{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,2,21]],"date-time":"2025-02-21T23:32:51Z","timestamp":1740180771870,"version":"3.37.3"},"reference-count":14,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2020,5,22]],"date-time":"2020-05-22T00:00:00Z","timestamp":1590105600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2020,5,22]],"date-time":"2020-05-22T00:00:00Z","timestamp":1590105600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Vis. Comput. Ind. Biomed. Art"],"published-print":{"date-parts":[[2020,12]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:p>A linear denoising filter is usually of lowpass type, and the main parameter in a lowpass filter is the cutoff frequency. The lowpass filters are normally shift invariant and can be implemented as convolution in the spatial domain or as multiplication in the Fourier domain. This paper presents a linear filter that is not characterized by its cutoff frequency but is characterized by the noise model. An example of such a linear filter is presented for low-dose X-ray computed tomography (CT).<\/jats:p>","DOI":"10.1186\/s42492-020-00051-z","type":"journal-article","created":{"date-parts":[[2020,5,22]],"date-time":"2020-05-22T00:02:38Z","timestamp":1590105758000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Pre-filter that incorporates the noise model"],"prefix":"10.1186","volume":"3","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-0790-6043","authenticated-orcid":false,"given":"Gengsheng L.","family":"Zeng","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2020,5,22]]},"reference":[{"issue":"Bk.4","key":"51_CR1","first-page":"5","volume":"52","author":"S Geman","year":"1987","unstructured":"Geman S, McClure DE (1987) Statistical methods for tomographic image reconstruction. Bull Internat Statist Inst 52(Bk.4):5\u201321","journal-title":"Bull Internat Statist Inst"},{"issue":"1","key":"51_CR2","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1111\/j.2517-6161.1977.tb01600.x","volume":"39","author":"A. P. Dempster","year":"1977","unstructured":"Dempster AP, Laird NM, Rubin DB (1977) Maximum likelihood from incomplete data via the EM algorithm. J Roy Statist Soc Ser B (Methodol) 39(1):1\u201338. https:\/\/doi.org\/https:\/\/doi.org\/10.1111\/j.2517-6161.1977.tb01600.x","journal-title":"Journal of the Royal Statistical Society: Series B (Methodological)"},{"issue":"2","key":"51_CR3","doi-asserted-by":"publisher","first-page":"113","DOI":"10.1109\/TMI.1982.4307558","volume":"1","author":"L. A. Shepp","year":"1982","unstructured":"Shepp LA, Vardi Y (1982) Maximum likelihood reconstruction for emission tomography. IEEE Trans Med Imag 1(2):113\u2013122. https:\/\/doi.org\/https:\/\/doi.org\/10.1109\/TMI.1982.4307558","journal-title":"IEEE Transactions on Medical Imaging"},{"issue":"4","key":"51_CR4","doi-asserted-by":"publisher","first-page":"601","DOI":"10.1109\/42.363108","volume":"13","author":"H.M. Hudson","year":"1994","unstructured":"Hudson HM, Larkin RS (1994) Accelerated image reconstruction using ordered subsets of projection data. IEEE Trans Med Imag 13(4):601\u2013609. https:\/\/doi.org\/https:\/\/doi.org\/10.1109\/42.363108","journal-title":"IEEE Transactions on Medical Imaging"},{"issue":"2","key":"51_CR5","first-page":"302","volume":"8","author":"K Lange","year":"1984","unstructured":"Lange K, Carson R (1984) EM reconstruction algorithms for emission and transmission tomography. J Comput Assist Tomogr 8(2):302\u2013316","journal-title":"J Comput Assist Tomogr"},{"issue":"8","key":"51_CR6","doi-asserted-by":"publisher","first-page":"3721","DOI":"10.1002\/mp.13077","volume":"45","author":"Gengsheng L. Zeng","year":"2018","unstructured":"Zeng GL (2018) Technical note: emission expectation maximization look-alike algorithms for x-ray CT and other applications. Med Phys 45(8):3721\u20133727. https:\/\/doi.org\/https:\/\/doi.org\/10.1002\/mp.13077","journal-title":"Medical Physics"},{"key":"51_CR7","doi-asserted-by":"publisher","unstructured":"Zeng GL, Li Y (2019) Extension of emission expectation maximization lookalike algorithms to Bayesian algorithms. Vis Comput