{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,9]],"date-time":"2026-05-09T04:03:20Z","timestamp":1778299400548,"version":"3.51.4"},"reference-count":26,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2019,11,12]],"date-time":"2019-11-12T00:00:00Z","timestamp":1573516800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2019,11,12]],"date-time":"2019-11-12T00:00:00Z","timestamp":1573516800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/100000070","name":"National Institute of Biomedical Imaging and Bioengineering","doi-asserted-by":"publisher","award":["NIH R15EB024283"],"award-info":[{"award-number":["NIH R15EB024283"]}],"id":[{"id":"10.13039\/100000070","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Vis. Comput. Ind. Biomed. Art"],"published-print":{"date-parts":[[2019,12]]},"abstract":"<jats:title>Abstract<\/jats:title>\n<jats:p>Sparse-view tomography has many applications such as in low-dose computed tomography (CT). Using under-sampled data, a perfect image is not expected. The goal of this paper is to obtain a tomographic image that is better than the na\u00efve filtered backprojection (FBP) reconstruction that uses linear interpolation to complete the measurements. This paper proposes a method to estimate the un-measured projections by displacement function interpolation. Displacement function estimation is a non-linear procedure and the linear interpolation is performed on the displacement function (instead of, on the sinogram itself). As a result, the estimated measurements are not the linear transformation of the measured data. The proposed method is compared with the linear interpolation methods, and the proposed method shows superior performance.<\/jats:p>","DOI":"10.1186\/s42492-019-0024-7","type":"journal-article","created":{"date-parts":[[2019,11,12]],"date-time":"2019-11-12T00:04:19Z","timestamp":1573517059000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":8,"title":["Sparse-view tomography via displacement function interpolation"],"prefix":"10.1186","volume":"2","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-0790-6043","authenticated-orcid":false,"given":"Gengsheng L.","family":"Zeng","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2019,11,12]]},"reference":[{"issue":"1","key":"24_CR1","doi-asserted-by":"publisher","first-page":"27","DOI":"10.1016\/j.rcl.2008.10.006","volume":"47","author":"CH McCollough","year":"2009","unstructured":"McCollough CH, Primak AN, Braun N, Kofler J, Yu L, Christner J (2009) Strategies for reducing radiation dose in CT. Radiol Clin N Am 47(1):27\u201340. https:\/\/doi.org\/10.1016\/j.rcl.2008.10.006","journal-title":"Radiol Clin N Am"},{"key":"24_CR2","doi-asserted-by":"publisher","first-page":"466","DOI":"10.1002\/jmri.21585","volume":"29","author":"G Adluru","year":"2009","unstructured":"Adluru G, McGann C, Speier P, Kholmovski E, Shaaban A, Dibella E (2009) Acquisition and reconstruction of undersampled radial data for myocardial perfusion magnetic resonance imaging. J Magn Reson Imaging 29:466\u2013473. https:\/\/doi.org\/10.1002\/jmri.21585","journal-title":"J Magn Reson Imaging"},{"key":"24_CR3","volume-title":"Computed tomography: from photon statistics to modern cone-beam CT","author":"TM Buzug","year":"2010","unstructured":"Buzug TM (2010) Computed tomography: from photon statistics to modern cone-beam CT. Springer-Verlag, Berlin Heidelberg"},{"key":"24_CR4","doi-asserted-by":"publisher","first-page":"225","DOI":"10.1007\/978-0-8176-8212-5_9","volume-title":"Sampling, Wavelets, and Tomography","author":"Adel Faridani","year":"2004","unstructured":"Faridani A (2004) Sampling Theory and Parallel-Beam Tomography. In: Benedetto JJ, Zayed AI, (eds) Sampling, Wavelets, and Tomography. Applied and Numerical Harmonic Analysis. Birkh\u00e4user, Boston, MA. https:\/\/doi.org\/10.1007\/978-0-8176-8212-5_9"},{"key":"24_CR5","doi-asserted-by":"publisher","unstructured":"Faridani A (2006) Fan-beam tomography and sampling theory. Proceedings of Symposia in Applied Mathematics. 