{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,7]],"date-time":"2026-05-07T07:09:18Z","timestamp":1778137758042,"version":"3.51.4"},"reference-count":11,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2022,1,5]],"date-time":"2022-01-05T00:00:00Z","timestamp":1641340800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2022,1,5]],"date-time":"2022-01-05T00:00:00Z","timestamp":1641340800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Med Imaging"],"published-print":{"date-parts":[[2022,12]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:sec>\n                <jats:title>Background<\/jats:title>\n                <jats:p>This study aimed to investigate the effect of automatic exposure compensation (AEC)\n of intraoral radiographic systems on the gray values of dental tissues in images acquired with or without high-density material in the exposed region using different exposure times and kilovoltages. The influence of the distance of the high-density material was also investigated.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Methods<\/jats:title>\n                <jats:p>Radiographs from the molar region of two mandibles were obtained using the RVG 6100 and the Express systems, operating at 60 and 70\u00a0kV and 0.06, 0.10, and 0.16\u00a0s. Subsequently, a titanium implant was inserted in the premolar\u2019s socket and other images were acquired. Using the ImageJ software, two regions of interest were determined on the enamel, coronary dentine, root dentine, and pulp of the first and second molars to obtain their gray values.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Results<\/jats:title>\n                <jats:p>In the RVG 6100, the implant did not affect the gray values (<jats:italic>p<\/jats:italic>\u00a0&gt;\u00a00.05); the increase in kV decreased it in all tissues (<jats:italic>p<\/jats:italic>\u00a0&lt;\u00a00.05), and the exposure time affected only the root dentine and pulp. In the Express, only enamel and coronary dentine values changed (<jats:italic>p<\/jats:italic>\u00a0&lt;\u00a00.05), decreasing with the implant presence and\/or with the increase in exposure factors. The distance of the implant did not affect the results (<jats:italic>p<\/jats:italic>\u00a0&gt;\u00a00.05).<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Conclusions<\/jats:title>\n                <jats:p>AEC\u2019s performance varies between the radiographic systems. Its effect on the gray values depends not only on the presence or absence of high-density material but also on the kV and exposure time used.<\/jats:p>\n              <\/jats:sec>","DOI":"10.1186\/s12880-021-00733-x","type":"journal-article","created":{"date-parts":[[2022,1,5]],"date-time":"2022-01-05T03:02:41Z","timestamp":1641351761000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":9,"title":["Automatic exposure compensation in intraoral digital radiography: effect on the gray values of dental tissues"],"prefix":"10.1186","volume":"22","author":[{"given":"Evelyn Rute Carneiro","family":"Maciel","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Eduarda Helena Leandro","family":"Nascimento","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hugo","family":"Ga\u00eata-Araujo","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Maria Luiza dos Anjos","family":"Pontual","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Andrea dos Anjos","family":"Pontual","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Fl\u00e1via Maria Moraes","family":"Ramos-Perez","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2022,1,5]]},"reference":[{"key":"733_CR1","doi-asserted-by":"publisher","first-page":"239","DOI":"10.5624\/isd.2016.46.4.239","volume":"46","author":"K Rovaris","year":"2016","unstructured":"Rovaris K, Vasconcelos K, dedo Nascimento EHL, Oliveira ML, Freitas DQ, Haiter-Neto F. Brazilian young dental practitioners\u2019 use and acceptance of digital radiographic examinations. Imaging Sci Dent. 2016;46:239\u201344.","journal-title":"Imaging Sci Dent"},{"key":"733_CR2","doi-asserted-by":"publisher","first-page":"2637","DOI":"10.1007\/s00330-010-1836-1","volume":"20","author":"B Vandenberghe","year":"2010","unstructured":"Vandenberghe B, Jacobs R, Bosmans H. Modern dental imaging: a review of the current technology and clinical applications in dental practice. Eur Radiol. 2010;20:2637\u201355.","journal-title":"Eur Radiol"},{"issue":"SUPPL.","key":"733_CR3","doi-asserted-by":"publisher","first-page":"S7","DOI":"10.14219\/jada.archive.2008.0357","volume":"139","author":"PF van der Stelt","year":"2008","unstructured":"van der Stelt PF. Better imaging. J Am Dent Assoc. 