{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,7]],"date-time":"2026-07-07T14:24:27Z","timestamp":1783434267905,"version":"3.54.6"},"reference-count":35,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2020,4,19]],"date-time":"2020-04-19T00:00:00Z","timestamp":1587254400000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"},{"start":{"date-parts":[[2020,4,19]],"date-time":"2020-04-19T00:00:00Z","timestamp":1587254400000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Med Imaging"],"published-print":{"date-parts":[[2020,12]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Background<\/jats:title>\n                    <jats:p>Based on its high resolution in soft tissue, MRI, especially diffusion-weighted imaging (DWI), is increasingly important in the evaluation of cholesteatoma. The purpose of this study was to evaluate the role of the 2D turbo gradient- and spin-echo (TGSE) diffusion-weighted (DW) pulse sequence with the BLADE trajectory technique in the diagnosis of cholesteatoma at 3\u2009T and to qualitatively and quantitatively compare image quality between the TGSE BLADE and RESOLVE methods.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Method<\/jats:title>\n                    <jats:p>A total of 42 patients (23 males, 19 females; age range, 7\u201365\u2009years; mean, 40.1\u2009years) with surgically confirmed cholesteatoma in the middle ear were enrolled in this study. All patients underwent DWI (both a prototype TGSE BLADE DWI sequence and the RESOLVE DWI sequence) using a 3-T scanner with a 64-channel brain coil.<\/jats:p>\n                    <jats:p>Qualitative imaging parameters (imaging sharpness, geometric distortion, ghosting artifacts, and overall imaging quality) and quantitative imaging parameters (apparent diffusion coefficient [ADC], signal-to-noise ratio [SNR], contrast, and contrast-to-noise ratio [CNR]) were assessed for the two diffusion acquisition techniques by two independent radiologists.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Result<\/jats:title>\n                    <jats:p>\n                      A comparison of qualitative scores indicated that TGSE BLADE DWI produced less geometric distortion, fewer ghosting artifacts (\n                      <jats:italic>P<\/jats:italic>\n                      \u2009&lt;\u20090.001) and higher image quality (\n                      <jats:italic>P<\/jats:italic>\n                      \u00a0&lt;\u20090.001) than were observed for RESOLVE DWI. A comparison of the evaluated quantitative image parameters between TGSE and RESOLVE showed that TGSE BLADE DWI produced a significantly lower SNR (\n                      <jats:italic>P<\/jats:italic>\n                      \u00a0&lt;\u20090.001) and higher parameter values (both contrast and CNR (\n                      <jats:italic>P<\/jats:italic>\n                      \u00a0&lt;\u20090.001)) than were found for RESOLVE DWI.\n                    <\/jats:p>\n                    <jats:p>\n                      The ADC (\n                      <jats:italic>P<\/jats:italic>\n                      \u00a0&lt;\u20090.001) was significantly lower for TGSE BLADE DWI (0.763\u2009\u00d7\u200910\n                      <jats:sup>\u2212\u20093<\/jats:sup>\n                      \u2009mm\n                      <jats:sup>2<\/jats:sup>\n                      \/s) than RESOLVE DWI (0.928\u2009\u00d7\u200910\n                      <jats:sup>\u2212\u20093<\/jats:sup>\n                      \u2009mm\n                      <jats:sup>2<\/jats:sup>\n                      \/s).\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion<\/jats:title>\n                    <jats:p>Compared with RESOLVE DWI, TGSE BLADE DWI significantly improved the image quality of cholesteatoma by reducing magnetic sensitive artifacts, distortion, and blurring. TGSE BLADE DWI is more valuable than RESOLVE DWI for the diagnosis of small-sized (2\u2009mm) cholesteatoma lesions. However, TGSE BLADE DWI also has some disadvantages: the whole image intensity is slightly low, so that the anatomical details of the air-bone interface are not shown well, and this shortcoming should be improved in the future.