{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,8]],"date-time":"2026-10-08T22:53:22Z","timestamp":1791500002229,"version":"4.3.4"},"reference-count":23,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2026,7,15]],"date-time":"2026-07-15T00:00:00Z","timestamp":1784073600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"},{"start":{"date-parts":[[2026,10,9]],"date-time":"2026-10-09T00:00:00Z","timestamp":1791504000000},"content-version":"vor","delay-in-days":86,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"}],"funder":[{"DOI":"10.13039\/501100019978","name":"Shanghai Pudong New Area Health Commission","doi-asserted-by":"publisher","award":["PWZxk2022-12"],"award-info":[{"award-number":["PWZxk2022-12"]}],"id":[{"id":"10.13039\/501100019978","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Med Imaging"],"DOI":"10.1186\/s12880-026-02568-w","type":"journal-article","created":{"date-parts":[[2026,7,15]],"date-time":"2026-07-15T05:14:22Z","timestamp":1784092462000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Deep progressive learning reconstruction for fast and low-dose whole-body PET scans in an integrated PET\/MR system"],"prefix":"10.1186","volume":"26","author":[{"given":"Jie","family":"Ding","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yihong","family":"Yang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Zhe","family":"Wang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Haiyan","family":"Wang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Na","family":"Qi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Zirong","family":"Zhou","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xing","family":"Chen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Zhiwen","family":"You","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Chen","family":"Xi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Zheng","family":"Qian","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Lingzhi","family":"Hu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jianmin","family":"Yuan","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jun","family":"Zhao","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,7,15]]},"reference":[{"key":"2568_CR1","doi-asserted-by":"publisher","unstructured":"Guedj E, Varrone A, Boellaard R, Albert NL, Barthel H, et al. EANM procedure guidelines for brain PET imaging using [18F]FDG, version 3. Eur J Nucl Med Mol Imaging. 2022 Jan;49(2):632\u201351. https:\/\/doi.org\/10.1007\/s00259-021-05603-w.","DOI":"10.1007\/s00259-021-05603-w"},{"key":"2568_CR2","doi-asserted-by":"publisher","unstructured":"Law I, Albert NL, Arbizu J, Boellaard R, Drzezga A, et al. Joint EANM\/EANO\/RANO practice guidelines\/SNMMI procedure standards for imaging of gliomas using PET with radiolabelled amino acids and [18F]FDG: version 1.0. Eur J Nucl Med Mol Imaging. 2019 Mar;46(3):540\u201357. https:\/\/doi.org\/10.1007\/s00259-018-4207-9.","DOI":"10.1007\/s00259-018-4207-9"},{"key":"2568_CR3","doi-asserted-by":"publisher","unstructured":"Fletcher JW, Djulbegovic B, Soares HP, Siegel BA, Lowe VJ, et al. Recommendations on the use of 18F-FDG PET in oncology. J Nucl Med. 2008 Mar;49(3):480\u2013508. https:\/\/doi.org\/10.2967\/jnumed.107.047787.","DOI":"10.2967\/jnumed.107.047787"},{"key":"2568_CR4","doi-asserted-by":"publisher","unstructured":"Wyatt JJ, Kaushik S, Cozzini C, Pearson RA, Petrides G, et al. Evaluating a radiotherapy deep learning synthetic CT algorithm for PET-MR attenuation correction in the pelvis. EJNMMI Phys. 2024 Jan 29;11(1):10. https:\/\/doi.org\/10.1186\/s40658-024-00617-3.","DOI":"10.1186\/s40658-024-00617-3"},{"key":"2568_CR5","doi-asserted-by":"publisher","unstructured":"Krokos G, MacKewn J, Dunn J. Marsden P A review of PET attenuation correction methods for PET-MR. EJNMMI Phys. 2023 Sep 11;10(1):52. https:\/\/doi.org\/10.1186\/s40658-023-00569-0.","DOI":"10.1186\/s40658-023-00569-0"},{"key":"2568_CR6","doi-asserted-by":"publisher","unstructured":"Tong S, Alessio AM, Kinahan PE. Image reconstruction for PET\/CT scanners: past achievements and future challenges. Imaging Med. 2010 Oct 1;2(5):529\u201345. https:\/\/doi.org\/10.2217\/iim.10.49.","DOI":"10.2217\/iim.10.49"},{"issue":"4","key":"2568_CR7","doi-asserted-by":"publisher","first-page":"601","DOI":"10.1109\/42.363108","volume":"13","author":"HM Hudson","year":"1994","unstructured":"Hudson HM, Larkin RS. Accelerated image reconstruction using ordered subsets of projection data. IEEE Trans Med Imaging. 