{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,26]],"date-time":"2026-05-26T13:03:27Z","timestamp":1779800607198,"version":"3.53.1"},"reference-count":33,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2026,4,16]],"date-time":"2026-04-16T00:00:00Z","timestamp":1776297600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"},{"start":{"date-parts":[[2026,5,26]],"date-time":"2026-05-26T00:00:00Z","timestamp":1779753600000},"content-version":"vor","delay-in-days":40,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"}],"funder":[{"DOI":"10.13039\/501100001809","name":"National Natural Science Foundation of China","doi-asserted-by":"crossref","award":["82471931"],"award-info":[{"award-number":["82471931"]}],"id":[{"id":"10.13039\/501100001809","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Med Imaging"],"DOI":"10.1186\/s12880-026-02339-7","type":"journal-article","created":{"date-parts":[[2026,4,16]],"date-time":"2026-04-16T08:39:46Z","timestamp":1776328786000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Infant and toddler\u2019s preoperative chest imaging on photon-counting detector CT: a paired-sample comparison with energy-integrating detector CT on image quality and radiation dose"],"prefix":"10.1186","volume":"26","author":[{"given":"Xiang-Yu","family":"Liu","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Wei","family":"Zhou","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ruo-Yang","family":"Shi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Wei-Hui","family":"Xie","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Wei-Dong","family":"Qiao","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tang-Xu","family":"Sun","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sheng-Yang","family":"Xu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ji","family":"Wang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Lian-Ming","family":"Wu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,4,16]]},"reference":[{"key":"2339_CR1","doi-asserted-by":"publisher","unstructured":"Smith-Bindman R, Miglioretti DL, Johnson E, Lee C, Feigelson HS, Flynn M, et al. Use of Diagnostic Imaging Studies and Associated Radiation Exposure for Patients Enrolled in Large Integrated Health Care Systems, 1996\u20132010. JAMA. 2012;307. https:\/\/doi.org\/10.1001\/jama.2012.5960.","DOI":"10.1001\/jama.2012.5960"},{"key":"2339_CR2","doi-asserted-by":"publisher","first-page":"227","DOI":"10.1007\/s10140-007-0618-9","volume":"14","author":"J Broder","year":"2007","unstructured":"Broder J, Fordham LA, Warshauer DM. Increasing utilization of computed tomography in the pediatric emergency department, 2000\u20132006. Emerg Radiol. 2007;14:227\u201332. https:\/\/doi.org\/10.1007\/s10140-007-0618-9.","journal-title":"Emerg Radiol"},{"key":"2339_CR3","doi-asserted-by":"publisher","first-page":"520","DOI":"10.1148\/radiol.2532082010","volume":"253","author":"FA Mettler","year":"2009","unstructured":"Mettler FA, Bhargavan M, Faulkner K, Gilley DB, Gray JE, Ibbott GS, et al. Radiologic and Nuclear Medicine Studies in the United States and Worldwide: Frequency, Radiation Dose, and Comparison with Other Radiation Sources\u20141950\u20132007. Radiology. 