63. https:\/\/doi.org\/10.1090\/psapm\/063\/2208236","DOI":"10.1090\/psapm\/063\/2208236"},{"key":"24_CR6","doi-asserted-by":"publisher","unstructured":"Natterer F (2001) The Mathematics of Computerized Tomography. Society for Industrial and Applied Mathematics. https:\/\/doi.org\/10.1137\/1.9780898719284","DOI":"10.1137\/1.9780898719284"},{"issue":"2","key":"24_CR7","doi-asserted-by":"publisher","first-page":"358","DOI":"10.1137\/0153021","volume":"53","author":"F Natterer","year":"1993","unstructured":"Natterer F (1993) Sampling in fan-beam tomography. SIAM J Appl Math 53(2):358\u2013380","journal-title":"SIAM J Appl Math"},{"issue":"5","key":"24_CR8","doi-asserted-by":"publisher","first-page":"994","DOI":"10.1109\/TASSP.1981.1163686","volume":"29","author":"P Rattey","year":"1981","unstructured":"Rattey P, Lindgren A (1981) Sampling the 2-D radon transform. IEEE Trans ASSP 29(5):994\u20131002","journal-title":"IEEE Trans ASSP"},{"issue":"17","key":"24_CR9","doi-asserted-by":"publisher","first-page":"4777","DOI":"10.1088\/0031-9155\/53\/17\/021","volume":"53","author":"EY Sidky","year":"2008","unstructured":"Sidky EY, Pan X (2008) Image reconstruction in circular cone-beam computed tomography by constrained, total-variation minimization. Phys Med Biol 53(17):4777\u20134807","journal-title":"Phys Med Biol"},{"issue":"1","key":"24_CR10","doi-asserted-by":"crossref","first-page":"71","DOI":"10.3233\/XST-130367","volume":"21","author":"S Abbas","year":"2013","unstructured":"Abbas S, Min J, Cho S (2013) Super-sparsely view-sampled cone-beam CT by incorporating prior data. J X-Ray Sci Technol 21(1):71\u201383","journal-title":"J X-Ray Sci Technol"},{"issue":"11","key":"24_CR11","doi-asserted-by":"publisher","first-page":"e79709","DOI":"10.1371\/journal.pone.0079709","volume":"8","author":"J Huang","year":"2013","unstructured":"Huang J, Zhang Y, Ma J, Zeng D, Bian Z, Niu S, Feng Q, Liang Z, Chen W (2013) Iterative image reconstruction for sparse-view CT using normal-dose image induced total variation prior. PLoS One 8(11):e79709","journal-title":"PLoS One"},{"issue":"2","key":"24_CR12","doi-asserted-by":"publisher","first-page":"585","DOI":"10.1109\/TNS.2018.2888948","volume":"66","author":"Z Zheng","year":"2019","unstructured":"Zheng Z, Hu Y, Cai A, Zhang W, Li J, Yan B, Hu G (2019) Few-view computed tomography image reconstruction using mean curvature model with curvature smoothing and surface fitting. IEEE Trans Nucl Sci 66(2):585\u2013596. https:\/\/doi.org\/10.1109\/TNS.2018.2888948","journal-title":"IEEE Trans Nucl Sci"},{"key":"24_CR13","doi-asserted-by":"publisher","first-page":"98","DOI":"10.1016\/j.ndteint.2017.09.002","volume":"93","author":"GA Jones","year":"2018","unstructured":"Jones GA, Huthwaite P (2018) Limited view X-ray tomography for dimensional measurements. NDT & E Int 93:98\u2013109. https:\/\/doi.org\/10.1016\/j.ndteint.2017.09.002","journal-title":"NDT & E Int"},{"issue":"4","key":"24_CR14","doi-asserted-by":"publisher","first-page":"043006","DOI":"10.1117\/1.JEI.27.4.043006","volume":"27","author":"VV Vlasov","year":"2018","unstructured":"Vlasov VV, Konovalov AB, Kolchugin SV (2018) Hybrid algorithm for few-views computed tomography of strongly absorbing media: algebraic reconstruction, TV-regularization, and adaptive segmentation. J Electron Imag 27(4):043006. https:\/\/doi.org\/10.1117\/1.JEI.27.4.043006","journal-title":"J Electron Imag"},{"key":"24_CR15","doi-asserted-by":"publisher","first-page":"171","DOI":"10.1186\/s12859-018-2169-3","volume":"19","author":"C de Molina","year":"2018","unstructured":"de Molina C, Serrano E, Garcia-Blas J, Carretero J, Desco M, Abella M (2018) GPU-accelerated iterative reconstruction for limited-data tomography in CBCT systems. BMC Bioinformatics 19:171. https:\/\/doi.org\/10.1186\/s12859-018-2169-3","journal-title":"BMC Bioinformatics"},{"issue":"5","key":"24_CR16","doi-asserted-by":"publisher","first-page":"577","DOI":"10.1097\/00004728-197811000-00010","volume":"2","author":"RA Brooks","year":"1978","unstructured":"Brooks RA, Weiss GH, Talbert AJ (1978) A new approach to interpolation in computed tomography. J Comput Assist Tomography 2(5):577\u2013585","journal-title":"J Comput Assist Tomography"},{"issue":"1","key":"24_CR17","doi-asserted-by":"publisher","first-page":"423","DOI":"10.4236\/am.2014.53043","volume":"5","author":"S Siltanen","year":"2014","unstructured":"Siltanen S, Kalke M (2014) Sinogram interpolation method for sparse-angle tomography. Appl Math 5(1):423\u2013441. https:\/\/doi.org\/10.4236\/am.2014.53043","journal-title":"Appl Math"},{"key":"24_CR18","doi-asserted-by":"publisher","first-page":"1011","DOI":"10.1109\/TMI.2008.2011550","volume":"28","author":"M Bertram","year":"2009","unstructured":"Bertram M, Wiegert J, Schafer D, Aach T, Rose G (2009) Directional view interpolation for compensation of sparse angular