{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,6]],"date-time":"2026-03-06T23:23:46Z","timestamp":1772839426500,"version":"3.50.1"},"reference-count":40,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2025,5,30]],"date-time":"2025-05-30T00:00:00Z","timestamp":1748563200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"},{"start":{"date-parts":[[2025,5,30]],"date-time":"2025-05-30T00:00:00Z","timestamp":1748563200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"}],"funder":[{"DOI":"10.13039\/501100001809","name":"the National Natural Science Foundation of China","doi-asserted-by":"crossref","award":["NSFC No. 82171934"],"award-info":[{"award-number":["NSFC No. 82171934"]}],"id":[{"id":"10.13039\/501100001809","id-type":"DOI","asserted-by":"crossref"}]},{"name":"the National High Level Hospital Clinical Research Funding","award":["2022-PUMCH-B-069"],"award-info":[{"award-number":["2022-PUMCH-B-069"]}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Med Imaging"],"DOI":"10.1186\/s12880-025-01746-6","type":"journal-article","created":{"date-parts":[[2025,5,30]],"date-time":"2025-05-30T13:12:36Z","timestamp":1748610756000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":4,"title":["Deep learning reconstruction improves computer-aided pulmonary nodule detection and measurement accuracy for ultra-low-dose chest CT"],"prefix":"10.1186","volume":"25","author":[{"given":"Jinhua","family":"Wang","sequence":"first","affiliation":[]},{"given":"Zhenchen","family":"Zhu","sequence":"additional","affiliation":[]},{"given":"Zhengsong","family":"Pan","sequence":"additional","affiliation":[]},{"given":"Weixiong","family":"Tan","sequence":"additional","affiliation":[]},{"given":"Wei","family":"Han","sequence":"additional","affiliation":[]},{"given":"Zhen","family":"Zhou","sequence":"additional","affiliation":[]},{"given":"Ge","family":"Hu","sequence":"additional","affiliation":[]},{"given":"Zhuangfei","family":"Ma","sequence":"additional","affiliation":[]},{"given":"Yinghao","family":"Xu","sequence":"additional","affiliation":[]},{"given":"Zhoumeng","family":"Ying","sequence":"additional","affiliation":[]},{"given":"Xin","family":"Sui","sequence":"additional","affiliation":[]},{"given":"Zhengyu","family":"Jin","sequence":"additional","affiliation":[]},{"given":"Lan","family":"Song","sequence":"additional","affiliation":[]},{"given":"Wei","family":"Song","sequence":"additional","affiliation":[]}],"member":"297","published-online":{"date-parts":[[2025,5,30]]},"reference":[{"key":"1746_CR1","doi-asserted-by":"crossref","unstructured":"Bray F, Laversanne M, Sung H et al. Global cancer statistics 2022: GLOBOCAN estimates of incidence and mortality worldwide for 36 cancers in 185 countries. CA Cancer J Clin 2024.","DOI":"10.3322\/caac.21834"},{"issue":"1","key":"1746_CR2","doi-asserted-by":"publisher","first-page":"228","DOI":"10.1148\/radiol.2017161659","volume":"284","author":"H MacMahon","year":"2017","unstructured":"MacMahon H, Naidich DP, Goo JM, et al. Guidelines for management of incidental pulmonary nodules detected on CT images: from the Fleischner society 2017. Radiology. 2017;284(1):228\u201343.","journal-title":"Radiology"},{"issue":"1103","key":"1746_CR3","doi-asserted-by":"publisher","first-page":"20180909","DOI":"10.1259\/bjr.20180909","volume":"92","author":"H Tang","year":"2019","unstructured":"Tang H, Liu Z, Hu Z, et al. Clinical value of a new generation adaptive statistical iterative reconstruction (ASIR-V) in the diagnosis of pulmonary nodule in low-dose chest CT. Br J Radiol. 2019;92(1103):20180909.","journal-title":"Br J Radiol"},{"key":"1746_CR4","doi-asserted-by":"publisher","first-page":"108652","DOI":"10.1016\/j.ejrad.2019.108652","volume":"119","author":"K Ye","year":"2019","unstructured":"Ye K, Zhu Q, Li M, et al. A feasibility study of pulmonary nodule detection by ultralow-dose CT with adaptive statistical iterative reconstruction-V technique. Eur J Radiol. 