2009;253:520\u201331. https:\/\/doi.org\/10.1148\/radiol.2532082010.","journal-title":"Radiology"},{"key":"2339_CR4","doi-asserted-by":"publisher","first-page":"1491","DOI":"10.1377\/hlthaff.27.6.1491","volume":"27","author":"R Smith-Bindman","year":"2008","unstructured":"Smith-Bindman R, Miglioretti DL, Larson EB. Rising Use Of Diagnostic Medical Imaging In A Large Integrated Health System. Health Aff. 2008;27:1491\u2013502. https:\/\/doi.org\/10.1377\/hlthaff.27.6.1491.","journal-title":"Health Aff"},{"key":"2339_CR5","doi-asserted-by":"publisher","first-page":"460","DOI":"10.1097\/MLR.0b013e31815dc5ae","volume":"46","author":"JM Mitchell","year":"2008","unstructured":"Mitchell JM. Utilization Trends for Advanced Imaging Procedures: Evidence From Individuals With Private Insurance Coverage in California. Med Care. 2008;46:460\u20136. https:\/\/doi.org\/10.1097\/MLR.0b013e31815dc5ae.","journal-title":"Med Care"},{"key":"2339_CR6","doi-asserted-by":"publisher","first-page":"2277","DOI":"10.1056\/NEJMra072149","volume":"357","author":"DJ Brenner","year":"2007","unstructured":"Brenner DJ, Hall EJ. Computed Tomography \u2014 An Increasing Source of Radiation Exposure. N Engl J Med. 2007;357:2277\u201384. https:\/\/doi.org\/10.1056\/NEJMra072149.","journal-title":"N Engl J Med"},{"key":"2339_CR7","doi-asserted-by":"publisher","first-page":"289","DOI":"10.2214\/ajr.176.2.1760289","volume":"176","author":"DJ Brenner","year":"2001","unstructured":"Brenner DJ, Elliston CD, Hall EJ, Berdon WE. Estimated Risks of Radiation-Induced Fatal Cancer from Pediatric CT. Am J Roentgenol. 2001;176:289\u201396. https:\/\/doi.org\/10.2214\/ajr.176.2.1760289.","journal-title":"Am J Roentgenol"},{"key":"2339_CR8","unstructured":"Chodick G, Ronckers CM, Mpa VS, Ron E. Excess Lifetime Cancer Mortality Risk Attributable to Radiation Exposure from Computed Tomography Examinations in Children."},{"key":"2339_CR9","doi-asserted-by":"publisher","first-page":"2069","DOI":"10.1007\/s00247-023-05699-2","volume":"53","author":"W Zhou","year":"2023","unstructured":"Zhou W, Malave MN, Maloney JA, White C, Weinman JP, Huo D, et al. Radiation dose reduction using spectral shaping in pediatric non-contrast sinus CT. Pediatr Radiol. 2023;53:2069\u201378. https:\/\/doi.org\/10.1007\/s00247-023-05699-2.","journal-title":"Pediatr Radiol"},{"key":"2339_CR10","doi-asserted-by":"publisher","first-page":"709","DOI":"10.1148\/rg.2019180082","volume":"39","author":"RV Gottumukkala","year":"2019","unstructured":"Gottumukkala RV, Kalra MK, Tabari A, Otrakji A, Gee MS. Advanced CT Techniques for Decreasing Radiation Dose, Reducing Sedation Requirements, and Optimizing Image Quality in Children. Radiographics. 2019;39:709\u201326. https:\/\/doi.org\/10.1148\/rg.2019180082.","journal-title":"Radiographics"},{"key":"2339_CR11","doi-asserted-by":"publisher","first-page":"950","DOI":"10.2214\/AJR.12.9026","volume":"200","author":"C Zacharias","year":"2013","unstructured":"Zacharias C, Alessio AM, Otto RK, Iyer RS, Philips GS, Swanson JO, et al. Pediatric CT: Strategies to Lower Radiation Dose. Am J Roentgenol. 2013;200:950\u20136. https:\/\/doi.org\/10.2214\/AJR.12.9026.","journal-title":"Am J Roentgenol"},{"key":"2339_CR12","doi-asserted-by":"publisher","first-page":"130","DOI":"10.1148\/radiol.212579","volume":"303","author":"K Rajendran","year":"2022","unstructured":"Rajendran K, Petersilka M, Henning A, Shanblatt ER, Schmidt B, Flohr TG, et al. First Clinical Photon-counting Detector CT System: Technical Evaluation. Radiology. 2022;303:130\u20138. https:\/\/doi.org\/10.1148\/radiol.212579.","journal-title":"Radiology"},{"key":"2339_CR13","doi-asserted-by":"publisher","first-page":"729","DOI":"10.1148\/rg.2019180115","volume":"39","author":"S Leng","year":"2019","unstructured":"Leng S, Bruesewitz M, Tao S, Rajendran K, Halaweish AF, Campeau NG, et al. Photon-counting Detector CT: System Design and Clinical Applications of an Emerging Technology. Radiographics. 