{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,8]],"date-time":"2026-06-08T14:50:56Z","timestamp":1780930256076,"version":"3.54.1"},"reference-count":74,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2022,10,1]],"date-time":"2022-10-01T00:00:00Z","timestamp":1664582400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2022,10,1]],"date-time":"2022-10-01T00:00:00Z","timestamp":1664582400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"name":"National Key Research and Development Program of China","award":["2017YFA0700401"],"award-info":[{"award-number":["2017YFA0700401"]}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Vis. Comput. Ind. Biomed. Art"],"abstract":"<jats:title>Abstract<\/jats:title><jats:p>Magnetic particle imaging (MPI) is an emerging molecular imaging technique with high sensitivity and temporal-spatial resolution. Image reconstruction is an important research topic in MPI, which converts an induced voltage signal into the image of superparamagnetic iron oxide particles concentration distribution. MPI reconstruction primarily involves system matrix- and x-space-based methods. In this review, we provide a detailed overview of the research status and future research trends of these two methods. In addition, we review the application of deep learning methods in MPI reconstruction and the current open sources of MPI. Finally, research opinions on MPI reconstruction are presented. We hope this review promotes the use of MPI in clinical applications.<\/jats:p>","DOI":"10.1186\/s42492-022-00120-5","type":"journal-article","created":{"date-parts":[[2022,10,1]],"date-time":"2022-10-01T02:03:08Z","timestamp":1664589788000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":61,"title":["Recent developments of the reconstruction in magnetic particle imaging"],"prefix":"10.1186","volume":"5","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-4325-345X","authenticated-orcid":false,"given":"Lin","family":"Yin","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Wei","family":"Li","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yang","family":"Du","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kun","family":"Wang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Zhenyu","family":"Liu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hui","family":"Hui","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jie","family":"Tian","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2022,10,1]]},"reference":[{"issue":"7046","key":"120_CR1","doi-asserted-by":"publisher","first-page":"1214","DOI":"10.1038\/nature03808","volume":"435","author":"B Gleich","year":"2005","unstructured":"Gleich B, Weizenecker J (2005) Tomographic imaging using the nonlinear response of magnetic particles. Nature 435(7046):1214-1217. https:\/\/doi.org\/10.1038\/nature03808","journal-title":"Nature"},{"issue":"5","key":"120_CR2","doi-asserted-by":"publisher","first-page":"L1","DOI":"10.1088\/0031-9155\/54\/5\/L01","volume":"54","author":"J Weizenecker","year":"2009","unstructured":"Weizenecker J, Gleich B, Rahmer J, Dahnke H, Borgert J (2009) Three-dimensional real-time in vivo magnetic particle imaging. Phys Med Biol 54(5):L1-L10. https:\/\/doi.org\/10.1088\/0031-9155\/54\/5\/L01","journal-title":"Phys Med