{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,15]],"date-time":"2026-01-15T10:54:57Z","timestamp":1768474497551,"version":"3.49.0"},"reference-count":19,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2020,4,29]],"date-time":"2020-04-29T00:00:00Z","timestamp":1588118400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2020,4,29]],"date-time":"2020-04-29T00:00:00Z","timestamp":1588118400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Vis. Comput. Ind. Biomed. Art"],"published-print":{"date-parts":[[2020,12]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:p>Image reconstruction for list-mode time-of-flight (TOF) positron emission tomography (PET) can be achieved by analytic algorithms. The backprojection filtering (BPF) algorithm is an efficient algorithm for this task. The conventional noise control method for analytic image reconstruction is the use of a stationary lowpass filter, which does not model the Poisson noise properly. This study proposes a nonstationary filter for Poisson noise control. The filter is implemented in the spatial domain in a form similar to convolution.<\/jats:p>","DOI":"10.1186\/s42492-020-00048-8","type":"journal-article","created":{"date-parts":[[2020,4,29]],"date-time":"2020-04-29T06:02:54Z","timestamp":1588140174000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":3,"title":["Poisson-noise weighted filter for time-of-flight positron emission tomography"],"prefix":"10.1186","volume":"3","author":[{"given":"Gengsheng L.","family":"Zeng","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Li","family":"Lv","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Qiu","family":"Huang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2020,4,29]]},"reference":[{"issue":"6","key":"48_CR1","doi-asserted-by":"publisher","first-page":"4581","DOI":"10.1109\/TNS.1981.4335769","volume":"28","author":"T Tomitani","year":"1981","unstructured":"Tomitani T (1981) Image reconstruction and noise evaluation in photon time-of-flight assisted positron emission tomography. IEEE Trans Nucl Sci 28(6):4581\u20134589. https:\/\/doi.org\/10.1109\/TNS.1981.4335769","journal-title":"IEEE Trans Nucl Sci"},{"key":"48_CR2","doi-asserted-by":"publisher","first-page":"4507","DOI":"10.1088\/0031-9155\/50\/19\/006","volume":"50","author":"M Conti","year":"2005","unstructured":"Conti M, Bendriem B, Casey M, Chen M, Kehren F, Michel C et al (2005) First experimental results of time-of-flight reconstruction on an LSO PET scanner. Phys Med Biol 50:4507\u20134526. https:\/\/doi.org\/10.1088\/0031-9155\/50\/19\/006","journal-title":"Phys Med Biol"},{"key":"48_CR3","doi-asserted-by":"publisher","first-page":"22","DOI":"10.1186\/s42492-019-0035-4","volume":"2","author":"GL Zeng","year":"2019","unstructured":"Zeng GL, Li Y, Huang Q (2019) Analytic time-of-flight positron emission tomography reconstruction: two-dimensional case. Visual Comput Ind Biomed Art 2:22. https:\/\/doi.org\/10.1186\/s42492-019-0035-4","journal-title":"Visual Comput Ind Biomed Art"},{"key":"48_CR4","doi-asserted-by":"publisher","first-page":"5","DOI":"10.1186\/s42492-020-0042-5","volume":"3","author":"GL Zeng","year":"2020","unstructured":"Zeng GL, Li Y, Huang Q (2020) Analytic time-of-flight positron emission tomography reconstruction: three-dimensional case. Visual Comput Ind Biomed Art 3:5. https:\/\/doi.org\/10.1186\/s42492-020-0042-5","journal-title":"Visual Comput Ind Biomed Art"},{"key":"48_CR5","volume-title":"Digital image processing","author":"RC Gonzalez","year":"2018","unstructured":"Gonzalez RC, Woods RE (2018) Digital image processing, 4th edn. Pearson, New York","edition":"4"},{"key":"48_CR6","volume-title":"Medical image reconstruction: a conceptual tutorial","author":"GL Zeng","year":"2009","unstructured":"Zeng GL (2009) Medical image reconstruction: a conceptual tutorial. Springer, London"},{"issue":"3","key":"48_CR7","doi-asserted-by":"publisher","first-page":"21","DOI":"10.1109\/TNS.1974.6499235","volume":"21","author":"LA Shepp","year":"1974","unstructured":"Shepp LA, Logan BF (1974) The Fourier reconstruction of a head section. IEEE Trans Nucl Sci 21(3):21\u201343. https:\/\/doi.org\/10.1109\/TNS.1974.6499235","journal-title":"IEEE Trans Nucl Sci"},{"key":"48_CR8","doi-asserted-by":"publisher","DOI":"10.1016\/C2009-0-51635-2","volume-title":"Physics in nuclear medicine","author":"SR Cherry","year":"2012","unstructured":"Cherry SR, Sorenson JA, Phelps ME (2012) Physics in nuclear medicine, 4th edn. Elsevier Inc., Philadelphia. https:\/\/doi.org\/10.1016\/C2009-0-51635-2","edition":"4"},{"key":"48_CR9","volume-title":"Computed tomography: principles, design, artifacts, and recent advances","author":"J Hsieh","year":"2003","unstructured":"Hsieh J (2003) Computed tomography: principles, design, artifacts, and recent advances. SPIE Press, Washington"},{"issue":"1","key":"48_CR10","doi-asserted-by":"publisher","first-page":"64","DOI":"10.1109\/TUFFC.2006.1588392","volume":"53","author":"OV Michailovich","year":"2006","unstructured":"Michailovich OV, Tannenbaum A (2006) Despeckling of medical ultrasound images. IEEE Trans Ultrason Ferroelectr Freq