{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,6]],"date-time":"2026-03-06T23:27:33Z","timestamp":1772839653372,"version":"3.50.1"},"reference-count":26,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2025,4,29]],"date-time":"2025-04-29T00:00:00Z","timestamp":1745884800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"},{"start":{"date-parts":[[2025,4,29]],"date-time":"2025-04-29T00:00:00Z","timestamp":1745884800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Med Imaging"],"DOI":"10.1186\/s12880-025-01623-2","type":"journal-article","created":{"date-parts":[[2025,4,29]],"date-time":"2025-04-29T15:11:02Z","timestamp":1745939462000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":2,"title":["Application of deep learning reconstruction combined with time-resolved post-processing method to improve image quality in CTA derived from low-dose cerebral CT perfusion data"],"prefix":"10.1186","volume":"25","author":[{"given":"Jiajing","family":"Tong","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Tong","family":"Su","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yu","family":"Chen","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Xiaobo","family":"Zhang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ming","family":"Yao","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yanling","family":"Wang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Haozhe","family":"Liu","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Min","family":"Xu","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jian","family":"Wang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Zhengyu","family":"Jin","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2025,4,29]]},"reference":[{"key":"1623_CR1","doi-asserted-by":"publisher","first-page":"1026","DOI":"10.3174\/ajnr.A4162","volume":"36","author":"HGJ Kortman","year":"2015","unstructured":"Kortman HGJ, Smit EJ, Oei MTH, et al. 4D-CTA in neurovascular disease: a review. AJNR Am J Neuroradiol. 2015;36:1026\u201333.","journal-title":"AJNR Am J Neuroradiol"},{"key":"1623_CR2","doi-asserted-by":"publisher","first-page":"216","DOI":"10.1148\/radiol.11111068","volume":"263","author":"EJ Smit","year":"2012","unstructured":"Smit EJ, Vonken E, van der Schaaf IC, et al. Timing-invariant reconstruction for deriving high-quality CT angiographic data from cerebral CT perfusion data. Radiology. 2012;263:216\u201325.","journal-title":"Radiology"},{"key":"1623_CR3","doi-asserted-by":"publisher","first-page":"25","DOI":"10.1097\/RCT.0b013e3182a3f9a0","volume":"38","author":"A Ringelstein","year":"2014","unstructured":"Ringelstein A, Lechel U, Fahrendorf DM, et al. Radiation exposure in perfusion CT of the brain. J Comput Assist Tomogr. 2014;38:25\u201328.","journal-title":"J Comput Assist Tomogr"},{"key":"1623_CR4","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1016\/j.neurad.2015.06.003","volume":"43","author":"AE Othman","year":"2016","unstructured":"Othman AE, Afat S, Brockmann MA, et al. Radiation dose reduction in perfusion CT imaging of the brain: a review of the literature. J Neuroradiol. 2016;43:1\u20135.","journal-title":"J Neuroradiol"},{"key":"1623_CR5","doi-asserted-by":"publisher","first-page":"2307","DOI":"10.1016\/j.ejrad.2015.07.011","volume":"84","author":"AM den Harder","year":"2015","unstructured":"den Harder AM, Willemink MJ, de Ruiter QMB, et al. Achievable dose reduction using iterative reconstruction for chest computed tomography: a systematic review. Eur J Radiol. 2015;84:2307\u201313.","journal-title":"Eur J Radiol"},{"key":"1623_CR6","doi-asserted-by":"publisher","first-page":"127","DOI":"10.2214\/AJR.17.18025","volume":"210","author":"M-ACD de","year":"2018","unstructured":"Mello-Amoedo CD de, Martins AN, Tachibana A, et al. Comparison of radiation dose and image quality of abdominopelvic CT using iterative (AIDR 3D) and conventional reconstructions. AJR Am J Roentgenol. 2018;210:127\u201333.","journal-title":"AJR Am J Roentgenol"},{"key":"1623_CR7","doi-asserted-by":"publisher","first-page":"491","DOI":"10.1148\/radiol.2019191422","volume":"293","author":"A Mileto","year":"2019","unstructured":"Mileto A, Guimaraes LS, McCollough CH, et al. State of the Art in Abdominal CT: the Limits of Iterative Reconstruction Algorithms. Radiology. 