Biol"},{"issue":"4","key":"120_CR3","doi-asserted-by":"publisher","first-page":"1056","DOI":"10.1109\/tmi.2015.2507187","volume":"35","author":"K Gr\u00e4fe","year":"2016","unstructured":"Gr\u00e4fe K, von Gladiss A, Bringout G, Ahlborg M, Buzug TM (2016) 2D images recorded with a single-sided magnetic particle imaging scanner. IEEE Trans Med Imaging 35(4):1056-1065. https:\/\/doi.org\/10.1109\/tmi.2015.2507187","journal-title":"IEEE Trans Med Imaging"},{"key":"120_CR4","doi-asserted-by":"publisher","first-page":"293","DOI":"10.1016\/j.addr.2018.12.007","volume":"138","author":"JWM Bulte","year":"2019","unstructured":"Bulte JWM (2019) Superparamagnetic iron oxides as MPI tracers: a primer and review of early applications. Adv Drug Deliv Rev 138:293-301. https:\/\/doi.org\/10.1016\/j.addr.2018.12.007","journal-title":"Adv Drug Deliv Rev"},{"key":"120_CR5","doi-asserted-by":"publisher","DOI":"10.1016\/j.measurement.2019.107281","volume":"152","author":"M Meribout","year":"2020","unstructured":"Meribout M, Kalra M (2020) A portable system for two dimensional magnetic particle imaging. Measurement 152:107281. https:\/\/doi.org\/10.1016\/j.measurement.2019.107281","journal-title":"Measurement"},{"issue":"2 Suppl 1","key":"120_CR6","doi-asserted-by":"publisher","first-page":"2009067","DOI":"10.18416\/IJMPI.2020.2009067","volume":"6","author":"TA Le","year":"2020","unstructured":"Le TA, Bui MP, Yoon J (2020) Design of a rabbit scale 3D magnetic particle imaging system with amplitude modulation. Int J Mag Part Imaging 6(2 Suppl 1):2009067. https:\/\/doi.org\/10.18416\/IJMPI.2020.2009067","journal-title":"Int J Mag Part Imaging"},{"issue":"1","key":"120_CR7","doi-asserted-by":"publisher","first-page":"4","DOI":"10.1186\/1471-2342-9-4","volume":"9","author":"J Rahmer","year":"2009","unstructured":"Rahmer J, Weizenecker J, Gleich B, Borgert J (2009) Signal encoding in magnetic particle imaging: properties of the system function. BMC Med Imaging 9(1):4. https:\/\/doi.org\/10.1186\/1471-2342-9-4","journal-title":"BMC Med Imaging"},{"issue":"6","key":"120_CR8","doi-asserted-by":"publisher","first-page":"583","DOI":"10.1515\/bmt-2012-0063","volume":"58","author":"M Gr\u00fcttner","year":"2013","unstructured":"Gr\u00fcttner M, Knopp T, Franke J, Heidenreich M, Rahmer J, Halkola A et al (2013) On the formulation of the image reconstruction problem in magnetic particle imaging. Biomed Tech 58(6):583-591. https:\/\/doi.org\/10.1515\/bmt-2012-0063","journal-title":"Biomed Tech"},{"issue":"274","key":"120_CR9","doi-asserted-by":"publisher","first-page":"274ra17","DOI":"10.1126\/scitranslmed.aaa1009","volume":"7","author":"S Venneti","year":"2015","unstructured":"Venneti S, Dunphy MP, Zhang HW, Pitter KL, Zanzonico P, Campos C et al (2015) Glutamine-based PET imaging facilitates enhanced metabolic evaluation of gliomas in vivo. Sci Transl Med 7(274):274ra17. https:\/\/doi.org\/10.1126\/scitranslmed.aaa1009","journal-title":"Sci Transl Med"},{"issue":"7","key":"120_CR10","doi-asserted-by":"publisher","first-page":"2023","DOI":"10.1109\/TBME.2019.2953732","volume":"67","author":"L Yin","year":"2020","unstructured":"Yin L, Wang K, Tong T, An Y, Meng H, Yang X et al (2020) Improved block sparse Bayesian learning method using K-nearest neighbor strategy for accurate