{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,8]],"date-time":"2026-07-08T15:19:55Z","timestamp":1783523995336,"version":"3.55.0"},"reference-count":37,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2025,12,8]],"date-time":"2025-12-08T00:00:00Z","timestamp":1765152000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"},{"start":{"date-parts":[[2025,12,8]],"date-time":"2025-12-08T00:00:00Z","timestamp":1765152000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Med Imaging"],"DOI":"10.1186\/s12880-025-02007-2","type":"journal-article","created":{"date-parts":[[2025,12,8]],"date-time":"2025-12-08T10:15:15Z","timestamp":1765188915000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":2,"title":["Artifact reduction and diagnostic value of monoenergetic reconstructions from split-filter and dual-layer spectral detector dual-energy CT in early gastric cancer with titanium clip localization"],"prefix":"10.1186","volume":"25","author":[{"given":"Huanhuan","family":"Li","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Chao","family":"Chen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Lili","family":"Wang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Min","family":"Zhang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Zhuang","family":"Liu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2025,12,8]]},"reference":[{"key":"2007_CR1","doi-asserted-by":"crossref","unstructured":"Wichtmann HM, Laukamp KR, Manneck S, et al. Metal implants on abdominal CT: does split-filter dual-energy CT provide additional value over iterative metal artifact reduction? Abdom Radiol (NY). 2023;48(1):424\u201335.","DOI":"10.1007\/s00261-022-03682-3"},{"key":"2007_CR2","doi-asserted-by":"crossref","unstructured":"Selles M, van Osch JAC, Maas M, Boomsma MF, Wellenberg RHH. Advances in metal artifact reduction in CT images: a review of traditional and novel metal artifact reduction techniques. Eur J Radiol. 2024;170:111276.","DOI":"10.1016\/j.ejrad.2023.111276"},{"key":"2007_CR3","doi-asserted-by":"crossref","unstructured":"Katsura M, Sato J, Akahane M, Kunimatsu A, Abe O. Current and novel techniques for metal artifact reduction at CT: practical guide for radiologists. Radiographics. 2018;38(2):450\u201361.","DOI":"10.1148\/rg.2018170102"},{"key":"2007_CR4","doi-asserted-by":"crossref","unstructured":"Lewis M, Reid K, Toms AP. Reducing the effects of metal artefact using high keV monoenergetic reconstruction of dual energy CT (DECT) in hip replacements. Skeletal Radiol. 2013;42(2):275\u201382.","DOI":"10.1007\/s00256-012-1458-6"},{"issue":"9","key":"2007_CR5","doi-asserted-by":"publisher","first-page":"1287","DOI":"10.1007\/s00256-015-2155-z","volume":"44","author":"L Filograna","year":"2015","unstructured":"Filograna L, Magarelli N, Leone A, et al. Value of monoenergetic dual-energy CT (DECT) for artefact reduction from metallic orthopedic implants in post-mortem studies. Skeletal Radiol. 2015;44(9):1287\u201394.","journal-title":"Skeletal Radiol"},{"key":"2007_CR6","doi-asserted-by":"crossref","unstructured":"Komlosi P, Grady D, Smith JS, et al. Evaluation of monoenergetic imaging to reduce metallic instrumentation artifacts in computed tomography of the cervical spine. J Neurosurg Spine. 2015;22(1):34\u201338.","DOI":"10.3171\/2014.10.SPINE14463"},{"key":"2007_CR7","doi-asserted-by":"crossref","unstructured":"Wellenberg RHH, Hakvoort ET, Slump CH, Boomsma MF, Maas M, Streekstra GJ. Metal artifact reduction techniques in musculoskeletal CT-imaging. Eur J Radiol. 2018;107:60\u201369.","DOI":"10.1016\/j.ejrad.2018.08.010"},{"key":"2007_CR8","doi-asserted-by":"crossref","unstructured":"Dong Y, Shi AJ, Wu JL, et al. Metal artifact reduction using virtual monochromatic images for patients with pedicle screws implants on CT. Eur Spine J. 2016;25(6):1754\u201363.","DOI":"10.1007\/s00586-015-4053-4"},{"key":"2007_CR9","doi-asserted-by":"crossref","unstructured":"Neuhaus V, Gro\u00dfe Hokamp N, Abdullayev N, et al. Metal artifact reduction by dual-layer computed tomography using virtual monoenergetic images. Eur J Radiol. 