2019;293:491\u2013503.","journal-title":"Radiology"},{"key":"1623_CR8","doi-asserted-by":"publisher","first-page":"252","DOI":"10.1055\/a-1248-2556","volume":"193","author":"C Arndt","year":"2021","unstructured":"Arndt C, G\u00fcttler F, Heinrich A, et al. Deep Learning CT Image Reconstruction in Clinical Practice. Rofo. 2021;193:252\u201361.","journal-title":"Rofo"},{"key":"1623_CR9","doi-asserted-by":"publisher","first-page":"113","DOI":"10.1016\/j.ejmp.2020.11.012","volume":"79","author":"R Singh","year":"2020","unstructured":"Singh R, Wu W, Wang G, et al. Artificial intelligence in image reconstruction: the change is here. Phys Med. 2020;79:113\u201325.","journal-title":"Phys Med"},{"key":"1623_CR10","doi-asserted-by":"publisher","first-page":"3253","DOI":"10.1007\/s00330-023-09559-3","volume":"33","author":"Y Nagayama","year":"2023","unstructured":"Nagayama Y, Iwashita K, Maruyama N, et al. Deep learning-based reconstruction can improve the image quality of low radiation dose head CT. Eur Radiol. 2023;33:3253\u201365.","journal-title":"Eur Radiol"},{"key":"1623_CR11","doi-asserted-by":"publisher","first-page":"1534","DOI":"10.3390\/diagnostics13091534","volume":"13","author":"S Altmann","year":"2023","unstructured":"Altmann S, Abello Mercado MA, Ucar FA, et al. Ultra-high-resolution CT of the head and neck with deep learning reconstruction-assessment of image quality and radiation exposure and intraindividual comparison with normal-resolution CT. Diagnostics (Basel). 2023;13:1534.","journal-title":"Diagnostics (Basel)"},{"key":"1623_CR12","doi-asserted-by":"publisher","first-page":"967","DOI":"10.31083\/j.jin2004097","volume":"20","author":"C Otgonbaatar","year":"2021","unstructured":"Otgonbaatar C, Ryu J-K, Kim S, et al. Improvement of depiction of the intracranial arteries on brain CT angiography using deep learning reconstruction. J Integr Neurosci. 2021;20:967\u201376.","journal-title":"J Integr Neurosci"},{"key":"1623_CR13","doi-asserted-by":"publisher","first-page":"111","DOI":"10.1148\/radiol.2018172875","volume":"289","author":"K Brehmer","year":"2018","unstructured":"Brehmer K, Brismar TB, Morsbach F, et al. Triple Arterial Phase CT of the Liver with Radiation Dose Equivalent to That of Single Arterial Phase CT: initial Experience. Radiology. 2018;289:111\u201318.","journal-title":"Radiology"},{"key":"1623_CR14","doi-asserted-by":"publisher","first-page":"151","DOI":"10.1007\/s00330-013-2992-x","volume":"24","author":"MA Fischer","year":"2014","unstructured":"Fischer MA, Leidner B, Kartalis N, et al. Time-resolved computed tomography of the liver: retrospective, multi-phase image reconstruction derived from volumetric perfusion imaging. Eur Radiol. 2014;24:151\u201361.","journal-title":"Eur Radiol"},{"key":"1623_CR15","doi-asserted-by":"publisher","first-page":"123","DOI":"10.1007\/s00234-011-0864-0","volume":"54","author":"PWA Willems","year":"2012","unstructured":"Willems PWA, Taeshineetanakul P, Schenk B, et al. The use of 4D-CTA in the diagnostic work-up of brain arteriovenous malformations. Neuroradiology. 2012;54:123\u201331.","journal-title":"Neuroradiology"},{"key":"1623_CR16","doi-asserted-by":"publisher","first-page":"2666","DOI":"10.1016\/j.acra.2023.02.007","volume":"30","author":"Y Chen","year":"2023","unstructured":"Chen Y, Wang Y, Su T, et al. Deep learning reconstruction improves the image quality of CT angiography derived from 80-kVp cerebral CT perfusion data. Acad. Radiol. 2023;30:2666\u201373.","journal-title":"Acad. Radiol."},{"key":"1623_CR17","doi-asserted-by":"publisher","first-page":"342","DOI":"10.1016\/j.neurad.2011.11.005","volume":"39","author":"J Huang","year":"2012","unstructured":"Huang J, Degnan AJ, Liu Q, et al. Comparison of NASCET and WASID criteria for the measurement of intracranial stenosis using digital subtraction and computed tomography angiography of the middle cerebral artery. J Neuroradiol. 2012;39:342\u201345.","journal-title":"J Neuroradiol"},{"key":"1623_CR18","doi-asserted-by":"publisher","first-page":"881","DOI":"10.2214\/AJR.09.3462","volume":"194","author":"JA Christner","year":"2010","unstructured":"Christner JA, Kofler JM, McCollough CH. Estimating effective dose for CT using dose-length product compared with using organ doses: consequences of adopting International Commission on Radiological Protection publication 103 or dual-energy scanning. AJR Am J Roentgenol. 2010;194:881\u201389.","journal-title":"AJR Am J Roentgenol"},{"key":"1623_CR19","doi-asserted-by":"publisher","first-page":"110070","DOI":"10.1016\/j.ejrad.2021.110070","volume":"146","author":"M Wang","year":"2022","unstructured":"Wang M, Fan J, Shi X, et al. A deep-learning reconstruction algorithm that improves the image quality of low-tube-voltage coronary CT angiography. Eur J Radiol. 