{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,9]],"date-time":"2026-07-09T19:52:01Z","timestamp":1783626721179,"version":"3.55.0"},"reference-count":41,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2021,2,8]],"date-time":"2021-02-08T00:00:00Z","timestamp":1612742400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2021,2,8]],"date-time":"2021-02-08T00:00:00Z","timestamp":1612742400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/501100004115","name":"Gottfried Wilhelm Leibniz Universit\u00e4t Hannover","doi-asserted-by":"crossref","id":[{"id":"10.13039\/501100004115","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["EURASIP J. Adv. Signal Process."],"published-print":{"date-parts":[[2021,12]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:p>Reliability and user compliance of the applied sensor system are two key issues of digital healthcare and biomedical informatics. For gait assessment applications, accurate joint angle measurements are important. Inertial measurement units (IMUs) have been used in a variety of applications and can also provide significant information on gait kinematics. However, the nonlinear mechanism of human locomotion results in moderate estimation accuracy of the gait kinematics and thus joint angles. To develop \u201cdigital twins\u201d as a digital counterpart of body lower limb joint angles, three-dimensional gait kinematic data were collected. This work investigates the estimation accuracy of different neural networks in modeling lower body joint angles in the sagittal plane using the kinematic records of a single IMU attached to the foot. The evaluation results based on the root mean square error (RMSE) show that long short-term memory (LSTM) networks deliver superior performance in nonlinear modeling of the lower limb joint angles compared to other machine learning (ML) approaches. Accordingly, deep learning based on the LSTM architecture is a promising approach in modeling of gait kinematics using a single IMU, and thus can reduce the required physical IMUs attached on the subject and improve the practical application of the sensor system.<\/jats:p>","DOI":"10.1186\/s13634-020-00715-1","type":"journal-article","created":{"date-parts":[[2021,2,8]],"date-time":"2021-02-08T22:46:35Z","timestamp":1612824395000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":37,"title":["Efficiency of deep neural networks for joint angle modeling in digital gait assessment"],"prefix":"10.1186","volume":"2021","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-0719-1551","authenticated-orcid":false,"given":"Javier","family":"Conte Alcaraz","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sanam","family":"Moghaddamnia","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"J\u00fcrgen","family":"Peissig","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2021,2,8]]},"reference":[{"issue":"10","key":"715_CR1","doi-asserted-by":"publisher","first-page":"1569","DOI":"10.3390\/s16101569","volume":"16","author":"J. Mendes Jr","year":"2016","unstructured":"J. Mendes Jr, M. Vieira, M. Pires, S. Stevan Jr, Sensor Fusion and Smart Sensor in Sports and Biomedical Applications. Sensors. 16(10), 1569 (2016). https:\/\/doi.org\/10.3390\/s16101569.","journal-title":"Sensors"},{"issue":"2","key":"715_CR2","doi-asserted-by":"publisher","first-page":"1187","DOI":"10.1109\/JSEN.2020.3019016","volume":"21","author":"M. Rana","year":"2021","unstructured":"M. Rana, V. Mittal, Wearable sensors for real-time kinematics analysis in sports: a review. IEEE Sensors J.21(2), 1187\u20131207 (2021). https:\/\/doi.org\/10.1109\/JSEN.2020.3019016.","journal-title":"IEEE Sensors J."},{"issue":"10","key":"715_CR3","doi-asserted-by":"publisher","first-page":"3533","DOI":"10.3390\/s18103533","volume":"18","author":"N. Mohammadian Rad","year":"2018","unstructured":"N. Mohammadian Rad, T. Van Laarhoven, C. Furlanello, E. Marchiori, Novelty detection using deep normative modeling for IMU-based abnormal movement monitoring in Parkinson\u2019s disease and autism spectrum disorders. Sensors. 