{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,1]],"date-time":"2025-10-01T15:31:02Z","timestamp":1759332662115},"reference-count":33,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2017,12,1]],"date-time":"2017-12-01T00:00:00Z","timestamp":1512086400000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"name":"Tianjin Research Program of Application Foundation and Advanced Technology","award":["16JCYBJC28800,13JCYBJC15600"],"award-info":[{"award-number":["16JCYBJC28800,13JCYBJC15600"]}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["J Image Video Proc."],"published-print":{"date-parts":[[2017,12]]},"DOI":"10.1186\/s13640-017-0234-x","type":"journal-article","created":{"date-parts":[[2017,12,13]],"date-time":"2017-12-13T13:33:17Z","timestamp":1513171997000},"update-policy":"http:\/\/dx.doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":6,"title":["Variational Bayesian blind restoration reconstruction based on shear wave transform for low-dose medical CT image"],"prefix":"10.1186","volume":"2017","author":[{"given":"Yunshan","family":"Sun","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Liyi","family":"Zhang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Teng","family":"Fei","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Xiaopei","family":"Liu","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2017,12,13]]},"reference":[{"key":"234_CR1","doi-asserted-by":"crossref","unstructured":"RW Harbron, EA Ainsbury, SD Bouffler, et al., Enhanced radiation dose and DNA damage associated with iodinated contrast media in diagnostic x-ray imaging. Br. J. Radiol. 90(1079), 20170028 (2017)","DOI":"10.1259\/bjr.20170028"},{"issue":"6","key":"234_CR2","doi-asserted-by":"crossref","first-page":"3314","DOI":"10.1118\/1.4955539","volume":"43","author":"S Mein","year":"2016","unstructured":"S Mein, R Gunasingha, M Nolan, et al., SU-C-204-06: Monte Carlo dose calculation for kilovoltage X-ray-psoralen activated cancer therapy (X-PACT): preliminary results. Med. Phys. 43(6), 3314\u20133315 (2016)","journal-title":"Med. Phys."},{"issue":"3","key":"234_CR3","doi-asserted-by":"crossref","first-page":"363","DOI":"10.1093\/jrr\/rrw088","volume":"58","author":"M Tamura","year":"2017","unstructured":"M Tamura, H Sakurai, M Mizumoto, et al., Lifetime attributable risk of radiation-induced secondary cancer from proton beam therapy compared with that of intensity-modulated X-ray therapy in randomly sampled pediatric cancer patients. J. Radiat. Res. 58(3), 363\u2013371 (2017)","journal-title":"J. Radiat. Res."},{"issue":"13","key":"234_CR4","doi-asserted-by":"crossref","first-page":"3510","DOI":"10.1109\/TSP.2017.2691661","volume":"65","author":"R Gu","year":"2017","unstructured":"R Gu, A Dogand\u017ei\u0107, Projected Nesterov\u2019s proximal-gradient algorithm for sparse signal recovery. IEEE Trans. Signal Process. 65(13), 3510\u20133525 (2017)","journal-title":"IEEE Trans. Signal Process."},{"issue":"2","key":"234_CR5","doi-asserted-by":"crossref","first-page":"171","DOI":"10.1049\/iet-spr.2016.0272","volume":"11","author":"C Liu","year":"2017","unstructured":"C Liu, J Wang, W Wang, et al., Non-convex block-sparse compressed sensing with redundant dictionaries. IET Signal Proc. 11(2), 171\u2013180 (2017)","journal-title":"IET Signal Proc."},{"issue":"17","key":"234_CR6","doi-asserted-by":"crossref","first-page":"4777","DOI":"10.1088\/0031-9155\/53\/17\/021","volume":"53","author":"EY Sidky","year":"2008","unstructured":"EY Sidky, X Pan, Image reconstruction in circular cone-beam computed tomography by constrained, total-variation minimization. Phys. Med. Biol. 53(17), 4777\u20134807 (2008)","journal-title":"Phys. Med. Biol."