{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,5,27]],"date-time":"2025-05-27T18:26:50Z","timestamp":1748370410204,"version":"3.37.3"},"reference-count":29,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2022,11,24]],"date-time":"2022-11-24T00:00:00Z","timestamp":1669248000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2022,11,24]],"date-time":"2022-11-24T00:00:00Z","timestamp":1669248000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Med Imaging"],"abstract":"<jats:title>Abstract<\/jats:title><jats:sec>\n                <jats:title>Background<\/jats:title>\n                <jats:p>The purpose of the retrospective study was to analyze the reliability and repeatability of specific landmark-positions used in cephalometry to determine the major sources of absolute landmark position differences for repeated, time-separated (time-point I and II) digital cephalometric radiographs (CEPH) of the same patients.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Methods<\/jats:title>\n                <jats:p>100 pairs of CPEHs from the database of a sample of adult patients (18 to 28 years) were analyzed by one calibrated observer and three landmark points (Sella: S, Nasion: N, Subspinale: A) were digitally marked using ImageJ-software. The coordinates of these points entered the evaluation using displacement vectors as primary endpoints between the coordinates of the landmarks in the two images as well as SNA-angles and the angle \u03c9 of SN relative to the floor.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Results<\/jats:title>\n                <jats:p>Displacement vectors between CEPHI and CEPHII were rather large (N: 7.95\u2009\u00b1\u20094.85\u00a0mm, S: 5.34\u2009\u00b1\u20093.50\u00a0mm, A: 4.81\u2009\u00b1\u20093.95\u00a0mm.\u00a0SNA was rather stable between the two sequential radiographs (mean difference: 0.002\u00b0 \u00b1 1.85\u00b0). and did not correlate with age of the patient (SNA<jats:sub>I<\/jats:sub>: spearman-Rho: 0.0239, <jats:italic>p<\/jats:italic>\u2009=\u20090.8134; SNA<jats:sub>II<\/jats:sub> : spearman-Rho: 0.0244, <jats:italic>p<\/jats:italic>\u2009=\u20090.8096). Although the vertical angle \u03c9 did not differ between CEPH<jats:sub>I<\/jats:sub> and CEPH<jats:sub>II<\/jats:sub> (mean difference: 0.4\u00b0 \u00b1 4.7\u00b0, p<jats:sub>wilcoxon<\/jats:sub> = 0.8155), it showed a quadratic relationship (p<jats:sub>F\u2212statistic<\/jats:sub>: &lt; 2.2e\u221216) with the length of the displacement vector N.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Conclusion<\/jats:title>\n                <jats:p>The significantly varying location of the reference points S, N and A between time-separated CEPHs of one patient can largely be explained by different angulation (head rotation within the sagittal plane) of the Frankfurt plane to the floor (horizontal plane).<\/jats:p>\n              <\/jats:sec>","DOI":"10.1186\/s12880-022-00935-x","type":"journal-article","created":{"date-parts":[[2022,11,25]],"date-time":"2022-11-25T19:47:42Z","timestamp":1669405662000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":2,"title":["Vertical head rotation as major source of differences between time-separated digital cephalometric radiographs of patients acquired in one cephalostat X-ray device"],"prefix":"10.1186","volume":"22","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-7880-0046","authenticated-orcid":false,"given":"Ralf K. W.","family":"Schulze","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Lea K. M.","family":"Linnerth","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2022,11,24]]},"reference":[{"key":"935_CR1","first-page":"115","volume":"51","author":"RM Rickets","year":"1981","unstructured":"Rickets RM. Perspectives in the clinical application of cephalometrics: the first fifty years. Angle Orthod. 