18(10), 3533 (2018). https:\/\/doi.org\/10.3390\/s18103533.","journal-title":"Sensors"},{"issue":"9","key":"715_CR4","doi-asserted-by":"publisher","first-page":"442","DOI":"10.3390\/mi9090442","volume":"9","author":"S. Qiu","year":"2018","unstructured":"S. Qiu, L. Liu, H. Zhao, Z. Wang, Y. Jiang, MEMS inertial sensors based gait analysis for rehabilitation assessment via multi-sensor fusion. Micromachines. 9(9), 442 (2018). https:\/\/doi.org\/10.3390\/mi9090442.","journal-title":"Micromachines"},{"issue":"9","key":"715_CR5","doi-asserted-by":"publisher","first-page":"2828","DOI":"10.3390\/s18092828","volume":"18","author":"D. Kobsar","year":"2018","unstructured":"D. Kobsar, R. Ferber, Wearable sensor data to track subject-specific movement patterns related to clinical outcomes using a machine learning approach. Sensors. 18(9), 2828 (2018). https:\/\/doi.org\/10.3390\/s18092828.","journal-title":"Sensors"},{"key":"715_CR6","unstructured":"C. Mao, Y. Li, F. Sun, in 2018 IEEE 23rd International Conference on Digital Signal Processing (DSP). Accelerometer-Based Gait Recognition Using PCA LDA Algorithms, (2018), pp. 1\u20134."},{"issue":"2","key":"715_CR7","doi-asserted-by":"publisher","first-page":"40","DOI":"10.1002\/cplx.20151","volume":"12","author":"G. Mayer-Kress","year":"2006","unstructured":"G. Mayer-Kress, Y. T. Liu, K. M. Newell, Complex systems and human movement. Complexity. 12(2), 40\u201351 (2006). https:\/\/doi.org\/10.1002\/cplx.20151.","journal-title":"Complexity"},{"key":"715_CR8","doi-asserted-by":"publisher","unstructured":"J. Conte Alcaraz, S. Moghaddamnia, M. Fuhrwerk, J. Peissig, in 2019 27th European Signal Processing Conference (EUSIPCO). Efficiency of the Memory Polynomial Model in Realizing Digital Twins for Gait Assessment, (2019), pp. 1\u20135. https:\/\/doi.org\/10.23919\/EUSIPCO.2019.8903143.","DOI":"10.23919\/EUSIPCO.2019.8903143"},{"issue":"10","key":"715_CR9","doi-asserted-by":"publisher","first-page":"4253","DOI":"10.1109\/JSEN.2018.2817228","volume":"18","author":"A. Baghdadi","year":"2018","unstructured":"A. Baghdadi, L. A. Cavuoto, J. L. Crassidis, Hip and trunk kinematics estimation in gait through Kalman filter using IMU data at the ankle. IEEE Sensors J.18(10), 4253\u20134260 (2018).","journal-title":"IEEE Sensors J."},{"issue":"1","key":"715_CR10","doi-asserted-by":"publisher","first-page":"72","DOI":"10.1109\/TBME.2012.2223465","volume":"60","author":"A. Salarian","year":"2013","unstructured":"A. Salarian, P. R. Burkhard, F. J. G. Vingerhoets, B. M. Jolles, K. Aminian, A novel approach to reducing number of sensing units for wearable gait analysis systems. IEEE Trans. Biomed. Eng.60(1), 72\u201377 (2013). https:\/\/doi.org\/10.1109\/TBME.2012.2223465.","journal-title":"IEEE Trans. Biomed. Eng."},{"issue":"21","key":"715_CR11","doi-asserted-by":"publisher","first-page":"9575","DOI":"10.1109\/JSEN.2019.2928777","volume":"19","author":"A. S. Alharthi","year":"2019","unstructured":"A. S. Alharthi, S. U. Yunas, K. B. Ozanyan, Deep learning for monitoring of human gait: a review. IEEE Sensors J.19(21), 9575\u20139591 (2019). https:\/\/doi.org\/10.1109\/JSEN.2019.2928777.","journal-title":"IEEE Sensors J."},{"issue":"20","key":"715_CR12","doi-asserted-by":"publisher","first-page":"1920","DOI":"10.1161\/CIRCULATIONAHA.115.001593","volume":"132","author":"R. C. Deo","year":"2015","unstructured":"R. C. Deo, Machine learning in medicine. Circulation. 132(20), 1920\u20131930 (2015). https:\/\/doi.org\/10.1161\/CIRCULATIONAHA.115.001593.","journal-title":"Circulation"},{"key":"715_CR13","doi-asserted-by":"publisher","unstructured":"T. Zebin, P. J. Scully, K. B. Ozanyan, in 2016 IEEE SENSORS. Human activity recognition with inertial sensors using a deep learning approach, (2016), pp. 1\u20133. https:\/\/doi.org\/10.1109\/ICSENS.2016.7808590.","DOI":"10.1109\/ICSENS.2016.7808590"},{"key":"715_CR14","doi-asserted-by":"publisher","unstructured":"F. J. Ord\u00f3\u00f1ez, D. Roggen, Deep convolutional and LSTM recurrent neural networks for multimodal wearable activity recognition. Sensors. 