tumor morphology reconstruction in bioluminescence tomography. IEEE Trans Biomed Eng 67(7):2023-2032. https:\/\/doi.org\/10.1109\/TBME.2019.2953732","journal-title":"IEEE Trans Biomed Eng"},{"issue":"4","key":"120_CR11","doi-asserted-by":"publisher","first-page":"333","DOI":"10.3322\/caac.21713","volume":"72","author":"SP Rowe","year":"2022","unstructured":"Rowe SP, Pomper MG (2022) Molecular imaging in oncology: current impact and future directions. CA: Cancer J Clin 72(4):333-352. https:\/\/doi.org\/10.3322\/caac.21713","journal-title":"CA: Cancer J Clin"},{"issue":"2","key":"120_CR12","doi-asserted-by":"publisher","first-page":"206","DOI":"10.3174\/ajnr.A5896","volume":"40","author":"LC Wu","year":"2019","unstructured":"Wu LC, Zhang Y, Steinberg G, Qu H, Huang S, Cheng M et al (2019) A review of magnetic particle imaging and perspectives on neuroimaging. AJNR Am J Neuroradiol 40(2):206-212. https:\/\/doi.org\/10.3174\/ajnr.A5896","journal-title":"AJNR Am J Neuroradiol"},{"issue":"4","key":"120_CR13","doi-asserted-by":"publisher","first-page":"3699","DOI":"10.1021\/acsnano.8b00893","volume":"12","author":"ZW Tay","year":"2018","unstructured":"Tay ZW, Chandrasekharan P, Chiu-Lam A, Hensley DW, Dhavalikar R, Zhou XY et al (2018) Magnetic particle imaging-guided heating in vivo using gradient fields for arbitrary localization of magnetic hyperthermia therapy. ACS Nano 12(4):3699-3713. https:\/\/doi.org\/10.1021\/acsnano.8b00893","journal-title":"ACS Nano"},{"issue":"12","key":"120_CR14","doi-asserted-by":"publisher","first-page":"12067","DOI":"10.1021\/acsnano.7b04844","volume":"11","author":"EY Yu","year":"2017","unstructured":"Yu EY, Chandrasekharan P, Berzon R, Tay ZW, Zhou XY, Khandhar AP et al (2017) Magnetic particle imaging for highly sensitive, quantitative, and safe in vivo gut bleed detection in a murine model. ACS Nano 11(12):12067-12076. https:\/\/doi.org\/10.1021\/acsnano.7b04844","journal-title":"ACS Nano"},{"issue":"1","key":"120_CR15","doi-asserted-by":"publisher","first-page":"182","DOI":"10.1021\/acs.nanolett.7b03829","volume":"18","author":"GS Song","year":"2018","unstructured":"Song GS, Chen M, Zhang YR, Cui LY, Qu HB, Zheng XC et al (2018) Janus iron oxides @ semiconducting polymer nanoparticle tracer for cell tracking by magnetic particle imaging. Nano Lett 18(1):182-189. https:\/\/doi.org\/10.1021\/acs.nanolett.7b03829","journal-title":"Nano Lett"},{"issue":"7","key":"120_CR16","doi-asserted-by":"publisher","first-page":"7750","DOI":"10.1021\/acsnano.9b01436","volume":"13","author":"GS Song","year":"2019","unstructured":"Song GS, Zheng XC, Wang YJ, Xia X, Chu S, Rao JH (2019) A magneto-optical nanoplatform for multimodality imaging of tumors in mice. ACS Nano 13(7):7750-7758. https:\/\/doi.org\/10.1021\/acsnano.9b01436","journal-title":"ACS Nano"},{"issue":"40","key":"120_CR17","doi-asserted-by":"publisher","first-page":"16890","DOI":"10.1039\/c5nr02831k","volume":"7","author":"A Tomitaka","year":"2015","unstructured":"Tomitaka A, Arami H, Gandhi S, Krishnan KM (2015) Lactoferrin conjugated iron oxide nanoparticles for targeting brain glioma cells in magnetic particle imaging. Nanoscale 7(40):16890-16898. https:\/\/doi.org\/10.1039\/c5nr02831k","journal-title":"Nanoscale"},{"issue":"12","key":"120_CR18","doi-asserted-by":"publisher","first-page":"6016","DOI":"10.1039\/d0nr07983a","volume":"13","author":"KM