{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,27]],"date-time":"2026-02-27T04:14:49Z","timestamp":1772165689373,"version":"3.50.1"},"reference-count":20,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2026,1,20]],"date-time":"2026-01-20T00:00:00Z","timestamp":1768867200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"},{"start":{"date-parts":[[2026,2,13]],"date-time":"2026-02-13T00:00:00Z","timestamp":1770940800000},"content-version":"vor","delay-in-days":24,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Med Imaging"],"DOI":"10.1186\/s12880-026-02162-0","type":"journal-article","created":{"date-parts":[[2026,1,20]],"date-time":"2026-01-20T17:05:12Z","timestamp":1768928712000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Impact of slice thickness on CACS calculation with virtual non-contrast in photon-counting CT"],"prefix":"10.1186","volume":"26","author":[{"given":"Qiuju","family":"Hu","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Huixin","family":"Zhang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Bangjun","family":"Guo","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Dongsheng","family":"Jin","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Meirong","family":"Sun","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jiliang","family":"Chen","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Song","family":"Luo","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yane","family":"Zhao","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Guang-ming","family":"Lu","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2026,1,20]]},"reference":[{"issue":"16","key":"2162_CR1","doi-asserted-by":"publisher","first-page":"1557","DOI":"10.1016\/j.jacc.2024.01.039","volume":"83","author":"S Parsa","year":"2024","unstructured":"Parsa S, Saleh A, Raygor V, et al. Measurement and application of incidentally detected coronary calcium: JACC review topic of the week. J Am Coll Cardiol. 2024;83(16):1557\u201367. https:\/\/doi.org\/10.1016\/j.jacc.2024.01.039.","journal-title":"J Am Coll Cardiol"},{"issue":"1","key":"2162_CR2","doi-asserted-by":"publisher","first-page":"98","DOI":"10.1016\/j.jcmg.2022.06.018","volume":"16","author":"IS Golub","year":"2023","unstructured":"Golub IS, Termeie OG, Kristo S, et al. Major global coronary artery calcium guidelines. JACC Cardiovasc Imaging. 2023;16(1):98\u2013117. https:\/\/doi.org\/10.1016\/j.jcmg.2022.06.018.","journal-title":"JACC Cardiovasc Imaging"},{"key":"2162_CR3","doi-asserted-by":"publisher","unstructured":"Arnett DK, Blumenthal RS, Albert MA et al. (2019) 2019 ACC\/ AHA guideline on the primary prevention of cardiovascular disease: a report of the American College of Cardiology\/American Heart Association Task Force on clinical practice guidelines. Circulation, 2019;140:e596-e646. https:\/\/doi.org\/10.1161\/CIR.0000000000000678.","DOI":"10.1161\/CIR.0000000000000678"},{"issue":"1","key":"2162_CR4","doi-asserted-by":"publisher","first-page":"2186317","DOI":"10.1080\/10641963.2023.2186317","volume":"45","author":"Q Jiang","year":"2023","unstructured":"Jiang Q, Zhang N, Zhang H, et al. Impact of off-hour admission on the maces of patients with acute myocardial infarction. Clin Exp Hypertens. 2023;45(1):2186317. https:\/\/doi.org\/10.1080\/10641963.2023.2186317.","journal-title":"Clin Exp Hypertens"},{"issue":"8","key":"2162_CR5","doi-asserted-by":"publisher","first-page":"6193","DOI":"10.1007\/s00330-020-07677-w","volume":"31","author":"FG Gassert","year":"2021","unstructured":"Gassert FG, Schacky CE, M\u00fcller-Leisse C, et al. Calcium scoring using virtual non-contrast images from a dual-layer spectral detector CT: comparison to true non-contrast data and evaluation of proportionality factor in a large patient collective. Eur Radiol. 2021;31(8):6193\u20139. https:\/\/doi.org\/10.1007\/s00330-020-07677-w.","journal-title":"Eur Radiol"},{"key":"2162_CR6","doi-asserted-by":"publisher","first-page":"1114058","DOI":"10.3389\/fcvm.2023.1114058","volume":"10","author":"P Yang","year":"2023","unstructured":"Yang P, Zhao R, Deng W, et al. Feasibility and accuracy of coronary artery calcium score on virtual non-contrast images derived from a dual-layer spectral detector CT: A retrospective multicenter study. Front Cardiovasc Med. 2023;10:1114058. https:\/\/doi.org\/10.3389\/fcvm.2023.1114058. Published 2023 Mar 2.","journal-title":"Front Cardiovasc Med"},{"key":"2162_CR7","doi-asserted-by":"publisher","first-page":"110681","DOI":"10.1016\/j.ejrad.2022.110681","volume":"159","author":"IL Langenbach","year":"2023","unstructured":"Langenbach IL, Wienemann H, Klein K, et al. Coronary calcium scoring using virtual non-contrast reconstructions on a dual-layer spectral CT system: feasibility in the clinical practice. Eur J Radiol. 