Ind, Biomed, Art 2(1):14. https:\/\/doi.org\/https:\/\/doi.org\/10.1186\/s42492-019-0027-4","DOI":"10.1186\/s42492-019-0027-4"},{"issue":"11","key":"51_CR8","doi-asserted-by":"publisher","first-page":"2139","DOI":"10.1118\/1.598410","volume":"25","author":"Jiang Hsieh","year":"1998","unstructured":"Hsieh J (1998) Adaptive streak artifact reduction in computed tomography resulting from excessive X-ray photon noise. Med Phys 25(11):2139\u20132147. https:\/\/doi.org\/https:\/\/doi.org\/10.1118\/1.598410","journal-title":"Medical Physics"},{"key":"51_CR9","doi-asserted-by":"publisher","unstructured":"Kachelrie\u00df M (2009)Branchless vectorized median filtering. Paper presented at 2009 IEEE nuclear science symposium conference record, IEEE, Orlando, pp 4099\u20134105. https:\/\/doi.org\/https:\/\/doi.org\/10.1109\/NSSMIC.2009.5402362","DOI":"10.1109\/NSSMIC.2009.5402362"},{"issue":"4","key":"51_CR10","doi-asserted-by":"publisher","first-page":"475","DOI":"10.1118\/1.1358303","volume":"28","author":"Marc Kachelrie\u00df","year":"2001","unstructured":"Kachelrie\u00df M, Watzke O, Kalender WA (2001) Generalized multi-dimensional adaptive filtering for conventional and spiral single-slice, multi-slice, and cone-beam CT. Med Phys 28(4):475\u2013490. https:\/\/doi.org\/https:\/\/doi.org\/10.1118\/1.1358303","journal-title":"Medical Physics"},{"issue":"3","key":"51_CR11","doi-asserted-by":"publisher","first-page":"031113","DOI":"10.1118\/1.4790696","volume":"40","author":"Gengsheng L. Zeng","year":"2013","unstructured":"Zeng GL, Zamyatin A (2013) A filtered backprojection algorithm with ray-by-ray noise weighting. Med Phys 40(3):031113. https:\/\/doi.org\/https:\/\/doi.org\/10.1118\/1.4790696","journal-title":"Medical Physics"},{"key":"51_CR12","doi-asserted-by":"publisher","DOI":"10.1515\/9783110500592","volume-title":"Image reconstruction: applications in medical sciences","author":"GL Zeng","year":"2017","unstructured":"Zeng GL (2017) Image reconstruction: applications in medical sciences. Walter de Gruyter GmbH, Berlin\/Boston"},{"issue":"3","key":"51_CR13","doi-asserted-by":"publisher","first-page":"615","DOI":"10.2307\/2372313","volume":"73","author":"L. Landweber","year":"1951","unstructured":"Landweber L (1951) An iteration formula for Fredholm integral equations of the first kind. Am J Math 73(3):615\u2013624. https:\/\/doi.org\/https:\/\/doi.org\/10.2307\/2372313","journal-title":"American Journal of Mathematics"},{"issue":"4","key":"51_CR14","doi-asserted-by":"publisher","first-page":"045004","DOI":"10.1088\/2057-1976\/2\/4\/045004","volume":"2","author":"Gengsheng L Zeng","year":"2016","unstructured":"Zeng GL, Wang WW (2016) Noise weighting with an exponent for transmission CT. Biomed Phys Eng Express 2(4):045004. https:\/\/doi.org\/https:\/\/doi.org\/10.1088\/2057-1976\/2\/4\/045004","journal-title":"Biomedical Physics & Engineering Express"}],"container-title":["Visual Computing for Industry, Biomedicine, and Art"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s42492-020-00051-z.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s42492-020-00051-z\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s42492-020-00051-z.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,5,21]],"date-time":"2021-05-21T23:07:21Z","timestamp":1621638441000},"score":1,"resource":{"primary":{"URL":"https:\/\/vciba.springeropen.com\/articles\/10.1186\/s42492-020-00051-z"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,5,22]]},"references-count":14,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2020,12]]}},"alternative-id":["51"],"URL":"https:\/\/doi.org\/10.1186\/s42492-020-00051-z","relation":{},"ISSN":["2524-4442"],"issn-type":[{"type":"electronic","value":"2524-4442"}],"subject":[],"published":{"date-parts":[[2020,5,22]]},"assertion":[{"value":"27 January 2020","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"30 April 2020","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"22 May 2020","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"None of the authors have any competing interests in the manuscript.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"13"}}