{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,11]],"date-time":"2026-03-11T04:43:24Z","timestamp":1773204204648,"version":"3.50.1"},"reference-count":21,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2019,7,5]],"date-time":"2019-07-05T00:00:00Z","timestamp":1562284800000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"},{"start":{"date-parts":[[2019,7,5]],"date-time":"2019-07-05T00:00:00Z","timestamp":1562284800000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Med Imaging"],"published-print":{"date-parts":[[2019,12]]},"DOI":"10.1186\/s12880-019-0354-0","type":"journal-article","created":{"date-parts":[[2019,7,5]],"date-time":"2019-07-05T12:02:49Z","timestamp":1562328169000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":13,"title":["Ultrasound measurements versus invasive intracranial pressure measurement method in patients with brain injury: a retrospective study"],"prefix":"10.1186","volume":"19","author":[{"given":"Jing","family":"Zhou","sequence":"first","affiliation":[]},{"given":"Jing","family":"Li","sequence":"additional","affiliation":[]},{"given":"Tiantian","family":"Ye","sequence":"additional","affiliation":[]},{"ORCID":"https:\/\/orcid.org\/0000-0001-9304-1298","authenticated-orcid":false,"given":"Yanrong","family":"Zeng","sequence":"additional","affiliation":[]}],"member":"297","published-online":{"date-parts":[[2019,7,5]]},"reference":[{"key":"354_CR1","doi-asserted-by":"publisher","first-page":"1800","DOI":"10.1007\/s00134-012-2655-4","volume":"38","author":"S Badri","year":"2012","unstructured":"Badri S, Chen J, Barber J, Temkin NR, Dikmen SS, Chesnut RM, Deem S, Yanez ND, Treggiari MM. Mortality and long-term functional outcome associated with intracranial pressure after traumatic brain injury. Intensive Care Med. 2012;38:1800\u20139.","journal-title":"Intensive Care Med"},{"key":"354_CR2","doi-asserted-by":"publisher","first-page":"2471","DOI":"10.1056\/NEJMoa1207363","volume":"367","author":"RM Chesnut","year":"2012","unstructured":"Chesnut RM, Temkin N, Carney N, Dikmen S, Rondina C, Videtta W, Petroni G, Lujan S, Pridgeon J, Barber J, Machamer J, Chaddock K, Celix JM, Cherner M, Hendrix T. A trial of intracranial-pressure monitoring in traumatic brain injury. N Engl J Med. 2012;367:2471\u201381.","journal-title":"N Engl J Med"},{"key":"354_CR3","doi-asserted-by":"publisher","first-page":"265","DOI":"10.1016\/j.jss.2011.03.009","volume":"170","author":"A Strumwasser","year":"2011","unstructured":"Strumwasser A, Kwan RO, Yeung L, Miraflor E, Ereso A, Castro-Moure F, Patel A, Sadjadi J, Victorino GP. Sonographic optic nerve sheath diameter as an estimate of intracranial pressure in adult trauma. J Surg Res. 2011;170:265\u201371.","journal-title":"J Surg Res"},{"key":"354_CR4","doi-asserted-by":"crossref","first-page":"6","DOI":"10.1227\/NEU.0000000000001432","volume":"80","author":"N Carney","year":"2017","unstructured":"Carney N, Totten AM, O'Reilly C, Ullman JS, Hawryluk GW, Bell MJ, Bratton SL, Chesnut R, Harris OA, Kissoon N, Rubiano AM, Shutter L, Tasker RC, Vavilala MS, Wilberger J, Wright DW, Ghajar J. Guidelines for the management of severe traumatic brain injury, fourth edition. Neurosurgery. 2017;80:6\u201315.","journal-title":"Neurosurgery"},{"issue":"7","key":"354_CR5","doi-asserted-by":"publisher","first-page":"e1002356","DOI":"10.1371\/journal.pmed.1002356","volume":"14","author":"Chiara Robba","year":"2017","unstructured":"Robba C, Cardim D, Tajsic T, Pietersen J, Bulman M, Donnelly J, Lavinio A, Gupta A, Menon DK, Hutchinson PJA, Czosnyka M. Ultrasound non-invasive measurement of intracranial pressure in neurointensive care: a prospective observational study. PLoS Med. 2017;14. \n                    https:\/\/doi.org\/10.1371\/journal.pmed.1002356\n                    \n                  .","journal-title":"PLOS Medicine"},{"key":"354_CR6","doi-asserted-by":"publisher","first-page":"S59","DOI":"10.1089\/neu.2007.9987","volume":"24","author":"SL Bratton","year":"2007","unstructured":"Brain Trauma Foundation, American Association of Neurological Surgeons, Congress of Neurological Surgeons, Joint Section on Neurotrauma and Critical Care, AANS\/CNS, Bratton SL, Chestnut RM, Ghajar J, McConnell Hammond FF, Harris OA, Hartl R, Manley GT, Nemecek A, Newell DW, Rosenthal G, Schouten J, Shutter L, Timmons SD, Ullman JS, Videtta W, Wilberger JE, Wright DW. Guidelines for the management of severe traumatic brain injury. IX. Cerebral perfusion thresholds. J Neurotrauma. 