"50","author":"SZ Yoon","year":"2006","unstructured":"Yoon SZ, Shin TJ, Kim HS, Lee J, Kim CS, Kim SD, Park CD: Depth of a central venous catheter Tipp: length of insertion guideline for pediatric patients. Acta Anaesthesiol Scand. 2006, 50 (3): 355-357. 10.1111\/j.1399-6576.2006.00951.x.","journal-title":"Acta Anaesthesiol Scand"},{"issue":"10","key":"38_CR20","doi-asserted-by":"publisher","first-page":"692","DOI":"10.1007\/s002470000297","volume":"30","author":"B Connolly","year":"2000","unstructured":"Connolly B, Mawson JB, MacDonald CE, Chait P, Mikailian H: Fluoroscopic landmark for SVC-RA junction for central venous catheter placement in children. Pediatr Radiol. 2000, 30 (10): 692-695. 10.1007\/s002470000297.","journal-title":"Pediatr Radiol"}],"container-title":["Patient Safety in Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/1754-9493-2-30.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,9,1]],"date-time":"2021-09-01T00:40:03Z","timestamp":1630456803000},"score":1,"resource":{"primary":{"URL":"https:\/\/pssjournal.biomedcentral.com\/articles\/10.1186\/1754-9493-2-30"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2008,11,13]]},"references-count":20,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2008,12]]}},"alternative-id":["38"],"URL":"https:\/\/doi.org\/10.1186\/1754-9493-2-30","relation":{},"ISSN":["1754-9493"],"issn-type":[{"value":"1754-9493","type":"electronic"}],"subject":[],"published":{"date-parts":[[2008,11,13]]},"assertion":[{"value":"2 September 2008","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"13 November 2008","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"13 November 2008","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}}],"article-number":"30"}}