Control 53(1):64\u201378. https:\/\/doi.org\/10.1109\/TUFFC.2006.1588392","journal-title":"IEEE Trans Ultrason Ferroelectr Freq Control"},{"issue":"1","key":"48_CR11","doi-asserted-by":"publisher","first-page":"21","DOI":"10.1073\/pnas.1311868111","volume":"111","author":"M Nasiriavanaki","year":"2014","unstructured":"Nasiriavanaki M, Xia J, Wan HL, Bauer AQ, Culver JP, Wang LV (2014) High-resolution photoacoustic tomography of resting-state functional connectivity in the mouse brain. Proc Natl Acad Sci U S A 111(1):21\u201326. https:\/\/doi.org\/10.1073\/pnas.1311868111","journal-title":"Proc Natl Acad Sci U S A"},{"issue":"1","key":"48_CR12","doi-asserted-by":"publisher","first-page":"31","DOI":"10.1109\/TBME.2017.2690959","volume":"65","author":"M Mozaffarzadeh","year":"2018","unstructured":"Mozaffarzadeh M, Mahloojifar A, Orooji M, Adabi S, Nasiriavanaki M (2018) Double-stage delay multiply and sum beamforming algorithm: application to linear-array photoacoustic imaging. IEEE Trans Biomed Eng 65(1):31\u201342. https:\/\/doi.org\/10.1109\/TBME.2017.2690959","journal-title":"IEEE Trans Biomed Eng"},{"issue":"1","key":"48_CR13","doi-asserted-by":"publisher","first-page":"51","DOI":"10.1109\/JPROC.2019.2936809","volume":"108","author":"K Gong","year":"2020","unstructured":"Gong K, Berg E, Cherry SR, Qi JY (2020) Machine learning in PET: from photon detection to quantitative image reconstruction. Proc IEEE 108(1):51\u201368. https:\/\/doi.org\/10.1109\/JPROC.2019.2936809","journal-title":"Proc IEEE"},{"issue":"6","key":"48_CR14","doi-asserted-by":"publisher","first-page":"1478","DOI":"10.1109\/TMI.2018.2832613","volume":"37","author":"K Kim","year":"2018","unstructured":"Kim K, Wu DF, Gong K, Dutta J, Kim JH, Son YD et al (2018) Penalized PET reconstruction using deep learning prior and local linear fitting. IEEE Trans Med Imaging 37(6):1478\u20131487. https:\/\/doi.org\/10.1109\/TMI.2018.2832613","journal-title":"IEEE Trans Med Imaging"},{"key":"48_CR15","unstructured":"Wang TH, Lei Y, Fu YB, Curran WJ, Liu T, Yang XF (2020) Machine learning in quantitative PET imaging. arXiv"},{"key":"48_CR16","doi-asserted-by":"publisher","first-page":"96594","DOI":"10.1109\/ACCESS.2019.2929230","volume":"7","author":"F Hashimoto","year":"2019","unstructured":"Hashimoto F, Ohba H, Ote K, Teramoto A, Tsukada H (2019) Dynamic PET image denoising using deep convolutional neural networks without prior training datasets. IEEE Access 7:96594\u201396603. https:\/\/doi.org\/10.1109\/ACCESS.2019.2929230","journal-title":"IEEE Access"},{"key":"48_CR17","doi-asserted-by":"publisher","first-page":"550","DOI":"10.1016\/j.neuroimage.2018.03.045","volume":"174","author":"Y Wang","year":"2018","unstructured":"Wang Y, Yu BT, Wang L, Zu C, Lalush DS, Lin WL et al (2018) 3D conditional generative adversarial networks for high-quality PET image estimation at low dose. NeuroImage 174:550\u2013562. https:\/\/doi.org\/10.1016\/j.neuroimage.2018.03.045","journal-title":"NeuroImage"},{"key":"48_CR18","doi-asserted-by":"publisher","first-page":"406","DOI":"10.1016\/j.neucom.2017.06.048","volume":"267","author":"L Xiang","year":"2017","unstructured":"Xiang L, Qiao Y, Nie D, An L, Lin WL, Wang Q et al (2017) Deep auto-context convolutional neural networks for standard-dose PET image estimation from low-dose PET\/MRI. Neurocomputing 267:406\u2013416. https:\/\/doi.org\/10.1016\/j.neucom.2017.06.048","journal-title":"Neurocomputing"},{"issue":"16","key":"48_CR19","doi-asserted-by":"publisher","first-page":"165019","DOI":"10.1088\/1361-6560\/ab3242","volume":"64","author":"WZ Lu","year":"2019","unstructured":"Lu WZ, Onofrey JA, Lu YH, Shi LY, Ma TY, Liu YQ et al (2019) An investigation of quantitative accuracy for deep learning based denoising in oncological PET. Phys Med Biol 64(16):165019. https:\/\/doi.org\/10.1088\/1361-6560\/ab3242","journal-title":"Phys Med Biol"}],"container-title":["Visual Computing for Industry, Biomedicine, and Art"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s42492-020-00048-8.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s42492-020-00048-8\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s42492-020-00048-8.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,4,29]],"date-time":"2021-04-29T01:07:49Z","timestamp":1619658469000},"score":1,"resource":{"primary":{"URL":"https:\/\/vciba.springeropen.com\/articles\/10.1186\/s42492-020-00048-8"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,4,29]]},"references-count":19,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2020,12]]}},"alternative-id":["48"],"URL":"https:\/\/doi.org\/10.1186\/s42492-020-00048-8","relation":{},"ISSN":["2524-4442"],"issn-type":[{"value":"2524-4442","type":"electronic"}],"subject":[],"published":{"date-parts":[[2020,4,29]]},"assertion":[{"value":"6 January 2020","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"14 April 2020","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"29 April 2020","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"None of the authors have any competing interests in the manuscript.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"10"}}