16(1) (2016). https:\/\/doi.org\/10.3390\/s16010115.","DOI":"10.3390\/s16010115"},{"key":"715_CR15","doi-asserted-by":"publisher","unstructured":"T. Zebin, M. Sperrin, N. Peek, A. J. Casson, in 2018 40th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC). Human activity recognition from inertial sensor time-series using batch normalized deep LSTM recurrent networks, (2018), pp. 1\u20134. https:\/\/doi.org\/10.1109\/EMBC.2018.8513115.","DOI":"10.1109\/EMBC.2018.8513115"},{"key":"715_CR16","doi-asserted-by":"publisher","first-page":"2735","DOI":"10.3390\/s17122735","volume":"17","author":"O. Dehzangi","year":"2017","unstructured":"O. Dehzangi, M. Taherisadr, R. ChangalVala, IMU-based gait recognition using convolutional neural networks and multi-sensor fusion. Sensors. 17:, 2735 (2017). https:\/\/doi.org\/10.3390\/s17122735.","journal-title":"Sensors"},{"issue":"23","key":"715_CR17","doi-asserted-by":"publisher","first-page":"5325","DOI":"10.3390\/s19235325","volume":"19","author":"A. Rezaei","year":"2019","unstructured":"Gholami M., A. Rezaei, T. J. Cuthbert, C. Napier, C. Menon, Lower Body Kinematics Monitoring in Running Using Fabric-Based Wearable Sensors and Deep Convolutional Neural Networks. Sensors. 19(23), 5325 (2019). https:\/\/doi.org\/10.3390\/s19235325.","journal-title":"Sensors"},{"issue":"1","key":"715_CR18","doi-asserted-by":"publisher","first-page":"211","DOI":"10.1007\/s11517-019-02061-3","volume":"58","author":"M. Mundt","year":"2020","unstructured":"M. Mundt, W. Thomsen, T. Witter, A. Koeppe, S. David, F. Bamer, W. Potthast, B. Markert, Prediction of lower limb joint angles and moments during gait using artificial neural networks. Med. Biol. Eng. Comput.58(1), 211\u2013225 (2020). https:\/\/doi.org\/10.1007\/s11517-019-02061-3.","journal-title":"Med. Biol. Eng. Comput."},{"issue":"1","key":"715_CR19","doi-asserted-by":"publisher","first-page":"120","DOI":"10.1016\/j.gaitpost.2007.11.001","volume":"28","author":"A. Findlow","year":"2008","unstructured":"A. Findlow, J. Y. Goulermas, C. Nester, D. Howard, L. P. J. Kenney, Predicting lower limb joint kinematics using wearable motion sensors. Gait & Posture. 28(1), 120\u2013126 (2008). https:\/\/doi.org\/10.1016\/j.gaitpost.2007.11.001.","journal-title":"Gait & Posture"},{"key":"715_CR20","doi-asserted-by":"publisher","first-page":"43","DOI":"10.5277\/ABB-01129-2018-02","volume":"20","author":"M. B\u0142a\u017bkiewicz","year":"2018","unstructured":"M. B\u0142a\u017bkiewicz, A. Wit, Artificial neural network simulation of lower limb joint angles in normal and impaired human gait. Acta Bioeng. Biomech.20:, 43\u201349 (2018). https:\/\/doi.org\/10.5277\/ABB-01129-2018-02.","journal-title":"Acta Bioeng. Biomech."},{"issue":"1","key":"715_CR21","doi-asserted-by":"publisher","first-page":"85","DOI":"10.1109\/JBHI.2016.2636456","volume":"21","author":"J. Hannink","year":"2017","unstructured":"J. Hannink, T. Kautz, C. F. Pasluosta, K. Ga\u00dfmann, J. Klucken, B. M. Eskofier, Sensor-based gait parameter extraction with deep convolutional neural networks. IEEE J. Biomed. Health Inform.21(1), 85\u201393 (2017). https:\/\/doi.org\/10.1109\/JBHI.2016.2636456.","journal-title":"IEEE J. Biomed. Health Inform."},{"key":"715_CR22","doi-asserted-by":"publisher","unstructured":"H. Wu, Q. Huang, D. Wang, L. Gao, in 2019 IEEE 3rd Information Technology, Networking, Electronic and Automation Control Conference (ITNEC). A CNN-SVM Combined Regression Model for Continuous Knee Angle Estimation Using Mechanomyography Signals, (2019), pp. 124\u2013131. https:\/\/doi.org\/10.1109\/ITNEC.2019.8729426.","DOI":"10.1109\/ITNEC.2019.8729426"},{"key":"715_CR23","doi-asserted-by":"publisher","unstructured":"J. Conte Alcaraz, S. Moghaddamnia, J. Peissig, in 2017 22nd International Conference on Digital Signal Processing (DSP). Mobile quantification and therapy course tracking for gait rehabilitation, (2017), pp. 1\u20135. https:\/\/doi.org\/10.1109\/ICDSP.2017.8096106.","DOI":"10.1109\/ICDSP.2017.8096106"},{"key":"715_CR24","volume-title":"Gait analysis : normal and pathological function, 2nd ed.","author":"J. Perry","year":"2010","unstructured":"J. Perry, J. M. Burnfield, in Gait analysis : normal and pathological function, 2nd ed.Gait analysis : normal and pathological function (SLACKThorofare, 2010)."