2019;119:108652.","journal-title":"Eur J Radiol"},{"issue":"3","key":"1746_CR5","doi-asserted-by":"publisher","first-page":"647","DOI":"10.1016\/j.radi.2023.04.016","volume":"29","author":"AE Pedersen","year":"2023","unstructured":"Pedersen AE, Kusk MW, Knudsen GH, et al. Collimation border with U-Net segmentation on chest radiographs compared to radiologists. Radiography (Lond). 2023;29(3):647\u201352.","journal-title":"Radiography (Lond)"},{"issue":"10","key":"1746_CR6","doi-asserted-by":"publisher","first-page":"1953","DOI":"10.1016\/j.ejrad.2014.06.033","volume":"83","author":"T Kubo","year":"2014","unstructured":"Kubo T, Ohno Y, Kauczor HU, et al. Radiation dose reduction in chest CT\u2013review of available options. Eur J Radiol. 2014;83(10):1953\u201361.","journal-title":"Eur J Radiol"},{"issue":"6","key":"1746_CR7","doi-asserted-by":"publisher","first-page":"442","DOI":"10.5152\/dir.2019.18539","volume":"25","author":"Y Xu","year":"2019","unstructured":"Xu Y, Zhang TT, Hu ZH, et al. Effect of iterative reconstruction techniques on image quality in low radiation dose chest CT: a Phantom study. Diagn Interv Radiol. 2019;25(6):442\u201350.","journal-title":"Diagn Interv Radiol"},{"key":"1746_CR8","doi-asserted-by":"publisher","first-page":"130","DOI":"10.1016\/j.ejrad.2017.04.006","volume":"91","author":"V Vardhanabhuti","year":"2017","unstructured":"Vardhanabhuti V, Pang CL, Tenant S, et al. Prospective intra-individual comparison of standard dose versus reduced-dose thoracic CT using hybrid and pure iterative reconstruction in a follow-up cohort of pulmonary nodules-Effect of detectability of pulmonary nodules with Lowering dose based on nodule size, type and body mass index. Eur J Radiol. 2017;91:130\u201341.","journal-title":"Eur J Radiol"},{"issue":"7","key":"1746_CR9","doi-asserted-by":"publisher","first-page":"5139","DOI":"10.1007\/s00330-020-07537-7","volume":"31","author":"JG Nam","year":"2021","unstructured":"Nam JG, Ahn C, Choi H, et al. Image quality of ultralow-dose chest CT using deep learning techniques: potential superiority of vendor-agnostic post-processing over vendor-specific techniques. Eur Radiol. 2021;31(7):5139\u201347.","journal-title":"Eur Radiol"},{"issue":"2","key":"1746_CR10","doi-asserted-by":"publisher","first-page":"339","DOI":"10.1148\/radiol.2015132766","volume":"276","author":"LL Geyer","year":"2015","unstructured":"Geyer LL, Schoepf UJ, Meinel FG, et al. State of the art: iterative CT reconstruction techniques. Radiology. 2015;276(2):339\u201357.","journal-title":"Radiology"},{"issue":"3","key":"1746_CR11","doi-asserted-by":"publisher","first-page":"491","DOI":"10.1148\/radiol.2019191422","volume":"293","author":"A Mileto","year":"2019","unstructured":"Mileto A, Guimaraes LS, McCollough CH, et al. State of the Art in abdominal CT: the limits of iterative reconstruction algorithms. Radiology. 2019;293(3):491\u2013503.","journal-title":"Radiology"},{"issue":"6","key":"1746_CR12","doi-asserted-by":"publisher","first-page":"743","DOI":"10.1038\/s41551-023-01045-x","volume":"7","author":"HY Zhou","year":"2023","unstructured":"Zhou HY, Yu Y, Wang C, et al. A transformer-based representation-learning model with unified processing of multimodal input for clinical diagnostics. Nat Biomed Eng. 2023;7(6):743\u201355.","journal-title":"Nat Biomed Eng"},{"issue":"11","key":"1746_CR13","doi-asserted-by":"publisher","first-page":"7400","DOI":"10.1109\/TPAMI.2021.3130759","volume":"44","author":"G Zhao","year":"2022","unstructured":"Zhao G, Feng Q, Chen C, et al. Diagnose like a radiologist: hybrid Neuro-Probabilistic reasoning for Attribute-Based medical image diagnosis. IEEE Trans Pattern Anal Mach Intell. 2022;44(11):7400\u201316.","journal-title":"IEEE Trans Pattern Anal Mach Intell"},{"issue":"3","key":"1746_CR14","doi-asserted-by":"publisher","first-page":"e221257","DOI":"10.1148\/radiol.221257","volume":"306","author":"LR Koetzier","year":"2023","unstructured":"Koetzier LR, Mastrodicasa D, Szczykutowicz TP, et al. Deep learning image reconstruction for CT: technical principles and clinical prospects. Radiology. 