{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,27]],"date-time":"2026-02-27T04:14:48Z","timestamp":1772165688149,"version":"3.50.1"},"reference-count":34,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2025,11,11]],"date-time":"2025-11-11T00:00:00Z","timestamp":1762819200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"},{"start":{"date-parts":[[2025,11,11]],"date-time":"2025-11-11T00:00:00Z","timestamp":1762819200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"}],"funder":[{"name":"the President Foundation of Zhujiang Hospital, Southern Medical University","award":["yzjj2022qn33"],"award-info":[{"award-number":["yzjj2022qn33"]}]},{"DOI":"10.13039\/501100001809","name":"National Natural Science Foundation of China","doi-asserted-by":"crossref","award":["U21A6005"],"award-info":[{"award-number":["U21A6005"]}],"id":[{"id":"10.13039\/501100001809","id-type":"DOI","asserted-by":"crossref"}]},{"name":"the Basic and Applied Basic Research Foundation of Guangdong Province","award":["LC2016ZD028"],"award-info":[{"award-number":["LC2016ZD028"]}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Med Imaging"],"DOI":"10.1186\/s12880-025-01972-y","type":"journal-article","created":{"date-parts":[[2025,11,11]],"date-time":"2025-11-11T16:16:50Z","timestamp":1762877810000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Physics-informed sinogram completion for metal artifact reduction in non-contrast brain CT images with neurovascular coils: comparison with traditional and deep learning-based methods"],"prefix":"10.1186","volume":"25","author":[{"given":"Mingjun","family":"Lu","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yi","family":"Guo","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yuxin","family":"Li","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Xinran","family":"Yan","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jianbin","family":"Zhu","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yaoming","family":"Qu","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Andong","family":"Ma","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Zhijian","family":"Yu","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Chengyan","family":"Huang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Zhujuan","family":"Yu","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jianhua","family":"Ma","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Zhibo","family":"Wen","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2025,11,11]]},"reference":[{"issue":"8","key":"1972_CR1","doi-asserted-by":"publisher","first-page":"1002","DOI":"10.1001\/jamaneurol.2016.0609","volume":"73","author":"BP Walcott","year":"2016","unstructured":"Walcott BP, Stapleton CJ, Choudhri O, Patel AB. Flow diversion for the treatment of intracranial aneurysms. JAMA Neurol. 2016;73(8):1002\u20138.","journal-title":"JAMA Neurol"},{"issue":"9488","key":"1972_CR2","doi-asserted-by":"publisher","first-page":"809","DOI":"10.1016\/S0140-6736(05)67214-5","volume":"366","author":"AJ Molyneux","year":"2005","unstructured":"Molyneux AJ, Kerr RSC, Yu L-M, Clarke M, Sneade M, Yarnold JA, Sandercock P. International subarachnoid aneurysm trial (ISAT) of neurosurgical clipping versus endovascular coiling in 2143 patients with ruptured intracranial aneurysms: a randomised comparison of effects on survival, dependency, seizures, rebleeding, subgroups, and aneurysm occlusion. Lancet. 