{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,9,10]],"date-time":"2025-09-10T22:26:26Z","timestamp":1757543186682},"reference-count":31,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2023,6,5]],"date-time":"2023-06-05T00:00:00Z","timestamp":1685923200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2023,6,5]],"date-time":"2023-06-05T00:00:00Z","timestamp":1685923200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Med Imaging"],"abstract":"<jats:title>Abstract<\/jats:title><jats:sec>\n                <jats:title>Background<\/jats:title>\n                <jats:p>This study aims to evaluate the effects of the artifact removal algorithm on linear measurements of the buccal cortical plate by altering the voltage.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Methods<\/jats:title>\n                <jats:p>Ten titanium fixtures were inserted at the site of central, lateral, canine, premolars and molars of dry human mandibles. Vertical height of buccal plate was measured using a digital caliper as a gold standard. Mandibles were scanned with 54 and 58 kVp. Other parameters were constant. Images were reconstructed with none, low, medium and high artifact removal modes. Two Oromaxillofacial radiologists evaluated and measured the buccal plate height using Romexis software. Statistical package for the social sciences (SPSS) version 24 was used for data analysis.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Results<\/jats:title>\n                <jats:p>In medium and high modes, the difference between 54 and 58 kVp was significant (<jats:italic>p<\/jats:italic>\u2009&lt;\u20090.001). No significance was noted by using low ARM (artifact removal mode) at the 54 kVp and 58 kVp.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Conclusion<\/jats:title>\n                <jats:p>Using artifact removal in low voltage decreases the accuracy of linear measurement and buccal crest visibility. By using high voltage, artifact removal would have no significant effect on accuracy of linear measurements.\n<\/jats:p>\n              <\/jats:sec>","DOI":"10.1186\/s12880-023-01025-2","type":"journal-article","created":{"date-parts":[[2023,6,5]],"date-time":"2023-06-05T10:02:48Z","timestamp":1685959368000},"update-policy":"http:\/\/dx.doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":3,"title":["Effect of metal artifact removal modes on the accuracy of linear measurement around titanium implants by applying different voltages: an original article"],"prefix":"10.1186","volume":"23","author":[{"given":"Daryoush","family":"Goodarzi Pour","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Elham","family":"Emami Meybodi","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Kosar","family":"Sodagar","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Zahra Alsadat","family":"Emami Meybodi","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Sanaz","family":"Safari","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2023,6,5]]},"reference":[{"issue":"6","key":"1025_CR1","doi-asserted-by":"publisher","first-page":"817","DOI":"10.1016\/j.oooo.2012.03.005","volume":"113","author":"DA Tyndall","year":"2012","unstructured":"Tyndall DA, Price JB, Tetradis S, Ganz SD, Hildebolt C, Scarfe WC. American Academy of Oral and Maxillofacial Radiology. Oral Surg Oral Med Oral Pathol Oral Radiol. 2012;113(6):817\u201326.","journal-title":"Oral Surg Oral Med Oral Pathol Oral Radiol"},{"issue":"7","key":"1025_CR2","doi-asserted-by":"publisher","first-page":"20140019","DOI":"10.1259\/dmfr.20140019","volume":"43","author":"A Parsa","year":"2014","unstructured":"Parsa A, Ibrahim N, Hassan B, Syriopoulos K, van der Stelt P. Assessment of metal artefact reduction around dental titanium implants in cone beam CT. Dentomaxillofac Radiol. 2014;43(7):20140019.","journal-title":"Dentomaxillofac Radiol"},{"issue":"4","key":"1025_CR3","doi-asserted-by":"publisher","first-page":"534","DOI":"10.1016\/j.tripleo.2006.04.008","volume":"103","author":"JB Ludlow","year":"2007","unstructured":"Ludlow JB, Laster WS, See M, Bailey LTJ, Hershey HG. Accuracy of measurements of mandibular anatomy in cone beam computed tomography images. Oral Surg Oral Med Oral Pathol Oral Radiol Endod. 