2007;24:S59\u201364.","journal-title":"J Neurotrauma"},{"key":"354_CR7","doi-asserted-by":"publisher","first-page":"2062","DOI":"10.1007\/s00134-008-1149-x","volume":"34","author":"T Geeraerts","year":"2008","unstructured":"Geeraerts T, Merceron S, Benhamou D, Vigu\u00e9 B, Duranteau J. Non-invasive assessment of intracranial pressure using ocular sonography in neurocritical care patients. Intensive Care Med. 2008;34:2062\u20137.","journal-title":"Intensive Care Med"},{"key":"354_CR8","doi-asserted-by":"publisher","first-page":"853","DOI":"10.1227\/NEU.0b013e3182675b42","volume":"71","author":"C Zweifel","year":"2012","unstructured":"Zweifel C, Czosnyka M, Carrera E, de Riva N, Pickard JD, Smielewski P. Reliability of the blood flow velocity pulsatility index for assessment of intracranial and cerebral perfusion pressures in head-injured patients. Neurosurgery. 2012;71:853\u201361.","journal-title":"Neurosurgery"},{"key":"354_CR9","doi-asserted-by":"publisher","first-page":"607","DOI":"10.1179\/1743132813Y.0000000308","volume":"36","author":"A Ragauskas","year":"2014","unstructured":"Ragauskas A, Bartusis L, Piper I, Zakelis R, Matijosaitis V, Petrikonis K, Rastenyte D. Improved diagnostic value of a TCD-based non-invasive ICP measurement method compared with the sonographic ONSD method for detecting elevated intracranial pressure. Neurol Res. 2014;36:607\u201314.","journal-title":"Neurol Res"},{"key":"354_CR10","doi-asserted-by":"publisher","first-page":"1684","DOI":"10.1212\/WNL.0b013e3182574f50","volume":"78","author":"A Ragauskas","year":"2012","unstructured":"Ragauskas A, Matijosaitis V, Zakelis R, Petrikonis K, Rastenyte D, Piper I, Daubaris G. Clinical assessment of noninvasive intracranial pressure absolute value measurement method. Neurology. 2012;78:1684\u201391.","journal-title":"Neurology"},{"key":"354_CR11","doi-asserted-by":"publisher","first-page":"93","DOI":"10.1159\/000346087","volume":"35","author":"T Steiner","year":"2013","unstructured":"Steiner T, Juvela S, Unterberg A, Jung C, Forsting M, Rinkel G, European Stroke Organization. European stroke organization guidelines for the management of intracranial aneurysms and subarachnoid haemorrhage. Cerebrovasc Dis. 2013;35:93\u2013112.","journal-title":"Cerebrovasc Dis"},{"key":"354_CR12","doi-asserted-by":"publisher","first-page":"632","DOI":"10.1227\/NEU.0000000000000533","volume":"75","author":"R Raj","year":"2014","unstructured":"Raj R, Siironen J, Skrifvars MB, Hernesniemi J, Kivisaari R. Predicting outcome in traumatic brain injury: development of a novel computerized tomography classification system (Helsinki computerized tomography score). Neurosurgery. 2014;75:632\u201346.","journal-title":"Neurosurgery"},{"key":"354_CR13","doi-asserted-by":"publisher","first-page":"783","DOI":"10.1093\/bja\/aew356","volume":"117","author":"C Robba","year":"2016","unstructured":"Robba C, Cardim D, Donnelly J, Bertuccio A, Bacigaluppi S, Bragazzi N, Cabella B, Liu X, Matta B, Lattuada M, Czosnyka M. Effects of pneumoperitoneum and Trendelenburg position on intracranial pressure assessed using different non-invasive method. Br J Anaesth. 2016;117:783\u201391.","journal-title":"Br J Anaesth"},{"key":"354_CR14","doi-asserted-by":"publisher","first-page":"243","DOI":"10.1097\/ANA.0000000000000295","volume":"29","author":"C Robba","year":"2017","unstructured":"Robba C, Bragazzi NL, Bertuccio A, Cardim D, Donnelly J, Sekhon M, Lavinio A, Duane D, Burnstein R, Matta B, Bacigaluppi S, Lattuada M, Czosnyka M. Effects of prone position and positive end-expiratory pressure on noninvasive estimators of ICP: a pilot study. J Neurosurg Anesthesiol. 2017;29:243\u201350.","journal-title":"J Neurosurg Anesthesiol"},{"key":"354_CR15","doi-asserted-by":"publisher","first-page":"1579","DOI":"10.7863\/ultra.16.05055","volume":"36","author":"S Oberfoell","year":"2017","unstructured":"Oberfoell S, Murphy D, French A, Trent S, Richards D. Inter-rater reliability of sonographic optic nerve sheath diameter measurements by emergency medicine physicians. J Ultrasound Med. 2017;36:1579\u201384.","journal-title":"J Ultrasound Med"},{"key":"354_CR16","doi-asserted-by":"publisher","first-page":"104","DOI":"10.1007\/s12028-007-0012-1","volume":"6","author":"MM Treggiari","year":"2007","unstructured":"Treggiari MM, Schutz N, Yanez ND, Romand JA. Role of intracranial pressure values and patterns in predicting outcome in traumatic brain injury: a systematic review. Neurocrit Care. 2007;6:104\u201312.","journal-title":"Neurocrit Care"},{"key":"354_CR17","doi-asserted-by":"publisher","first-page":"1050","DOI":"10.1227\/01.NEU.0000369519.35932.F2","volume":"66","author":"A Behrens","year":"2010","unstructured":"Behrens A, Lenfeldt N, Ambarki K, Malm J, Eklund A, Koskinen LO. Transcranial Doppler pulsatility index: not an accurate method to assess intracranial pressure. Neurosurgery. 