{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,23]],"date-time":"2026-02-23T17:27:34Z","timestamp":1771867654899,"version":"3.50.1"},"reference-count":37,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2019,7,26]],"date-time":"2019-07-26T00:00:00Z","timestamp":1564099200000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"},{"start":{"date-parts":[[2019,7,26]],"date-time":"2019-07-26T00:00:00Z","timestamp":1564099200000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"name":"Mauri and Sirkka Wiljasalo fund"},{"DOI":"10.13039\/501100008490","name":"Suomen Radiologiyhdistys","doi-asserted-by":"publisher","id":[{"id":"10.13039\/501100008490","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100004092","name":"Kuopion Yliopistollinen Sairaala","doi-asserted-by":"publisher","award":["VTR 5063530"],"award-info":[{"award-number":["VTR 5063530"]}],"id":[{"id":"10.13039\/501100004092","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100005877","name":"Luonnontieteiden ja Tekniikan Tutkimuksen Toimikunta","doi-asserted-by":"publisher","award":["285909"],"award-info":[{"award-number":["285909"]}],"id":[{"id":"10.13039\/501100005877","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100005633","name":"Syd\u00e4ntutkimuss\u00e4\u00e4ti\u00f6","doi-asserted-by":"publisher","id":[{"id":"10.13039\/501100005633","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100011797","name":"Turku University Hospital","doi-asserted-by":"crossref","id":[{"id":"10.13039\/501100011797","id-type":"DOI","asserted-by":"crossref"}]},{"DOI":"10.13039\/501100005878","name":"Terveyden Tutkimuksen Toimikunta","doi-asserted-by":"publisher","award":["271961"],"award-info":[{"award-number":["271961"]}],"id":[{"id":"10.13039\/501100005878","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Med Imaging"],"published-print":{"date-parts":[[2019,12]]},"DOI":"10.1186\/s12880-019-0359-8","type":"journal-article","created":{"date-parts":[[2019,7,26]],"date-time":"2019-07-26T13:02:27Z","timestamp":1564146147000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":7,"title":["Quantification of porcine myocardial perfusion with modified dual bolus MRI \u2013 a prospective study with a PET reference"],"prefix":"10.1186","volume":"19","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-8045-981X","authenticated-orcid":false,"given":"Minna","family":"Husso","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Mikko J.","family":"Nissi","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Antti","family":"Kuivanen","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Paavo","family":"Halonen","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Miikka","family":"Tarkia","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jarmo","family":"Teuho","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Virva","family":"Saunavaara","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Pauli","family":"Vainio","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Petri","family":"Sipola","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hannu","family":"Manninen","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Seppo","family":"Yl\u00e4-Herttuala","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Juhani","family":"Knuuti","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Juha","family":"T\u00f6yr\u00e4s","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2019,7,26]]},"reference":[{"issue":"2","key":"359_CR1","doi-asserted-by":"publisher","first-page":"201","DOI":"10.1016\/j.mric.2008.03.002","volume":"16","author":"GP