2019;39:729\u201343. https:\/\/doi.org\/10.1148\/rg.2019180115.","journal-title":"Radiographics"},{"key":"2339_CR14","doi-asserted-by":"publisher","first-page":"293","DOI":"10.1148\/radiol.2018172656","volume":"289","author":"MJ Willemink","year":"2018","unstructured":"Willemink MJ, Persson M, Pourmorteza A, Pelc NJ, Fleischmann D. Photon-counting CT: Technical Principles and Clinical Prospects. Radiology. 2018;289:293\u2013312. https:\/\/doi.org\/10.1148\/radiol.2018172656.","journal-title":"Radiology"},{"key":"2339_CR15","doi-asserted-by":"publisher","first-page":"126","DOI":"10.1016\/j.ejmp.2020.10.030","volume":"79","author":"T Flohr","year":"2020","unstructured":"Flohr T, Petersilka M, Henning A, Ulzheimer S, Ferda J, Schmidt B. Photon-counting CT review. Physica Med. 2020;79:126\u201336. https:\/\/doi.org\/10.1016\/j.ejmp.2020.10.030.","journal-title":"Physica Med"},{"key":"2339_CR16","doi-asserted-by":"publisher","first-page":"205019","DOI":"10.1088\/1361-6560\/ac155e","volume":"66","author":"K Rajendran","year":"2021","unstructured":"Rajendran K, Petersilka M, Henning A, Shanblatt E, Marsh J, Thorne J, et al. Full field-of-view, high-resolution, photon-counting detector CT: technical assessment and initial patient experience. Phys Med Biol. 2021;66:205019. https:\/\/doi.org\/10.1088\/1361-6560\/ac155e.","journal-title":"Phys Med Biol"},{"key":"2339_CR17","doi-asserted-by":"publisher","first-page":"W626","DOI":"10.2214\/AJR.12.10234","volume":"201","author":"X Duan","year":"2013","unstructured":"Duan X, Wang J, Leng S, Schmidt B, Allmendinger T, Grant K, et al. Electronic Noise in CT Detectors: Impact on Image Noise and Artifacts. Am J Roentgenol. 2013;201:W626\u201332. https:\/\/doi.org\/10.2214\/AJR.12.10234.","journal-title":"Am J Roentgenol"},{"key":"2339_CR18","doi-asserted-by":"publisher","first-page":"283","DOI":"10.1097\/RLI.0000000000000933","volume":"58","author":"CAS Dunning","year":"2023","unstructured":"Dunning CAS, Marsh JF, Winfree T, Rajendran K, Leng S, Levin DL, et al. Accuracy of Nodule Volume and Airway Wall Thickness Measurement Using Low-Dose Chest CT on a Photon-Counting Detector CT Scanner. Invest Radiol. 2023;58:283\u201392. https:\/\/doi.org\/10.1097\/RLI.0000000000000933.","journal-title":"Invest Radiol"},{"key":"2339_CR19","doi-asserted-by":"publisher","first-page":"e231741","DOI":"10.1148\/radiol.231741","volume":"311","author":"KK Horst","year":"2024","unstructured":"Horst KK, Cao JY, McCollough CH, El-Ali A, Frush DP, Siegel MJ, et al. Multi-institutional Protocol Guidance for Pediatric Photon-counting CT. Radiology. 2024;311:e231741. https:\/\/doi.org\/10.1148\/radiol.231741.","journal-title":"Radiology"},{"key":"2339_CR20","doi-asserted-by":"publisher","first-page":"303","DOI":"10.1148\/radiol.211780","volume":"303","author":"SA Si-Mohamed","year":"2022","unstructured":"Si-Mohamed SA, Boccalini S, Lacombe H, Diaw A, Varasteh M, Rodesch P-A, et al. Coronary CT Angiography with Photon-counting CT: First-In-Human Results. Radiology. 2022;303:303\u201313. https:\/\/doi.org\/10.1148\/radiol.211780.","journal-title":"Radiology"},{"key":"2339_CR21","doi-asserted-by":"publisher","first-page":"767","DOI":"10.1097\/RLI.0000000000000987","volume":"58","author":"V Mergen","year":"2023","unstructured":"Mergen V, Sartoretti T, Cundari G, Serifovic M, Higashigaito K, Allmendinger T, et al. The Importance of Temporal Resolution for Ultra-High-Resolution Coronary Angiography: Evidence From Photon-Counting Detector CT. Invest Radiol. 