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1186\/s12880-020-00438-7","type":"journal-article","created":{"date-parts":[[2020,4,19]],"date-time":"2020-04-19T10:02:33Z","timestamp":1587290553000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":29,"title":["Performance of TGSE BLADE DWI compared with RESOLVE DWI in the diagnosis of cholesteatoma"],"prefix":"10.1186","volume":"20","author":[{"given":"Yaru","family":"Sheng","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Rujian","family":"Hong","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yan","family":"Sha","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Zhongshuai","family":"Zhang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kun","family":"Zhou","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Caixia","family":"Fu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2020,4,19]]},"reference":[{"issue":"6","key":"438_CR1","doi-asserted-by":"publisher","first-page":"587","DOI":"10.1017\/S0022215109992763","volume":"124","author":"L Louw","year":"2010","unstructured":"Louw L. Acquired cholesteatoma pathogenesis: stepwise explanations. J Laryngol Otol. 2010;124(6):587\u201393.","journal-title":"J Laryngol Otol"},{"key":"438_CR2","doi-asserted-by":"publisher","first-page":"1172","DOI":"10.2214\/AJR.10.5414","volume":"196","author":"Y Koji","year":"2011","unstructured":"Koji Y, Takashi Y, Akio H, et al. Contributing factors in the pathogenesis of acquired cholesteatoma: size analysis based on MDCT. AJR Am J Roentgenol. 2011;196:1172\u20135.","journal-title":"AJR Am J Roentgenol"},{"key":"438_CR3","doi-asserted-by":"publisher","first-page":"328","DOI":"10.12659\/PJR.894155","volume":"80","author":"RAAK Abdel","year":"2015","unstructured":"Abdel RAAK, Rashad GM, Bassem A. Computed tomography staging of middle ear cholesteatoma. Pol J Radiol. 2015;80:328\u201333.","journal-title":"Pol J Radiol"},{"issue":"898","key":"438_CR4","doi-asserted-by":"publisher","first-page":"847","DOI":"10.1259\/bjr.75.898.750847","volume":"75","author":"PD Yates","year":"2002","unstructured":"Yates PD, Flood LM, Banerjee A, Clifford K. CT scanning of middle ear cholesteatoma: what does the surgeon want to know? Br J Radiol. 2002;75(898):847\u201352.","journal-title":"Br J Radiol"},{"key":"438_CR5","doi-asserted-by":"publisher","first-page":"866","DOI":"10.1148\/radiol.10091140","volume":"255","author":"DF Bert","year":"2010","unstructured":"Bert DF, Jean-Philippe V, Anja B, et al. Middle ear cholesteatoma: non-echo-planar diffusion-weighted MR imaging versus delayed gadolinium-enhanced T1-weighted MR imaging--value in detection. Radiology. 2010;255:866\u201372.","journal-title":"Radiology"},{"key":"438_CR6","doi-asserted-by":"publisher","first-page":"388","DOI":"10.1016\/j.neurad.2017.05.006","volume":"44","author":"O Algin","year":"2017","unstructured":"Algin O, Ayd\u0131n H, Ozmen E, et al. Detection of cholesteatoma: high-resolution DWI using RS-EPI and parallel imaging at 3 tesla. J Neuroradiol. 2017;44:388\u201394.","journal-title":"J Neuroradiol"},{"key":"438_CR7","doi-asserted-by":"publisher","first-page":"217","DOI":"10.4329\/wjr.v9.i5.217","volume":"9","author":"H Benjamin","year":"2017","unstructured":"Benjamin H, Christian K. Diffusion weighted imaging for the detection and evaluation of cholesteatoma. World J Radiol. 2017;9:217\u201322.","journal-title":"World J Radiol"},{"issue":"7","key":"438_CR8","doi-asserted-by":"publisher","first-page":"1461","DOI":"10.1007\/s00330-006-0160-2","volume":"16","author":"JP Vercruysse","year":"2006","unstructured":"Vercruysse JP, De Foer B, Pouillon M, Somers T, Casselman J, Offeciers E. The value of diffusion-weighted MR imaging in the diagnosis of primary acquired and residual cholesteatoma: a surgical verified study of 100 patients. Eur Radiol. 2006;16(7):1461\u20137.","journal-title":"Eur Radiol"},{"issue":"7","key":"438_CR9","first-page":"1480","volume":"27","author":"B De Foer","year":"2006","unstructured":"De Foer B, Vercruysse JP, Pilet B, et al. Single-shot, turbo spin-echo, diffusion-weighted imaging versus spin-echo-planar, diffusion-weighted imaging in the detection of acquired middle ear cholesteatoma. AJNR. Am J Neuroradiol. 