{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,2,21]],"date-time":"2025-02-21T10:59:46Z","timestamp":1740135586275,"version":"3.37.3"},"reference-count":35,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2021,1,11]],"date-time":"2021-01-11T00:00:00Z","timestamp":1610323200000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"},{"start":{"date-parts":[[2021,1,11]],"date-time":"2021-01-11T00:00:00Z","timestamp":1610323200000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"name":"Projekt DEAL"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Med Imaging"],"published-print":{"date-parts":[[2021,12]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:sec>\n                <jats:title>Background<\/jats:title>\n                <jats:p>Despite synchronization to respiration, respiration-navigated (RN) 3D turbo-spin-echo MRCP is limited by susceptibility to motion artifacts. The aim of this study was to assess the quality of pancreaticobiliary duct visualization of a non-RN MRCP alternative based on balanced steady-state free precession imaging (BSSFP) with overlapping slices compared with RN-MRCP.\n<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Methods<\/jats:title>\n                <jats:p>This is a retrospective study on 50 patients without pancreaticobiliary duct disease receiving MRCP at 1.5\u00a0T. We performed an intraindividual comparison of coronal RN-MRCP with combined coronal and transverse BSSFP-MRCP. Image quality was scored by 3 readers for 6 pancreaticobiliary duct segments (3 pancreatic, 3 biliary) using a 6-point scale. A segment score of 3 or lower as assessed by at least 2 of 3 readers was defined as insufficient segment visualization. Nonparametric tests and interrater reliability testing were used for statistical analysis.\n<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Results<\/jats:title>\n                <jats:p>Overall duct visualization averaged over all readers was scored with 4.5\u2009\u00b1\u20091.1 for RN-MRCP (pancreatic, 4.1\u2009\u00b1\u20090.5; biliary, 5.0\u2009\u00b1\u20090.4) and 4.9\u2009\u00b1\u20090.9 for combined coronal and transverse BSSFP-MRCP (pancreatic, 4.6\u2009\u00b1\u20090.6; biliary, 5.1\u2009\u00b1\u20090.6), respectively (<jats:italic>p<\/jats:italic>\u2009&lt;\u20090.001). The number of segments visualized insufficiently was 81\/300 for RN-MRCP and 43\/300 for BSSFP-MRCP (<jats:italic>p<\/jats:italic>\u2009&lt;\u20090.001). Segments visualized insufficiently only in RN-MRCP had a mean score of 4.4\u2009\u00b1\u20090.8 in BSSFP-MRCP. Overall interrater agreement on superiority of BSSFP-MRCP segment scores over corresponding RN-MRCP was 0.70. Mean acquisition time was 98% longer for RN-MRCP (198.0\u2009\u00b1\u200998.7\u00a0s) than for combined coronal and transverse BSSFP-MRCP (100.2\u2009\u00b1\u20090.4\u00a0s).<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Conclusions<\/jats:title>\n                <jats:p>Non-RN BSSFP-MRCP with overlapping slices is a fast alternative to RN-MRCP, frequently providing sufficient duct visualization when RN-MRCP fails.