{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,8]],"date-time":"2026-01-08T20:47:34Z","timestamp":1767905254024,"version":"3.49.0"},"reference-count":20,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2021,4,8]],"date-time":"2021-04-08T00:00:00Z","timestamp":1617840000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2021,4,8]],"date-time":"2021-04-08T00:00:00Z","timestamp":1617840000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/501100013093","name":"Science and Technology Planning Project of Shenzhen Municipality","doi-asserted-by":"crossref","award":["JCYJ20200109113808048"],"award-info":[{"award-number":["JCYJ20200109113808048"]}],"id":[{"id":"10.13039\/501100013093","id-type":"DOI","asserted-by":"crossref"}]},{"DOI":"10.13039\/501100003453","name":"Natural Science Foundation of Guangdong Province","doi-asserted-by":"crossref","award":["2020A1515010958"],"award-info":[{"award-number":["2020A1515010958"]}],"id":[{"id":"10.13039\/501100003453","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Vis. Comput. Ind. Biomed. Art"],"published-print":{"date-parts":[[2021,12]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:p>Acoustic\/ultrasonic sensors are devices that can convert mechanical energy into electrical signals. The Fabry\u2013Perot cavity is processed on the end face of the double-clad fiber by a two-photon three-dimensional lithography machine. In this study, the outer diameter of the core cladding was 250\u2009\u03bcm, the diameter of the core was 9\u2009\u03bcm, and the microcavity sensing unit was only 30\u2009\u03bcm. It could measure ultrasonic signals with high precision. The characteristics of the proposed ultrasonic sensor were investigated, and its feasibility was proven through experiments. Its design has a small size and can replace a larger ultrasonic detector device for photoacoustic signal detection. The sensor is applicable to the field of biomedical information technology, including medical diagnosis, photoacoustic endoscopy, and photoacoustic imaging.<\/jats:p>","DOI":"10.1186\/s42492-021-00074-0","type":"journal-article","created":{"date-parts":[[2021,4,8]],"date-time":"2021-04-08T13:03:17Z","timestamp":1617886997000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":6,"title":["Ultrasonic signal detection based on Fabry\u2013Perot cavity sensor"],"prefix":"10.1186","volume":"4","author":[{"given":"Wu","family":"Yang","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-9259-8972","authenticated-orcid":false,"given":"Chonglei","family":"Zhang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jiaqi","family":"Zeng","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Wei","family":"Song","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2021,4,8]]},"reference":[{"issue":"1","key":"74_CR1","first-page":"53","volume":"20","author":"Z Lan","year":"2019","unstructured":"Lan Z, Chi WJ, Fu LY (2019) Analysis on the disease composition of inpatients with digestive system malignant tumor in a hospital from 2013 to 2017. Chin Med Rec 20(1):53\u201356","journal-title":"Chin Med Rec"},{"key":"74_CR2","doi-asserted-by":"publisher","unstructured":"R\u00f6sch T, Lightdale CJ, Botet JF, Boyce GA, Sivak MV Jr, Yasuda K et al (1992) Localization of pancreatic endocrine tumors by endoscopic ultrasonography. N Engl J Med 326(26):1721\u20131726. https:\/\/doi.org\/10.1056\/NEJM199206253262601","DOI":"10.1056\/NEJM199206253262601"},{"issue":"6075","key":"74_CR3","doi-asserted-by":"publisher","first-page":"1458","DOI":"10.1126\/science.1216210","volume":"335","author":"LV Wang","year":"2012","unstructured":"Wang LV, Hu S (2012) Photoacoustic tomography: in vivo imaging from organelles to organs. Science 335(6075):1458\u20131462. https:\/\/doi.org\/10.1126\/science.1216210","journal-title":"Science"},{"key":"74_CR4","doi-asserted-by":"publisher","first-page":"822316","DOI":"10.1117\/12.909163","volume":"8223","author":"JM Yang","year":"2012","unstructured":"Yang JM, Favazza C, Chen RM, Yao JJ, Cai X, Maslov K et al (2012) Toward dual-wavelength functional photoacoustic endoscopy: laser and peripheral optical systems development. Proc SPIE 8223:822316","journal-title":"Proc