2006;27(7):1480\u20132.","journal-title":"Am J Neuroradiol"},{"key":"438_CR10","doi-asserted-by":"publisher","first-page":"669","DOI":"10.1007\/s13244-016-0516-3","volume":"\\","author":"K Lingam Ravi","year":"2016","unstructured":"Lingam Ravi K, Nash Robert, Majithia Anooj et al. Non-echoplanar diffusion weighted imaging in the detection of post-operative middle ear cholesteatoma: navigating beyond the pitfalls to find the pearl. Insights Imaging. 2016:669\u2013678.","journal-title":"Insights Imaging"},{"key":"438_CR11","doi-asserted-by":"publisher","first-page":"597896","DOI":"10.1155\/2015\/597896","volume":"2015","author":"A Elefante","year":"2015","unstructured":"Elefante A, Cavaliere M, Russo C, et al. Diffusion weighted MR imaging of primary and recurrent middle ear cholesteatoma: an assessment by readers with different expertise. Biomed Res Int. 2015;2015:597896.","journal-title":"Biomed Res Int"},{"key":"438_CR12","doi-asserted-by":"publisher","first-page":"430","DOI":"10.3174\/ajnr.A2129","volume":"32","author":"KM Schwartz","year":"2011","unstructured":"Schwartz KM, Lane JI, Bolster BD, et al. The utility of diffusion-weighted imaging for cholesteatoma evaluation. AJNR Am J Neuroradiol. 2011;32:430\u20136.","journal-title":"AJNR Am J Neuroradiol"},{"issue":"1","key":"438_CR13","doi-asserted-by":"publisher","first-page":"64","DOI":"10.1148\/radiol.12111494","volume":"263","author":"W Bogner","year":"2012","unstructured":"Bogner W, Pinker-Domenig K, Bickel H, et al. Readout-segmented echo-planar imaging improves the diagnostic performance of diffusion-weighted MR breast examinations at 3.0 T. Radiology. 2012;263(1):64\u201376.","journal-title":"Radiology."},{"issue":"12)","key":"438_CR14","doi-asserted-by":"publisher","first-page":"1457","DOI":"10.1177\/0284185117695667","volume":"58","author":"X Xu","year":"2017","unstructured":"Xu X, Wang Y, Hu H, Su G, Liu H. Readout-segmented echo-planar diffusion-weighted imaging in the assessment of orbital tumors: comparison with conventional single-shot echo-planar imaging in image quality and diagnostic performance. Acta Radiol. 2017;58(12)):1457\u201367.","journal-title":"Acta Radiol"},{"key":"438_CR15","doi-asserted-by":"publisher","first-page":"166","DOI":"10.1016\/j.mri.2015.10.010","volume":"34","author":"M Zhao","year":"2016","unstructured":"Zhao M, Liu Z, Sha Y, et al. Readout-segmented echo-planar imaging in the evaluation of sinonasal lesions: a comprehensive comparison of image quality in single-shot echo-planar imaging. Magn Reson Imaging. 2016;34:166\u201372.","journal-title":"Magn Reson Imaging"},{"key":"438_CR16","doi-asserted-by":"publisher","first-page":"435","DOI":"10.1097\/RLI.0000000000000248","volume":"51","author":"K Ikuhiro","year":"2016","unstructured":"Ikuhiro K, Takashi U, Yuichiro M, et al. Comparison of diffusion-weighted imaging in the human brain using readout-segmented EPI and PROPELLER turbo spin Echo with single-shot EPI at 7 T MRI. Investig Radiol. 2016;51:435\u20139.","journal-title":"Investig Radiol"},{"key":"438_CR17","doi-asserted-by":"publisher","first-page":"215","DOI":"10.1002\/jmri.1176","volume":"14","author":"KP Forbes","year":"2001","unstructured":"Forbes KP, Pipe JG, Bird CR, et al. PROPELLER MRI: clinical testing of a novel technique for quantification and compensation of head motion. J Magn Reson Imaging. 2001;14:215\u201322.","journal-title":"J Magn Reson Imaging"},{"key":"438_CR18","doi-asserted-by":"publisher","first-page":"42","DOI":"10.1002\/mrm.10014","volume":"47","author":"G Pipe James","year":"2002","unstructured":"Pipe James G, Farthing Victoria G, Forbes Kirsten P. Multishot diffusion-weighted FSE using PROPELLER MRI. Magn Reson Med. 2002;47:42\u201352.","journal-title":"Magn Reson Med"},{"key":"438_CR19","doi-asserted-by":"publisher","first-page":"1352","DOI":"10.2214\/AJR.17.18796","volume":"210","author":"T Kim","year":"2018","unstructured":"Kim T, Baek M, Park J, et al. Comparison of DWI methods in the pediatric brain: PROPELLER turbo spin-Echo imaging versus readout-segmented Echo-planar imaging versus single-shot Echo-planar imaging. AJR Am J Roentgenol. 