2023;306(3):e221257.","journal-title":"Radiology"},{"issue":"1","key":"1746_CR15","doi-asserted-by":"publisher","first-page":"202","DOI":"10.1148\/radiol.210551","volume":"303","author":"B Jiang","year":"2022","unstructured":"Jiang B, Li N, Shi X, et al. Deep learning reconstruction shows better lung nodule detection for Ultra-Low-Dose chest CT. Radiology. 2022;303(1):202\u201312.","journal-title":"Radiology"},{"issue":"1","key":"1746_CR16","doi-asserted-by":"publisher","first-page":"131","DOI":"10.3348\/kjr.2020.0116","volume":"22","author":"JH Kim","year":"2021","unstructured":"Kim JH, Yoon HJ, Lee E, et al. Validation of Deep-Learning image reconstruction for Low-Dose chest computed tomography scan: emphasis on image quality and noise. Korean J Radiol. 2021;22(1):131\u20138.","journal-title":"Korean J Radiol"},{"issue":"2","key":"1746_CR17","doi-asserted-by":"publisher","first-page":"1053","DOI":"10.1007\/s00330-023-10087-3","volume":"34","author":"J Wang","year":"2024","unstructured":"Wang J, Sui X, Zhao R, et al. Value of deep learning reconstruction of chest low-dose CT for image quality improvement and lung parenchyma assessment on lung window. Eur Radiol. 2024;34(2):1053\u201364.","journal-title":"Eur Radiol"},{"issue":"6","key":"1746_CR18","doi-asserted-by":"publisher","first-page":"3884","DOI":"10.1007\/s00330-020-07450-z","volume":"31","author":"LL Qi","year":"2021","unstructured":"Qi LL, Wang JW, Yang L, et al. Natural history of pathologically confirmed pulmonary subsolid nodules with deep learning-assisted nodule segmentation. Eur Radiol. 2021;31(6):3884\u201397.","journal-title":"Eur Radiol"},{"issue":"2","key":"1746_CR19","doi-asserted-by":"publisher","first-page":"438","DOI":"10.1148\/radiol.2021204433","volume":"300","author":"KV Venkadesh","year":"2021","unstructured":"Venkadesh KV, A A A Setio A, Schreuder, et al. Deep learning for malignancy risk Estimation of pulmonary nodules detected at Low-Dose screening CT. Radiology. 2021;300(2):438\u201347.","journal-title":"Radiology"},{"key":"1746_CR20","doi-asserted-by":"crossref","unstructured":"Li R, Xiao C, Huang Y et al. Deep learning applications in computed tomography images for pulmonary nodule detection and diagnosis: A review. Diagnostics (Basel) 2022;12(2).","DOI":"10.3390\/diagnostics12020298"},{"key":"1746_CR21","unstructured":"World Health Organization. Obesity: preventing and managing the global epidemic. Report of a WHO consultation. Geneva, Switzerland: World Health Organization technical report series 2000."},{"key":"1746_CR22","doi-asserted-by":"publisher","first-page":"17","DOI":"10.3352\/jeehp.2021.18.17","volume":"18","author":"H Kang","year":"2021","unstructured":"Kang H. Sample size determination and power analysis using the G*Power software. J Educ Eval Health Prof. 2021;18:17.","journal-title":"J Educ Eval Health Prof"},{"issue":"1","key":"1746_CR23","doi-asserted-by":"publisher","first-page":"13657","DOI":"10.1038\/s41598-020-70629-3","volume":"10","author":"S Cui","year":"2020","unstructured":"Cui S, Ming S, Lin Y, et al. Development and clinical application of deep learning model for lung nodules screening on CT images. Sci Rep. 2020;10(1):13657.","journal-title":"Sci Rep"},{"issue":"1144","key":"1746_CR24","doi-asserted-by":"publisher","first-page":"20220709","DOI":"10.1259\/bjr.20220709","volume":"96","author":"D Han","year":"2023","unstructured":"Han D, Cai J, Heus A, et al. Detection and size quantification of pulmonary nodules in ultralow-dose versus regular-dose CT: a comparative study in COPD patients. Br J Radiol. 2023;96(1144):20220709.","journal-title":"Br J Radiol"},{"issue":"7","key":"1746_CR25","doi-asserted-by":"publisher","first-page":"1195","DOI":"10.3348\/kjr.2018.0893","volume":"20","author":"SK Kim","year":"2019","unstructured":"Kim SK, Kim C, Lee KY, et al. Accuracy of Model-Based iterative reconstruction for CT volumetry of Part-Solid nodules and solid nodules in comparison with filtered back projection and hybrid iterative reconstruction at various dose settings: an anthropomorphic chest Phantom study. Korean J Radiol. 