<\/jats:p>\n              <\/jats:sec>","DOI":"10.1186\/s12880-020-00532-w","type":"journal-article","created":{"date-parts":[[2021,1,11]],"date-time":"2021-01-11T19:14:27Z","timestamp":1610392467000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":2,"title":["Balanced steady-state free precession MRCP is a robust alternative to respiration-navigated 3D turbo-spin-echo MRCP"],"prefix":"10.1186","volume":"21","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-0438-8247","authenticated-orcid":false,"given":"Felix Christian","family":"Hasse","sequence":"first","affiliation":[]},{"given":"Buket","family":"Selmi","sequence":"additional","affiliation":[]},{"given":"Hamed","family":"Albusaidi","sequence":"additional","affiliation":[]},{"given":"Theresa","family":"Mokry","sequence":"additional","affiliation":[]},{"given":"Philipp","family":"Mayer","sequence":"additional","affiliation":[]},{"given":"Christian","family":"Rupp","sequence":"additional","affiliation":[]},{"given":"Hans-Ulrich","family":"Kauczor","sequence":"additional","affiliation":[]},{"given":"Tim Frederik","family":"Weber","sequence":"additional","affiliation":[]}],"member":"297","published-online":{"date-parts":[[2021,1,11]]},"reference":[{"issue":"3","key":"532_CR1","doi-asserted-by":"publisher","first-page":"805","DOI":"10.1148\/radiology.181.3.1947101","volume":"181","author":"BK Wallner","year":"1991","unstructured":"Wallner BK, Schumacher KA, Weidenmaier W, Friedrich JM. Dilated biliary tract: evaluation with MR cholangiography with a T2-weighted contrast-enhanced fast sequence. Radiology. 1991;181(3):805\u20138.","journal-title":"Radiology"},{"issue":"2","key":"532_CR2","doi-asserted-by":"publisher","first-page":"578","DOI":"10.1148\/radiology.183.2.1561373","volume":"183","author":"K Morimoto","year":"1992","unstructured":"Morimoto K, Shimoi M, Shirakawa T, Aoki Y, Choi S, Miyata Y, Hara K. Biliary obstruction: evaluation with three-dimensional MR cholangiography. Radiology. 1992;183(2):578\u201380.","journal-title":"Radiology"},{"issue":"3","key":"532_CR3","doi-asserted-by":"publisher","first-page":"162","DOI":"10.1111\/j.1751-2980.2008.00339.x","volume":"9","author":"K Hekimoglu","year":"2008","unstructured":"Hekimoglu K, Ustundag Y, Dusak A, Erdem Z, Karademir B, Aydemir S, Gundogdu S. MRCP vs. ERCP in the evaluation of biliary pathologies: review of current literature. J Dig Dis. 2008;9(3):162\u20139.","journal-title":"J Dig Dis"},{"issue":"4","key":"532_CR4","doi-asserted-by":"publisher","first-page":"e513","DOI":"10.1016\/j.ejrad.2011.06.004","volume":"81","author":"JH Kim","year":"2012","unstructured":"Kim JH, Hong SS, Eun HW, Han JK, Choi BI. Clinical usefulness of free-breathing navigator-triggered 3D MRCP in non-cooperative patients: comparison with conventional breath-hold 2D MRCP. Eur J Radiol. 2012;81(4):e513\u20138.","journal-title":"Eur J Radiol"},{"issue":"3","key":"532_CR5","doi-asserted-by":"publisher","first-page":"673","DOI":"10.1002\/jmri.21485","volume":"28","author":"S Morita","year":"2008","unstructured":"Morita S, Ueno E, Suzuki K, Machida H, Fujimura M, Kojima S, Hirata M, Ohnishi T, Imura C. Navigator-triggered prospective acquisition correction (PACE) technique vs conventional respiratory-triggered technique for free-breathing 3D MRCP: an initial prospective comparative study using healthy volunteers. J Magn Reson Imaging. 2008;28(3):673\u20137.","journal-title":"J Magn Reson Imaging"},{"issue":"9","key":"532_CR6","doi-asserted-by":"publisher","first-page":"939","DOI":"10.1016\/j.mri.2005.07.002","volume":"23","author":"P Asbach","year":"2005","unstructured":"Asbach P, Klessen C, Kroencke TJ, Kluner C, Stemmer A, Hamm B, Taupitz M. Magnetic resonance cholangiopancreatography using a free-breathing T2-weighted turbo spin-echo sequence with navigator-triggered prospective acquisition correction. Magn Reson Imaging. 