2018;210:1352\u20138.","journal-title":"AJR Am J Roentgenol"},{"issue":"1","key":"438_CR20","doi-asserted-by":"publisher","first-page":"54","DOI":"10.1097\/MAO.0b013e31818edf4a","volume":"30","author":"RC Dhepnorrarat","year":"2009","unstructured":"Dhepnorrarat RC, Wood B, Rajan GP. Postoperative non-echo-planar diffusion-weighted magnetic resonance imaging changes after cholesteatoma surgery: implications for cholesteatoma screening. Otology Neurotol. 2009;30(1):54\u20138.","journal-title":"Otology Neurotol"},{"issue":"12","key":"438_CR21","doi-asserted-by":"publisher","first-page":"1597","DOI":"10.1016\/j.acra.2019.02.002","volume":"26","author":"H Houchun","year":"2019","unstructured":"Houchun H, McAllister Aaron S, Ning J, et al. Comparison of 2D BLADE turbo gradient- and spin-Echo and 2D spin-Echo Echo-planar diffusion-weighted brain MRI at 3 T: preliminary experience in children. Acad Radiol. 2019;26(12):1597 undefined: undefined.","journal-title":"Acad Radiol"},{"key":"438_CR22","doi-asserted-by":"publisher","unstructured":"Lips LMJ, Nelemans PJ, Theunissen FMD, et al. The diagnostic accuracy of 1.5 T versus 3 T non-echo-planar diffusion-weighted imaging in the detection of residual or recurrent cholesteatoma in the middle ear and mastoid. J Neuroradiol. 2019;S0150-9861(18)30332-8. https:\/\/doi.org\/10.1016\/j.neurad.2019.02.013.","DOI":"10.1016\/j.neurad.2019.02.013"},{"key":"438_CR23","doi-asserted-by":"publisher","first-page":"265","DOI":"10.1148\/radiology.173.1.2781018","volume":"173","author":"L Kaufman","year":"1989","unstructured":"Kaufman L, Kramer DM, Crooks LE, et al. Measuring signal-to-noise ratios in MR imaging. Radiology. 1989;173:265\u20137.","journal-title":"Radiology"},{"key":"438_CR24","doi-asserted-by":"publisher","first-page":"1053","DOI":"10.1364\/AO.43.001053","volume":"43","author":"X Song","year":"2004","unstructured":"Song X, Pogue Brian W, Shudong J, et al. Automated region detection based on the contrast-to-noise ratio in near-infrared tomography. Appl Opt. 2004;43:1053\u201362.","journal-title":"Appl Opt"},{"key":"438_CR25","doi-asserted-by":"publisher","first-page":"143","DOI":"10.1016\/j.anorl.2010.07.001","volume":"127","author":"J Nevoux","year":"2010","unstructured":"Nevoux J, Lenoir M, Roger G, et al. Childhood cholesteatoma. Eur Ann Otorhinolaryngol Head Neck Dis. 2010;127:143\u201350.","journal-title":"Eur Ann Otorhinolaryngol Head Neck Dis"},{"key":"438_CR26","doi-asserted-by":"publisher","first-page":"28","DOI":"10.1186\/1748-717X-4-28","volume":"4","author":"J Tyng Chiang","year":"2009","unstructured":"Tyng Chiang J, Rubens C, Pinto Paula NV, et al. Conformal radiotherapy for lung cancer: interobservers\u2019 variability in the definition of gross tumor volume between radiologists and radiotherapists. Radiat Oncol. 2009;4:28.","journal-title":"Radiat Oncol"},{"key":"438_CR27","doi-asserted-by":"publisher","first-page":"613","DOI":"10.1177\/001316447303300309","volume":"33","author":"JL Fleiss","year":"1973","unstructured":"Fleiss JL, Cohen J. The equivalence of weighted kappa and the intraclass correlation coefficient as measures of reliability. Educ Psychol Meas. 1973;33:613\u20139.","journal-title":"Educ Psychol Meas"},{"issue":"10","key":"438_CR28","doi-asserted-by":"publisher","first-page":"656","DOI":"10.1097\/RLI.0b013e3181af3f0e","volume":"44","author":"UI Attenberger","year":"2009","unstructured":"Attenberger UI, Runge VM, Stemmer A, Williams KD, et al. Diffusion weighted imaging: a comprehensive evaluation of a fast spin echo DWI sequence with BLADE (PROPELLER) k-space sampling at 3 T, using a 32-channel head coil in acute brain ischemia. Investig Radiol. 2009;44(10):656\u201361.","journal-title":"Investig Radiol"},{"key":"438_CR29","doi-asserted-by":"publisher","first-page":"841","DOI":"10.1007\/s00234-007-0268-3","volume":"49","author":"B De Foer","year":"2007","unstructured":"De Foer B, Vercruysse JP, Bernaerts A, Maes J, et al. The value of single-shot turbo spin-echo diffusion-weighted MR imaging in the detection of middle ear cholesteatoma. Neuroradiology. 