{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,24]],"date-time":"2026-11-24T18:25:39Z","timestamp":1795544739147,"version":"4.11.0"},"reference-count":13,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2021,3,25]],"date-time":"2021-03-25T00:00:00Z","timestamp":1616630400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2021,3,25]],"date-time":"2021-03-25T00:00:00Z","timestamp":1616630400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["J Wireless Com Network"],"published-print":{"date-parts":[[2021,12]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>This paper proposes a matrix operation method for modeling the three-phase transformer by phase-coordinates. Based on decoupling theory, the 12\u2009\u00d7\u200912 dimension primitive admittance matrix is obtained at first employing the coupling configuration of the windings. Under the condition of asymmetric magnetic circuits, according to the boundary conditions for transformer connections, the transformers in different connections enable to be modeling by the matrix operation method from the primitive admittance matrix. Another purpose of this paper is to explain the differences of the phase-coordinates and the positive sequence parameters in the impedances of the transformers. The numerical testing results in IEEE-4 system show that the proposed method is valid and efficient.<\/jats:p>","DOI":"10.1186\/s13638-021-01945-z","type":"journal-article","created":{"date-parts":[[2021,3,25]],"date-time":"2021-03-25T18:03:57Z","timestamp":1616695437000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":4,"title":["Three-phase distribution transformer connections modeling based on matrix operation method by phase-coordinates"],"prefix":"10.1186","volume":"2021","author":[{"given":"Zhigang","family":"Zhang","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-8148-2635","authenticated-orcid":false,"given":"Mingrui","family":"Mo","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Caizhu","family":"Wu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2021,3,25]]},"reference":[{"issue":"3","key":"1945_CR1","doi-asserted-by":"publisher","first-page":"822","DOI":"10.1109\/TPWRD.2002.1022810","volume":"17","author":"Y Zhu","year":"2002","unstructured":"Y. Zhu, K. Tomsovic, Adaptive power flow method for distribution systems with dispersed generation. IEEE Trans. Power Delivery 17(3), 822\u2013915 (2002)","journal-title":"IEEE Trans. Power Delivery"},{"issue":"4","key":"1945_CR2","doi-asserted-by":"publisher","first-page":"1238","DOI":"10.1109\/TPWRS.2002.805012","volume":"17","author":"MJE Alam","year":"2002","unstructured":"M.J.E. Alam, K.M. Muttaqi, D. Sutanto, A three-phase power flow approach for integrated 3-wire MV and 4-wire multigrounded LV networks with rooftop solar PV. IEEE Trans. Power Syst. 17(4), 1238\u20131244 (2002)","journal-title":"IEEE Trans. Power Syst."},{"issue":"4","key":"1945_CR3","doi-asserted-by":"publisher","first-page":"1831","DOI":"10.1109\/TPWRS.2004.835659","volume":"19","author":"Z Wang","year":"2004","unstructured":"Z. Wang, F. Chen, J. Li, Implementing transformer nodal admittance matrices into backward\/forward sweep-based power flow analysis for unbalanced radial distribution system. IEEE Trans. Power Syst. 19(4), 1831\u20131836 (2004)","journal-title":"IEEE Trans. Power Syst."},{"issue":"115","key":"1945_CR4","first-page":"1163","volume":"8","author":"MA Laughton","year":"1968","unstructured":"M.A. Laughton, Analysis of unbalanced polyphase networks by the method of phase coordinates. Part 1: phase coordinates. Proc. IEE 8(115), 1163\u20131172 (1968)","journal-title":"Proc. IEE"},{"issue":"54","key":"1945_CR5","doi-asserted-by":"publisher","first-page":"83","DOI":"10.1016\/S0378-7796(99)00075-9","volume":"19","author":"TH Chen","year":"2000","unstructured":"T.H. Chen, W.C. Yang, T.Y. Guo, G.C. Pu, Modelling and analysis of asymmetrical three-phase distribution transformer banks with mid-tap connected to the secondary neutral conductor. Electric Power Syst. Res. 19(54), 83\u201389 (2000)","journal-title":"Electric Power Syst. Res."