2023;159:110681. https:\/\/doi.org\/10.1016\/j.ejrad.2022.110681.","journal-title":"Eur J Radiol"},{"issue":"3","key":"2162_CR8","doi-asserted-by":"publisher","first-page":"218","DOI":"10.1016\/j.jcct.2020.12.005","volume":"15","author":"V Sandfort","year":"2021","unstructured":"Sandfort V, Persson M, Pourmorteza A, et al. Spectral photon-counting CT in cardiovascular imaging. J Cardiovasc Comput Tomogr. 2021;15(3):218\u201325. https:\/\/doi.org\/10.1016\/j.jcct.2020.12.005.","journal-title":"J Cardiovasc Comput Tomogr"},{"issue":"8","key":"2162_CR9","doi-asserted-by":"publisher","first-page":"536","DOI":"10.1097\/RLI.0000000000000868","volume":"57","author":"T Emrich","year":"2022","unstructured":"Emrich T, Aquino G, Schoepf UJ, et al. Coronary computed tomography Angiography-Based calcium scoring: in vitro and in vivo validation of a novel virtual noniodine reconstruction algorithm on a Clinical, First-Generation Dual-Source photon Counting-Detector system. Invest Radiol. 2022;57(8):536\u201343. https:\/\/doi.org\/10.1097\/RLI.0000000000000868.","journal-title":"Invest Radiol"},{"issue":"9","key":"2162_CR10","doi-asserted-by":"publisher","first-page":"673","DOI":"10.1097\/RLI.0000000000000959","volume":"58","author":"N Fink","year":"2023","unstructured":"Fink N, Zsarnoczay E, Schoepf UJ, et al. Photon counting detector CT-Based virtual noniodine reconstruction algorithm for in vitro and in vivo coronary artery calcium scoring: impact of virtual monoenergetic and quantum iterative reconstructions. Invest Radiol. 2023;58(9):673\u201380. https:\/\/doi.org\/10.1097\/RLI.0000000000000959.","journal-title":"Invest Radiol"},{"issue":"5","key":"2162_CR11","doi-asserted-by":"publisher","first-page":"342","DOI":"10.1016\/j.jcct.2014.07.003","volume":"8","author":"J Leipsic","year":"2014","unstructured":"Leipsic J, Abbara S, Achenbach S, et al. SCCT guidelines for the interpretation and reporting of coronary CT angiography: a report of the society of cardiovascular computed tomography guidelines committee. J Cardiovasc Comput Tomogr. 2014;8(5):342\u201358. https:\/\/doi.org\/10.1016\/j.jcct.2014.07.003.","journal-title":"J Cardiovasc Comput Tomogr"},{"key":"2162_CR12","doi-asserted-by":"publisher","DOI":"10.1016\/j.jacr.2022.09.012","author":"RC Cury","year":"2022","unstructured":"Cury RC, Leipsic J, Abbara S, et al. CAD-RADS\u2122 2.0\u20132022 Coronary Artery Disease - Reporting and Data System. An expert consensus document of the Society of Cardiovascular Computed Tomography (SCCT), the American College of Cardiology (ACC), the American College of Radiology (ACR), and the North American Society of Cardiovascular Imaging (NASCI). J Am Coll Radiol. 2022;19(11):1185\u2013212. https:\/\/doi.org\/10.1016\/j.jacr.2022.09.012."},{"issue":"9","key":"2162_CR13","doi-asserted-by":"publisher","first-page":"6621","DOI":"10.1007\/s00330-021-07780-6","volume":"31","author":"M Sandstedt","year":"2021","unstructured":"Sandstedt M, Marsh J Jr, Rajendran K, et al. Improved coronary calcification quantification using photon-counting-detector CT: an ex vivo study in cadaveric specimens. Eur Radiol. 2021;31(9):6621\u201330. https:\/\/doi.org\/10.1007\/s00330-021-07780-6.","journal-title":"Eur Radiol"},{"issue":"7","key":"2162_CR14","doi-asserted-by":"publisher","first-page":"1613","DOI":"10.1007\/s10554-022-02540-z","volume":"38","author":"NR Van der Werf","year":"2022","unstructured":"Van der Werf NR, Booij R, Greuter MJW, et al. Reproducibility of coronary artery calcium quantification on dual-source CT and dual-source photon-counting CT: a dynamic Phantom study. Int J Cardiovasc Imaging. 2022;38(7):1613\u20139. https:\/\/doi.org\/10.1007\/s10554-022-02540-z.","journal-title":"Int J Cardiovasc Imaging"},{"issue":"4","key":"2162_CR15","doi-asserted-by":"publisher","first-page":"905","DOI":"10.1007\/s10554-021-02466-y","volume":"38","author":"V Mergen","year":"2022","unstructured":"Mergen V, Higashigaito K, Allmendinger T, et al. Tube voltage-independent coronary calcium scoring on a first-generation dual-source photon-counting CT proof-of-principle Phantom study. Int J Cardiovasc Imaging. 