1981;51:115\u201350.","journal-title":"Angle Orthod"},{"key":"935_CR2","first-page":"447","volume":"64","author":"DE Johnson","year":"1994","unstructured":"Johnson DE, Hesse KL, Glover KE. Landmark identification error in posterior anterior cephalometrics. Angle Orthod. 1994;64:447\u201354.","journal-title":"Angle Orthod"},{"key":"935_CR3","doi-asserted-by":"publisher","first-page":"101","DOI":"10.1259\/dmfr.1983.0017","volume":"12","author":"J Ahlqvist","year":"1983","unstructured":"Ahlqvist J, Eliasson S, Welander U. The cephalometric projection. Part II. Principles of image distortion in cephalography. Dentomaxillofac Radiol. 1983;12:101\u20138.","journal-title":"Dentomaxillofac Radiol"},{"key":"935_CR4","doi-asserted-by":"publisher","first-page":"100","DOI":"10.1259\/dmfr\/82724776","volume":"39","author":"R Nal\u00e7aci","year":"2010","unstructured":"Nal\u00e7aci R, Ozt\u00fcrk F, S\u00f6k\u00fcc\u00fc O. A comparison of two-dimensional radiography and three-dimensional computed tomography in angular cephalometric measurements. Dentomaxillofac Radiol. 2010;39:100\u20136.","journal-title":"Dentomaxillofac Radiol"},{"key":"935_CR5","doi-asserted-by":"publisher","first-page":"31","DOI":"10.1186\/2196-1042-14-31","volume":"14","author":"AR Dur\u00e3o","year":"2013","unstructured":"Dur\u00e3o AR, Pittayapat P, Rockenbach MI, Olszewski R, Ng S, Ferreira AP, Jacobs R. Validity of 2D lateral cephalometry in orthodontics: a systematic review. Prog Orthod. 2013;14:31.","journal-title":"Prog Orthod"},{"key":"935_CR6","doi-asserted-by":"publisher","first-page":"630","DOI":"10.1093\/ejo\/cjn059","volume":"30","author":"PG Nijkamp","year":"2008","unstructured":"Nijkamp PG, Habets LLMH, Aartman IHA, Zentner A. The influence of cephalometrics on orthodontic treatment planning. Eur J Orthod. 2008;30:630\u20135.","journal-title":"Eur J Orthod"},{"key":"935_CR7","first-page":"35","volume":"7","author":"R Gaddam","year":"2015","unstructured":"Gaddam R, Shashikumar HC, Lokesh NK, Suma T, Arya S, Shwetha GS. Assessment of Image distortion from head rotation in lateral cephalometry. J Int Oral Health. 2015;7:35\u201340.","journal-title":"J Int Oral Health"},{"key":"935_CR8","doi-asserted-by":"publisher","first-page":"117","DOI":"10.1259\/dmfr.1982.0015","volume":"11","author":"S Eliasson","year":"1982","unstructured":"Eliasson S, Welander U, Ahlqvist J. The cephalographic projection. Part I: general considerations. Dentomaxillofac Radiol. 1982;11:117\u201322.","journal-title":"Dentomaxillofac Radiol"},{"key":"935_CR9","first-page":"396","volume":"71","author":"YJ Yoon","year":"2001","unstructured":"Yoon YJ, Kim KS, Hwang MS, Kim HJ, Choi EH, Kim KW. Effect of head rotation on lateral cephalometric radiographs. Angle Orthod. 2001;71:396\u2013403.","journal-title":"Angle Orthod"},{"key":"935_CR10","doi-asserted-by":"publisher","first-page":"353","DOI":"10.1093\/ejo\/10.1.353","volume":"10","author":"J Ahlqvist","year":"1988","unstructured":"Ahlqvist J, Eliasson S, Welander U. The effect of projection errors on angular measurements in cephalometry. Eur J Orthod. 1988;10:353\u201361.","journal-title":"Eur J Orthod"},{"key":"935_CR11","doi-asserted-by":"publisher","first-page":"315","DOI":"10.1093\/ejo\/cjh098","volume":"27","author":"S Malkoc","year":"2005","unstructured":"Malkoc S, Sari Z, Usumez S, Koyuturk AE. The effect of head rotation on cephalometric radiographs. Eur J Orthod. 2005;27:315\u201321.","journal-title":"Eur J Orthod"},{"key":"935_CR12","first-page":"311","volume":"35","author":"SK Nanda","year":"1965","unstructured":"Nanda SK, Sassouni V. Planes of reference in roentgenographic cephalometry. Angle Orthod. 