Parkins","year":"2021","unstructured":"Parkins KM, Melo KP, Chen YX, Ronald JA, Foster PJ (2021) Visualizing tumour self-homing with magnetic particle imaging. Nanoscale 13(12):6016-6023. https:\/\/doi.org\/10.1039\/d0nr07983a","journal-title":"Nanoscale"},{"issue":"9","key":"120_CR19","doi-asserted-by":"publisher","first-page":"3501","DOI":"10.1088\/1361-6560\/aa52ad","volume":"62","author":"R Orendorff","year":"2017","unstructured":"Orendorff R, Peck AJ, Zheng B, Shirazi SN, Ferguson RM, Khandhar AP et al (2017) First in vivo traumatic brain injury imaging via magnetic particle imaging. Phys Med Biol 62(9):3501. https:\/\/doi.org\/10.1088\/1361-6560\/aa52ad","journal-title":"Phys Med Biol"},{"issue":"10","key":"120_CR20","doi-asserted-by":"publisher","first-page":"13913","DOI":"10.1021\/acsnano.0c06326","volume":"14","author":"P Szwargulski","year":"2020","unstructured":"Szwargulski P, Wilmes M, Javidi E, Thieben F, Graeser M, Koch M et al (2020) Monitoring intracranial cerebral hemorrhage using multicontrast real-time magnetic particle imaging. ACS Nano 14(10):13913-13923. https:\/\/doi.org\/10.1021\/acsnano.0c06326","journal-title":"ACS Nano"},{"issue":"6","key":"120_CR21","doi-asserted-by":"publisher","first-page":"6040","DOI":"10.1126\/sciadv.aax6040","volume":"6","author":"HJ You","year":"2020","unstructured":"You HJ, Shang WT, Min XD, Weinreb J, Li QB, Leapman M et al (2020) Sight and switch off: nerve density visualization for interventions targeting nerves in prostate cancer. Sci Adv 6(6):6040","journal-title":"Sci Adv"},{"issue":"6","key":"120_CR22","doi-asserted-by":"publisher","first-page":"N81","DOI":"10.1088\/0031-9155\/53\/6\/N01","volume":"53","author":"B Gleich","year":"2008","unstructured":"Gleich B, Weizenecker J, Borgert J (2008) Experimental results on fast 2D-encoded magnetic particle imaging. Phys Med Biol 53(6):N81-N84. https:\/\/doi.org\/10.1088\/0031-9155\/53\/6\/N01","journal-title":"Phys Med Biol"},{"issue":"10","key":"120_CR23","doi-asserted-by":"publisher","DOI":"10.1088\/0022-3727\/41\/10\/105009","volume":"41","author":"J Weizenecker","year":"2008","unstructured":"Weizenecker J, Gleich B, Borgert J (2008) Magnetic particle imaging using a field free line. J Phys D: Appl Phys 41(10):105009. https:\/\/doi.org\/10.1088\/0022-3727\/41\/10\/105009","journal-title":"J Phys D: Appl Phys"},{"issue":"4","key":"120_CR24","doi-asserted-by":"publisher","first-page":"1592","DOI":"10.1002\/mp.13411","volume":"46","author":"CB Top","year":"2019","unstructured":"Top CB, G\u00fcng\u00f6r A, Ilbey S, G\u00fcven HE (2019) Trajectory analysis for field free line magnetic particle imaging. Med Phys 46(4):1592-1607. https:\/\/doi.org\/10.1002\/mp.13411","journal-title":"Med Phys"},{"issue":"7","key":"120_CR25","doi-asserted-by":"publisher","first-page":"3538","DOI":"10.1118\/1.3447726","volume":"37","author":"T Knopp","year":"2010","unstructured":"Knopp T, Erbe M, Biederer S, Sattel TF, Buzug TM (2010) Efficient generation of a magnetic field-free line. Med Phys 37(7):3538-3540. https:\/\/doi.org\/10.1118\/1.3447726","journal-title":"Med Phys"},{"issue":"2","key":"120_CR26","doi-asserted-by":"publisher","first-page":"644","DOI":"10.1109\/TMI.2014.2364891","volume":"34","author":"K