2022;146:110070.","journal-title":"Eur J Radiol"},{"key":"1623_CR20","doi-asserted-by":"publisher","first-page":"202","DOI":"10.1148\/radiol.210551","volume":"303","author":"B Jiang","year":"2022","unstructured":"Jiang B, Li N, Shi X, et al. Deep Learning Reconstruction Shows Better Lung Nodule Detection for Ultra-Low-Dose Chest CT. Radiology. 2022;303:202\u201312.","journal-title":"Radiology"},{"key":"1623_CR21","first-page":"1477","volume":"103","author":"SM Qiu","year":"2023","unstructured":"Qiu SM, Zhang H, Liu ZX, et al. The application value of deep learning image reconstruction on improving image quality and evaluating the Qanadli embolism index of dual low-dose CT pulmonary angiography. Zhonghua Yi Xue Za Zhi. 2023;103:1477\u201382.","journal-title":"Zhonghua Yi Xue Za Zhi"},{"key":"1623_CR22","doi-asserted-by":"publisher","first-page":"1536","DOI":"10.1007\/s00261-023-03845-w","volume":"48","author":"JJ Xu","year":"2023","unstructured":"Xu JJ, L\u00f6nn L, Budtz-J\u00f8rgensen E, et al. Evaluation of thin-slice abdominal DECT using deep-learning image reconstruction in 74 keV virtual monoenergetic images: an image quality comparison. Abdom Radiol (NY). 2023;48:1536\u201344.","journal-title":"Abdom Radiol (NY)"},{"key":"1623_CR23","doi-asserted-by":"publisher","first-page":"1629","DOI":"10.1007\/s00330-022-09206-3","volume":"33","author":"P Lyu","year":"2022","unstructured":"Lyu P, Liu N, Harrawood B, et al. Is it possible to use low-dose deep learning reconstruction for the detection of liver metastases on CT routinely? Eur Radiol. 2022;33:1629\u201340.","journal-title":"Eur Radiol"},{"key":"1623_CR24","doi-asserted-by":"publisher","first-page":"193","DOI":"10.1186\/s12880-024-01373-7","volume":"24","author":"L Yang","year":"2024","unstructured":"Yang L, Zhang H, Sheng J, et al. Contrast enhancement boost improves the image quality of CT angiography derived from 80-kVp cerebral CT perfusion data. BMC Med Imaging. 2024;24:193.","journal-title":"BMC Med Imaging"},{"key":"1623_CR25","doi-asserted-by":"publisher","first-page":"86","DOI":"10.1186\/s13019-024-03223-7","volume":"20","author":"K Liao","year":"2025","unstructured":"Liao K, Ye B, Li X, et al. Clinical application of third-generation dual-source CT-based dynamic imaging reconstruction for pulmonary embolism imaging. J Cardiothorac Surg. 2025;20:86.","journal-title":"J Cardiothorac Surg"},{"key":"1623_CR26","doi-asserted-by":"publisher","first-page":"806","DOI":"10.1016\/S0741-5214(02)00137-4","volume":"36","author":"PJ Nederkoorn","year":"2002","unstructured":"Nederkoorn PJ, Elgersma OEH, WPThM M, et al. Overestimation of carotid artery stenosis with magnetic resonance angiography compared with digital subtraction angiography. J Vascular Surg. 2002;36:806\u201313.","journal-title":"J Vascular Surg"}],"container-title":["BMC Medical Imaging"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12880-025-01623-2.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s12880-025-01623-2\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12880-025-01623-2.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,4,29]],"date-time":"2025-04-29T15:11:03Z","timestamp":1745939463000},"score":1,"resource":{"primary":{"URL":"https:\/\/bmcmedimaging.biomedcentral.com\/articles\/10.1186\/s12880-025-01623-2"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,4,29]]},"references-count":26,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2025,12]]}},"alternative-id":["1623"],"URL":"https:\/\/doi.org\/10.1186\/s12880-025-01623-2","relation":{},"ISSN":["1471-2342"],"issn-type":[{"value":"1471-2342","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,4,29]]},"assertion":[{"value":"11 August 2024","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"3 March 2025","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"29 April 2025","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Approval was granted by the ethics committee of Peking Union Medical College Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College (Ethics approval number: I-24PJ0479), which agreed to waive informed consent due to the retrospective nature of this study. All methods were carried out in accordance with the Declaration of Helsinki.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Not applicable.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare no competing interests.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"139"}}