SPIE"},{"issue":"16","key":"74_CR5","doi-asserted-by":"publisher","first-page":"3617","DOI":"10.3390\/s19163617","volume":"19","author":"J Chan","year":"2019","unstructured":"Chan J, Zheng Z, Bell K, le M, Reza PH, Yeow JTW (2019) Photoacoustic imaging with capacitive micromachined ultrasound transducers: principles and developments. Sensors 19(16):3617. https:\/\/doi.org\/10.3390\/s19163617","journal-title":"Sensors"},{"key":"74_CR6","doi-asserted-by":"publisher","unstructured":"Finlay MC, Mosse CA, Colchester RJ, Noimark S, Zhang EZ, Ourselin S, et al (2017) Through-needle all-optical ultrasound imaging in vivo: a preclinical swine study. Light Sci Appl 6(12):e17103. https:\/\/doi.org\/10.1038\/lsa.2017.103","DOI":"10.1038\/lsa.2017.103"},{"issue":"10","key":"74_CR7","doi-asserted-by":"publisher","first-page":"e201870164","DOI":"10.1002\/jbio.201870164","volume":"11","author":"Y Li","year":"2018","unstructured":"Li Y, Lin RQ, Liu CB, Chen JH, Liu HD, Zheng RQ et al (2018) Inside cover: in vivo photoacoustic\/ultrasonic dual-modality endoscopy with a miniaturized full field-of-view catheter (J. biophotonics 10\/2018). J Biophotonics 11(10):e201870164","journal-title":"J Biophotonics"},{"key":"74_CR8","doi-asserted-by":"publisher","unstructured":"Li CY, Yang JM, Chen RM, Yeh CH, Zhu LR, Maslov K, et al (2014) Urogenital photoacoustic endoscope. Opt Lett 39(6):1473\u20131476. https:\/\/doi.org\/10.1364\/OL.39.001473","DOI":"10.1364\/OL.39.001473"},{"issue":"2","key":"74_CR9","doi-asserted-by":"publisher","first-page":"139","DOI":"10.1016\/j.pmatsci.2010.09.001","volume":"56","author":"QF Zhou","year":"2011","unstructured":"Zhou QF, Lau S, Wu DW, Shung KK (2011) Piezoelectric films for high frequency ultrasonic transducers in biomedical applications. Prog Mater Sci 56(2):139\u2013174. https:\/\/doi.org\/10.1016\/j.pmatsci.2010.09.001","journal-title":"Prog Mater Sci"},{"key":"74_CR10","doi-asserted-by":"publisher","unstructured":"Guggenheim JA, Li J, Allen TJ, Colchester RJ, Noimark S, Ogunlade O, et al (2017) Ultrasensitive Plano-concave optical microresonators for ultrasound sensing. Nature Photon 11(11):714\u2013719. https:\/\/doi.org\/10.1038\/s41566-017-0027-x","DOI":"10.1038\/s41566-017-0027-x"},{"issue":"1","key":"74_CR11","doi-asserted-by":"publisher","first-page":"55","DOI":"10.1080\/10584587.2020.1728715","volume":"208","author":"LL Liu","year":"2020","unstructured":"Liu LL, Ren YQ, Wang M, Zou M (2020) Optical fiber fabry-perot interferometer sensor fabricated by femtosecond laser-induced water breakdown. Integr Ferroelectr 208(1):55\u201359. https:\/\/doi.org\/10.1080\/10584587.2020.1728715","journal-title":"Integr Ferroelectr"},{"key":"74_CR12","doi-asserted-by":"publisher","first-page":"45","DOI":"10.1007\/978-981-13-8595-7_5","volume-title":"Proceedings of 2018 international conference on optoelectronics and measurement. Lecture notes in electrical engineering, vol 567","author":"H Li","year":"2020","unstructured":"Li H, Zhao QC, Ni JS, Ma L, Zhang FX, Wang C (2020) Fabry-perot cavity-based optical fiber pressure sensor. In: Peng Y, Dong X (eds) Proceedings of 2018 international conference on optoelectronics and measurement. Lecture notes in electrical engineering, vol 567. Springer, Singapore, pp 45\u201351. https:\/\/doi.org\/10.1007\/978-981-13-8595-7_5"},{"key":"74_CR13","doi-asserted-by":"publisher","first-page":"801","DOI":"10.1049\/el:19970545","volume":"33","author":"PC Beard","year":"1997","unstructured":"Beard PC, Mills TN (1997) Miniature optical fibre ultrasonic hydrophone using a Fabry-Perot polymer film interferometer. Electronic Lett 33:801\u2013803","journal-title":"Electronic Lett"},{"key":"74_CR14","doi-asserted-by":"publisher","unstructured":"Jathoul AP, Laufer J, Ogunlade O, Treeby B, Cox B, Zhang E et al (2015) Deep in vivo photoacoustic imaging of mammalian tissues using a tyrosinase-based genetic reporter. Nature Photon 9(4):239\u2013246. https:\/\/doi.org\/10.1038\/nphoton.2015.22","DOI":"10.1038\/nphoton.2015.22"},{"key":"74_CR15","volume-title":"High-Q optical micro-cavity resonators as high sensitive bio-chemical and ultrasonic sensors","author":"L Tao","year":"2012","unstructured":"Tao L (2012) High-Q optical