2005;366(9488):809\u201317.","journal-title":"Lancet"},{"issue":"3","key":"1972_CR3","doi-asserted-by":"publisher","first-page":"597","DOI":"10.1161\/01.STR.32.3.597","volume":"32","author":"SC Johnston","year":"2001","unstructured":"Johnston SC, Zhao S, Dudley RA, Berman MF, Gress DR. Treatment of unruptured cerebral aneurysms in California. Stroke. 2001;32(3):597\u2013605.","journal-title":"Stroke"},{"issue":"9","key":"1972_CR4","doi-asserted-by":"publisher","first-page":"551","DOI":"10.1097\/RLI.0000000000000170","volume":"50","author":"VM Runge","year":"2015","unstructured":"Runge VM, Aoki S, Bradley WGJ, Chang K-H, Essig M, Ma L, Ross JS, Valavanis A. Magnetic resonance imaging and computed tomography of the Brain\u201450 years of Innovation, with a focus on the future. Invest Radiol. 2015;50(9):551\u20136.","journal-title":"Invest Radiol"},{"issue":"9","key":"1972_CR5","doi-asserted-by":"publisher","first-page":"1770","DOI":"10.1007\/s003300000800","volume":"11","author":"P Parizel","year":"2001","unstructured":"Parizel P, Makkat S, Van Miert E, Van Goethem J, van den Hauwe L, De Schepper A. Intracranial hemorrhage: principles of CT and MRI interpretation. Eur Radiol. 2001;11(9):1770\u201383.","journal-title":"Eur Radiol"},{"issue":"2","key":"1972_CR6","doi-asserted-by":"publisher","first-page":"803","DOI":"10.1007\/s00330-022-09073-y","volume":"33","author":"N Schmitt","year":"2023","unstructured":"Schmitt N, Wucherpfennig L, Rotkopf LT, Sawall S, Kauczor H-U, Bendszus M, M\u00f6hlenbruch MA, Schlemmer H-P, Vollherbst DF. Metal artifacts and artifact reduction of neurovascular coils in photon-counting detector CT versus energy-integrating detector CT - in vitro comparison of a standard brain imaging protocol. Eur Radiol. 2023;33(2):803\u201311.","journal-title":"Eur Radiol"},{"issue":"6","key":"1972_CR7","doi-asserted-by":"publisher","first-page":"1840","DOI":"10.1148\/rg.2019190050","volume":"39","author":"N Ghodasara","year":"2019","unstructured":"Ghodasara N, Yi PH, Clark K, Fishman EK, Farshad M, Fritz J. Postoperative spinal CT: what the radiologist needs to know. Radiographics. 2019;39(6):1840\u201361.","journal-title":"Radiographics"},{"key":"1972_CR8","doi-asserted-by":"publisher","first-page":"5826","DOI":"10.1109\/ACCESS.2016.2608621","volume":"4","author":"L Gjesteby","year":"2016","unstructured":"Gjesteby L, Man BD, Jin Y, Paganetti H, Verburg J, Giantsoudi D, Wang G. Metal artifact reduction in CT: where are we after four decades? IEEE Access. 2016;4:5826\u201349.","journal-title":"IEEE Access"},{"issue":"10","key":"1972_CR9","doi-asserted-by":"publisher","first-page":"5482","DOI":"10.1118\/1.3484090","volume":"37","author":"E Meyer","year":"2010","unstructured":"Meyer E, Raupach R, Lell M, Schmidt B, Kachelriess M. Normalized metal artifact reduction (NMAR) in computed tomography. Med Phys. 2010;37(10):5482\u201393.","journal-title":"Med Phys"},{"issue":"4","key":"1972_CR10","doi-asserted-by":"publisher","first-page":"860","DOI":"10.2214\/AJR.16.17684","volume":"209","author":"E Shim","year":"2017","unstructured":"Shim E, Kang Y, Ahn JM, Lee E, Lee JW, Oh JH, Kang HS. Metal artifact reduction for orthopedic implants (O-MAR): usefulness in CT evaluation of reverse total shoulder arthroplasty. AJR Am J Roentgenol. 2017;209(4):860\u20136.","journal-title":"AJR Am J Roentgenol"},{"issue":"1052","key":"1972_CR11","doi-asserted-by":"publisher","first-page":"20140536","DOI":"10.1259\/bjr.20140536","volume":"88","author":"H Kwon","year":"2015","unstructured":"Kwon H, Kim KS, Chun YM, Wu HG, Carlson JNK, Park JM, Kim JI. Evaluation of a commercial orthopaedic metal artefact reduction tool in radiation therapy of patients with head and neck cancer. Br J Radiol. 