2005;23(9):939\u201345.","journal-title":"Magn Reson Imaging"},{"issue":"1","key":"532_CR7","doi-asserted-by":"publisher","first-page":"94","DOI":"10.1002\/jmri.21038","volume":"27","author":"JY Choi","year":"2008","unstructured":"Choi JY, Lee JM, Lee JY, Kim SH, Lee MW, Han JK, Choi BI. Navigator-triggered isotropic three-dimensional magnetic resonance cholangiopancreatography in the diagnosis of malignant biliary obstructions: comparison with direct cholangiography. J Magn Reson Imaging. 2008;27(1):94\u2013101.","journal-title":"J Magn Reson Imaging"},{"issue":"3","key":"532_CR8","doi-asserted-by":"publisher","first-page":"363","DOI":"10.1097\/RCT.0b013e3181852193","volume":"33","author":"LS Yoon","year":"2009","unstructured":"Yoon LS, Catalano OA, Fritz S, Ferrone CR, Hahn PF, Sahani DV. Another dimension in magnetic resonance cholangiopancreatography: comparison of 2- and 3-dimensional magnetic resonance cholangiopancreatography for the evaluation of intraductal papillary mucinous neoplasm of the pancreas. J Comput Assist Tomogr. 2009;33(3):363\u20138.","journal-title":"J Comput Assist Tomogr"},{"issue":"11","key":"532_CR9","doi-asserted-by":"publisher","first-page":"e113882","DOI":"10.1371\/journal.pone.0113882","volume":"9","author":"S Kinner","year":"2014","unstructured":"Kinner S, Steinweg V, Maderwald S, Radtke A, Sotiropoulos G, Forsting M, Schroeder T. Comparison of different magnetic resonance cholangiography techniques in living liver donors including Gd-EOB-DTPA enhanced T1-weighted sequences. PLoS ONE. 2014;9(11):e113882.","journal-title":"PLoS ONE"},{"issue":"1","key":"532_CR10","doi-asserted-by":"publisher","first-page":"17","DOI":"10.1067\/mge.2002.120324","volume":"55","author":"AC Taylor","year":"2002","unstructured":"Taylor AC, Little AF, Hennessy OF, Banting SW, Smith PJ, Desmond PV. Prospective assessment of magnetic resonance cholangiopancreatography for noninvasive imaging of the biliary tree. Gastrointest Endosc. 2002;55(1):17\u201322.","journal-title":"Gastrointest Endosc"},{"issue":"1","key":"532_CR11","doi-asserted-by":"publisher","first-page":"33","DOI":"10.1186\/s12880-019-0329-1","volume":"19","author":"N Bogveradze","year":"2019","unstructured":"Bogveradze N, Hasse F, Mayer P, Rupp C, Tjaden C, Klauss M, Kauczor HU, Weber TF. Is MRCP necessary to diagnose pancreas divisum? BMC Med Imaging. 2019;19(1):33.","journal-title":"BMC Med Imaging"},{"issue":"6","key":"532_CR12","doi-asserted-by":"publisher","first-page":"1309","DOI":"10.1007\/s00261-014-0153-6","volume":"39","author":"JF Glockner","year":"2014","unstructured":"Glockner JF, Lee CU. Balanced steady state-free precession (b-SSFP) imaging for MRCP: techniques and applications. Abdom Imaging. 2014;39(6):1309\u201322.","journal-title":"Abdom Imaging"},{"issue":"8","key":"532_CR13","doi-asserted-by":"publisher","first-page":"1263","DOI":"10.1016\/j.mri.2013.06.008","volume":"31","author":"JF Glockner","year":"2013","unstructured":"Glockner JF, Saranathan M, Bayram E, Lee CU. Breath-held MR cholangiopancreatography (MRCP) using a 3D Dixon fat-water separated balanced steady state free precession sequence. Magn Reson Imaging. 2013;31(8):1263\u201370.","journal-title":"Magn Reson Imaging"},{"issue":"1","key":"532_CR14","doi-asserted-by":"publisher","first-page":"159","DOI":"10.2307\/2529310","volume":"33","author":"JR Landis","year":"1977","unstructured":"Landis JR, Koch GG. The measurement of observer agreement for categorical data. Biometrics. 