2017;93:143\u201348.","DOI":"10.1016\/j.ejrad.2017.05.013"},{"issue":"8","key":"2007_CR10","doi-asserted-by":"publisher","first-page":"4228","DOI":"10.1007\/s00330-018-5928-7","volume":"29","author":"KR Laukamp","year":"2019","unstructured":"Laukamp KR, Zopfs D, Lennartz S, et al. Metal artifacts in patients with large dental implants and bridges: combination of metal artifact reduction algorithms and virtual monoenergetic images provides an approach to handle even strongest artifacts. Eur Radiol. 2019;29(8):4228\u201338.","journal-title":"Eur Radiol"},{"key":"2007_CR11","doi-asserted-by":"publisher","first-page":"14","DOI":"10.1016\/j.ejrad.2018.12.008","volume":"111","author":"V Neuhaus","year":"2019","unstructured":"Neuhaus V, Grosse Hokamp N, Zopfs D, et al. Reducing artifacts from total hip replacements in dual layer detector CT: combination of virtual monoenergetic images and orthopedic metal artifact reduction. Eur J Radiol. 2019;111:14\u201320.","journal-title":"Eur J Radiol"},{"key":"2007_CR12","doi-asserted-by":"publisher","first-page":"109254","DOI":"10.1016\/j.ejrad.2020.109254","volume":"132","author":"J Kim","year":"2020","unstructured":"Kim J, Park C, Jeong HS, et al. The optimal combination of monochromatic and metal artifact Reconstruction dual-energy CT to evaluate total knee replacement arthroplasty. Eur J Radiol. 2020;132:109254.","journal-title":"Eur J Radiol"},{"key":"2007_CR13","doi-asserted-by":"publisher","first-page":"405","DOI":"10.1186\/s40064-016-2006-y","volume":"5","author":"MF Boomsma","year":"2016","unstructured":"Boomsma MF, Warringa N, Edens MA, et al. Quantitative analysis of orthopedic metal artefact reduction in 64-slice computed tomography scans in large head metal-on-metal total hip replacement, a phantom study. Springerplus. 2016;5:405.","journal-title":"Springerplus"},{"issue":"1","key":"2007_CR14","doi-asserted-by":"publisher","first-page":"171","DOI":"10.1186\/s13244-021-01111-5","volume":"12","author":"M Selles","year":"2021","unstructured":"Selles M, Stuivenberg VH, Wellenberg RHH, et al. Quantitative analysis of metal artifact reduction in total hip arthroplasty using virtual monochromatic imaging and orthopedic metal artifact reduction, a phantom study. Insights Imag. 2021;12(1):171.","journal-title":"Insights Imag"},{"key":"2007_CR15","doi-asserted-by":"publisher","first-page":"9","DOI":"10.1016\/j.ejmp.2019.11.006","volume":"69","author":"ET Hakvoort","year":"2020","unstructured":"Hakvoort ET, Wellenberg RHH, Streekstra GJ. Quantifying near metal visibility using dual energy computed tomography and iterative metal artifact reduction in a fracture phantom. Phys Med. 2020;69:9\u201318.","journal-title":"Phys Med"},{"issue":"2","key":"2007_CR16","doi-asserted-by":"publisher","first-page":"152","DOI":"10.4103\/jmp.jmp_121_21","volume":"47","author":"L Ceccarelli","year":"2022","unstructured":"Ceccarelli L, Vara G, Ponti F, Miceli M, Golfieri R, Facchini G. Reduction of metal artifacts caused by titanium peduncular screws in the spine by Means of monoenergetic images and the metal artifact reduction software in dual-energy computed tomography. J Med Phys. 2022;47(2):152\u201358.","journal-title":"J Med Phys"},{"issue":"11","key":"2007_CR17","first-page":"864","volume":"36","author":"HY Ni","year":"2021","unstructured":"Ni HY, Jia WQ, Wang XM, et al. The impact of preoperative tumor localization with titanium clips on the surgical approach for laparoscopic gastric cancer. Chin J Gener Surg. 2021;36(11):864\u201366.","journal-title":"Chin J Gener Surg"},{"issue":"10","key":"2007_CR18","first-page":"757","volume":"57","author":"ZY Qian","year":"2019","unstructured":"Qian ZY, Wen Y, Lou GC, et al. Preliminary application of titanium clip localization combined with CT three-dimensional reconstruction in evaluating surgical margins for laparoscopic surgery of gastric cancer. Chin J Surg. 2019;57(10):757\u201362.","journal-title":"Chin J Surg"},{"issue":"6","key":"2007_CR19","doi-asserted-by":"publisher","first-page":"e140","DOI":"10.1016\/j.acra.2019.09.004","volume":"27","author":"JJ Liu","year":"2020","unstructured":"Liu JJ, Liu W, Jin ZY, et al. Improved visualization of gastric cancer and increased diagnostic performance in lesion depiction and depth identification using monoenergetic reconstructions from a novel dual-layer spectral detector CT. Acad Radiol. 