Reddy","year":"2008","unstructured":"Reddy GP, Pujadas S, Ordovas KG, Higgins CB. MR imaging of ischemic heart disease. Magn Reson Imaging Clin N Am. 2008;16(2):201\u201312.","journal-title":"Magn Reson Imaging Clin N Am"},{"issue":"1","key":"359_CR2","doi-asserted-by":"publisher","first-page":"82","DOI":"10.1002\/jmri.1880070112","volume":"7","author":"TP Roberts","year":"1997","unstructured":"Roberts TP. Physiologic measurements by contrast-enhanced MR imaging: expectations and limitations. J Magn Reson Imaging. 1997;7(1):82\u201390.","journal-title":"J Magn Reson Imaging"},{"issue":"4","key":"359_CR3","doi-asserted-by":"publisher","first-page":"818","DOI":"10.1002\/jmri.21306","volume":"27","author":"T Fritz-Hansen","year":"2008","unstructured":"Fritz-Hansen T, Hove JD, Kofoed KF, Kelbaek H, Larsson HB. Quantification of MRI measured myocardial perfusion reserve in healthy humans: a comparison with positron emission tomography. J Magn Reson Imaging. 2008;27(4):818\u201324.","journal-title":"J Magn Reson Imaging"},{"key":"359_CR4","doi-asserted-by":"publisher","first-page":"11","DOI":"10.1186\/1532-429X-16-11","volume":"16","author":"C Miller","year":"2014","unstructured":"Miller C, Naish J, Ainslie M, Tonge C, Tout D, Arumugam P, Banerji A, Egdell R, Clark D, Weale P, Steadman C, McCann G, Ray S, Parker G, Schmitt M. Voxel-wise quantification of myocardial blood flow with cardiovascular magnetic resonance: effect of variations in methodology and validation with positron emission tomography. J Cardiovasc Magn Reson. 2014;16:11.","journal-title":"J Cardiovasc Magn Reson"},{"key":"359_CR5","doi-asserted-by":"publisher","first-page":"902","DOI":"10.1002\/nbm.1648","volume":"24","author":"N Just","year":"2011","unstructured":"Just N, Koh D, D'Arcy J, Collins D, Leach M. Assessment of the effec tof haematocrit-dependent arterial inputf unctions on the accuracy of pharmacokinetic parameters in dynamic contrast-enhanced MRI. NMR Biomed. 2011;24:902\u201315.","journal-title":"NMR Biomed"},{"issue":"5","key":"359_CR6","doi-asserted-by":"publisher","first-page":"886","DOI":"10.1118\/1.1473135","volume":"29","author":"M Jerosch-Herold","year":"2002","unstructured":"Jerosch-Herold M, Swingen C, Seethamraju RT. Myocardial blood flow quantification with MRI by model-independent deconvolution. Med Phys. 2002;29(5):886\u201397.","journal-title":"Med Phys"},{"issue":"9","key":"359_CR7","doi-asserted-by":"publisher","first-page":"1103","DOI":"10.1016\/j.jcmg.2009.06.009","volume":"2","author":"T Christian","year":"2009","unstructured":"Christian T, Bell S, Whitesell L, Jerosch-Herold M. Accuracy of cardiac magnetic resonance of absolute myocardial blood flow with a high-field system: comparison with conventional field strength. JACC Cardiovasc Imaging. 2009;2(9):1103\u201310.","journal-title":"JACC Cardiovasc Imaging"},{"issue":"2","key":"359_CR8","doi-asserted-by":"publisher","first-page":"373","DOI":"10.1148\/radiology.204.2.9240523","volume":"204","author":"N Wilke","year":"1997","unstructured":"Wilke N, Jerosch-Herold M, Wang Y, Huang Y, Christensen B, Stillman A, Ugurbil K, McDonald K, Wilson R. Myocardial perfusion reserve: assessment with multisection, quantitative, first-pass MR imaging. Radiology. 