2008;139(SUPPL.):S7-13.","journal-title":"J Am Dent Assoc"},{"key":"733_CR4","doi-asserted-by":"publisher","first-page":"140","DOI":"10.1259\/dmfr\/88681265","volume":"34","author":"K Yoshiura","year":"2005","unstructured":"Yoshiura K, Nakayama E, Shimizu M, Goto TK, Chikui T, Kawazu T, et al. Effects of the automatic exposure compensation on the proximal caries diagnosis. Dentomaxillofac Radiol. 2005;34:140\u20134.","journal-title":"Dentomaxillofac Radiol"},{"key":"733_CR5","volume-title":"Oral radiology. Principles and interpretation","author":"C Stuart","year":"2013","unstructured":"Stuart C, White MJP. Oral radiology. Principles and interpretation. 7th ed. Mosby\/Elsevier; 2013.","edition":"7"},{"key":"733_CR6","doi-asserted-by":"publisher","first-page":"2","DOI":"10.1259\/dmfr.20180331","volume":"48","author":"NS Galv\u00e3o","year":"2019","unstructured":"Galv\u00e3o NS, Nascimento EHL, Lima CAS, Freitas DQ, Haiter-Neto F, Oliveira ML. Can a high-density dental material affect the automatic exposure compensation of digital radiographic images? Dentomaxillofac Radiol. 2019;48:2\u20137.","journal-title":"Dentomaxillofac Radiol"},{"key":"733_CR7","doi-asserted-by":"publisher","first-page":"211","DOI":"10.1259\/dmfr.25.4.9084276","volume":"25","author":"Y Hayakawa","year":"1996","unstructured":"Hayakawa Y, Farman AG, Scarfe WC, Kuroyanagi K. Technical report. Processing to achieve high-contrast images with computed dental radiography. Dentomaxillofac Radiol. 1996;25:211\u20134.","journal-title":"Dentomaxillofac Radiol."},{"key":"733_CR8","doi-asserted-by":"publisher","first-page":"11","DOI":"10.1007\/BF02351577","volume":"12","author":"Y Hayakawa","year":"1996","unstructured":"Hayakawa Y, Farman AG, Scarfe WC, Kuroyanagi K. Pixel value modification using RVG-4 automatic exposure compensation for instant high-contrast images. Oral Radiol. 1996;12:11\u20138.","journal-title":"Oral Radiol"},{"key":"733_CR9","doi-asserted-by":"publisher","first-page":"191","DOI":"10.1259\/dmfr\/25806978","volume":"32","author":"K Yoshiura","year":"2003","unstructured":"Yoshiura K, Welander U, McDavid W, Li G, Shi X-Q, Kawazu T, et al. Perceptibility curves for the Digora system. Dentomaxillofac Radiol. 2003;32:191\u20137.","journal-title":"Dentomaxillofac Radiol"},{"key":"733_CR10","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1155\/2017\/5215413","volume":"2017","author":"O Dashpuntsag","year":"2017","unstructured":"Dashpuntsag O, Yoshida M, Kasai R, Maeda N, Hosoki H, Honda E. Numerical evaluation of image contrast for thicker and thinner objects among current intraoral digital imaging systems. Biomed Res Int. 2017;2017:1\u201310.","journal-title":"Biomed Res Int"},{"key":"733_CR11","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1590\/1807-3107bor-2020.vol34.0082","volume":"34","author":"NS Galv\u00e3o","year":"2020","unstructured":"Galv\u00e3o NS, Leandro Nascimento EH, Ga\u00eata-Araujo H, Freitas DQ, Haiter-Neto F, Oliveira ML. Automatic exposure compensation and subjective image enhancement in the radiographic diagnosis of caries. Braz Oral Res. 2020;34:1\u20138.","journal-title":"Braz Oral Res"}],"container-title":["BMC Medical Imaging"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12880-021-00733-x.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s12880-021-00733-x\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12880-021-00733-x.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,1,5]],"date-time":"2022-01-05T03:02:45Z","timestamp":1641351765000},"score":1,"resource":{"primary":{"URL":"https:\/\/bmcmedimaging.biomedcentral.com\/articles\/10.1186\/s12880-021-00733-x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,1,5]]},"references-count":11,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2022,12]]}},"alternative-id":["733"],"URL":"https:\/\/doi.org\/10.1186\/s12880-021-00733-x","relation":{},"ISSN":["1471-2342"],"issn-type":[{"value":"1471-2342","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,1,5]]},"assertion":[{"value":"12 September 2021","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"28 December 2021","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"5 January 2022","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"This study was approved by the Research Ethics Committee of the Federal University of Pernambuco (protocol #3.594.302). All procedures performed were in accordance with the ethical standards of the Institutional and National Research Committee and with the 1964 Helsinki declaration and its later amendments or comparable ethical standards. The informed consent requirement for this ex vivo study was waived by the Research Ethics Committee of the Federal University of Pernambuco.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Not applicable.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare that they have no competing interests.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"4"}}