},{"key":"715_CR25","doi-asserted-by":"publisher","first-page":"76","DOI":"10.1016\/j.gaitpost.2018.08.025","volume":"66","author":"G. P. Panebianco","year":"2018","unstructured":"G. P. Panebianco, M. C. Bisi, R. Stagni, S. Fantozzi, Analysis of the performance of 17 algorithms from a systematic review: influence of sensor position, analyzed variable and computational approach in gait timing estimation from IMU measurements. Gait & Posture. 66:, 76\u201382 (2018).","journal-title":"Gait & Posture"},{"issue":"3","key":"715_CR26","doi-asserted-by":"publisher","first-page":"486","DOI":"10.1109\/TBME.2004.840727","volume":"52","author":"A. M. Sabatini","year":"2005","unstructured":"A. M. Sabatini, C. Martelloni, S. Scapellato, F. Cavallo, Assessment of walking features from foot inertial sensing. IEEE Trans. Biomed. Eng.52(3), 486\u2013494 (2005). https:\/\/doi.org\/10.1109\/TBME.2004.840727.","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"715_CR27","doi-asserted-by":"publisher","first-page":"15","DOI":"10.5815\/ijieeb.2012.02.03","volume":"4","author":"A. Goshvarpour","year":"2012","unstructured":"A. Goshvarpour, A. Goshvarpour, Nonlinear Analysis of Human Gait Signals. Int. J. Inf. Eng. Electron. Bus.4:, 15\u201321 (2012). https:\/\/doi.org\/10.5815\/ijieeb.2012.02.03.","journal-title":"Int. J. Inf. Eng. Electron. Bus."},{"key":"715_CR28","doi-asserted-by":"publisher","first-page":"903","DOI":"10.1098\/rspa.1998.0193","volume":"454","author":"N. Huang","year":"1998","unstructured":"N. Huang, Z. Shen, S. R. Long, M. L. C. Wu, H. H. Shih, Q. Zheng, N. C. Yen, C. C. Tung, H. H. Liu, The empirical mode decomposition and the Hilbert spectrum for nonlinear and non-stationary time series analysis. Proc. R. Soc. Lond. Ser. A: Math. Phys. Eng. Sci.454:, 903\u2013995 (1998). https:\/\/doi.org\/10.1098\/rspa.1998.0193.","journal-title":"Proc. R. Soc. Lond. Ser. A: Math. Phys. Eng. Sci."},{"key":"715_CR29","doi-asserted-by":"publisher","unstructured":"G. Huang, C. Wu, J. Lin, in 2012 International Conference on Computerized Healthcare (ICCH). Gait analysis by using tri-axial accelerometer of smart phones, (2012), pp. 29\u201334. https:\/\/doi.org\/10.1109\/ICCH.2012.6724466.","DOI":"10.1109\/ICCH.2012.6724466"},{"key":"715_CR30","volume-title":"Principles of Neurodynamics: Perceptrons and the Theory of Brain Mechanisms. Report (Cornell Aeronautical Laboratory)","author":"F. Rosenblatt","year":"1962","unstructured":"F. Rosenblatt, Principles of Neurodynamics: Perceptrons and the Theory of Brain Mechanisms. Report (Cornell Aeronautical Laboratory) (Spartan Books, Washington, 1962)."},{"key":"715_CR31","doi-asserted-by":"publisher","DOI":"10.5772\/intechopen.80258","volume-title":"Applications of General Regression Neural Networks in Dynamic Systems","author":"A. J. Al-mahasneh","year":"2018","unstructured":"A. J. Al-mahasneh, S. G. Anavatti, M. Pratama, Applications of General Regression Neural Networks in Dynamic Systems (IntechOpen, Rijeka, 2018). https:\/\/doi.org\/10.5772\/intechopen.80258."},{"key":"715_CR32","doi-asserted-by":"publisher","first-page":"568","DOI":"10.1109\/72.97934","volume":"2","author":"D. Specht","year":"1991","unstructured":"D. Specht, A general regression neural network. IEEE Trans. Neural Netw.2:, 568\u2013576 (1991). https:\/\/doi.org\/10.1109\/72.97934.","journal-title":"IEEE Trans. Neural Netw."