1997;204(2):373\u201384.","journal-title":"Radiology"},{"issue":"6","key":"359_CR9","doi-asserted-by":"publisher","first-page":"1271","DOI":"10.1002\/jmri.21383","volume":"27","author":"TF Christian","year":"2008","unstructured":"Christian TF, Aletras A, Arai A. Estimation of absolute myocardial blood flow during first-pass MR perfusion imaging using a dual-bolus injection technique: comparison to single-bolus injection method. J Magn Reson Imaging. 2008;27(6):1271\u20137.","journal-title":"J Magn Reson Imaging"},{"issue":"1","key":"359_CR10","doi-asserted-by":"publisher","first-page":"39","DOI":"10.1002\/jmri.20054","volume":"20","author":"PD Gatehouse","year":"2004","unstructured":"Gatehouse PD, Elkington AG, Ablitt NA, Yang G, Pennell DJ, Firmin DN. Accurate assessment of the arterial input function during high-dose myocardial perfusion cardiovascular magnetic resonance. J Magn Reson Imaging. 2004;20(1):39\u201345.","journal-title":"J Magn Reson Imaging"},{"issue":"17","key":"359_CR11","doi-asserted-by":"publisher","first-page":"21","DOI":"10.1186\/s12968-015-0116-2","volume":"19","author":"J S\u00e1nchez-Gonz\u00e1lez","year":"2015","unstructured":"S\u00e1nchez-Gonz\u00e1lez J, Fernandez-Jim\u00e9nez R, Nothnagel ND, L\u00f3pez-Mart\u00edn G, Fuster V, Iba\u00f1ez B. Optimization of dual-saturation single bolus acquisition for quantitative cardiac perfusion and myocardial blood flow maps. J Cardiovasc Magn Reson. 2015;19(17):21.","journal-title":"J Cardiovasc Magn Reson"},{"issue":"2","key":"359_CR12","doi-asserted-by":"publisher","first-page":"296","DOI":"10.1002\/mrm.20160","volume":"52","author":"H K\u00f6stler","year":"2004","unstructured":"K\u00f6stler H, Ritter C, Lipp M, Beer M, Hahn D, Sandstede J. Prebolus quantitative MR heart perfusion imaging. Magn Reson Med. 2004;52(2):296\u20139.","journal-title":"Magn Reson Med"},{"issue":"3","key":"359_CR13","doi-asserted-by":"publisher","first-page":"677","DOI":"10.1148\/radiol.2323030573","volume":"232","author":"TF Christian","year":"2004","unstructured":"Christian TF, Rettmann DW, Aletras AH, Liao SL, Taylor JL, Balaban RS, Arai AE. Absolute myocardial perfusion in canines measured by using dual-bolus first-pass MR imaging. Radiology. 2004;232(3):677\u201384.","journal-title":"Radiology"},{"issue":"4","key":"359_CR14","doi-asserted-by":"publisher","first-page":"533","DOI":"10.1088\/0967-3334\/35\/4\/533","volume":"35","author":"M Husso","year":"2014","unstructured":"Husso M, Sipola P, Kuittinen T, Manninen H, Vainio P, Hartikainen J, Saarakkala S, T\u00f6yr\u00e4s J, Kuikka J. Assessment of myocardial perfusion with MRI using a modified dual bolus method. Physiol Meas. 2014;35(4):533\u201347.","journal-title":"Physiol Meas"},{"issue":"1","key":"359_CR15","first-page":"75","volume":"46","author":"PA Kaufmann","year":"2005","unstructured":"Kaufmann PA, Camici PG. Myocardial blood flow measurement by PET: technical aspects and clinical applications. J Nucl Med. 2005;46(1):75\u201388.","journal-title":"J Nucl Med"},{"issue":"9","key":"359_CR16","doi-asserted-by":"publisher","first-page":"H1297","DOI":"10.1152\/ajpheart.00561.2013","volume":"305","author":"TT Rissanen","year":"2013","unstructured":"Rissanen TT, Nurro J, Halonen PJ, Tarkia M, Saraste A, Rannankari M, Honkonen K, Pietil\u00e4 M, Lepp\u00e4nen O, Kuivanen A, Knuuti J, Yl\u00e4-Herttuala S. The bottleneck stent model for chronic myocardial ischemia and heart failure in pigs. Am J Physiol Heart Circ Physiol. 