2007;49:841\u20138.","journal-title":"Neuroradiology"},{"key":"438_CR30","doi-asserted-by":"publisher","first-page":"1363","DOI":"10.3174\/ajnr.A1100","volume":"29","author":"F Venail","year":"2008","unstructured":"Venail F, Bonafe A, Poirrier V, et al. Comparison of echo-planar diffusion-weighted imaging and delayed postcontrast T1-weighted MR imaging for the detection of residual cholesteatoma. AJNR Am J Neuroradiol. 2008;29:1363\u20138.","journal-title":"AJNR Am J Neuroradiol"},{"key":"438_CR31","doi-asserted-by":"publisher","first-page":"468","DOI":"10.1002\/mrm.22024","volume":"62","author":"A Porter David","year":"2009","unstructured":"Porter David A, Heidemann Robin M. High resolution diffusion-weighted imaging using readout-segmented echo-planar imaging, parallel imaging and a two-dimensional navigator-based reacquisition. Magn Reson Med. 2009;62:468\u201375.","journal-title":"Magn Reson Med"},{"key":"438_CR32","doi-asserted-by":"publisher","first-page":"169","DOI":"10.1007\/s00330-002-1423-1","volume":"13","author":"T Williams Marc","year":"2003","unstructured":"Williams Marc T, Denis A, Corinne A, et al. Detection of postoperative residual cholesteatoma with delayed contrast-enhanced MR imaging: initial findings. Eur Radiol. 2003;13:169\u201374.","journal-title":"Eur Radiol"},{"key":"438_CR33","doi-asserted-by":"publisher","first-page":"341","DOI":"10.1002\/mrm.23033","volume":"66","author":"Z Li","year":"2011","unstructured":"Li Z, Pipe James G, Chu-Yu L, et al. X-PROP: a fast and robust diffusion-weighted propeller technique. Magn Reson Med. 2011;66:341\u20137.","journal-title":"Magn Reson Med"},{"key":"438_CR34","first-page":"7945482","volume":"2018","author":"R Camilla","year":"2018","unstructured":"Camilla R, Andrea E, Di Lullo Antonella M, et al. ADC benchmark range for correct diagnosis of primary and recurrent middle ear cholesteatoma. Biomed Res Int. 2018;2018:7945482.","journal-title":"Biomed Res Int"},{"key":"438_CR35","doi-asserted-by":"publisher","first-page":"1123","DOI":"10.3174\/ajnr.A1473","volume":"30","author":"S Thiriat","year":"2009","unstructured":"Thiriat S, Riehm S, Kremer S, et al. Apparent diffusion coefficient values of middle ear cholesteatoma differ from abscess and cholesteatoma admixed infection. AJNR Am J Neuroradiol. 2009;30:1123\u20136.","journal-title":"AJNR Am J Neuroradiol"}],"container-title":["BMC Medical Imaging"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12880-020-00438-7.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s12880-020-00438-7\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12880-020-00438-7.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,4,18]],"date-time":"2021-04-18T19:18:50Z","timestamp":1618773530000},"score":1,"resource":{"primary":{"URL":"https:\/\/bmcmedimaging.biomedcentral.com\/articles\/10.1186\/s12880-020-00438-7"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,4,19]]},"references-count":35,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2020,12]]}},"alternative-id":["438"],"URL":"https:\/\/doi.org\/10.1186\/s12880-020-00438-7","relation":{"has-preprint":[{"id-type":"doi","id":"10.21203\/rs.2.21206\/v2","asserted-by":"object"},{"id-type":"doi","id":"10.21203\/rs.2.21206\/v3","asserted-by":"object"},{"id-type":"doi","id":"10.21203\/rs.2.21206\/v1","asserted-by":"object"}]},"ISSN":["1471-2342"],"issn-type":[{"value":"1471-2342","type":"electronic"}],"subject":[],"published":{"date-parts":[[2020,4,19]]},"assertion":[{"value":"11 December 2019","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"30 March 2020","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"19 April 2020","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"This study was approved by the Review Committee of Eye & ENT Hospital of Fudan University, and written informed consent was obtained from all patients. For participants under 16\u2009years old, written informed consent was obtained from a parent or guardian.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Not Applicable.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare that they have no competing interests.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"40"}}