1965;35:311\u20139.","journal-title":"Angle Orthod"},{"key":"935_CR13","doi-asserted-by":"publisher","first-page":"598","DOI":"10.1016\/j.ajodo.2008.07.018","volume":"137","author":"MO Lagrav\u00e8re","year":"2010","unstructured":"Lagrav\u00e8re MO, Low C, Flores-Mir C, Chung R, Carey JP, Heo G, et al. Intraexaminer and interexaminer reliabilities of landmark identification on digitized lateral cephalograms and formatted 3-dimensional cone-beam computerized tomography images. Am J Orthod Dentofacial Orthop. 2010;137:598\u2013604.","journal-title":"Am J Orthod Dentofacial Orthop"},{"key":"935_CR14","doi-asserted-by":"publisher","first-page":"44","DOI":"10.1179\/bjo.11.1.44","volume":"11","author":"AM Cohen","year":"1984","unstructured":"Cohen AM. Uncertainty in cephalometrics. Br J Orthod. 1984;11:44\u20138.","journal-title":"Br J Orthod"},{"key":"935_CR15","doi-asserted-by":"publisher","first-page":"11","DOI":"10.1259\/dmfr\/37010910","volume":"41","author":"SF Albarakati","year":"2012","unstructured":"Albarakati SF, Kula KS, Ghoneima AA. The reliability and reproducibility of cephalometric measurements: a comparison of conventional and digital methods. Dentomaxillofac Radiol. 2012;41:11\u20137.","journal-title":"Dentomaxillofac Radiol"},{"key":"935_CR16","doi-asserted-by":"publisher","first-page":"437","DOI":"10.2319\/061513-451.1","volume":"84","author":"C Goracci","year":"2014","unstructured":"Goracci C, Ferrari M. Reproducibility of measurements in tablet-assisted, PC-aided, and manual cephalometric analysis. Angle Orthod. 2014;84:437\u201342.","journal-title":"Angle Orthod"},{"key":"935_CR17","doi-asserted-by":"publisher","first-page":"424","DOI":"10.4103\/0975-7406.163488","volume":"7","author":"N Meiyappan","year":"2015","unstructured":"Meiyappan N, Tamizharasi S, Senthilkumar KP, Janardhanan K. Natural head position: an overview. J Pharm Bioallied Sci. 2015;7:424\u20137.","journal-title":"J Pharm Bioallied Sci"},{"key":"935_CR18","doi-asserted-by":"publisher","first-page":"812","DOI":"10.1016\/0002-9416(48)90015-3","volume":"34","author":"WB Downs","year":"1948","unstructured":"Downs WB. Variations in facial relationships; their significance in treatment and prognosis. Am J Orthod. 1948;34:812\u201340.","journal-title":"Am J Orthod"},{"key":"935_CR19","unstructured":"R. A language and environment for statistical computing. [Online] 2017. http:\/\/www.R-project.org\/."},{"key":"935_CR20","doi-asserted-by":"publisher","first-page":"307","DOI":"10.1016\/S0140-6736(86)90837-8","volume":"1","author":"JM Bland","year":"1986","unstructured":"Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet. 1986;1:307\u201310.","journal-title":"Lancet"},{"key":"935_CR21","doi-asserted-by":"publisher","first-page":"505","DOI":"10.1016\/0002-9416(71)90116-3","volume":"60","author":"S Baumrind","year":"1971","unstructured":"Baumrind S, Frantz RC. The reliability of head film measurements. 2. Conventional angular and linear measures. Am J Orthod. 1971;60:505\u201317.","journal-title":"Am J Orthod"},{"key":"935_CR22","doi-asserted-by":"publisher","first-page":"967","DOI":"10.2319\/070107-301.1","volume":"78","author":"Y Gu","year":"2008","unstructured":"Gu Y, McNamara JA. Cephalometric superimpositions. Angle Orthod. 2008;78:967\u201376.","journal-title":"Angle Orthod"},{"key":"935_CR23","doi-asserted-by":"publisher","first-page":"175","DOI":"10.1016\/S0889-5406(94)70036-2","volume":"106","author":"SE Bishara","year":"1994","unstructured":"Bishara SE, Treder JE, Jakobsen JR. Facial and dental changes in adulthood. Am J Orthod Dentofacial Orthop. 1994;106:175\u201386.","journal-title":"Am J Orthod Dentofacial Orthop"},{"key":"935_CR24","volume-title":"An atlas of craniofacial growth. Craniofacial growth series, monograph 2","author":"ML Riolo","year":"1974","unstructured":"Riolo ML, et al. An atlas of craniofacial growth. Craniofacial growth series, monograph 2. Ann Arbor: Center for Human Growth and Development, University of Michigan; 1974."