},{"issue":"1","key":"715_CR33","doi-asserted-by":"publisher","first-page":"4","DOI":"10.1109\/72.80202","volume":"1","author":"K. S. Narendra","year":"1990","unstructured":"K. S. Narendra, K. Parthasarathy, Identification and control of dynamical systems using neural networks. IEEE Trans. Neural Netw.1(1), 4\u201327 (1990). https:\/\/doi.org\/10.1109\/72.80202.","journal-title":"IEEE Trans. Neural Netw."},{"key":"715_CR34","doi-asserted-by":"publisher","first-page":"101968","DOI":"10.1016\/j.bspc.2020.101968","volume":"60","author":"R. Gupta","year":"2020","unstructured":"R. Gupta, I. S. Dhindsa, R. Agarwal, Continuous angular position estimation of human ankle during unconstrained locomotion. Biomed. Signal Process. Control. 60:, 101968 (2020).","journal-title":"Biomed. Signal Process. Control"},{"issue":"17","key":"715_CR35","doi-asserted-by":"publisher","first-page":"4966","DOI":"10.3390\/s20174966","volume":"20","author":"X. Ma","year":"2020","unstructured":"X. Ma, Y. Liu, Q. Song, C. Wang, Continuous Estimation of Knee Joint Angle Based on Surface Electromyography Using a Long Short-Term Memory Neural Network and Time-Advanced Feature. Sensors. 20(17), 4966 (2020). https:\/\/doi.org\/10.3390\/s20174966.","journal-title":"Sensors"},{"key":"715_CR36","unstructured":"H. Liu, X. Song, in 2015 10th Asian Control Conference (ASCC). Nonlinear system identification based on NARX network, (2015), pp. 1\u20136."},{"key":"715_CR37","unstructured":"X. Glorot, Y. Bengio, in AISTATS, 9. Understanding the difficulty of training deep feedforward neural networks, (2010), pp. 249\u2013256."},{"issue":"4","key":"715_CR38","doi-asserted-by":"publisher","first-page":"525","DOI":"10.1016\/S0893-6080(05)80056-5","volume":"6","author":"M. F. M\u00f8ller","year":"1993","unstructured":"M. F. M\u00f8ller, A scaled conjugate gradient algorithm for fast supervised learning. Neural Netw.6(4), 525\u2013533 (1993). https:\/\/doi.org\/10.1016\/S0893-6080(05)80056-5.","journal-title":"Neural Netw."},{"key":"715_CR39","unstructured":"D. P. Kingma, J. Ba, in 3rd International Conference on Learning Representations, ICLR 2015, San Diego, CA, USA, May 7-9, 2015, Conference Track Proceedings, ed. by Y Bengio, Y LeCun. Adam: A Method for Stochastic Optimization, (2015), pp. 1\u201315. http:\/\/arxiv.org\/abs\/1412.6980."},{"key":"715_CR40","volume-title":"Deep Learning","author":"I. Goodfellow","year":"2016","unstructured":"I. Goodfellow, Y. Bengio, A. Courville, Deep Learning (MIT Press, Cambridge, 2016)."},{"key":"715_CR41","doi-asserted-by":"publisher","unstructured":"S. -M. Lee, S. M. Yoon, H. Cho, in 2017 IEEE International Conference on Big Data and Smart Computing (BigComp). Human activity recognition from accelerometer data using convolutional neural network, (2017), pp. 131\u2013134. https:\/\/doi.org\/10.1109\/BIGCOMP.2017.7881728.","DOI":"10.1109\/BIGCOMP.2017.7881728"}],"container-title":["EURASIP Journal on Advances in Signal Processing"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1186\/s13634-020-00715-1.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1186\/s13634-020-00715-1\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1186\/s13634-020-00715-1.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,2,8]],"date-time":"2021-02-08T22:47:53Z","timestamp":1612824473000},"score":1,"resource":{"primary":{"URL":"https:\/\/asp-eurasipjournals.springeropen.com\/articles\/10.1186\/s13634-020-00715-1"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,2,8]]},"references-count":41,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2021,12]]}},"alternative-id":["715"],"URL":"https:\/\/doi.org\/10.1186\/s13634-020-00715-1","relation":{},"ISSN":["1687-6180"],"issn-type":[{"value":"1687-6180","type":"electronic"}],"subject":[],"published":{"date-parts":[[2021,2,8]]},"assertion":[{"value":"10 February 2020","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"25 December 2020","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"8 February 2021","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"10"}}