2015;88(1052):20140536.","journal-title":"Br J Radiol"},{"issue":"2","key":"1972_CR12","doi-asserted-by":"publisher","first-page":"307","DOI":"10.2214\/AJR.14.12745","volume":"204","author":"S Jeong","year":"2015","unstructured":"Jeong S, Kim SH, Hwang EJ, Shin C-I, Han JK, Choi BI. Usefulness of a metal artifact reduction algorithm for orthopedic implants in abdominal CT: Phantom and clinical study results. AJR Am J Roentgenol. 2015;204(2):307\u201317.","journal-title":"AJR Am J Roentgenol"},{"issue":"1","key":"1972_CR13","doi-asserted-by":"publisher","first-page":"e11","DOI":"10.1016\/j.crad.2013.08.008","volume":"69","author":"M Kidoh","year":"2014","unstructured":"Kidoh M, Nakaura T, Nakamura S, Tokuyasu S, Osakabe H, Harada K, Yamashita Y. Reduction of dental metallic artefacts in CT: value of a newly developed algorithm for metal artefact reduction (O-MAR). Clin Radiol. 2014;69(1):e11\u20136.","journal-title":"Clin Radiol"},{"issue":"6","key":"1972_CR14","doi-asserted-by":"publisher","first-page":"1532","DOI":"10.1109\/TMI.2018.2886701","volume":"38","author":"Z Chang","year":"2019","unstructured":"Chang Z, Ye DH, Srivastava S, Thibault J-B, Sauer K, Bouman C. Prior-Guided metal artifact reduction for iterative X-Ray computed tomography. IEEE Trans Med Imaging. 2019;38(6):1532\u201342.","journal-title":"IEEE Trans Med Imaging"},{"issue":"21","key":"1972_CR15","doi-asserted-by":"publisher","first-page":"215007","DOI":"10.1088\/1361-6560\/ad00fc","volume":"68","author":"T Lyu","year":"2023","unstructured":"Lyu T, Wu Z, Ma G, Jiang C, Zhong X, Xi Y, Chen Y, Zhu W. PDS-MAR: a fine-grained projection-domain segmentation-based metal artifact reduction method for intraoperative CBCT images with guidewires. Phys Med Biol. 2023;68(21):215007.","journal-title":"Phys Med Biol"},{"key":"1972_CR16","doi-asserted-by":"crossref","unstructured":"Fan S, Li M, Huang C, Deng X, Li H. Metal artifacts correction based on a physics-informed nonlinear sinogram completion model. Phys Med Biol. 2025;70(6).","DOI":"10.1088\/1361-6560\/adbaad"},{"key":"1972_CR17","doi-asserted-by":"crossref","unstructured":"Zhu M, Zhu Q, Song Y, Guo Y, Zeng D, Bian Z, Wang Y, Ma J. Physics-informed sinogram completion for metal artifact reduction in CT imaging. Phys Med Biol. 2023;68(6).","DOI":"10.1088\/1361-6560\/acbddf"},{"issue":"10","key":"1972_CR18","doi-asserted-by":"publisher","first-page":"5482","DOI":"10.1118\/1.3484090","volume":"37","author":"E Meyer","year":"2010","unstructured":"Meyer E, Raupach R, Lell M, Schmidt B, Kachelrie\u00df M. Normalized metal artifact reduction (NMAR) in computed tomography. Med Phys. 2010;37(10):5482\u201393.","journal-title":"Med Phys"},{"issue":"9","key":"1972_CR19","doi-asserted-by":"publisher","first-page":"2803","DOI":"10.1088\/0031-9155\/57\/9\/2803","volume":"57","author":"JM Verburg","year":"2012","unstructured":"Verburg JM, Seco J. CT metal artifact reduction method correcting for beam hardening and missing projections. Phys Med Biol. 2012;57(9):2803.","journal-title":"Phys Med Biol"},{"issue":"3","key":"1972_CR20","doi-asserted-by":"publisher","first-page":"764","DOI":"10.1109\/TMI.2019.2935187","volume":"39","author":"X Tao","year":"2020","unstructured":"Tao X, Zhang H, Wang Y, Yan G, Zeng D, Chen W, Ma J. VVBP-Tensor in the FBP algorithm: its properties and application in Low-Dose CT reconstruction. IEEE Trans Med Imaging. 