2023;58:767\u201374. https:\/\/doi.org\/10.1097\/RLI.0000000000000987.","journal-title":"Invest Radiol"},{"key":"2339_CR22","doi-asserted-by":"publisher","DOI":"10.1097\/RLI.0000000000000993","author":"AM Turrion Gomollon","year":"2023","unstructured":"Turrion Gomollon AM, Mergen V, Sartoretti T, Polacin M, Nakhostin D, Puippe G, et al. Photon-Counting Detector CT Angiography for Endoleak Detection After Endovascular Aortic Repair: Triphasic CT With True Noncontrast Versus Biphasic CT With Virtual Noniodine Imaging. Invest Radiol. 2023. https:\/\/doi.org\/10.1097\/RLI.0000000000000993.","journal-title":"Invest Radiol"},{"key":"2339_CR23","doi-asserted-by":"publisher","first-page":"1057","DOI":"10.1007\/s00247-022-05584-4","volume":"53","author":"I Tsiflikas","year":"2023","unstructured":"Tsiflikas I, Thater G, Ayx I, Weiss J, Schaefer J, Stein T, et al. Low dose pediatric chest computed tomography on a photon counting detector system \u2013 initial clinical experience. Pediatr Radiol. 2023;53:1057\u201362. https:\/\/doi.org\/10.1007\/s00247-022-05584-4.","journal-title":"Pediatr Radiol"},{"key":"2339_CR24","doi-asserted-by":"publisher","first-page":"363","DOI":"10.2214\/AJR.23.29077","volume":"221","author":"MJ Siegel","year":"2023","unstructured":"Siegel MJ, Bugenhagen SM, Sanchez A, Kim S, Abadia A, Ramirez-Giraldo JC. Comparison of Radiation Dose and Image Quality of Pediatric High-Resolution Chest CT Between Photon-Counting Detector CT and Energy-Integrated Detector CT: A Matched Study. Am J Roentgenol. 2023;221:363\u201371. https:\/\/doi.org\/10.2214\/AJR.23.29077.","journal-title":"Am J Roentgenol"},{"key":"2339_CR25","doi-asserted-by":"publisher","first-page":"1984","DOI":"10.1007\/s00247-024-06078-1","volume":"54","author":"AM El-Ali","year":"2024","unstructured":"El-Ali AM, Strubel N, Pinkney L, Xue C, Dane B, Lala SV. Pediatric contrast-enhanced chest CT on a photon-counting detector CT: radiation dose and image quality compared to energy-integrated detector CT. Pediatr Radiol. 2024;54:1984\u201395. https:\/\/doi.org\/10.1007\/s00247-024-06078-1.","journal-title":"Pediatr Radiol"},{"key":"2339_CR26","doi-asserted-by":"publisher","unstructured":"McCollough C, Bakalyar D, Bostani M, Brady S, Boedeker K, Boone J, et al. Use of Water Equivalent Diameter for Calculating Patient Size and Size-Specific Dose Estimates (SSDE) in CT. AAPM; 2014. https:\/\/doi.org\/10.37206\/146.","DOI":"10.37206\/146"},{"key":"2339_CR27","doi-asserted-by":"publisher","first-page":"1788","DOI":"10.1093\/bjr\/tqaf116","volume":"98","author":"L Ren","year":"2025","unstructured":"Ren L, Duan X, Ahn R, Kay F, Daftaribesheli L, Zhou W, et al. Photon-counting detector CT: technology overview and radiation dose reduction. Br J Radiol. 2025;98:1788\u2013801. https:\/\/doi.org\/10.1093\/bjr\/tqaf116.","journal-title":"Br J Radiol"},{"key":"2339_CR28","doi-asserted-by":"publisher","first-page":"522","DOI":"10.3390\/diagnostics12020522","volume":"12","author":"T Sartoretti","year":"2022","unstructured":"Sartoretti T, Racine D, Mergen V, Jungblut L, Monnin P, Flohr TG, et al. Quantum Iterative Reconstruction for Low-Dose Ultra-High-Resolution Photon-Counting Detector CT of the Lung. Diagnostics. 2022;12:522. https:\/\/doi.org\/10.3390\/diagnostics12020522.","journal-title":"Diagnostics"},{"key":"2339_CR29","doi-asserted-by":"publisher","first-page":"27774","DOI":"10.1038\/s41598-024-79188-3","volume":"14","author":"K Krompa\u00df","year":"2024","unstructured":"Krompa\u00df K, Goldbrunner FA, Hartung V, Erg\u00fcn S, Peter D, Hendel R, et al. Combined influence of quantum iterative reconstruction level and kernel sharpness on image quality in photon counting CT angiography of the upper leg. Sci Rep. 2024;14:27774. https:\/\/doi.org\/10.1038\/s41598-024-79188-3.","journal-title":"Sci