sampling in cone-beam CT. IEEE Trans Med Imaging 28:1011\u20131022","journal-title":"IEEE Trans Med Imaging"},{"key":"24_CR19","first-page":"481","volume":"21","author":"H Zhang","year":"2013","unstructured":"Zhang H, Sonke J-J (2013) Directional sinogram interpolation for sparse angular acquisition in cone-beam computed tomography. J Xray Sci Technol 21:481\u2013496","journal-title":"J Xray Sci Technol"},{"issue":"2","key":"24_CR20","doi-asserted-by":"publisher","first-page":"109","DOI":"10.1109\/TRPMS.2018.2867611","volume":"3","author":"H Lee","year":"2019","unstructured":"Lee H, Lee J, Kim H, Cho B, Cho S (2019) Deep-neural-network based sinogram synthesis for sparse-view CT image reconstruction. IEEE Trans Rad Plasma Med Sci 3(2):109\u2013119","journal-title":"IEEE Trans Rad Plasma Med Sci"},{"key":"24_CR21","doi-asserted-by":"publisher","first-page":"105731K","DOI":"10.1117\/12.2293319","volume":"10573","author":"K Liang","year":"2018","unstructured":"Liang K, Yang H, Kang K, Xing Y (2018) Improve angular resolution for sparse-view CT with residual convolutional neural network. Proc SPIE Med Imag 10573:105731K. https:\/\/doi.org\/10.1117\/12.2293319","journal-title":"Proc SPIE Med Imag"},{"issue":"1","key":"24_CR22","doi-asserted-by":"publisher","first-page":"104","DOI":"10.1002\/mp.13258","volume":"46","author":"D Lee","year":"2018","unstructured":"Lee D, Choi S, Kim H-J (2018) High quality imaging from sparsely sampled computed tomography data with deep learning and wavelet transform in various domains. Med Phys 46(1):104\u2013115. https:\/\/doi.org\/10.1002\/mp.13258","journal-title":"Med Phys"},{"issue":"9","key":"24_CR23","doi-asserted-by":"publisher","first-page":"1065","DOI":"10.1109\/TMI.2004.828681","volume":"23","author":"A Rao","year":"2004","unstructured":"Rao A, Chandrashekara R, Sanchez-Ortiz GI, Mohiaddin R, Aljabar P, Hajnal JV, Puri BK, Rueckert D (2004) Spatial transformation of motion and deformation fields using nonrigid registration. IEEE Trans Med Imaging 23(9):1065\u20131076","journal-title":"IEEE Trans Med Imaging"},{"issue":"3","key":"24_CR24","doi-asserted-by":"publisher","first-page":"243","DOI":"10.1016\/S1361-8415(98)80022-4","volume":"2","author":"JP Thirion","year":"1998","unstructured":"Thirion JP (1998) Image matching as a diffusion process: an analogy with Maxwell\u2019s demons. Med Image Anal 2(3):243\u2013260","journal-title":"Med Image Anal"},{"key":"24_CR25","doi-asserted-by":"publisher","first-page":"2887","DOI":"10.1088\/0031-9155\/50\/12\/011","volume":"50","author":"H Wang","year":"2005","unstructured":"Wang H, Dong L, O\u2019Daniel J, Mohan R, Garden AS, Ang KK, Kuban DA, Bonnen M, Chang JY, Cheung R (2005) Validation of an accelerated \u2018demons\u2019 algorithm for deformable image registration in radiation therapy. Phys Med Biol 50:2887\u20132905","journal-title":"Phys Med Biol"},{"key":"24_CR26","doi-asserted-by":"publisher","first-page":"615","DOI":"10.2307\/2372313","volume":"73","author":"L Landweber","year":"1951","unstructured":"Landweber L (1951) An iteration formula for Fredholm integral equations of the first kind. Am J Math 73:615\u2013624","journal-title":"Am J Math"}],"container-title":["Visual Computing for Industry, Biomedicine, and Art"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1186\/s42492-019-0024-7.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1186\/s42492-019-0024-7\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1186\/s42492-019-0024-7.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2020,11,11]],"date-time":"2020-11-11T00:08:32Z","timestamp":1605053312000},"score":1,"resource":{"primary":{"URL":"https:\/\/vciba.springeropen.com\/articles\/10.1186\/s42492-019-0024-7"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,11,12]]},"references-count":26,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2019,12]]}},"alternative-id":["24"],"URL":"https:\/\/doi.org\/10.1186\/s42492-019-0024-7","relation":{},"ISSN":["2524-4442"],"issn-type":[{"value":"2524-4442","type":"electronic"}],"subject":[],"published":{"date-parts":[[2019,11,12]]},"assertion":[{"value":"12 August 2019","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"9 October 2019","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"12 November 2019","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The authors declare that they have no competing interests.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"13"}}