},{"issue":"3","key":"234_CR7","doi-asserted-by":"crossref","first-page":"616","DOI":"10.1109\/JETCAS.2012.2221530","volume":"2","author":"J Chen","year":"2012","unstructured":"J Chen, J Cong, LA Vese, et al., A hybrid architecture for compressive sensing 3-D CT reconstruction. IEEE J. Emerging Sel. Top. Circuits Syst. 2(3), 616\u2013625 (2012)","journal-title":"IEEE J. Emerging Sel. Top. Circuits Syst."},{"issue":"5","key":"234_CR8","doi-asserted-by":"crossref","first-page":"3305","DOI":"10.1109\/TNS.2013.2275994","volume":"60","author":"B Vandeghinste","year":"2013","unstructured":"B Vandeghinste, B Goossens, RV Holen, et al., Iterative CT reconstruction using shearlet-based regularization. IEEE Trans. Nucl. Sci. 60(5), 3305\u20133317 (2013)","journal-title":"IEEE Trans. Nucl. Sci."},{"key":"234_CR9","doi-asserted-by":"crossref","first-page":"785","DOI":"10.1016\/j.ijleo.2016.11.186","volume":"131","author":"H Zhang","year":"2017","unstructured":"H Zhang, L Zhang, Y Sun, et al., Low dose CT image statistical iterative reconstruction algorithms based on off-line dictionary sparse representation. Optik-Int. J Light Electron Opt. 131, 785\u2013797 (2017)","journal-title":"Optik-Int. J Light Electron Opt."},{"issue":"1","key":"234_CR10","doi-asserted-by":"crossref","first-page":"142","DOI":"10.1109\/TMI.2016.2600249","volume":"36","author":"Y Zhang","year":"2016","unstructured":"Y Zhang, X Mou, G Wang, et al., Tensor-based dictionary learning for spectral CT reconstruction. IEEE Trans. Med. Imaging 36(1), 142\u2013154 (2016)","journal-title":"IEEE Trans. Med. Imaging"},{"issue":"19\u201320","key":"234_CR11","first-page":"815","volume":"127","author":"M Pienn","year":"2015","unstructured":"M Pienn, K Bredies, R Stollberger, et al., Denoising algorithm for quantitative assessment of thoracic dual-energy computed tomography images. Wien. Klin. Wochenschr. 127(19\u201320), 815\u2013815 (2015)","journal-title":"Wien. Klin. Wochenschr."},{"issue":"9","key":"234_CR12","doi-asserted-by":"crossref","first-page":"5145","DOI":"10.1109\/TIT.2016.2587772","volume":"62","author":"ME Lopes","year":"2016","unstructured":"ME Lopes, Unknown sparsity in compressed sensing: denoising and inference. IEEE Trans. Inf. Theory 62(9), 5145\u20135166 (2016)","journal-title":"IEEE Trans. Inf. Theory"},{"issue":"3","key":"234_CR13","first-page":"456","volume":"29","author":"B Xing","year":"2012","unstructured":"B Xing, J Wang, Denoising of medical CT image based on sparse decomposition. J. Biomed. Eng. 29(3), 456\u2013459 (2012)","journal-title":"J. Biomed. Eng."},{"issue":"5","key":"234_CR14","first-page":"864","volume":"42","author":"Y Zhu","year":"2012","unstructured":"Y Zhu, L Luo, Toumoulin. Dictionary learning based denoising of low-dose X-ray CT image. J. Southeast Univ. 42(5), 864\u2013868 (2012)","journal-title":"J. Southeast Univ."},{"issue":"7","key":"234_CR15","doi-asserted-by":"crossref","first-page":"2039","DOI":"10.1007\/s00330-015-4044-1","volume":"26","author":"P Bannas","year":"2016","unstructured":"P Bannas, Y Li, U Motosugi, et al., Prior image constrained compressed sensing metal artifact reduction (PICCS-MAR): 2D and 3D image quality improvement with hip prostheses at CT colonography. Eur. Radiol. 26(7), 2039\u20132046 (2016)","journal-title":"Eur. Radiol."