1994;13(4):601\u20139. https:\/\/doi.org\/10.1109\/42.363108.","journal-title":"IEEE Trans Med Imaging"},{"key":"2568_CR8","doi-asserted-by":"publisher","unstructured":"Bal A, Banerjee M, Sharma P, Maitra M. An efficient wavelet and curvelet-based PET image denoising technique. Med Biol Eng Comput. 2019 Dec;57(12):2567\u201398. https:\/\/doi.org\/10.1007\/s11517-019-02014-w.","DOI":"10.1007\/s11517-019-02014-w"},{"issue":"12","key":"2568_CR9","doi-asserted-by":"publisher","first-page":"e81390","DOI":"10.1371\/journal.pone.0081390","volume":"8","author":"J Dutta","year":"2013","unstructured":"Dutta J, Leahy RM, Li Q. Non-local means denoising of dynamic PET images. PLoS ONE. 2013;8(12):e81390. https:\/\/doi.org\/10.1371\/journal.pone.0081390.","journal-title":"PLoS ONE"},{"key":"2568_CR10","doi-asserted-by":"publisher","unstructured":"Arabi H, Zaidi H. Non-local mean denoising using multiple PET reconstructions. Ann Nucl Med. 2021 Feb;35(2):176\u201386. https:\/\/doi.org\/10.1007\/s12149-020-01550-y.","DOI":"10.1007\/s12149-020-01550-y"},{"key":"2568_CR11","doi-asserted-by":"publisher","unstructured":"Zhou L, Schaefferkoetter JD, Tham IWK, Huang G, Yan J. Supervised learning with CycleGAN for low-dose FDG PET image denoising. Med Image Anal. 2020 Oct;65:101770. https:\/\/doi.org\/10.1016\/j.media.2020.101770.","DOI":"10.1016\/j.media.2020.101770"},{"key":"2568_CR12","doi-asserted-by":"publisher","unstructured":"Jacobson M, Levkovitz R, Ben-Tal A, Thielemans K, Spinks T, et al. Enhanced 3D PET OSEM reconstruction using inter-update Metz filtering. Phys Med Biol. 2000 Aug;45(8):2417\u201339. https:\/\/doi.org\/10.1088\/0031-9155\/45\/8\/325.","DOI":"10.1088\/0031-9155\/45\/8\/325"},{"key":"2568_CR13","doi-asserted-by":"publisher","unstructured":"Mehranian A, Wollenweber SD, Walker MD, Bradley KM, Fielding PA, et al. Image enhancement of whole-body oncology [18F]-FDG PET scans using deep neural networks to reduce noise. Eur J Nucl Med Mol Imagjng. 2022 Jan;49(2):539\u201349. https:\/\/doi.org\/10.1007\/s00259-021-05478-x.","DOI":"10.1007\/s00259-021-05478-x"},{"key":"2568_CR14","doi-asserted-by":"publisher","unstructured":"Zaker N, Haddad K, Faghihi R, Arabi H, Zaidi H. Direct inference of Patlak parametric images in whole-body PET\/CT imaging using convolutional neural networks. Eur J Nucl Med Mol Imaging. 2022 Oct;49(12):4048\u201363. https:\/\/doi.org\/10.1007\/s00259-022-05867-w.","DOI":"10.1007\/s00259-022-05867-w"},{"key":"2568_CR15","doi-asserted-by":"publisher","unstructured":"Schaefferkoetter J, Yan J, Ortega C, Sertic A, Lechtman E, et al. Convolutional neural networks for improving image quality with noisy PET data. EJNMMI Res. 2020 Sep 21;10(1):105. https:\/\/doi.org\/10.1186\/s13550-020-00695-1.","DOI":"10.1186\/s13550-020-00695-1"},{"key":"2568_CR16","doi-asserted-by":"publisher","unstructured":"Hu Y, Lv D, Jian S, Lang L, Cui C et al. Comparative study of the quantitative accuracy of oncological PET imaging based on deep learning methods. Quant Imaging Med Surg. 2023 Jun 1;13(6):3760\u201375. https:\/\/doi.org\/10.21037\/qims-22-1181.","DOI":"10.21037\/qims-22-1181"},{"key":"2568_CR17","doi-asserted-by":"publisher","unstructured":"Xing Y, Qiao W, Wang T, Wang Y, Li C, et al. Deep learning-assisted PET imaging achieves fast scan\/low-dose examination. EJNMMI Phys. 2022 Feb 4;9(1):7. https:\/\/doi.org\/10.1186\/s40658-022-00431-9.","DOI":"10.1186\/s40658-022-00431-9"},{"key":"2568_CR18","doi-asserted-by":"publisher","unstructured":"Tsuchiya