2020;27(6):e140\u201347.","journal-title":"Acad Radiol"},{"issue":"4","key":"2007_CR20","doi-asserted-by":"publisher","first-page":"745","DOI":"10.1109\/TUFFC.2019.2956855","volume":"67","author":"A Rodriguez-Molares","year":"2020","unstructured":"Rodriguez-Molares A, Rindal OMH, D\u2019hooge J, et al. The generalized contrast-to-noise ratio: a formal definition for lesion detectability. IEEE Trans Ultrason Ferroelectr Freq Control. 2020;67(4):745\u201359.","journal-title":"IEEE Trans Ultrason Ferroelectr Freq Control"},{"key":"2007_CR21","volume-title":"The 8th edition of the AJCC cancer staging manual","author":"MB Amin","year":"2017","unstructured":"Amin MB, Edge S, Greene F, et al. The 8th edition of the AJCC cancer staging manual. New York: Springer; 2017."},{"issue":"3","key":"2007_CR22","doi-asserted-by":"publisher","first-page":"654","DOI":"10.1007\/s00330-011-2283-3","volume":"22","author":"JW Kim","year":"2012","unstructured":"Kim JW, Shin SS, Heo SH, et al. Diagnostic performance of 64-section CT using CT gastrography in preoperative T staging of gastric cancer according to 7th edition of AJCC cancer staging manual. Eur Radiol. 2012;22(3):654\u201362.","journal-title":"Eur Radiol"},{"issue":"3","key":"2007_CR23","doi-asserted-by":"publisher","first-page":"805","DOI":"10.1148\/radiol.10091313","volume":"255","author":"IJ Lee","year":"2010","unstructured":"Lee IJ, Lee JM, Kim SH, et al. Diagnostic performance of 64-channel multidetector CT in the evaluation of gastric cancer: differentiation of mucosal cancer (T1a) from submucosal involvement (T1b and T2). Radiology. 2010;255(3):805\u201314.","journal-title":"Radiology"},{"issue":"11","key":"2007_CR24","doi-asserted-by":"publisher","first-page":"1141","DOI":"10.1007\/s00234-018-2081-6","volume":"60","author":"M Katsura","year":"2018","unstructured":"Katsura M, Sato J, Akahane M, et al. Single-energy metal artifact reduction technique for reducing metallic coil artifacts on post-interventional cerebral CT and CT angiography. Neuroradiology. 2018;60(11):1141\u201350.","journal-title":"Neuroradiology"},{"key":"2007_CR25","first-page":"117 p","volume-title":"Step-by-step examples of Data analysis and statistical graphs in clinical researches","author":"D-Y Zhou","year":"2011","unstructured":"Zhou D-Y, Zhuang C, Jiao Z-S, Ma J. Step-by-step examples of data analysis and statistical graphs in clinical researches. Beijing: Military Med Sci Press; 2011. 117 p."},{"issue":"1","key":"2007_CR26","doi-asserted-by":"publisher","first-page":"51","DOI":"10.1007\/s00256-020-03528-3","volume":"50","author":"P Mohammadinejad","year":"2021","unstructured":"Mohammadinejad P, Baffour FI, Adkins MC, et al. Benefits of iterative metal artifact reduction and dual-energy CT towards mitigating artifact in the setting of total shoulder prostheses. Skeletal Radiol. 2021;50(1):51\u201358.","journal-title":"Skeletal Radiol"},{"issue":"12","key":"2007_CR27","doi-asserted-by":"publisher","first-page":"728","DOI":"10.1097\/RLI.0000000000000497","volume":"53","author":"I Khodarahmi","year":"2018","unstructured":"Khodarahmi I, Haroun RR, Lee M, et al. Metal artifact reduction computed tomography of arthroplasty implants: effects of combined modeled iterative reconstruction and dual-energy virtual monoenergetic extrapolation at higher photon energies. Invest Radiol. 2018;53(12):728\u201335.","journal-title":"Invest Radiol"},{"issue":"2","key":"2007_CR28","doi-asserted-by":"publisher","first-page":"195","DOI":"10.1007\/s00256-017-2776-5","volume":"47","author":"Gro\u00dfe Hokamp","year":"2018","unstructured":"Gro\u00dfe Hokamp, Neuhaus V, Abdullayev N, et al. Reduction of artifacts caused by orthopedic hardware in the spine in spectral detector CT examinations using virtual monoenergetic image reconstructions and metal-artifact-reduction algorithms. Skeletal Radiol. 2018;47(2):195\u2013201.","journal-title":"Skeletal Radiol"},{"issue":"10","key":"2007_CR29","doi-asserted-by":"publisher","first-page":"1421","DOI":"10.1177\/0284185120903446","volume":"61","author":"FW Feldhaus","year":"2020","unstructured":"Feldhaus FW, B\u00f6ning G, Kahn J, et al. Improvement of image quality and diagnostic confidence using smart MAR - a projection-based CT protocol in patients with orthopedic metallic implants in hip, spine, and shoulder. Acta Radiol. 2020;61(10):1421\u201330.","journal-title":"Acta Radiol"},{"key":"2007_CR30","doi-asserted-by":"crossref","unstructured":"Pennig L, Zopfs D, Gertz R, et al. Reduction of CT artifacts from cardiac implantable electronic devices using a combination of virtual monoenergetic images and post-processing algorithms. Eur Radiol. 