Bente","year":"2014","unstructured":"Bente K, Weber M, Graeser M, Sattel TF, Erbe M, Buzug TM (2014) Electronic field free line rotation and relaxation deconvolution in magnetic particle imaging. IEEE Trans Med Imaging 34(2):644-651. https:\/\/doi.org\/10.1109\/TMI.2014.2364891","journal-title":"IEEE Trans Med Imaging"},{"issue":"2","key":"120_CR27","doi-asserted-by":"publisher","DOI":"10.1088\/0022-3727\/42\/2\/022001","volume":"42","author":"TF Sattel","year":"2009","unstructured":"Sattel TF, Knopp T, Biederer S, Gleich B, Weizenecker J, Borgert J et al (2009) Single-sided device for magnetic particle imaging. J Phys D: Appl Phys 42(2):022001. https:\/\/doi.org\/10.1088\/0022-3727\/42\/2\/022001","journal-title":"J Phys D: Appl Phys"},{"issue":"2","key":"120_CR28","doi-asserted-by":"publisher","first-page":"6501603","DOI":"10.1109\/TMAG.2014.2322897","volume":"51","author":"P Vogel","year":"2015","unstructured":"Vogel P, R\u00fcckert MA, Klauer P, Kullmann WH, Jakob PM, Behr VC (2015) Superspeed traveling wave magnetic particle imaging. IEEE Trans Magn 51(2):6501603. https:\/\/doi.org\/10.1109\/TMAG.2014.2322897","journal-title":"IEEE Trans Magn"},{"issue":"9","key":"120_CR29","doi-asserted-by":"publisher","first-page":"1993","DOI":"10.1109\/TMI.2016.2542041","volume":"35","author":"J Franke","year":"2016","unstructured":"Franke J, Heinen U, Lehr H, Weber A, Jaspard F, Ruhm W et al (2016) System characterization of a highly integrated preclinical hybrid mpi-mri scanner. IEEE Trans Med Imaging 35(9):1993-2004. https:\/\/doi.org\/10.1109\/TMI.2016.2542041","journal-title":"IEEE Trans Med Imaging"},{"issue":"1","key":"120_CR30","doi-asserted-by":"publisher","first-page":"1936","DOI":"10.1038\/s41467-019-09704-x","volume":"10","author":"M Gr\u00e4ser","year":"2019","unstructured":"Gr\u00e4ser M, Thieben F, Szwargulski P, Werner F, Gdaniec N, Boberg M et al (2019) Human-sized magnetic particle imaging for brain applications. Nat Commun 10(1):1936. https:\/\/doi.org\/10.1038\/s41467-019-09704-x","journal-title":"Nat Commun"},{"issue":"12","key":"120_CR31","doi-asserted-by":"publisher","first-page":"4164","DOI":"10.1109\/TMI.2020.3014197","volume":"39","author":"CB Top","year":"2020","unstructured":"Top CB, G\u00fcng\u00f6r A (2020) Tomographic field free line magnetic particle imaging with an open-sided scanner configuration. IEEE Trans Med Imaging 39(12):4164-4173. https:\/\/doi.org\/10.1109\/TMI.2020.3014197","journal-title":"IEEE Trans Med Imaging"},{"issue":"1","key":"120_CR32","doi-asserted-by":"publisher","first-page":"13456","DOI":"10.1038\/s41598-021-92644-8","volume":"11","author":"EE Mason","year":"2021","unstructured":"Mason EE, Mattingly E, Herb K, \u015aliwiak M, Franconi S, Cooley CZ et al (2021) Concept for using magnetic particle imaging for intraoperative margin analysis in breast-conserving surgery. Sci Rep 11(1):13456. https:\/\/doi.org\/10.1038\/s41598-021-92644-8","journal-title":"Sci Rep"},{"issue":"1","key":"120_CR33","doi-asserted-by":"publisher","first-page":"1703022","DOI":"10.18416\/ijmpi.2017.1703022","volume":"3","author":"S Ilbey","year":"2017","unstructured":"Ilbey S, Top CB, G\u00fcng\u00f6r A, \u00c7ukur T, Saritas EU, G\u00fcven HE (2017) Comparison