2013;305(9):H1297\u2013308.","journal-title":"Am J Physiol Heart Circ Physiol"},{"issue":"10","key":"359_CR17","doi-asserted-by":"publisher","first-page":"3091","DOI":"10.1088\/0031-9155\/56\/10\/013","volume":"56","author":"H Zaidi","year":"2011","unstructured":"Zaidi H, Ojha N, Morich M, Griesmer J, Hu Z, Maniawski P, Ratib O, Izquierdo-Garcia D, Fayad Z, Shao L. Design and performance evaluation of a whole-body ingenuity TF PET\u2013MRI system. Phys Med Biol. 2011;56(10):3091\u2013106.","journal-title":"Phys Med Biol"},{"issue":"4","key":"359_CR18","doi-asserted-by":"publisher","first-page":"331","DOI":"10.1093\/ehjci\/jes150","volume":"14","author":"A Rossi","year":"2013","unstructured":"Rossi A, Uitterdijk A, Dijkshoorn M, Klotz E, Dharampal A, van Straten M, van der Giessen W, Mollet N, van Geuns R, Krestin G, Duncker D, de Feyter D, Merkus D. Quantification of myocardial blood flow by adenosine-stress CT perfusion imaging in pigs during various degrees of stenosis correlates well with coronary artery blood flow and fractional flow reserve. Eur Heart J Cardiovasc Imaging. 2013;14(4):331\u20138.","journal-title":"Eur Heart J Cardiovasc Imaging"},{"issue":"6","key":"359_CR19","doi-asserted-by":"publisher","first-page":"1131","DOI":"10.1002\/jmri.20910","volume":"25","author":"W Utz","year":"2007","unstructured":"Utz W, Niendorf T, Wassmuth R, Messroghli D, Dietz R, Schulz-Menger J. Contrast-dose relation in first-pass myocardial MR perfusion imaging. J Magn Reson Imaging. 2007;25(6):1131\u20135.","journal-title":"J Magn Reson Imaging"},{"issue":"10","key":"359_CR20","doi-asserted-by":"publisher","first-page":"1594","DOI":"10.1007\/s00259-009-1143-8","volume":"36","author":"SV Nesterov","year":"2009","unstructured":"Nesterov SV, Han C, M\u00e4ki M, Kajander S, Naum AG, Helenius H, Lisinen I, Ukkonen H, Pietil\u00e4 M, Joutsiniemi E, Knuuti J. Myocardial perfusion quantitation with 15O-labelled water PET: high reproducibility of the new cardiac analysis software (Carimas). Eur J Nucl Med Mol Imaging. 2009;36(10):1594\u2013602.","journal-title":"Eur J Nucl Med Mol Imaging"},{"issue":"9","key":"359_CR21","first-page":"1669","volume":"33","author":"H Iida","year":"1992","unstructured":"Iida H, Rhodes CG, de Silva R, Araujo LI, Bloomfield PM, Lammertsma AA, Jones T. Use of the left ventricular time-activity curve as a noninvasive input function in dynamic oxygen-15-water positron emission tomography. J Nucl Med. 1992;33(9):1669\u201377.","journal-title":"J Nucl Med"},{"issue":"5","key":"359_CR22","doi-asserted-by":"publisher","first-page":"1295","DOI":"10.1002\/mrm.20666","volume":"54","author":"EVR DiBella","year":"2005","unstructured":"DiBella EVR, Parker DL, Sinusas AJ. On the dark rim artifact in dynamic contrast-enhanced MRI myocardial perfusion studies. Magn Reson Med. 2005;54(5):1295\u20139.","journal-title":"Magn Reson Med"},{"key":"359_CR23","doi-asserted-by":"publisher","first-page":"309","DOI":"10.1161\/01.RES.16.4.309","volume":"16","author":"KL Zierler","year":"1965","unstructured":"Zierler KL. Equations for measuring blood flow by external monitoring of radioisotopes. Circ Res. 1965;16:309\u201321.","journal-title":"Circ Res"},{"issue":"5","key":"359_CR24","doi-asserted-by":"publisher","first-page":"879","DOI":"10.1152\/jappl.1967.22.5.879","volume":"22","author":"JB Bassingthwaighte","year":"1967","unstructured":"Bassingthwaighte JB, Ackerman FH. Mathematical linearity of circulatory transport. J Appl Physiol. 