2019;20(7):1195\u2013206.","journal-title":"Korean J Radiol"},{"issue":"1130","key":"1746_CR26","doi-asserted-by":"publisher","first-page":"20210915","DOI":"10.1259\/bjr.20210915","volume":"95","author":"R Mikayama","year":"2022","unstructured":"Mikayama R, Shirasaka T, Kojima T, et al. Deep-learning reconstruction for ultra-low-dose lung CT: volumetric measurement accuracy and reproducibility of artificial ground-glass nodules in a Phantom study. Br J Radiol. 2022;95(1130):20210915.","journal-title":"Br J Radiol"},{"issue":"9","key":"1746_CR27","doi-asserted-by":"publisher","first-page":"1912","DOI":"10.1007\/s00330-012-2440-3","volume":"22","author":"E Quaia","year":"2012","unstructured":"Quaia E, Baratella E, Cernic S, et al. Analysis of the impact of digital tomosynthesis on the radiological investigation of patients with suspected pulmonary lesions on chest radiography. Eur Radiol. 2012;22(9):1912\u201322.","journal-title":"Eur Radiol"},{"issue":"3","key":"1746_CR28","doi-asserted-by":"publisher","first-page":"548","DOI":"10.2214\/AJR.17.19245","volume":"211","author":"C Hassani","year":"2018","unstructured":"Hassani C, Ronco A, Prosper AE, et al. Forward-Projected Model-Based iterative reconstruction in screening Low-Dose chest CT: comparison with adaptive iterative dose reduction 3D. AJR Am J Roentgenol. 2018;211(3):548\u201356.","journal-title":"AJR Am J Roentgenol"},{"issue":"1090","key":"1746_CR29","doi-asserted-by":"publisher","first-page":"20170658","DOI":"10.1259\/bjr.20170658","volume":"91","author":"M Zhang","year":"2018","unstructured":"Zhang M, Qi W, Sun Y, et al. Screening for lung cancer using sub-millisievert chest CT with iterative reconstruction algorithm: image quality and nodule detectability. Br J Radiol. 2018;91(1090):20170658.","journal-title":"Br J Radiol"},{"issue":"5","key":"1746_CR30","doi-asserted-by":"publisher","first-page":"409","DOI":"10.1016\/j.crad.2019.02.001","volume":"74","author":"AR Miller","year":"2019","unstructured":"Miller AR, Jackson D, Hui C, et al. Lung nodules are reliably detectable on ultra-low-dose CT utilising model-based iterative reconstruction with radiation equivalent to plain radiography. Clin Radiol. 2019;74(5):409. e17-409.e22.","journal-title":"Clin Radiol"},{"key":"1746_CR31","doi-asserted-by":"crossref","unstructured":"Lenfant M, Chevallier O, Comby PO et al. (2020) Deep learning versus iterative reconstruction for CT pulmonary angiography in the emergency setting: improved image quality and reduced radiation dose. Diagnostics (Basel) 10(8).","DOI":"10.3390\/diagnostics10080558"},{"issue":"12","key":"1746_CR32","doi-asserted-by":"publisher","first-page":"8140","DOI":"10.1007\/s00330-022-08870-9","volume":"32","author":"R Zhao","year":"2022","unstructured":"Zhao R, Sui X, Qin R, et al. Can deep learning improve image quality of low-dose CT: a prospective study in interstitial lung disease. Eur Radiol. 2022;32(12):8140\u201351.","journal-title":"Eur Radiol"},{"issue":"3","key":"1746_CR33","doi-asserted-by":"publisher","first-page":"564","DOI":"10.1016\/j.ejrad.2015.12.013","volume":"85","author":"X Sui","year":"2016","unstructured":"Sui X, Meinel FG, Song W, et al. Detection and size measurements of pulmonary nodules in ultra-low-dose CT with iterative reconstruction compared to low dose CT. Eur J Radiol. 2016;85(3):564\u201370.","journal-title":"Eur J Radiol"},{"issue":"3","key":"1746_CR34","doi-asserted-by":"publisher","first-page":"881","DOI":"10.1148\/radiol.2453062116","volume":"245","author":"O Honda","year":"2007","unstructured":"Honda O, Johkoh T, Sumikawa H, et al. Pulmonary nodules: 3D volumetric measurement with multidetector CT\u2013effect of intravenous contrast medium. Radiology. 2007;245(3):881\u20137.","journal-title":"Radiology"},{"issue":"4","key":"1746_CR35","doi-asserted-by":"publisher","first-page":"417","DOI":"10.1109\/TMI.2006.871547","volume":"25","author":"JM Kuhnigk","year":"2006","unstructured":"Kuhnigk JM, Dicken V, Bornemann L, et al. Morphological segmentation and partial volume analysis for volumetry of solid pulmonary lesions in thoracic CT scans. IEEE Trans Med Imaging. 