1977;33(1):159\u201374.","journal-title":"Biometrics"},{"issue":"3","key":"532_CR15","doi-asserted-by":"publisher","first-page":"692","DOI":"10.1002\/mrm.20389","volume":"53","author":"A Lu","year":"2005","unstructured":"Lu A, Brodsky E, Grist TM, Block WF. Rapid fat-suppressed isotropic steady-state free precession imaging using true 3D multiple-half-echo projection reconstruction. Magn Reson Med. 2005;53(3):692\u20139.","journal-title":"Magn Reson Med"},{"issue":"3","key":"532_CR16","doi-asserted-by":"publisher","first-page":"557","DOI":"10.1002\/mrm.20790","volume":"55","author":"J Leupold","year":"2006","unstructured":"Leupold J, Hennig J, Scheffler K. Alternating repetition time balanced steady state free precession. Magn Reson Med. 2006;55(3):557\u201365.","journal-title":"Magn Reson Med"},{"issue":"1","key":"532_CR17","doi-asserted-by":"publisher","first-page":"117","DOI":"10.1002\/jmri.10435","volume":"19","author":"A Lu","year":"2004","unstructured":"Lu A, Barger AV, Grist TM, Block WFJ. Improved spectral selectivity and reduced susceptibility in SSFP using a near zero TE undersampled three-dimensional PR sequence. Magn Reson Imaging. 2004;19(1):117\u201323.","journal-title":"Magn Reson Imaging"},{"issue":"6","key":"532_CR18","doi-asserted-by":"publisher","first-page":"1533","DOI":"10.1002\/mrm.21921","volume":"61","author":"T Cukur","year":"2009","unstructured":"Cukur T, Lee JH, Bangerter NK, Hargreaves BA, Nishimura DG. Non-contrast-enhanced flow-independent peripheral MR angiography with balanced SSFP. Magn Reson Med. 2009;61(6):1533\u20139.","journal-title":"Magn Reson Med"},{"issue":"6","key":"532_CR19","doi-asserted-by":"publisher","first-page":"2226","DOI":"10.1002\/mrm.26630","volume":"78","author":"A Slawig","year":"2017","unstructured":"Slawig A, Wech T, Ratz V, Tran-Gia J, Neubauer H, Bley T, K\u00f6stler H. Multifrequency reconstruction for frequency-modulated bSSFP. Magn Reson Med. 2017;78(6):2226\u201335.","journal-title":"Magn Reson Med"},{"issue":"5","key":"532_CR20","doi-asserted-by":"publisher","first-page":"931","DOI":"10.1002\/mrm.21296","volume":"58","author":"KS Nayak","year":"2007","unstructured":"Nayak KS, Lee HL, Hargreaves BA, Hu BS. Wideband SSFP: alternating repetition time balanced steady state free precession with increased band spacing. Magn Reson Med. 2007;58(5):931\u20138.","journal-title":"Magn Reson Med"},{"issue":"5","key":"532_CR21","doi-asserted-by":"publisher","first-page":"876","DOI":"10.1002\/(SICI)1522-2594(199911)42:5<876::AID-MRM6>3.0.CO;2-Z","volume":"42","author":"SS Vasanawala","year":"1999","unstructured":"Vasanawala SS, Pauly JM, Nishimura DG. Fluctuating equilibrium MRI. Magn Reson Med. 1999;42(5):876\u201383.","journal-title":"Magn Reson Med"},{"issue":"2","key":"532_CR22","doi-asserted-by":"publisher","first-page":"934","DOI":"10.1002\/mrm.27446","volume":"81","author":"S Ozdemir","year":"2019","unstructured":"Ozdemir S, Ider YZ. bSSFP phase correction and its use in magnetic resonance electrical properties tomography. Magn Reson Med. 2019;81(2):934\u201346.","journal-title":"Magn Reson Med"},{"key":"532_CR23","doi-asserted-by":"publisher","first-page":"53","DOI":"10.1016\/j.ejrad.2019.04.002","volume":"115","author":"FK Loh\u00f6fer","year":"2019","unstructured":"Loh\u00f6fer FK, Kaissis GA, Rasper M, Katemann C, Hock A, Peeters JM, Schlag C, Rummeny EJ, Karampinos D, Braren RF. Magnetic resonance cholangiopancreatography at 3 Tesla: image quality comparison between 3D compressed sensing and 2D single-shot acquisitions. Eur J Radiol. 