of system-matrix-based and projection-based reconstructions for field free line magnetic particle imaging. Int J Mag Part Imag 3(1):1703022. https:\/\/doi.org\/10.18416\/ijmpi.2017.1703022","journal-title":"Int J Mag Part Imag"},{"issue":"11","key":"120_CR34","doi-asserted-by":"publisher","first-page":"2476","DOI":"10.1109\/TMI.2016.2580458","volume":"35","author":"C Kaethner","year":"2016","unstructured":"Kaethner C, Erb W, Ahlborg M, Szwargulski P, Knopp T, Buzug TM (2016) Non-equispaced system matrix acquisition for magnetic particle imaging based on lissajous node points. IEEE Trans Med Imaging 35(11):2476-2485. https:\/\/doi.org\/10.1109\/TMI.2016.2580458","journal-title":"IEEE Trans Med Imaging"},{"issue":"1","key":"120_CR35","doi-asserted-by":"publisher","first-page":"3097","DOI":"10.2147\/IJN.S70488","volume":"10","author":"N Panagiotopoulos","year":"2015","unstructured":"Panagiotopoulos N, Duschka RL, Ahlborg M, Bringout G, Debbeler C, Graeser M et al (2015) Magnetic particle imaging: current developments and future directions. Int J Nanomed 10(1):3097-3114. https:\/\/doi.org\/10.2147\/IJN.S70488","journal-title":"Int J Nanomed"},{"issue":"6","key":"120_CR36","doi-asserted-by":"publisher","first-page":"1289","DOI":"10.1109\/TMI.2012.2188639","volume":"31","author":"J Rahmer","year":"2012","unstructured":"Rahmer J, Weizenecker J, Gleich B, Borgert J (2012) Analysis of a 3-D system function measured for magnetic particle imaging. IEEE Trans Med Imaging 31(6):1289-1299. https:\/\/doi.org\/10.1109\/TMI.2012.2188639","journal-title":"IEEE Trans Med Imaging"},{"issue":"8","key":"120_CR37","doi-asserted-by":"publisher","first-page":"1473","DOI":"10.1109\/TMI.2013.2258029","volume":"32","author":"T Knopp","year":"2013","unstructured":"Knopp T, Weber A (2013) Sparse reconstruction of the magnetic particle imaging system matrix. IEEE Trans Med Imaging 32(8):1473-1480. https:\/\/doi.org\/10.1109\/TMI.2013.2258029","journal-title":"IEEE Trans Med Imaging"},{"issue":"1","key":"120_CR38","doi-asserted-by":"publisher","first-page":"12","DOI":"10.1109\/TMI.2009.2021612","volume":"29","author":"T Knopp","year":"2010","unstructured":"Knopp T, Sattel TF, Biederer S, Rahmer J, Weizenecker J, Gleich B et al (2010) Model-based reconstruction for magnetic particle imaging. IEEE Trans Medical Imaging 29(1):12-18. https:\/\/doi.org\/10.1109\/TMI.2009.2021612","journal-title":"IEEE Trans Medical Imaging"},{"issue":"11","key":"120_CR39","doi-asserted-by":"publisher","first-page":"1851","DOI":"10.1109\/TMI.2010.2052284","volume":"29","author":"PW Goodwill","year":"2010","unstructured":"Goodwill PW, Conolly SM (2010) The X-space formulation of the magnetic particle imaging process: 1-D signal, resolution, bandwidth, SNR, SAR, and magnetostimulation. IEEE Trans Med Imaging 29(11):1851-1859. https:\/\/doi.org\/10.1109\/TMI.2010.2052284","journal-title":"IEEE Trans Med Imaging"},{"issue":"28","key":"120_CR40","doi-asserted-by":"publisher","first-page":"3870","DOI":"10.1002\/adma.201200221","volume":"24","author":"PW Goodwill","year":"2012","unstructured":"Goodwill PW, Saritas EU, Croft LR, Kim TN, Krishnan KM, Schaffer DV et al (2012) X-space MPI: magnetic nanoparticles for safe medical imaging. Adv Mat 24(28):3870-3877. https:\/\/doi.org\/10.1002\/adma.201200221","journal-title":"Adv