2020;39(3):764\u201376.","journal-title":"IEEE Trans Med Imaging"},{"issue":"7","key":"1972_CR21","doi-asserted-by":"publisher","first-page":"1778","DOI":"10.1109\/TMI.2022.3148110","volume":"41","author":"D Hu","year":"2022","unstructured":"Hu D, Zhang Y, Liu J, Luo S, Chen Y. DIOR: deep iterative Optimization-Based Residual-Learning for Limited-Angle CT reconstruction. IEEE Trans Med Imaging. 2022;41(7):1778\u201390.","journal-title":"IEEE Trans Med Imaging"},{"issue":"7","key":"1972_CR22","doi-asserted-by":"publisher","first-page":"10314","DOI":"10.1021\/acsnano.2c00168","volume":"16","author":"E Cha","year":"2022","unstructured":"Cha E, Chung H, Jang J, Lee J, Lee E, Ye JC. Low-Dose Sparse-View HAADF-STEM-EDX tomography of nanocrystals using unsupervised deep learning. ACS Nano. 2022;16(7):10314\u201326.","journal-title":"ACS Nano"},{"key":"1972_CR23","doi-asserted-by":"crossref","unstructured":"Guo Y, Wang Y, Zhu M, Zeng D, Bian Z, Tao X, Ma J. Dual domain closed-loop learning for sparse-view CT reconstruction. In: 7th International Conference on Image Formation in X-Ray Computed Tomography: 2022: SPIE; 2022: 130\u2013136.","DOI":"10.1117\/12.2646639"},{"issue":"1","key":"1972_CR24","doi-asserted-by":"publisher","first-page":"228","DOI":"10.1109\/TMI.2020.3025064","volume":"40","author":"L Yu","year":"2021","unstructured":"Yu L, Zhang Z, Li X, Xing L. Deep sinogram completion with image prior for metal artifact reduction in CT images. IEEE Trans Med Imaging. 2021;40(1):228\u201338.","journal-title":"IEEE Trans Med Imaging"},{"key":"1972_CR25","unstructured":"Lyu Y, Lin W-A, Lu J, Zhou SK. Dudonet++: encoding mask projection to reduce Ct metal artifacts. ArXiv Preprint arXiv:200100340. 2020."},{"issue":"3","key":"1972_CR26","doi-asserted-by":"publisher","first-page":"634","DOI":"10.1109\/TMI.2019.2933425","volume":"39","author":"H Liao","year":"2020","unstructured":"Liao H, Lin W-A, Zhou SK, Luo J. ADN: artifact disentanglement network for unsupervised metal artifact reduction. IEEE Trans Med Imaging. 2020;39(3):634\u201343.","journal-title":"IEEE Trans Med Imaging"},{"issue":"6","key":"1972_CR27","doi-asserted-by":"publisher","first-page":"1370","DOI":"10.1109\/TMI.2018.2823083","volume":"37","author":"Y Zhang","year":"2018","unstructured":"Zhang Y, Yu H. Convolutional neural network based metal artifact reduction in X-Ray computed tomography. IEEE Trans Med Imaging. 2018;37(6):1370\u201381.","journal-title":"IEEE Trans Med Imaging"},{"key":"1972_CR28","doi-asserted-by":"crossref","unstructured":"Lin W-A, Liao H, Peng C, Sun X, Zhang J, Luo J, Chellappa R, Zhou SK. DuDoNet: Dual domain network for CT metal artifact reduction. In: Proceedings of the IEEE\/CVF Conference on Computer Vision and Pattern Recognition. 2019;2019:10512\u201321.","DOI":"10.1109\/CVPR.2019.01076"},{"issue":"5","key":"1972_CR29","doi-asserted-by":"publisher","first-page":"1866","DOI":"10.1109\/TMI.2024.3351722","volume":"43","author":"Z Li","year":"2024","unstructured":"Li Z, Gao Q, Wu Y, Niu C, Zhang J, Wang M, Wang G, Shan H. Quad-Net: Quad-Domain network for CT metal artifact reduction. IEEE Trans Med Imaging. 2024;43(5):1866\u201379.","journal-title":"IEEE Trans Med Imaging"},{"issue":"9","key":"1972_CR30","doi-asserted-by":"publisher","first-page":"2803","DOI":"10.1088\/0031-9155\/57\/9\/2803","volume":"57","author":"JM Verburg","year":"2012","unstructured":"Verburg JM, Seco J. CT metal artifact reduction method correcting for beam hardening and missing projections. Phys Med Biol. 2012;57(9):2803\u201318.","journal-title":"Phys Med Biol"},{"issue":"1","key":"1972_CR31","doi-asserted-by":"publisher","first-page":"32","DOI":"10.1186\/s13244-020-0836-1","volume":"11","author":"Y Wei","year":"2020","unstructured":"Wei Y, Jia F, Hou P, Zha K, Pu S, Gao J. Clinical application of multi-material artifact reduction (MMAR) technique in revolution CT to reduce metallic dental artifacts. Insights Imaging. 