{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,22]],"date-time":"2026-09-22T04:56:20Z","timestamp":1790052980078,"version":"4.0.1"},"reference-count":17,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2024,4,22]],"date-time":"2024-04-22T00:00:00Z","timestamp":1713744000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2024,4,22]],"date-time":"2024-04-22T00:00:00Z","timestamp":1713744000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Med Imaging"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Background<\/jats:title>\n                    <jats:p>Large field of view CZT SPECT cameras with a ring geometry are available for some years now. Thanks to their good sensitivity and high temporal resolution, general dynamic SPECT imaging may be performed more easily, without resorting to dedicated systems. To evaluate the dynamic SPECT imaging by such cameras, we have performed an in vivo pilot study to analyze the kidney function of a pig and compare the results to standard dynamic planar imaging by a conventional gamma camera.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>\n                      A 7-week-old (12\u00a0kg) female Landrace pig was injected with [\n                      <jats:sup>99m<\/jats:sup>\n                      Tc]Tc-MAG3 and a 30\u00a0min dynamic SPECT acquisition of the kidneys was performed on a CZT ring camera. A fast SPECT\/CT was acquired with the same camera immediately after the dynamic SPECT, without moving the pig, and used for attenuation correction and drawing regions of interest. The next day the same pig underwent a dynamic planar imaging of the kidneys by a conventional 2-head gamma camera. The dynamic SPECT acquisition was reconstructed using a MLEM algorithm with up to 20 iterations, with and without attenuation correction. Time-activity curves of the total counts of each kidney were extracted from 2D and 3D dynamic images. An adapted 2-compartment model was derived to fit the data points and extract physiological parameters. Comparison of these parameters was performed between the different reconstructions and acquisitions.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>Time-activity curves were nicely fitted with the 2-compartment model taking into account the anesthesia and bladder filling. Kidney physiological parameters were found in agreement with literature values. Good agreement of these parameters was obtained for the right kidney between dynamic SPECT and planar imaging. Regional analysis of the kidneys can be performed in the case of the dynamic SPECT imaging and provided good agreement with the whole kidney results.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>Dynamic SPECT imaging is feasible with CZT swiveling-detector ring cameras and provides results in agreement with dynamic planar imaging by conventional gamma cameras. Regional analysis of organs uptake and clearance becomes possible. Further studies are required regarding the optimization of acquisition and reconstruction parameters to improve image quality and enable absolute quantification.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1186\/s12880-024-01271-y","type":"journal-article","created":{"date-parts":[[2024,4,22]],"date-time":"2024-04-22T08:02:14Z","timestamp":1713772934000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":8,"title":["Kidney dynamic SPECT acquisition on a CZT swiveling-detector ring camera: an in vivo pilot study"],"prefix":"10.1186","volume":"24","author":[{"given":"Michel","family":"Hesse","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Florian","family":"Dupont","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Nizar","family":"Mourad","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Pavel","family":"Babczenko","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Gwen","family":"Beaurin","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Daela","family":"Xhema","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Eliano","family":"Bonaccorsi-Riani","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Fran\u00e7ois","family":"Jamar","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Renaud","family":"Lhommel","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2024,4,22]]},"reference":[{"key":"1271_CR1","doi-asserted-by":"publisher","first-page":"R111","DOI":"10.1088\/0031-9155\/55\/20\/R01","volume":"55","author":"GT Gullberg","year":"2010","unstructured":"Gullberg GT, Reutter BW, Sitek A, et al. Dynamic single photon emission computed tomography\u2013 basic principles and cardiac applications. Phys Med Biol. 2010;55:R111\u201391.","journal-title":"Phys Med Biol"},{"key":"1271_CR2","doi-asserted-by":"publisher","first-page":"4489","DOI":"10.1118\/1.3589129","volume":"38","author":"T Humphries","year":"2011","unstructured":"Humphries T, Celler A, Trummer M. Slow-rotation dynamic SPECT with a temporal second derivative constraint. Med Phys. 2011;38:4489\u201396.","journal-title":"Med Phys"},{"key":"1271_CR3","doi-asserted-by":"publisher","first-page":"104002","DOI":"10.1088\/0266-5611\/32\/10\/104002","volume":"32","author":"M Burger","year":"2016","unstructured":"Burger M, Rossmanith C, Zhang X. Simultaneous reconstruction and segmentation for dynamic SPECT imaging. Inverse Probl. 