2007;103(4):534\u201342.","journal-title":"Oral Surg Oral Med Oral Pathol Oral Radiol Endod"},{"issue":"1","key":"1025_CR4","doi-asserted-by":"publisher","first-page":"51","DOI":"10.1111\/prd.12161","volume":"73","author":"MM Bornstein","year":"2017","unstructured":"Bornstein MM, Horner K, Jacobs R. Use of cone beam computed tomography in implant dentistry: current concepts, indications and limitations for clinical practice and research. Periodontol 2000. 2017;73(1):51\u201372.","journal-title":"Periodontol 2000"},{"issue":"3","key":"1025_CR5","first-page":"143","volume":"13","author":"M Panjnoush","year":"2016","unstructured":"Panjnoush M, Kheirandish Y, Kashani PM, Fakhar HB, Younesi F, Mallahi M. Effect of exposure parameters on metal artifacts in cone beam computed tomography. J Dent (Tehran). 2016;13(3):143.","journal-title":"J Dent (Tehran)"},{"issue":"5","key":"1025_CR6","doi-asserted-by":"publisher","first-page":"560","DOI":"10.1111\/j.1600-0501.2011.02253.x","volume":"23","author":"GI Benic","year":"2012","unstructured":"Benic GI, Mokti M, Chen CJ, Weber HP, H\u00e4mmerle CH, Gallucci GO. Dimensions of buccal bone and mucosa at immediately placed implants after 7 years: a clinical and cone beam computed tomography study. Clin Oral Implants Res. 2012;23(5):560\u20136.","journal-title":"Clin Oral Implants Res"},{"issue":"5","key":"1025_CR7","doi-asserted-by":"publisher","first-page":"492","DOI":"10.1111\/clr.12424","volume":"26","author":"L Schropp","year":"2015","unstructured":"Schropp L, Wenzel A, Spin-Neto R, Stavropoulos A. Fate of the buccal bone at implants placed early, delayed, or late after tooth extraction analyzed by cone beam CT: 10-year results from a randomized, controlled, clinical study. Clin Oral Implants Res. 2015;26(5):492\u2013500.","journal-title":"Clin Oral Implants Res"},{"issue":"6","key":"1025_CR8","doi-asserted-by":"publisher","first-page":"657","DOI":"10.1016\/j.oooo.2016.01.010","volume":"121","author":"K Kamburo\u011flu","year":"2016","unstructured":"Kamburo\u011flu K, Y\u0131lmaz F, Yeta EN, \u00d6zen D. Assessment of furcal perforations in the vicinity of different root canal sealers using a cone beam computed tomography system with and without the application of artifact reduction mode: an ex vivo investigation on extracted human teeth. Oral Surg Oral Med Oral Pathol Oral Radiol. 2016;121(6):657\u201365.","journal-title":"Oral Surg Oral Med Oral Pathol Oral Radiol"},{"issue":"6","key":"1025_CR9","doi-asserted-by":"publisher","first-page":"440","DOI":"10.4103\/2231-0762.170523","volume":"5","author":"AK Nagarajappa","year":"2015","unstructured":"Nagarajappa AK, Dwivedi N, Tiwari R. Artifacts: the downturn of CBCT image. J Int Soc Prev Community Den. 2015;5(6):440.","journal-title":"J Int Soc Prev Community Den"},{"issue":"2","key":"1025_CR10","doi-asserted-by":"publisher","first-page":"209","DOI":"10.1002\/JPER.18-0433","volume":"91","author":"M Sheikhi","year":"2020","unstructured":"Sheikhi M, Behfarnia P, Mostajabi M, Nasri N. The efficacy of metal artifact reduction (MAR) algorithm in cone-beam computed tomography on the diagnostic accuracy of fenestration and dehiscence around dental implants. J Periodontol. 2020;91(2):209\u201314.","journal-title":"J Periodontol"},{"issue":"8","key":"1025_CR11","doi-asserted-by":"publisher","first-page":"20130176","DOI":"10.1259\/dmfr.20130176","volume":"42","author":"K Kamburo\u011flu","year":"2013","unstructured":"Kamburo\u011flu K, Kolsuz E, Murat S, Eren H, Y\u00fcksel S, Paksoy C. Assessment of buccal marginal alveolar peri-implant and periodontal defects using a cone beam CT system with and without the application of metal artefact reduction mode. Dentomaxillofac Radiol. 2013;42(8):20130176.","journal-title":"Dentomaxillofac Radiol"},{"issue":"5","key":"1025_CR12","doi-asserted-by":"publisher","first-page":"265","DOI":"10.1259\/dmfr\/30642039","volume":"40","author":"R Schulze","year":"2011","unstructured":"Schulze R, Heil U, Gro\u03b2 D, Bruellmann D, Dranischnikow E, Schwanecke U, et al. Artefacts in CBCT: a review. Dentomaxillofac Radiol. 2011;40(5):265\u201373.","journal-title":"Dentomaxillofac Radiol"},{"issue":"3","key":"1025_CR13","doi-asserted-by":"publisher","first-page":"170","DOI":"10.1259\/dmfr\/13603271","volume":"33","author":"M Cavalcanti","year":"2004","unstructured":"Cavalcanti M, Rocha S, Vannier M. Craniofacial measurements based on 3D-CT volume rendering: implications for clinical applications. Dentomaxillofac Radiol. 