2021;31(9):7151\u201361.","DOI":"10.1007\/s00330-021-07746-8"},{"key":"2007_CR31","doi-asserted-by":"crossref","unstructured":"Yue D, Fan Rong C, Ning C, et al. Reduction of metal artifacts from unilateral hip arthroplasty on dual-energy CT with metal artifact reduction software. Acta Radiol. 2018;59(7):853\u201360.","DOI":"10.1177\/0284185117731475"},{"key":"2007_CR32","doi-asserted-by":"crossref","unstructured":"Conti D, Baruffaldi F, Erani P, Festa A, Durante S, Santoro M. Dual-energy computed tomography applications to reduce metal artifacts in hip prostheses: a phantom study. Diagn (Basel). 2022;13(1):50.","DOI":"10.3390\/diagnostics13010050"},{"key":"2007_CR33","doi-asserted-by":"crossref","unstructured":"Bolstad K, Flatab\u00f8 S, Aadnevik D, Dalehaug I, Vetti N. Metal artifact reduction in CT, a phantom study: subjective and objective evaluation of four commercial metal artifact reduction algorithms when used on three different orthopedic metal implants. Acta Radiol. 2018;59(9):1110\u201318.","DOI":"10.1177\/0284185117751278"},{"key":"2007_CR34","doi-asserted-by":"crossref","unstructured":"Shi C, Zhang H, Yan J, et al. Decreased stage migration rate of early gastric cancer with a new reconstruction algorithm using dual-energy CT images: a preliminary study. Eur Radiol. 2017;27(2):671\u201380.","DOI":"10.1007\/s00330-016-4442-z"},{"key":"2007_CR35","doi-asserted-by":"crossref","unstructured":"Gro\u00dfe Hokamp, Laukamp KR, Lennartz S, et al. Artifact reduction from dental implants using virtual monoenergetic reconstructions from novel spectral detector CT. Eur J Radiol. 2018;104:136\u201342.","DOI":"10.1016\/j.ejrad.2018.04.018"},{"key":"2007_CR36","doi-asserted-by":"crossref","unstructured":"Risch F, Decker JA, Popp D, et al. Artifact reduction from dental material in photon-counting detector computed tomography data sets based on high-keV monoenergetic imaging and iterative metal artifact reduction reconstructions-can we combine the best of two worlds? Invest Radiol. 2023;58(9):691\u201396.","DOI":"10.1097\/RLI.0000000000000967"},{"key":"2007_CR37","doi-asserted-by":"crossref","unstructured":"Dillinger D, Overhoff D, Froelich MF, et al. Photon-counting detector CT virtual monoenergetic images in cervical trauma imaging-optimization of dental metal artifacts and image quality. Diagn (Basel). 2024;14(6):626.","DOI":"10.3390\/diagnostics14060626"}],"container-title":["BMC Medical Imaging"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12880-025-02007-2.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s12880-025-02007-2\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12880-025-02007-2.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,12,8]],"date-time":"2025-12-08T10:15:22Z","timestamp":1765188922000},"score":1,"resource":{"primary":{"URL":"https:\/\/bmcmedimaging.biomedcentral.com\/articles\/10.1186\/s12880-025-02007-2"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,12,8]]},"references-count":37,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2025,12]]}},"alternative-id":["2007"],"URL":"https:\/\/doi.org\/10.1186\/s12880-025-02007-2","relation":{},"ISSN":["1471-2342"],"issn-type":[{"value":"1471-2342","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,12,8]]},"assertion":[{"value":"4 May 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"17 October 2025","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"8 December 2025","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The study was conducted in accordance with the Declaration of Helsinki (as revised in 2013) and was approved by the Ethics Committee of the Institutional Review Board of Fudan University Shanghai Cancer Center (No.1612167-18).","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Informed consent for this retrospective analysis was waived by the Medical Ethics Committee of Fudan University Shanghai Cancer Center.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Human ethics and consent to participate"}},{"value":"Not applicable.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare no competing interests.","order":5,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"502"}}