micro-cavity resonators as high sensitive bio-chemical and ultrasonic sensors. University of Michigan, Dissertation"},{"issue":"5","key":"74_CR16","doi-asserted-by":"publisher","first-page":"2607","DOI":"10.1364\/BOE.391980","volume":"11","author":"BH Chen","year":"2020","unstructured":"Chen BH, Chen YW, Ma C (2020) Photothermally tunable Fabry-P\u00e9rot fiber interferometer for photoacoustic mesoscopy. Biomed Opt Express 11(5):2607\u20132618. https:\/\/doi.org\/10.1364\/BOE.391980","journal-title":"Biomed Opt Express"},{"key":"74_CR17","volume-title":"The optical modelling and design of Fabry Perot interferometer sensors for ultrasound detection. Dissertation, University College London","author":"HS Varu","year":"2014","unstructured":"Varu HS (2014) The optical modelling and design of Fabry Perot interferometer sensors for ultrasound detection. Dissertation, University College London"},{"issue":"21","key":"74_CR18","doi-asserted-by":"publisher","first-page":"25023","DOI":"10.1364\/OE.25.025023","volume":"25","author":"GY Li","year":"2017","unstructured":"Li GY, Guo ZD, Chen SL (2017) Miniature all-optical probe for large synthetic aperture photoacoustic-ultrasound imaging. Opt Express 25(21):25023\u201325035. https:\/\/doi.org\/10.1364\/OE.25.025023","journal-title":"Opt Express"},{"key":"74_CR19","doi-asserted-by":"crossref","unstructured":"Chen B, Chu F, Liu X, Li Y, Jian R, Jiang H (2013) AlN-based piezoelectric micromachined ultrasonic transducer for photoacoustic imaging. Appl Phys Lett 103(3):031118","DOI":"10.1063\/1.4816085"},{"issue":"4","key":"74_CR20","doi-asserted-by":"publisher","first-page":"561","DOI":"10.1364\/AO.47.000561","volume":"47","author":"E Zhang","year":"2008","unstructured":"Zhang E, Laufer J, Beard P (2008) Backward-mode multiwavelength photoacoustic scanner using a planar Fabry-Perot polymer film ultrasound sensor for high-resolution three-dimensional imaging of biological tissues. Appl Opt 47(4):561\u2013577. https:\/\/doi.org\/10.1364\/AO.47.000561","journal-title":"Appl Opt"}],"updated-by":[{"DOI":"10.1186\/s42492-021-00079-9","type":"correction","label":"Correction","source":"publisher","updated":{"date-parts":[[2021,5,10]],"date-time":"2021-05-10T00:00:00Z","timestamp":1620604800000}}],"container-title":["Visual Computing for Industry, Biomedicine, and Art"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s42492-021-00074-0.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s42492-021-00074-0\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s42492-021-00074-0.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,7,30]],"date-time":"2021-07-30T21:12:52Z","timestamp":1627679572000},"score":1,"resource":{"primary":{"URL":"https:\/\/vciba.springeropen.com\/articles\/10.1186\/s42492-021-00074-0"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,4,8]]},"references-count":20,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2021,12]]}},"alternative-id":["74"],"URL":"https:\/\/doi.org\/10.1186\/s42492-021-00074-0","relation":{"correction":[{"id-type":"doi","id":"10.1186\/s42492-021-00079-9","asserted-by":"object"}]},"ISSN":["2524-4442"],"issn-type":[{"value":"2524-4442","type":"electronic"}],"subject":[],"published":{"date-parts":[[2021,4,8]]},"assertion":[{"value":"16 November 2020","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"15 March 2021","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"8 April 2021","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"10 May 2021","order":4,"name":"change_date","label":"Change Date","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"Correction","order":5,"name":"change_type","label":"Change Type","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"A Correction to this paper has been published:","order":6,"name":"change_details","label":"Change Details","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"https:\/\/doi.org\/10.1186\/s42492-021-00079-9","URL":"https:\/\/doi.org\/10.1186\/s42492-021-00079-9","order":7,"name":"change_details","label":"Change Details","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The authors declare that they have no competing interests.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"8"}}