Rep"},{"key":"2339_CR30","doi-asserted-by":"publisher","first-page":"umae012","DOI":"10.1093\/radadv\/umae012","volume":"1","author":"MJ Siegel","year":"2024","unstructured":"Siegel MJ, Ramirez-Giraldo JC. Photon counting detector computed tomography in pediatric cardiothoracic CT imaging. Radiol Adv. 2024;1:umae012. https:\/\/doi.org\/10.1093\/radadv\/umae012.","journal-title":"Radiol Adv"},{"key":"2339_CR31","doi-asserted-by":"publisher","first-page":"208","DOI":"10.1016\/j.ejrad.2017.01.027","volume":"89","author":"B Bodelle","year":"2017","unstructured":"Bodelle B, Fischbach C, Booz C, Yel I, Frellesen C, Beeres M, et al. Free-breathing high-pitch 80 kVp dual-source computed tomography of the pediatric chest: Image quality, presence of motion artifacts and radiation dose. Eur J Radiol. 2017;89:208\u201314. https:\/\/doi.org\/10.1016\/j.ejrad.2017.01.027.","journal-title":"Eur J Radiol"},{"key":"2339_CR32","doi-asserted-by":"publisher","first-page":"1191","DOI":"10.1007\/s00247-025-06235-0","volume":"55","author":"M Zellner","year":"2025","unstructured":"Zellner M, Sartoretti T, Flohr T, Frauenfelder T, Alkadhi H, Kellenberger CJ, et al. Paediatric high-pitch lung imaging with photon-counting detector computed tomography: a dose reduction phantom study. Pediatr Radiol. 2025;55:1191\u2013201. https:\/\/doi.org\/10.1007\/s00247-025-06235-0.","journal-title":"Pediatr Radiol"},{"key":"2339_CR33","doi-asserted-by":"publisher","first-page":"1556","DOI":"10.1007\/s00247-025-06274-7","volume":"55","author":"J Braaksma","year":"2025","unstructured":"Braaksma J, Greuter M, Verhagen M. Physics and rationale in pediatric abdomen photon counting detector computed tomography: an investigative review towards development of a pediatric abdomen protocol. Pediatr Radiol. 2025;55:1556\u201367. https:\/\/doi.org\/10.1007\/s00247-025-06274-7.","journal-title":"Pediatr Radiol"}],"container-title":["BMC Medical Imaging"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s12880-026-02339-7","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12880-026-02339-7.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12880-026-02339-7.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,5,26]],"date-time":"2026-05-26T12:09:28Z","timestamp":1779797368000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1186\/s12880-026-02339-7"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,4,16]]},"references-count":33,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2026,12]]}},"alternative-id":["2339"],"URL":"https:\/\/doi.org\/10.1186\/s12880-026-02339-7","relation":{},"ISSN":["1471-2342"],"issn-type":[{"value":"1471-2342","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,4,16]]},"assertion":[{"value":"20 February 2026","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"2 April 2026","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"16 April 2026","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"This study was conducted in accordance with the Declaration of Helsinki and approved by the Institutional Review Board of Renji Hospital (LY2024-036-B). This observational matched-cohort imaging study was not prospectively registered. Written informed consent was obtained from legal guardians of all subjects (patients) of in this study.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"The authors of this manuscript declare no generative AI use in this manuscript.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Generative AI use"}},{"value":"The authors declare no competing interests.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"270"}}