2019;115:53\u20138.","journal-title":"Eur J Radiol"},{"issue":"9","key":"532_CR24","doi-asserted-by":"publisher","first-page":"3721","DOI":"10.1007\/s00330-017-5275-0","volume":"28","author":"JG Nam","year":"2018","unstructured":"Nam JG, Lee JM, Kang HJ, Lee SM, Kim E, Peeters JM, Yoon JH. GRASE Revisited: breath-hold three-dimensional (3D) magnetic resonance cholangiopancreatography using a Gradient and Spin Echo (GRASE) technique at 3T. Eur Radiol. 2018;28(9):3721\u20138.","journal-title":"Eur Radiol"},{"issue":"6","key":"532_CR25","doi-asserted-by":"publisher","first-page":"2436","DOI":"10.1007\/s00330-017-5240-y","volume":"28","author":"M Yoshida","year":"2018","unstructured":"Yoshida M, Nakaura T, Inoue T, Tanoue S, Takada S, Utsunomiya D, Tsumagari S, Harada K, Yamashita Y. Magnetic resonance cholangiopancreatography with GRASE sequence at 3.0T: Does it improve image quality and acquisition time as compared with 3D TSE? Eur Radiol. 2018;28(6):2436\u201343.","journal-title":"Eur Radiol"},{"key":"532_CR26","doi-asserted-by":"publisher","first-page":"131","DOI":"10.1016\/j.mri.2018.05.015","volume":"52","author":"A Furlan","year":"2018","unstructured":"Furlan A, Bayram E, Thangasamy S, Barley D, Dasyam A. Application of compressed sensing to 3D magnetic resonance cholangiopancreatography for the evaluation of pancreatic cystic lesions. Magn Reson Imaging. 2018;52:131\u20136.","journal-title":"Magn Reson Imaging"},{"issue":"5","key":"532_CR27","doi-asserted-by":"publisher","first-page":"1289","DOI":"10.1002\/jmri.25672","volume":"46","author":"N Seo","year":"2017","unstructured":"Seo N, Park MS, Han K, Kim D, King KF, Choi JY, Kim H, Kim HJ, Lee M, Bae H, Kim MJ. Feasibility of 3D navigator-triggered magnetic resonance cholangiopancreatography with combined parallel imaging and compressed sensing reconstruction at 3T. J Magn Reson Imaging. 2017;46(5):1289\u201397.","journal-title":"J Magn Reson Imaging"},{"issue":"10","key":"532_CR28","doi-asserted-by":"publisher","first-page":"612","DOI":"10.1097\/RLI.0000000000000380","volume":"52","author":"JH Yoon","year":"2017","unstructured":"Yoon JH, Lee SM, Kang HJ, Weiland E, Raithel E, Son Y, Kiefer B, Lee JM. Clinical feasibility of 3-dimensional magnetic resonance cholangiopancreatography using compressed sensing: comparison of image quality and diagnostic performance. Invest Radiol. 2017;52(10):612\u20139.","journal-title":"Invest Radiol"},{"issue":"11","key":"532_CR29","doi-asserted-by":"publisher","first-page":"681","DOI":"10.1097\/RLI.0000000000000489","volume":"53","author":"J Taron","year":"2018","unstructured":"Taron J, Weiss J, Notohamiprodjo M, Kuestner T, Bamberg F, Weiland E, Kuehn B, Martirosian P. Acceleration of magnetic resonance cholangiopancreatography using compressed sensing at 1.5 and 3 T: a clinical feasibility study. Invest Radiol. 2018;53(11):681\u20138.","journal-title":"Invest Radiol"},{"key":"532_CR30","doi-asserted-by":"publisher","DOI":"10.1007\/s00261-020-02403-y","author":"D Morimoto","year":"2020","unstructured":"Morimoto D, Hyodo T, Kamata K, Kadoba T, Itoh M, Fukushima H, Chiba Y, Takenaka M, Mochizuki T, Ueda Y, Miyagoshi K, Kudo M, Ishii K. Navigator-triggered and breath-hold 3D MRCP using compressed sensing: image quality and method selection factor assessment. Abdom Radiol (NY). 