2016;32:104002.","journal-title":"Inverse Probl"},{"key":"1271_CR4","first-page":"474","volume":"34","author":"RK Rowe","year":"1993","unstructured":"Rowe RK, Aarvold JN, Barrett HH, et al. A stationary hemispherical SPECT imager for three-dimensional brain imaging. J Nuc Med. 1993;34:474\u201380.","journal-title":"J Nuc Med"},{"key":"1271_CR5","doi-asserted-by":"publisher","first-page":"2635","DOI":"10.1088\/0031-9155\/54\/9\/003","volume":"54","author":"K Erlandsson","year":"2009","unstructured":"Erlandsson K, Kacperski K, van Gramberg D, Hutton BF. Performance evaluation of D-SPECT: a novel SPECT system for nuclear cardiology. Phys Med Biol. 2009;54:2635.","journal-title":"Phys Med Biol"},{"key":"1271_CR6","doi-asserted-by":"crossref","unstructured":"Aarsvold JN, Galt JR, Nye JA, Grammens FD, Glass ZA. The quality field of view of a discovery 530c. In 2012 IEEE Nuclear Science Symposium and Medical Imaging Conference Record (NSS\/MIC). IEEE, 2012:3551\u20133555.","DOI":"10.1109\/NSSMIC.2012.6551813"},{"issue":"supplement 1","key":"1271_CR7","first-page":"1384","volume":"60","author":"C Desmonts","year":"2019","unstructured":"Desmonts C, Bouthiba MA, Enilorac B, Agostini D, Aide N. Performance evaluation of a new multipurpose whole-body CZT-based camera: comparison with a dual head anger camera. J Nucl Med. 2019;60(supplement 1):1384.","journal-title":"J Nucl Med"},{"issue":"supplement 1","key":"1271_CR8","first-page":"1125","volume":"52","author":"G Le Rouzic","year":"2021","unstructured":"Le Rouzic G, Zananiri R. First performance measurements of a new multi-detector CZT-based SPECT\/CT system: GE Starguide. J Nucl Med. 2021;52(supplement 1):1125.","journal-title":"J Nucl Med"},{"key":"1271_CR9","doi-asserted-by":"publisher","first-page":"492","DOI":"10.1111\/j.1464-410X.1990.tb14793.x","volume":"65","author":"DA Jones","year":"1990","unstructured":"Jones DA, Lupton EW, George NJR. Effect of bladder filling on upper tract urodynamics in man. Br J Urol. 1990;65:492\u20136.","journal-title":"Br J Urol"},{"key":"1271_CR10","doi-asserted-by":"publisher","first-page":"146","DOI":"10.1007\/BF02440038","volume":"3","author":"IPC Murray","year":"1996","unstructured":"Murray IPC, Ell PJ. Nuclear medicine in clinical diagnosis and treatment, 1. Emerg Radiol. 1996;3:146\u20137.","journal-title":"Emerg Radiol"},{"key":"1271_CR11","doi-asserted-by":"publisher","first-page":"F454","DOI":"10.1152\/ajprenal.00413.2009","volume":"298","author":"F Jouret","year":"2010","unstructured":"Jouret F, Walrand S, Parreira KS, Courtoy PJ, Pauwels S, Devuyst O, Jamar F. Single photon emission-computed tomography (SPECT) for functional investigation of the proximal tubule in conscious mice. Am J Physiol Ren Physiol. 2010;298:F454\u201360.","journal-title":"Am J Physiol Ren Physiol"},{"key":"1271_CR12","first-page":"3295","volume":"49","author":"E Mairal","year":"2022","unstructured":"Mairal E, Imbert L, Marie PY, Bahloul A. Three-phase bone quantitative-SPECT of navicular bones with a high-sensitivity whole-body CZT-camera in a M\u00fceller-Weiss syndrome. EJNMMI. 2022;49:3295\u20136.","journal-title":"EJNMMI"},{"key":"1271_CR13","first-page":"1837","volume":"50","author":"M Bailly","year":"2023","unstructured":"Bailly M, Callaud A, Metrard G. Dynamic cardiac SPECT with flow measurement using 3D-ring CZT: when SPECT is inspired by PET. EJNMMI. 2023;50:1837\u20139.","journal-title":"EJNMMI"},{"key":"1271_CR14","first-page":"1308","volume":"28","author":"JA Bieszk","year":"1987","unstructured":"Bieszk JA, Hawman EG. Evaluation of SPECT angular sampling effects: continuous versus step-and-shoot acquisition. J Nucl Med. 1987;28:1308\u201314.","journal-title":"J Nucl Med"},{"key":"1271_CR15","doi-asserted-by":"publisher","first-page":"346","DOI":"10.2967\/jnmt.120.244574","volume":"48","author":"M Destine","year":"2020","unstructured":"Destine M, Seret A. Legendre polynomials: a fully automatic method for noise reduction in 99mTc-Mercaptoacetyltriglycine renogram analysis. J Nucl Med Technol. 2020;48:346\u2013453.","journal-title":"J Nucl Med Technol"},{"key":"1271_CR16","doi-asserted-by":"publisher","first-page":"1978","DOI":"10.1016\/j.juro.2012.07.002","volume":"188","author":"CK Rowe","year":"2012","unstructured":"Rowe CK, Franco FB, Barbosa JABA, Minnillo BJ, Chow JS, et al. A novel method of evaluating ureteropelvic junction obstruction: dynamic near infrared fluorescence imaging compared to standard modalities to assess urinary obstruction in a swine model. J Urol. 2012;188:1978\u201385.","journal-title":"J Urol"},{"key":"1271_CR17","doi-asserted-by":"publisher","first-page":"2530","DOI":"10.1016\/S0022-5347(05)65629-7","volume":"166","author":"NB Itano","year":"2001","unstructured":"Itano NB, Sherrill LE, Lerman LO, Corica FA, Hauser MF, et al. Electron beam computerized tomography assessment of in vivo single kidney glomerular filtration rate and tubular dynamics during chronic partial unilateral ureteral obstruction in the pig. J Urol. 2001;166:2530\u20135.","journal-title":"J Urol"}],"container-title":["BMC Medical Imaging"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12880-024-01271-y.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s12880-024-01271-y\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12880-024-01271-y.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,4,22]],"date-time":"2024-04-22T08:04:57Z","timestamp":1713773097000},"score":1,"resource":{"primary":{"URL":"https:\/\/bmcmedimaging.biomedcentral.com\/articles\/10.1186\/s12880-024-01271-y"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,4,22]]},"references-count":17,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2024,12]]}},"alternative-id":["1271"],"URL":"https:\/\/doi.org\/10.1186\/s12880-024-01271-y","relation":{},"ISSN":["1471-2342"],"issn-type":[{"value":"1471-2342","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,4,22]]},"assertion":[{"value":"12 February 2024","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"8 April 2024","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"22 April 2024","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"This study was approved by the local ethics committee related to experimentation on animals of the Universit\u00e9 Catholique de Louvain.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Not applicable.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare no competing interests.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"94"}}