J, Yokoyama K, Yamagiwa K, Watanabe R, Kimura K, et al. Deep learning-based image quality improvement of (18)F-fluorodeoxyglucose positron emission tomography: a retrospective observational study. EJNMMI Phys. 2021 Mar 25;8(1):31. https:\/\/doi.org\/10.1186\/s40658-021-00377-4.","DOI":"10.1186\/s40658-021-00377-4"},{"key":"2568_CR19","doi-asserted-by":"publisher","unstructured":"Wang T, Qiao W, Wang Y, Wang J, Lv Y, et al. Deep progressive learning achieves whole-body low-dose (18)F-FDG PET imaging. EJNMMI Phys. 2022 Nov 22;9(1):82. https:\/\/doi.org\/10.1186\/s40658-022-00508-5.","DOI":"10.1186\/s40658-022-00508-5"},{"key":"2568_CR20","doi-asserted-by":"publisher","unstructured":"Yang H, Chen S, Qi M, Chen W, Kong Q, et al. Investigation of PET image quality with acquisition time\/bed and enhancement of lesion quantification accuracy through deep progressive learning. EJNMMI Phys. 2024 Jan 10;11(1):7. https:\/\/doi.org\/10.1186\/s40658-023-00607-x.","DOI":"10.1186\/s40658-023-00607-x"},{"key":"2568_CR21","doi-asserted-by":"publisher","unstructured":"Beyer T, Weigert M, Quick HH, Pietrzyk U, Vogt F, et al. MR-based attenuation correction for torso-PET\/MR imaging: pitfalls in mapping MR to CT data. Eur J Nucl Med Mol Imaging. 2008 Jun;35(6):1142\u20136. https:\/\/doi.org\/10.1007\/s00259-008-0734-0","DOI":"10.1007\/s00259-008-0734-0"},{"key":"2568_CR22","doi-asserted-by":"publisher","unstructured":"Katsari K, Penna D, Arena V, Polverari G, Ianniello A, et al. Artificial intelligence for reduced dose 18F-FDG PET examinations: a real-world deployment through a standardized framework and business case assessment. EJNMMI Phys. 2021 Mar 9;8(1):25. https:\/\/doi.org\/10.1186\/s40658-021-00374-7.","DOI":"10.1186\/s40658-021-00374-7"},{"key":"2568_CR23","doi-asserted-by":"publisher","unstructured":"Lv Y, Xi C. PET image reconstruction with deep progressive learning. Phys Med Biol. 2021;66(10). https:\/\/doi.org\/10.1088\/1361-6560\/abfb17. PMID: 33892485.","DOI":"10.1088\/1361-6560\/abfb17"}],"container-title":["BMC Medical Imaging"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s12880-026-02568-w","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12880-026-02568-w.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12880-026-02568-w.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,10,8]],"date-time":"2026-10-08T22:36:43Z","timestamp":1791499003000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1186\/s12880-026-02568-w"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,7,15]]},"references-count":23,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2026,12]]}},"alternative-id":["2568"],"URL":"https:\/\/doi.org\/10.1186\/s12880-026-02568-w","relation":{},"ISSN":["1471-2342"],"issn-type":[{"value":"1471-2342","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,7,15]]},"assertion":[{"value":"25 November 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"3 July 2026","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"15 July 2026","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"All procedures performed in studies involving human participants were in accordance with the ethical standards of the institutional review board of Shanghai East Hospital (IRB protocol 2020085) and with the 1964 Helsinki declaration and its later amendments. The necessity for written informed consent was waived by the IRB for the simulated retrospective cohort, while written informed consent was obtained from all patients in the real half injected activity prospective cohort.","order":1,"name":"Ethics","label":"Ethical approval","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Not applicable.","order":2,"name":"Ethics","label":"Consent for publication","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The authors declare no competing interests.","order":3,"name":"Ethics","label":"Competing interests","group":{"name":"EthicsHeading","label":"Declarations"}}],"article-number":"511"}}