Mat"},{"issue":"16","key":"120_CR41","doi-asserted-by":"publisher","DOI":"10.1088\/1361-6560\/ab3525","volume":"64","author":"AA Ozaslan","year":"2019","unstructured":"Ozaslan AA, Alacaoglu A, Demirel OB, \u00c7ukur T, Saritas EU (2019) Fully automated gridding reconstruction for non-cartesian x-space magnetic particle imaging. Phys Med Biol 64(16):165018. https:\/\/doi.org\/10.1088\/1361-6560\/ab3525","journal-title":"Phys Med Biol"},{"issue":"11","key":"120_CR42","doi-asserted-by":"publisher","first-page":"3441","DOI":"10.1109\/TMI.2020.2995410","volume":"39","author":"S Kurt","year":"2020","unstructured":"Kurt S, Muslu Y, Saritas EU (2020) Partial FOV center imaging (PCI): a robust X-space image reconstruction for magnetic particle imaging. IEEE Trans Med Imaging 39(11):3441-3450. https:\/\/doi.org\/10.1109\/TMI.2020.2995410","journal-title":"IEEE Trans Med Imaging"},{"issue":"4","key":"120_CR43","doi-asserted-by":"publisher","first-page":"932","DOI":"10.1109\/TMI.2018.2875829","volume":"38","author":"P Szwargulski","year":"2019","unstructured":"Szwargulski P, M\u00f6ddel M, Gdaniec N, Knopp T (2019) Efficient joint image reconstruction of multi-patch data reusing a single system matrix in magnetic particle imaging. IEEE Trans Med Imaging 38(4):932-944. https:\/\/doi.org\/10.1109\/TMI.2018.2875829","journal-title":"IEEE Trans Med Imaging"},{"key":"120_CR44","doi-asserted-by":"publisher","first-page":"1389","DOI":"10.1109\/TCI.2020.3024078","volume":"6","author":"M Grosser","year":"2020","unstructured":"Grosser M, M\u00f6ddel M, Knopp T (2020) Using low-rank tensors for the recovery of MPI system matrices. IEEE Trans Comput Imaging 6:1389-1402. https:\/\/doi.org\/10.1109\/TCI.2020.3024078","journal-title":"IEEE Trans Comput Imaging"},{"key":"120_CR45","doi-asserted-by":"publisher","DOI":"10.1155\/2015\/460496","volume":"2015","author":"A Weber","year":"2015","unstructured":"Weber A, Knopp T (2015) Reconstruction of the magnetic particle imaging system matrix using symmetries and compressed sensing. Adv Math Phys 2015:460496. https:\/\/doi.org\/10.1155\/2015\/460496","journal-title":"Adv Math Phys"},{"issue":"9","key":"120_CR46","doi-asserted-by":"publisher","first-page":"2070","DOI":"10.1109\/TMI.2019.2896289","volume":"38","author":"S Ilbey","year":"2019","unstructured":"Ilbey S, Top CB, G\u00fcng\u00f6r A, \u00c7ukur T, Saritas EU, G\u00fcven HE (2019) Fast system calibration with coded calibration scenes for magnetic particle imaging. IEEE Trans Med Imaging 38(9):2070-2080. https:\/\/doi.org\/10.1109\/TMI.2019.2896289","journal-title":"IEEE Trans Med Imaging"},{"issue":"2","key":"120_CR47","doi-asserted-by":"publisher","first-page":"485","DOI":"10.1118\/1.3271258","volume":"37","author":"T Knopp","year":"2010","unstructured":"Knopp T, Biederer S, Sattel TF, Rahmer J, Weizenecker J, Gleich B et al (2010) 2D model-based reconstruction for magnetic particle imaging. Med Phys 37(2):485-491. https:\/\/doi.org\/10.1118\/1.3271258","journal-title":"Med Phys"},{"issue":"5","key":"120_CR48","doi-asserted-by":"publisher","first-page":"276","DOI":"10.11239\/jsmbe.53.276","volume":"53","author":"T Takagi","year":"2016","unstructured":"Takagi T, Tsuchiya H, Hatsuda T, Ishihara Y (2016) Image reconstruction method