},{"key":"1945_CR6","doi-asserted-by":"crossref","unstructured":"T. Alinjak, I. Pavic, K. Trupinic, Improved three-phase power flow method for calculation of power losses in unbalanced radial distribution network, in 24th International Conference & Exhibition on Electricity Distribution (CIEED), Session 5: Planning of Power Distribution Systems, pp. 12\u201315, June, 2017.","DOI":"10.1049\/oap-cired.2017.0489"},{"issue":"2","key":"1945_CR7","doi-asserted-by":"publisher","first-page":"469","DOI":"10.1109\/TPWRS.2008.920184","volume":"23","author":"JA Peralta","year":"2008","unstructured":"J.A. Peralta, F. de Le\u00d3n, J. Mahseredjian, Unbalanced multiphase load-flow using a positive-sequence load-flow program. IEEE Trans. Syst. 23(2), 469\u2013476 (2008)","journal-title":"IEEE Trans. Syst."},{"key":"1945_CR8","volume-title":"Distribution Systems Modeling and Analysis","author":"W Kersting","year":"2002","unstructured":"W. Kersting, Distribution Systems Modeling and Analysis (CRC Press, Boca Raton, FL, 2002)."},{"issue":"4","key":"1945_CR9","doi-asserted-by":"publisher","first-page":"1671","DOI":"10.1109\/61.97706","volume":"6","author":"TH Chen","year":"1991","unstructured":"T.H. Chen, M.S. Chen, T. Inoue, P. Kotas, E.A. Chebli, Three-phase co-generator and transformer models for distribution system analysis. IEEE Trans. Power Del. 6(4), 1671\u20131681 (1991)","journal-title":"IEEE Trans. Power Del."},{"issue":"1","key":"1945_CR10","doi-asserted-by":"publisher","first-page":"169","DOI":"10.1109\/28.740861","volume":"35","author":"WH Kersting","year":"1998","unstructured":"W.H. Kersting, W.H. Phillips, W. Carr, A new approach to modeling three-phase transformer connections. IEEE Trans. Ind. Appl. 35(1), 169\u2013175 (1998)","journal-title":"IEEE Trans. Ind. Appl."},{"issue":"2","key":"1945_CR11","doi-asserted-by":"publisher","first-page":"663","DOI":"10.1109\/TPWRS.2011.2175256","volume":"27","author":"I Kocar","year":"2012","unstructured":"I. Kocar, J.S. Lacroix, Implementation of a modified augmented nodal analysis based transformer model in the backward forward sweep solver. IEEE Trans. Power Syst. 27(2), 663\u2013670 (2012)","journal-title":"IEEE Trans. Power Syst."},{"issue":"4","key":"1945_CR12","doi-asserted-by":"publisher","first-page":"3843","DOI":"10.1049\/iet-gtd.2016.2080","volume":"11","author":"M Coppo","year":"2017","unstructured":"M. Coppo, F. Bignucolo, R. Turri, Generalized transformer modeling for power flow calculation in multi-phase unbalanced networks. IET Gener. Transm. Distrib. 11(4), 3843\u20133852 (2017)","journal-title":"IET Gener. Transm. Distrib."},{"issue":"3","key":"1945_CR13","doi-asserted-by":"publisher","first-page":"975","DOI":"10.1109\/59.119237","volume":"6","author":"WH Kersting","year":"1991","unstructured":"W.H. Kersting, Radial distribution test feeders. IEEE Trans. Power Syst. 6(3), 975\u2013985 (1991)","journal-title":"IEEE Trans. Power Syst."}],"container-title":["EURASIP Journal on Wireless Communications and Networking"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1186\/s13638-021-01945-z.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1186\/s13638-021-01945-z\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1186\/s13638-021-01945-z.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,3,25]],"date-time":"2021-03-25T18:07:39Z","timestamp":1616695659000},"score":1,"resource":{"primary":{"URL":"https:\/\/jwcn-eurasipjournals.springeropen.com\/articles\/10.1186\/s13638-021-01945-z"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,3,25]]},"references-count":13,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2021,12]]}},"alternative-id":["1945"],"URL":"https:\/\/doi.org\/10.1186\/s13638-021-01945-z","relation":{"has-preprint":[{"id-type":"doi","id":"10.21203\/rs.3.rs-125904\/v1","asserted-by":"object"}]},"ISSN":["1687-1499"],"issn-type":[{"value":"1687-1499","type":"electronic"}],"subject":[],"published":{"date-parts":[[2021,3,25]]},"assertion":[{"value":"6 December 2020","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"9 March 2021","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"25 March 2021","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The authors declare that they have no competing interests.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"66"}}