},{"key":"935_CR25","doi-asserted-by":"publisher","first-page":"277","DOI":"10.1007\/s00056-012-0090-3","volume":"73","author":"O Bondevik","year":"2012","unstructured":"Bondevik O. Dentofacial changes in adults: a longitudinal cephalometric study in 22\u201333 and 33\u201343 year olds. J Orofac Orthop. 2012;73:277\u201388.","journal-title":"J Orofac Orthop"},{"key":"935_CR26","doi-asserted-by":"publisher","first-page":"672","DOI":"10.1177\/00220345620410032101","volume":"41","author":"A Bj\u00f6rk","year":"1962","unstructured":"Bj\u00f6rk A, Solow B. Measurement on radiographs. J Dent Res. 1962;41:672\u201383.","journal-title":"J Dent Res"},{"issue":"3","key":"935_CR27","doi-asserted-by":"publisher","first-page":"149","DOI":"10.1093\/ejo\/8.3.149","volume":"8","author":"WJB Houston","year":"1986","unstructured":"Houston WJB, et al. Sources of error in measurements from cephalometric radiographs. Eur J Orthod. 1986;8(3):149\u201351.","journal-title":"Eur J Orthod"},{"key":"935_CR28","doi-asserted-by":"publisher","first-page":"213","DOI":"10.5624\/isd.2015.45.4.213","volume":"45","author":"AP Dur\u00e3o","year":"2015","unstructured":"Dur\u00e3o AP, et al. Cephalometric landmark variability among orthodontists and dentomaxillofacial radiologists: a comparative study. Imaging Sci Dent. 2015;45:213.","journal-title":"Imaging Sci Dent"},{"key":"935_CR29","doi-asserted-by":"publisher","first-page":"20120423","DOI":"10.1259\/dmfr.20120423","volume":"42","author":"RC Hoogeveen","year":"2013","unstructured":"Hoogeveen RC, Sanderink GCH, Berkhout WER. Effect of head position on cephalometric evaluation of the soft-tissue facial profile. Dentomaxillofacial Radiol. 2013;42:20120423.","journal-title":"Dentomaxillofacial Radiol"}],"container-title":["BMC Medical Imaging"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12880-022-00935-x.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s12880-022-00935-x\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12880-022-00935-x.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,11,26]],"date-time":"2022-11-26T00:30:07Z","timestamp":1669422607000},"score":1,"resource":{"primary":{"URL":"https:\/\/bmcmedimaging.biomedcentral.com\/articles\/10.1186\/s12880-022-00935-x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,11,24]]},"references-count":29,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2022,12]]}},"alternative-id":["935"],"URL":"https:\/\/doi.org\/10.1186\/s12880-022-00935-x","relation":{},"ISSN":["1471-2342"],"issn-type":[{"type":"electronic","value":"1471-2342"}],"subject":[],"published":{"date-parts":[[2022,11,24]]},"assertion":[{"value":"20 January 2022","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"11 November 2022","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"24 November 2022","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"All patients at the University Medical Center of Mainz sign a general agreement that their data may be used for scientific purposes in pseudonymized fashion. For the study only pseudonymized cepaholmetric radiographs were taken from the database, no patient was appointed or exposed for this study. As no further information was used and no patient data apart from those processed and pseudonymized data are included in the manuscript, ethical approval is not required according to the regulations at the University Medical Center of Mainz University Medical Center of Mainz (Ethics committee of the Rhineland-Palatinate Chamber of Physicians). Thus, no ethic approval had to be acquired for this type of quality assurance study basing on pseudonymized image data.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Not applicable.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare that they have no competing interests.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"208"}}