1967;22(5):879\u201388.","journal-title":"J Appl Physiol"},{"key":"359_CR25","doi-asserted-by":"publisher","DOI":"10.1887\/0750304359","volume-title":"Introduction to inverse problems in imaging","author":"M Bertero","year":"1998","unstructured":"Bertero M. Introduction to inverse problems in imaging. London: Institute of Physics publishing; 1998."},{"issue":"5","key":"359_CR26","doi-asserted-by":"publisher","first-page":"1132","DOI":"10.1002\/mrm.21061","volume":"56","author":"P Kellman","year":"2006","unstructured":"Kellman P, Aletras AH, Hsu LY, McVeigh ER, Arai AE. T2* measurement during first-pass contrast-enhanced cardiac perfusion imaging. Magn Reson Med. 2006;56(5):1132\u20134.","journal-title":"Magn Reson Med"},{"issue":"5","key":"359_CR27","doi-asserted-by":"publisher","first-page":"1391","DOI":"10.1002\/mrm.22936","volume":"66","author":"M Ishida","year":"2011","unstructured":"Ishida M, Ichihara T, Nagata M, Ishida N, Takase S, Kurita T, Ito M, Takeda K, Sakuma H. Quantification of myocardial blood flow using model based analysis of first-pass perfusion MRI: extraction fraction of Gd-DTPA varies with myocardial blood flow in human myocardium. Magn Reson Med. 2011;66(5):1391\u20139.","journal-title":"Magn Reson Med"},{"issue":"4","key":"359_CR28","first-page":"1","volume":"17","author":"M Motwani","year":"2015","unstructured":"Motwani M, Kidambi A, Uddin A, Sourbron S, Greenwood J, Plein S. Quantification of myocardial blood flow with cardiovascular magnetic resonance throughout the cardiac cycle. J. Cardiovasc. Magn. Reson. 2015;17(4):1\u20139.","journal-title":"J. Cardiovasc. Magn. Reson."},{"key":"359_CR29","doi-asserted-by":"publisher","first-page":"82","DOI":"10.1186\/s12968-014-0082-0","volume":"16","author":"A Schuster","year":"2014","unstructured":"Schuster A. Quantitative assessment of magnetic resonance derived myocardial perfusion measurements using advanced techniques: microsphere validation in an explanted pig heart system. J Cardiovasc Magn Reson. 2014;16:82.","journal-title":"J Cardiovasc Magn Reson"},{"issue":"16","key":"359_CR30","doi-asserted-by":"publisher","first-page":"1546","DOI":"10.1016\/j.jacc.2012.05.052","volume":"60","author":"G Morton","year":"2012","unstructured":"Morton G, Chiribiri A, Ishida M, Hussain ST, Schuster A, Indermuehle A, Perera D, Knuuti J, Baker S, Hedstrom E, Schleyer P, O'Doherty M, Barrington S, Nagel E. Quantification of absolute myocardial perfusion in patients with coronary artery disease: comparison between cardiovascular magnetic resonance and positron emission tomography. J. Am. Coll. Cardiol. 2012;60(16):1546\u201355.","journal-title":"J. Am. Coll. Cardiol"},{"issue":"3","key":"359_CR31","doi-asserted-by":"publisher","first-page":"243","DOI":"10.1258\/la.2008.0080026","volume":"43","author":"G Sch\u00f6ffmann","year":"2009","unstructured":"Sch\u00f6ffmann G, Winter P, Palme R, Pollak A, Trittenwein G, Golej J. Haemodynamic changes and stress responses of piglets to surgery during total intravenous anaesthesia with propofol and fentanyl. Lab Anim. 2009;43(3):243\u20138.","journal-title":"Lab Anim"},{"issue":"3","key":"359_CR32","doi-asserted-by":"publisher","first-page":"565","DOI":"10.1081\/JCMR-200060647","volume":"7","author":"R Gebker","year":"2005","unstructured":"Gebker R, Paetsch I, Neuss M, Schnackenburg B, Bornstedt A, Jahnke C, Gomaa O, Fleck E, Nagel E. Determinants of myocardial response in CMR perfusion imaging using Gd-BOPTA (Multihance). J Cardiovasc Magn Reson. 