2020;11(1):32.","journal-title":"Insights Imaging"},{"issue":"10","key":"1972_CR32","doi-asserted-by":"publisher","first-page":"5298","DOI":"10.1007\/s00330-020-06932-4","volume":"30","author":"H-D Chae","year":"2020","unstructured":"Chae H-D, Hong SH, Shin M, Choi J-Y, Yoo HJ. Combined use of virtual monochromatic images and projection-based metal artifact reduction methods in evaluation of total knee arthroplasty. Eur Radiol. 2020;30(10):5298\u2013307.","journal-title":"Eur Radiol"},{"issue":"11","key":"1972_CR33","doi-asserted-by":"publisher","first-page":"1141","DOI":"10.1007\/s00234-018-2081-6","volume":"60","author":"M Katsura","year":"2018","unstructured":"Katsura M, Sato J, Akahane M, Tajima T, Furuta T, Mori H, Abe O. Single-energy metal artifact reduction technique for reducing metallic coil artifacts on post-interventional cerebral CT and CT angiography. Neuroradiology. 2018;60(11):1141\u201350.","journal-title":"Neuroradiology"},{"issue":"4","key":"1972_CR34","doi-asserted-by":"publisher","first-page":"741","DOI":"10.1007\/s00062-018-0701-5","volume":"29","author":"A Fitsiori","year":"2019","unstructured":"Fitsiori A, Martin SP, Juillet De Saint Lager A, Gariani J, Lovblad K-O, Montet X, Vargas MI. Iterative algorithms applied to treated intracranial aneurysms. Clin Neuroradiol. 2019;29(4):741\u20139.","journal-title":"Clin Neuroradiol"}],"container-title":["BMC Medical Imaging"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12880-025-01972-y.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s12880-025-01972-y\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12880-025-01972-y.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,11,11]],"date-time":"2025-11-11T16:16:52Z","timestamp":1762877812000},"score":1,"resource":{"primary":{"URL":"https:\/\/bmcmedimaging.biomedcentral.com\/articles\/10.1186\/s12880-025-01972-y"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,11,11]]},"references-count":34,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2025,12]]}},"alternative-id":["1972"],"URL":"https:\/\/doi.org\/10.1186\/s12880-025-01972-y","relation":{"has-preprint":[{"id-type":"doi","id":"10.21203\/rs.3.rs-5648275\/v1","asserted-by":"object"}]},"ISSN":["1471-2342"],"issn-type":[{"value":"1471-2342","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,11,11]]},"assertion":[{"value":"15 December 2024","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"29 September 2025","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"11 November 2025","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The study was established, according to the ethical guidelines of the Helsinki Declaration, was approved by the Ethics Committee of the Zhujiang Hospital of Southern Medical University (approval number: 2023-KY-028-01).and waived the requirement for written informed consent from patients.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Informed consent was waived by the ethics committee due to the retrospective nature of the study.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare no competing interests.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"459"}}