2004;33(3):170\u20136.","journal-title":"Dentomaxillofac Radiol"},{"issue":"1","key":"1025_CR14","doi-asserted-by":"publisher","first-page":"12","DOI":"10.1046\/j.0906-6713.2002.03302.x","volume":"33","author":"R Jacobs","year":"2003","unstructured":"Jacobs R. Preoperative radiologic planning of implant surgery in compromised patients. Periodontol 2000. 2003;33(1):12\u201325.","journal-title":"Periodontol 2000"},{"issue":"1","key":"1025_CR15","doi-asserted-by":"publisher","first-page":"28","DOI":"10.1259\/dmfr\/31342245","volume":"34","author":"R Marmulla","year":"2005","unstructured":"Marmulla R, Wortche R, Muhling J, Hassfeld S. Geometric accuracy of the NewTom 9000 cone beam CT. Dentomaxillofac Radiol. 2005;34(1):28\u201331.","journal-title":"Dentomaxillofac Radiol"},{"issue":"5","key":"1025_CR16","doi-asserted-by":"publisher","first-page":"550","DOI":"10.1016\/j.oooo.2016.01.013","volume":"121","author":"SL De-Azevedo-Vaz","year":"2016","unstructured":"De-Azevedo-Vaz SL, Peyneau PD, Ramirez-Sotelo LR, de Faria VK, Campos PSF, Haiter-Neto F. Efficacy of a cone beam computed tomography metal artifact reduction algorithm for the detection of peri-implant fenestrations and dehiscences. Oral Surg Oral Med Oral Pathol Oral Radiol. 2016;121(5):550\u20136.","journal-title":"Oral Surg Oral Med Oral Pathol Oral Radiol"},{"issue":"4","key":"1025_CR17","doi-asserted-by":"publisher","first-page":"469","DOI":"10.1118\/1.1357457","volume":"28","author":"M Endo","year":"2001","unstructured":"Endo M, Tsunoo T, Nakamori N, Yoshida K. Effect of scattered radiation on image noise in cone beam CT. Med phys. 2001;28(4):469\u201374.","journal-title":"Med phys"},{"issue":"2","key":"1025_CR18","doi-asserted-by":"publisher","first-page":"220","DOI":"10.1118\/1.1339879","volume":"28","author":"JH Siewerdsen","year":"2001","unstructured":"Siewerdsen JH, Jaffray DA. Cone-beam computed tomography with a flat-panel imager: magnitude and effects of x-ray scatter. Med phys. 2001;28(2):220\u201331.","journal-title":"Med phys"},{"issue":"4","key":"1025_CR19","doi-asserted-by":"publisher","first-page":"245","DOI":"10.5624\/isd.2018.48.4.245","volume":"48","author":"A Nikbin","year":"2018","unstructured":"Nikbin A, Dalili Kajan Z, Taramsari M, Khosravifard N. Effect of object position in the field of view and application of a metal artifact reduction algorithm on the detection of vertical root fractures on cone-beam computed tomography scans: an in vitro study. Imaging Sci Dent. 2018;48(4):245\u201354.","journal-title":"Imaging Sci Dent"},{"issue":"5","key":"1025_CR20","doi-asserted-by":"publisher","first-page":"20120245","DOI":"10.1259\/dmfr.20120245","volume":"42","author":"B Bechara","year":"2013","unstructured":"Bechara B, Alex McMahan C, Moore W, Noujeim M, Teixeira F, Geha H. Cone beam CT scans with and without artefact reduction in root fracture detection of endodontically treated teeth. Dentomaxillofac Radiol. 2013;42(5):20120245.","journal-title":"Dentomaxillofac Radiol"},{"issue":"6","key":"1025_CR21","doi-asserted-by":"publisher","first-page":"20140428","DOI":"10.1259\/dmfr.20140428","volume":"44","author":"I Bezerra","year":"2015","unstructured":"Bezerra I, Neves F, Vasconcelos T, Ambrosano G, Freitas D. Influence of the artefact reduction algorithm of Picasso Trio CBCT system on the diagnosis of vertical root fractures in teeth with metal posts. Dentomaxillofac Radiol. 2015;44(6):20140428.","journal-title":"Dentomaxillofac Radiol"},{"issue":"5","key":"1025_CR22","doi-asserted-by":"publisher","first-page":"422","DOI":"10.1259\/dmfr\/43691321","volume":"41","author":"B Bechara","year":"2012","unstructured":"Bechara B, McMahan C, Geha H, Noujeim M. Evaluation of a cone beam CT artefact reduction algorithm. Dentomaxillofac Radiol. 2012;41(5):422\u20138.","journal-title":"Dentomaxillofac Radiol"},{"issue":"3","key":"1025_CR23","doi-asserted-by":"publisher","first-page":"20160366","DOI":"10.1259\/dmfr.20160366","volume":"46","author":"PM Queiroz","year":"2017","unstructured":"Queiroz PM, Santaella GM, Da Paz TD, Freitas DQ. Evaluation of a metal artefact reduction tool on different positions of a metal object in the FOV. Dentomaxillofac Radiol. 