2005;7(3):565\u201372.","journal-title":"J Cardiovasc Magn Reson"},{"issue":"3","key":"359_CR33","doi-asserted-by":"publisher","first-page":"319","DOI":"10.1161\/01.RES.6.3.319","volume":"6","author":"E Braunwald","year":"1958","unstructured":"Braunwald E, Sarnoff SJ, Stainsby WN. Determinants of duration and mean rate of ventricular ejection. Circ Res. 1958;6(3):319\u201325.","journal-title":"Circ Res"},{"issue":"4","key":"359_CR34","doi-asserted-by":"publisher","first-page":"174","DOI":"10.1186\/cc6975","volume":"12","author":"J Vincent","year":"2008","unstructured":"Vincent J. Understanding cardiac output. Crit Care. 2008;12(4):174.","journal-title":"Crit Care"},{"key":"359_CR35","doi-asserted-by":"publisher","first-page":"367","DOI":"10.1016\/0002-8703(61)90403-3","volume":"62","author":"AM Weissler","year":"1961","unstructured":"Weissler AM, Peeler RG, Roehll WHJ. Relationships between left ventricular ejection time, stroke volume, and heart rate in normal individuals and patients with cardiovascular disease. Am Heart J. 1961;62:367\u201378.","journal-title":"Am Heart J"},{"issue":"5","key":"359_CR36","doi-asserted-by":"publisher","first-page":"449","DOI":"10.1097\/00000658-197805000-00002","volume":"187","author":"SK Rerych","year":"1978","unstructured":"Rerych SK, Scholz PM, Newman GE, Sabiston DC, Jones RH. Cardiac function at rest and during exercise in normals and in patients with coronary heart disease: evaluation by radionuclide angiocardiography. Ann Surg. 1978;187(5):449\u201364.","journal-title":"Ann Surg"},{"issue":"2","key":"359_CR37","doi-asserted-by":"publisher","first-page":"203","DOI":"10.1161\/01.CIR.69.2.203","volume":"69","author":"RJ Rodeheffer","year":"1984","unstructured":"Rodeheffer RJ, Gerstenblith G, Becker LC, Fleg JL, Weisfeldt ML, Lakatta EG. Exercise cardiac output is maintained with advancing age in healthy human subjects: cardiac dilatation and increased stroke volume compensate for a diminished heart rate. Circulation. 1984;69(2):203\u201313.","journal-title":"Circulation"}],"container-title":["BMC Medical Imaging"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1186\/s12880-019-0359-8.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1186\/s12880-019-0359-8\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1186\/s12880-019-0359-8.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2020,7,24]],"date-time":"2020-07-24T23:11:42Z","timestamp":1595632302000},"score":1,"resource":{"primary":{"URL":"https:\/\/bmcmedimaging.biomedcentral.com\/articles\/10.1186\/s12880-019-0359-8"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,7,26]]},"references-count":37,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2019,12]]}},"alternative-id":["359"],"URL":"https:\/\/doi.org\/10.1186\/s12880-019-0359-8","relation":{},"ISSN":["1471-2342"],"issn-type":[{"value":"1471-2342","type":"electronic"}],"subject":[],"published":{"date-parts":[[2019,7,26]]},"assertion":[{"value":"21 December 2017","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"17 July 2019","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"26 July 2019","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"All animal experiments were approved by the National Animal Experiment Board (licence no. ESAVI-2012-001932), and conform to the Directive 2010\/63\/EU of the European Parliament.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Not applicable.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare that they have no competing interests.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"58"}}