},{"key":"234_CR16","doi-asserted-by":"crossref","first-page":"583","DOI":"10.1016\/j.apenergy.2015.12.058","volume":"165","author":"T Yang","year":"2016","unstructured":"T Yang, H Pen, D Wang, et al., Harmonic analysis in integrated energy system based on compressed sensing. Appl. Energy 165, 583\u2013591 (2016)","journal-title":"Appl. Energy"},{"issue":"13","key":"234_CR17","doi-asserted-by":"crossref","first-page":"3905","DOI":"10.1088\/0031-9155\/55\/13\/022","volume":"55","author":"H Yu","year":"2010","unstructured":"H Yu, GA Wang, Soft-threshold filtering approach for reconstruction from a limited number of projections. Phys. Med. Biol. 55(13), 3905\u20133916 (2010)","journal-title":"Phys. Med. Biol."},{"issue":"10","key":"234_CR18","doi-asserted-by":"crossref","first-page":"e109345","DOI":"10.1371\/journal.pone.0109345","volume":"9","author":"W Yu","year":"2014","unstructured":"W Yu, LA Zeng, Novel weighted total difference based image reconstruction algorithm for few-view computed tomography. PLoS One 9(10), e109345 (2014)","journal-title":"PLoS One"},{"key":"234_CR19","first-page":"2043","volume":"373","author":"T Blumensath","year":"2015","unstructured":"T Blumensath, R Boardman, Non-convexly constrained image reconstruction from nonlinear tomographic X-ray measurements. Philos. Trans. 373, 2043\u20132061 (2015)","journal-title":"Philos. Trans."},{"issue":"6","key":"234_CR20","doi-asserted-by":"crossref","first-page":"1378","DOI":"10.1109\/TMI.2015.2394476","volume":"34","author":"G Zhang","year":"2015","unstructured":"G Zhang, H Pu, W He, et al., Bayesian framework based direct reconstruction of fluorescence parametric images. IEEE Trans. Med. Imaging 34(6), 1378\u20131391 (2015)","journal-title":"IEEE Trans. Med. Imaging"},{"issue":"6","key":"234_CR21","doi-asserted-by":"crossref","first-page":"423","DOI":"10.1016\/j.compmedimag.2014.05.002","volume":"38","author":"H Zhang","year":"2014","unstructured":"H Zhang, J Ma, J Wang, et al., Statistical image reconstruction for low-dose CT using nonlocal means-based regularization. Comput. Med. Imaging Graph. 38(6), 423\u2013435 (2014)","journal-title":"Comput. Med. Imaging Graph."},{"issue":"3","key":"234_CR22","first-page":"499","volume":"44","author":"Q Zhang","year":"2014","unstructured":"Q Zhang, L Luo, Z Gui, Improved nonlocal prior-based Bayesian sinogram smoothing algorithm for low-dose CT. J. Southeast Univ. 44(3), 499\u2013503 (2014)","journal-title":"J. Southeast Univ."},{"issue":"11","key":"234_CR23","first-page":"1161","volume":"40","author":"C Cai","year":"2013","unstructured":"C Cai, T Rodet, S Legoupil, et al., A full-spectral Bayesian reconstruction approach based on the material decomposition model applied in dual-energy computed tomography. Med. Phys. 40(11), 1161\u20131163 (2013)","journal-title":"Med. Phys."},{"issue":"17","key":"234_CR24","doi-asserted-by":"crossref","first-page":"2811","DOI":"10.1016\/j.ijleo.2012.08.045","volume":"124","author":"Q Zhang","year":"2013","unstructured":"Q Zhang, Z Gui, Y Chen, et al., Bayesian sinogram smoothing with an anisotropic diffusion weighted prior for low-dose X-ray computed tomography. Optik-Int. J. Light Electron Opt. 124(17), 2811\u20132816 (2013)","journal-title":"Optik-Int. J. Light Electron Opt."},{"issue":"4","key":"234_CR25","doi-asserted-by":"crossref","first-page":"1173","DOI":"10.1088\/0031-9155\/56\/4\/018","volume":"56","author":"Y Hu","year":"2011","unstructured":"Y Hu, L Xie, L Luo, et al., L0 constrained sparse reconstruction for multi-slice helical CT reconstruction. Phys. Med. Biol. 56(4), 1173\u20131189 (2011)","journal-title":"Phys. Med. Biol."