2020. https:\/\/doi.org\/10.1007\/s00261-020-02403-y.","journal-title":"Abdom Radiol (NY)"},{"issue":"9","key":"532_CR31","doi-asserted-by":"publisher","first-page":"2255","DOI":"10.1007\/s00261-017-1451-6","volume":"43","author":"H Kwon","year":"2018","unstructured":"Kwon H, Reid S, Kim D, Lee S, Cho J, Oh J. Diagnosing common bile duct obstruction: comparison of image quality and diagnostic performance of three-dimensional magnetic resonance cholangiopancreatography with and without compressed sensing. Abdom Radiol (NY). 2018;43(9):2255\u201361.","journal-title":"Abdom Radiol (NY)"},{"issue":"3","key":"532_CR32","doi-asserted-by":"publisher","first-page":"150","DOI":"10.1097\/RLI.0000000000000421","volume":"53","author":"L Zhu","year":"2018","unstructured":"Zhu L, Wu X, Sun Z, Jin Z, Weiland E, Raithel E, Qian T, Xue H. Compressed-sensing accelerated 3-dimensional magnetic resonance cholangiopancreatography: application in suspected pancreatic diseases. Invest Radiol. 2018;53(3):150\u20137.","journal-title":"Invest Radiol"},{"issue":"7","key":"532_CR33","doi-asserted-by":"publisher","first-page":"1749","DOI":"10.1007\/s00330-010-1714-x","volume":"20","author":"S Kinner","year":"2010","unstructured":"Kinner S, Dech\u00eane A, Ladd SC, Z\u00f6pf T, de Dech\u00eane EM, Gerken G, Lauenstein TC. Comparison of different MRCP techniques for the depiction of biliary complications after liver transplantation. Eur Radiol. 2010;20(7):1749\u201356.","journal-title":"Eur Radiol"},{"issue":"1","key":"532_CR34","doi-asserted-by":"publisher","first-page":"e2","DOI":"10.1148\/radiographics.22.1.g02jae2e2","volume":"22","author":"C Matos","year":"2002","unstructured":"Matos C, Cappeliez O, Winant C, Coppens E, Devi\u00e8re J, Metens T. MR imaging of the pancreas: a pictorial tour. Radiographics. 2002;22(1):e2.","journal-title":"Radiographics"},{"issue":"2","key":"532_CR35","doi-asserted-by":"publisher","first-page":"403","DOI":"10.1148\/radiology.217.2.r00nv29403","volume":"217","author":"R Manfredi","year":"2000","unstructured":"Manfredi R, Costamagna G, Brizi MG, Spina S, Maresca G, Vecchioli A, Mutignani M, Marano P. Pancreas divisum and \u201csantorinicele\u201d: diagnosis with dynamic MR cholangiopancreatography with secretin stimulation. Radiology. 2000;217(2):403\u20138.","journal-title":"Radiology"}],"container-title":["BMC Medical Imaging"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1186\/s12880-020-00532-w.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1186\/s12880-020-00532-w\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1186\/s12880-020-00532-w.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,1,14]],"date-time":"2021-01-14T23:03:41Z","timestamp":1610665421000},"score":1,"resource":{"primary":{"URL":"https:\/\/bmcmedimaging.biomedcentral.com\/articles\/10.1186\/s12880-020-00532-w"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,1,11]]},"references-count":35,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2021,12]]}},"alternative-id":["532"],"URL":"https:\/\/doi.org\/10.1186\/s12880-020-00532-w","relation":{},"ISSN":["1471-2342"],"issn-type":[{"type":"electronic","value":"1471-2342"}],"subject":[],"published":{"date-parts":[[2021,1,11]]},"assertion":[{"value":"26 September 2020","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"29 November 2020","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"11 January 2021","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"Approval was obtained by the Clinical Ethics Committee of the Heidelberg University Hospital.Consent for publication.Not applicable.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"The authors declare that they have no competing interests.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"10"}}