2006;25(4):417\u201334.","journal-title":"IEEE Trans Med Imaging"},{"issue":"1","key":"1746_CR36","doi-asserted-by":"publisher","first-page":"276","DOI":"10.1148\/radiol.14132324","volume":"273","author":"YS Song","year":"2014","unstructured":"Song YS, Park CM, Park SJ, et al. Volume and mass doubling times of persistent pulmonary subsolid nodules detected in patients without known malignancy. Radiology. 2014;273(1):276\u201384.","journal-title":"Radiology"},{"issue":"8","key":"1746_CR37","doi-asserted-by":"publisher","first-page":"441","DOI":"10.1097\/RLI.0000000000000464","volume":"53","author":"M Silva","year":"2018","unstructured":"Silva M, Schaefer-Prokop CM, Jacobs C, et al. Detection of subsolid nodules in lung Cancer screening: complementary sensitivity of visual reading and Computer-Aided diagnosis. Invest Radiol. 2018;53(8):441\u20139.","journal-title":"Invest Radiol"},{"issue":"1","key":"1746_CR38","doi-asserted-by":"publisher","first-page":"141","DOI":"10.1186\/s12880-024-01288-3","volume":"24","author":"S Gao","year":"2024","unstructured":"Gao S, Xu Z, Kang W, et al. Artificial intelligence-driven computer aided diagnosis system provides similar diagnosis value compared with Doctors\u2019 evaluation in lung cancer screening. BMC Med Imaging. 2024;24(1):141.","journal-title":"BMC Med Imaging"},{"issue":"1","key":"1746_CR39","doi-asserted-by":"publisher","first-page":"11","DOI":"10.1016\/j.diii.2022.11.007","volume":"104","author":"C de Margerie-Mellon","year":"2023","unstructured":"de Margerie-Mellon C, Chassagnon G. Artificial intelligence: A critical review of applications for lung nodule and lung cancer. Diagn Interv Imaging. 2023;104(1):11\u20137.","journal-title":"Diagn Interv Imaging"},{"issue":"5","key":"1746_CR40","doi-asserted-by":"publisher","first-page":"2356","DOI":"10.21037\/tlcr-20-924","volume":"10","author":"A Snoeckx","year":"2021","unstructured":"Snoeckx A, Franck C, Silva M, et al. The radiologist\u2019s role in lung cancer screening. Transl Lung Cancer Res. 2021;10(5):2356\u201367.","journal-title":"Transl Lung Cancer Res"}],"container-title":["BMC Medical Imaging"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12880-025-01746-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s12880-025-01746-6\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12880-025-01746-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,5,30]],"date-time":"2025-05-30T13:12:38Z","timestamp":1748610758000},"score":1,"resource":{"primary":{"URL":"https:\/\/bmcmedimaging.biomedcentral.com\/articles\/10.1186\/s12880-025-01746-6"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,5,30]]},"references-count":40,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2025,12]]}},"alternative-id":["1746"],"URL":"https:\/\/doi.org\/10.1186\/s12880-025-01746-6","relation":{},"ISSN":["1471-2342"],"issn-type":[{"value":"1471-2342","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,5,30]]},"assertion":[{"value":"19 December 2024","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"22 May 2025","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"30 May 2025","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"This study was performed in accordance with the Declaration of Helsinki, and approved by the ethics committee of Peking Union Medical College Hospital (HS-2540). Informed consent was obtained from all patients who participated in this study. Clinical trial number: not applicable. This study was performed in accordance with the Declaration of Helsinki, and approved by the ethics committee of Peking Union Medical College Hospital (HS-2540).","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Not applicable.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"All patients who participated in this study. All the images, tables, and recordings are consented to be published.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Informed consent"}},{"value":"The authors declare no competing interests.","order":5,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}},{"value":"The Institutional Review Board of our hospital approved this prospective study (HS-2540).","order":6,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval"}}],"article-number":"200"}}