2017;46(3):20160366.","journal-title":"Dentomaxillofac Radiol"},{"issue":"6","key":"1025_CR24","doi-asserted-by":"publisher","first-page":"1679","DOI":"10.1148\/rg.246045065","volume":"24","author":"JF Barrett","year":"2004","unstructured":"Barrett JF, Keat N. Artifacts in CT: recognition and avoidance. Radiographics. 2004;24(6):1679\u201391.","journal-title":"Radiographics"},{"issue":"4","key":"1025_CR25","doi-asserted-by":"publisher","first-page":"125","DOI":"10.1067\/j.cpradiol.2009.05.002","volume":"39","author":"ML Kataoka","year":"2010","unstructured":"Kataoka ML, Hochman MG, Rodriguez EK, Lin P-JP, Kubo S, Raptopolous VD. A review of factors that affect artifact from metallic hardware on multi-row detector computed tomography. Curr Probl Diagn Radiol. 2010;39(4):125\u201336.","journal-title":"Curr Probl Diagn Radiol"},{"issue":"1","key":"1025_CR26","doi-asserted-by":"publisher","first-page":"100","DOI":"10.1111\/j.1600-0501.2009.01817.x","volume":"21","author":"RKW Schulze","year":"2010","unstructured":"Schulze RKW, Berndt D, d\u2019Hoedt B. On cone-beam computed tomography artifacts induced by titanium implants. Clin Oral Implants Res. 2010;21(1):100\u20137.","journal-title":"Clin Oral Implants Res"},{"issue":"2","key":"1025_CR27","doi-asserted-by":"publisher","first-page":"114","DOI":"10.1007\/s11282-011-0071-z","volume":"27","author":"J Chindasombatjaroen","year":"2011","unstructured":"Chindasombatjaroen J, Kakimoto N, Murakami S, Maeda Y, Furukawa S. Quantitative analysis of metallic artifacts caused by dental metals: comparison of cone-beam and multi-detector row CT scanners. Oral Radiol. 2011;27(2):114\u201320.","journal-title":"Oral Radiol"},{"issue":"5","key":"1025_CR28","doi-asserted-by":"publisher","first-page":"264","DOI":"10.1259\/dmfr\/147454468","volume":"39","author":"F Draenert","year":"2010","unstructured":"Draenert F, Gebhart F, Berthold M, Gosau M, Wagner W. Evaluation of demineralized bone and bone transplants in vitro and in vivo with cone beam computed tomography imaging. Dentomaxillofac Radiol. 2010;39(5):264\u20139.","journal-title":"Dentomaxillofac Radiol"},{"issue":"2","key":"1025_CR29","first-page":"49","volume":"6","author":"F Esmaeili","year":"2012","unstructured":"Esmaeili F, Johari M, Haddadi P, Vatankhah M. Beam hardening artifacts: comparison between two cone beam computed tomography scanners. J Dent Res Dent clin Dent Prospects. 2012;6(2):49.","journal-title":"J Dent Res Dent clin Dent Prospects"},{"issue":"1","key":"1025_CR30","doi-asserted-by":"publisher","first-page":"20140224","DOI":"10.1259\/dmfr.20140224","volume":"44","author":"R Pauwels","year":"2015","unstructured":"Pauwels R, Araki K, Siewerdsen J, Thongvigitmanee SS. Technical aspects of dental CBCT: state of the art. Dentomaxillofac Radiol. 2015;44(1):20140224.","journal-title":"Dentomaxillofac Radiol"},{"key":"1025_CR31","unstructured":"Misch CE. Dental implant prosthetics-e-book. Elsevier Health Sciences; 2004."}],"container-title":["BMC Medical Imaging"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12880-023-01025-2.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s12880-023-01025-2\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12880-023-01025-2.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,6,5]],"date-time":"2023-06-05T10:05:07Z","timestamp":1685959507000},"score":1,"resource":{"primary":{"URL":"https:\/\/bmcmedimaging.biomedcentral.com\/articles\/10.1186\/s12880-023-01025-2"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,6,5]]},"references-count":31,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2023,12]]}},"alternative-id":["1025"],"URL":"https:\/\/doi.org\/10.1186\/s12880-023-01025-2","relation":{},"ISSN":["1471-2342"],"issn-type":[{"value":"1471-2342","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,6,5]]},"assertion":[{"value":"25 December 2022","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"23 May 2023","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"5 June 2023","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Ethics committee of Tehran University of Medical Sciences approved the study.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Not applicable.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare no competing interests.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"74"}}