2010;66:1050\u20137.","journal-title":"Neurosurgery"},{"key":"354_CR18","doi-asserted-by":"publisher","first-page":"963","DOI":"10.1016\/j.ajem.2016.02.012","volume":"34","author":"E Komut","year":"2016","unstructured":"Komut E, Kozac\u0131 N, Sonmez BM, Y\u0131lmaz F, Komut S, Y\u0131ld\u0131r\u0131m ZN, Beydilli I, Yel C. Bedside sonographic measurement of optic nerve sheath diameter as a predictor of intracranial pressure in ED. Am J Emerg Med. 2016;34:963\u20137.","journal-title":"Am J Emerg Med"},{"key":"354_CR19","doi-asserted-by":"publisher","first-page":"302","DOI":"10.1111\/j.1552-6569.2012.00745.x","volume":"24","author":"B Wakerley","year":"2014","unstructured":"Wakerley B, Yohana K, Luen Teoh H, Tan CW, Chan BP, Sharma VK. Non-invasive intracranial pressure monitoring with transcranial Doppler in a patient with progressive cerebral venous sinus thrombosis. J Neuroimaging. 2014;24:302\u20134.","journal-title":"J Neuroimaging"},{"key":"354_CR20","doi-asserted-by":"publisher","first-page":"1051","DOI":"10.1007\/s00134-011-2226-0","volume":"37","author":"AR Frattalone","year":"2011","unstructured":"Frattalone AR, Stevens RD. Intracranial pressure and its surrogates. Intensive Care Med. 2011;37:1051\u20133.","journal-title":"Intensive Care Med"},{"key":"354_CR21","doi-asserted-by":"publisher","first-page":"1059","DOI":"10.1007\/s00134-011-2224-2","volume":"37","author":"J Dubourg","year":"2011","unstructured":"Dubourg J, Javouhey E, Geeraerts T, Messerer M, Kassai B. Ultrasonography of optic nerve sheath diameter for detection of raised intracranial pressure: a systematic review and meta-analysis. Intensive Care Med. 2011;37:1059\u201368.","journal-title":"Intensive Care Med"}],"container-title":["BMC Medical Imaging"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1186\/s12880-019-0354-0.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1186\/s12880-019-0354-0\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1186\/s12880-019-0354-0.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2020,7,3]],"date-time":"2020-07-03T23:14:38Z","timestamp":1593818078000},"score":1,"resource":{"primary":{"URL":"https:\/\/bmcmedimaging.biomedcentral.com\/articles\/10.1186\/s12880-019-0354-0"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,7,5]]},"references-count":21,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2019,12]]}},"alternative-id":["354"],"URL":"https:\/\/doi.org\/10.1186\/s12880-019-0354-0","relation":{},"ISSN":["1471-2342"],"issn-type":[{"value":"1471-2342","type":"electronic"}],"subject":[],"published":{"date-parts":[[2019,7,5]]},"assertion":[{"value":"1 May 2019","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"24 June 2019","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"5 July 2019","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The protocol of the study (BLH\/CMU\/CL\/25\/17 dated 2 February 2017) had been approved by the Beijing Luhe Hospital human ethics committee. An informed consent form had been signed by all participating patients or patient caretakers regarding imaging modalities, clinical examination, invasive intracranial pressure measurement, and anesthesia. The study had adhered to the law of China, the strengthening the reporting of observational studies in epidemiology (STROBE) statement, and Declaration of Helsinki (V2008).","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"An informed consent form had been signed by all participating patients or patient caretakers regarding the publication of the study in all formats of publication house including personal data of patients irrespective of time and language.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declared that they have no competing interest or any the other competing interest regarding results and\/or discussion reported in the research.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"53"}}