2022;38(4):905\u201312. https:\/\/doi.org\/10.1007\/s10554-021-02466-y.","journal-title":"Int J Cardiovasc Imaging"},{"issue":"5","key":"2162_CR16","doi-asserted-by":"publisher","first-page":"1145","DOI":"10.1007\/s10554-021-02494-8","volume":"38","author":"S Skoog","year":"2022","unstructured":"Skoog S, Henriksson L, Gustafsson H, Sandstedt M, Elvelind S, Persson A. Comparison of the Agatston score acquired with photon-counting detector CT and energy-integrating detector CT: ex vivo study of cadaveric hearts. Int J Cardiovasc Imaging. 2022;38(5):1145\u201355. https:\/\/doi.org\/10.1007\/s10554-021-02494-8.","journal-title":"Int J Cardiovasc Imaging"},{"issue":"1","key":"2162_CR17","doi-asserted-by":"publisher","first-page":"13","DOI":"10.1097\/RLI.0000000000000808","volume":"57","author":"GD van Praagh","year":"2022","unstructured":"van Praagh GD, Wang J, van der Werf NR, et al. Coronary artery calcium scoring: toward a new standard. Invest Radiol. 2022;57(1):13\u201322. https:\/\/doi.org\/10.1097\/RLI.0000000000000808.","journal-title":"Invest Radiol"},{"issue":"2","key":"2162_CR18","doi-asserted-by":"publisher","first-page":"520","DOI":"10.1148\/radiol.2292021305","volume":"229","author":"R Vliegenthart","year":"2003","unstructured":"Vliegenthart R, Song B, Hofman A, et al. Coronary calcification at electron-beam CT: effect of section thickness on calcium scoring in vitro and in vivo. Radiology. 2003;229(2):520\u20135. https:\/\/doi.org\/10.1148\/radiol.2292021305.","journal-title":"Radiology"},{"issue":"11","key":"2162_CR19","doi-asserted-by":"publisher","first-page":"695","DOI":"10.1097\/01.rli.0000179523.07907.a6","volume":"40","author":"G M\u00fchlenbruch","year":"2005","unstructured":"M\u00fchlenbruch G, Thomas C, Wildberger JE, et al. Effect of varying slice thickness on coronary calcium scoring with multislice computed tomography in vitro and in vivo. Invest Radiol. 2005;40(11):695\u20139. https:\/\/doi.org\/10.1097\/01.rli.0000179523.07907.a6.","journal-title":"Invest Radiol"},{"issue":"7","key":"2162_CR20","doi-asserted-by":"publisher","first-page":"4257","DOI":"10.21037\/aims-22-835","volume":"13","author":"SY Kim","year":"2023","unstructured":"Kim SY, Suh YJ, Lee HJ, et al. Influence of computed tomography slice thickness on deep learning-based, automatic coronary artery calcium scoring software performance. Quant Imaging Med Surg. 2023;13(7):4257\u201367. https:\/\/doi.org\/10.21037\/aims-22-835.","journal-title":"Quant Imaging Med Surg"}],"container-title":["BMC Medical Imaging"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s12880-026-02162-0","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12880-026-02162-0.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12880-026-02162-0.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,2,13]],"date-time":"2026-02-13T11:31:34Z","timestamp":1770982294000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1186\/s12880-026-02162-0"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,1,20]]},"references-count":20,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2026,12]]}},"alternative-id":["2162"],"URL":"https:\/\/doi.org\/10.1186\/s12880-026-02162-0","relation":{"references":[{"id-type":"doi","id":"10.1016\/j.jacr.2022.09.012","asserted-by":"subject"}],"has-preprint":[{"id-type":"doi","id":"10.21203\/rs.3.rs-6843811\/v1","asserted-by":"object"}]},"ISSN":["1471-2342"],"issn-type":[{"value":"1471-2342","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,1,20]]},"assertion":[{"value":"7 June 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"8 January 2026","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"20 January 2026","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"This study was approved by the Ethics Committee of Geriatric Hospital of Nanjing Medical University(YJ-2024-044-1) in accordance with the Declaration of Helsinki.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical approval"}},{"value":"Not applicable.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent to participate"}},{"value":"Not applicable.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare no competing interests.","order":5,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"89"}}