},{"issue":"7","key":"234_CR26","doi-asserted-by":"crossref","first-page":"837","DOI":"10.1109\/TMI.2003.815075","volume":"22","author":"M Jiang","year":"2003","unstructured":"M Jiang, G Wang, MW Skinner, et al., Blind deblurring of spiral CT images. IEEE Trans. Med. Imaging 22(7), 837\u2013845 (2003)","journal-title":"IEEE Trans. Med. Imaging"},{"issue":"8","key":"234_CR27","doi-asserted-by":"crossref","first-page":"1528","DOI":"10.1109\/TMI.2010.2048335","volume":"29","author":"J Xu","year":"2010","unstructured":"J Xu, K Taguchi, BM Tsui, Statistical projection completion in X-ray CT using consistency conditions. IEEE Trans. Med. Imaging 29(8), 1528\u20131540 (2010)","journal-title":"IEEE Trans. Med. Imaging"},{"issue":"3","key":"234_CR28","doi-asserted-by":"crossref","first-page":"1022","DOI":"10.1109\/TBME.2007.909531","volume":"55","author":"J Wang","year":"2008","unstructured":"J Wang, HB Lu, JH Wen, et al., Multiscale penalized weighted least-squares sinogram restoration for low-dose X-ray computed tomography. IEEE Trans. Biomed. Eng. 55(3), 1022\u20131031 (2008)","journal-title":"IEEE Trans. Biomed. Eng."},{"issue":"2","key":"234_CR29","doi-asserted-by":"crossref","first-page":"190","DOI":"10.1109\/TMI.2006.889705","volume":"26","author":"J You","year":"2007","unstructured":"J You, GL Zeng, Hilbert transform based FBP algorithm for fan-beam CT full and partial scans. IEEE Trans. Med. Imaging 26(2), 190\u2013199 (2007)","journal-title":"IEEE Trans. Med. Imaging"},{"issue":"8","key":"234_CR30","doi-asserted-by":"crossref","first-page":"957","DOI":"10.1109\/TIP.2003.815295","volume":"12","author":"M Jiang","year":"2003","unstructured":"M Jiang, G Wang, Convergence of the simultaneous algebraic reconstruction technique (SART). IEEE Trans. Image Process. 12(8), 957 (2003)","journal-title":"IEEE Trans. Image Process."},{"issue":"5","key":"234_CR31","doi-asserted-by":"crossref","first-page":"5368","DOI":"10.1364\/OE.23.005368","volume":"23","author":"X Yang","year":"2015","unstructured":"X Yang, R Hofmann, R Dapp, et al., TV-based conjugate gradient method and discrete L-curve for few-view CT reconstruction of X-ray in vivo data. Opt. Express 23(5), 5368\u20135387 (2015)","journal-title":"Opt. Express"},{"issue":"1","key":"234_CR32","first-page":"1","volume":"3","author":"AYA Yusra","year":"2012","unstructured":"AYA Yusra, CS Der, Comparison of image quality assessment: PSNR, HVS, SSIM, UIQI. Int. J. Sci. Eng. 3(1), 1\u20135 (2012)","journal-title":"Int. J. Sci. Eng."},{"issue":"4","key":"234_CR33","doi-asserted-by":"crossref","first-page":"600","DOI":"10.1109\/TIP.2003.819861","volume":"13","author":"Z Wang","year":"2004","unstructured":"Z Wang, AC Bovik, HR Sheikh, et al., Image quality assessment: from error visibility to structural similarity. IEEE Trans. Image Process. 13(4), 600\u2013612 (2004)","journal-title":"IEEE Trans. Image Process."}],"container-title":["EURASIP Journal on Image and Video Processing"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1186\/s13640-017-0234-x.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1186\/s13640-017-0234-x\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1186\/s13640-017-0234-x.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2020,10,24]],"date-time":"2020-10-24T07:25:47Z","timestamp":1603524347000},"score":1,"resource":{"primary":{"URL":"https:\/\/jivp-eurasipjournals.springeropen.com\/articles\/10.1186\/s13640-017-0234-x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2017,12]]},"references-count":33,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2017,12]]}},"alternative-id":["234"],"URL":"https:\/\/doi.org\/10.1186\/s13640-017-0234-x","relation":{},"ISSN":["1687-5281"],"issn-type":[{"value":"1687-5281","type":"electronic"}],"subject":[],"published":{"date-parts":[[2017,12]]},"article-number":"84"}}