using orthonormal basis by singular value decomposition for magnetic particle imaging. Trans Japanese Soc Med Biol Eng 53(5):276-282. https:\/\/doi.org\/10.11239\/jsmbe.53.276","journal-title":"Trans Japanese Soc Med Biol Eng"},{"issue":"12","key":"120_CR49","doi-asserted-by":"publisher","DOI":"10.1088\/1361-6560\/ab1a4f","volume":"64","author":"T Kluth","year":"2019","unstructured":"Kluth T, Jin BT (2019) Enhanced reconstruction in magnetic particle imaging by whitening and randomized SVD approximation. Phys Med Biol 64(12):125026. https:\/\/doi.org\/10.1088\/1361-6560\/ab1a4f","journal-title":"Phys Med Biol"},{"issue":"6","key":"120_CR50","doi-asserted-by":"publisher","first-page":"1577","DOI":"10.1088\/0031-9155\/55\/6\/003","volume":"55","author":"T Knopp","year":"2010","unstructured":"Knopp T, Rahmer J, Sattel TF, Biederer S, Weizenecker J, Gleich B et al (2010) Weighted iterative reconstruction for magnetic particle imaging. Phys Med Biol 55(6):1577-1589. https:\/\/doi.org\/10.1088\/0031-9155\/55\/6\/003","journal-title":"Phys Med Biol"},{"issue":"11","key":"120_CR51","doi-asserted-by":"publisher","first-page":"N257","DOI":"10.1088\/0031-9155\/61\/11\/N257","volume":"61","author":"T Knopp","year":"2016","unstructured":"Knopp T, Hofmann M (2016) Online reconstruction of 3D magnetic particle imaging data. Phys Med Biol 61(11):N257-N267. https:\/\/doi.org\/10.1088\/0031-9155\/61\/11\/N257","journal-title":"Phys Med Biol"},{"issue":"12","key":"120_CR52","doi-asserted-by":"publisher","first-page":"e801","DOI":"10.1002\/mp.13543","volume":"46","author":"SS Hsieh","year":"2019","unstructured":"Hsieh SS, Hoffman JM, Noo F (2019) Accelerating iterative coordinate descent using a stored system matrix. Med Phys 46(12):e801-e809. https:\/\/doi.org\/10.1002\/mp.13543","journal-title":"Med Phys"},{"issue":"5","key":"120_CR53","doi-asserted-by":"publisher","first-page":"773","DOI":"10.3390\/diagnostics11050773","volume":"11","author":"XJ Chen","year":"2021","unstructured":"Chen XJ, Jiang ZQ, Han X, Wang XL, Tang XY (2021) The reconstruction of magnetic particle imaging: current approaches based on the system matrix. Diagnostics 11(5):773. https:\/\/doi.org\/10.3390\/diagnostics11050773","journal-title":"Diagnostics"},{"issue":"4","key":"120_CR54","doi-asserted-by":"publisher","first-page":"671","DOI":"10.1109\/TCI.2017.2706058","volume":"3","author":"L Schmiester","year":"2017","unstructured":"Schmiester L, M\u00f6ddel M, Erb W, Knopp T (2017) Direct image reconstruction of lissajous-type magnetic particle imaging data using chebyshev-based matrix compression. IEEE Trans Comput Imaging 3(4):671-681. https:\/\/doi.org\/10.1109\/TCI.2017.2706058","journal-title":"IEEE Trans Comput Imaging"},{"issue":"1","key":"120_CR55","doi-asserted-by":"publisher","first-page":"74","DOI":"10.1109\/TMI.2016.2593954","volume":"36","author":"M Storath","year":"2017","unstructured":"Storath M, Brandt C, Hofmann M, Knopp T, Salamon J, Weber A et al (2017) Edge preserving and noise reducing reconstruction for magnetic particle imaging. IEEE Trans Med Imaging 36(1):74-85. https:\/\/doi.org\/10.1109\/TMI.2016.2593954","journal-title":"IEEE Trans Med Imaging"},{"issue":"9","key":"120_CR56","doi-asserted-by":"publisher","first-page":"1581","DOI":"10.1109\/TMI.2011.2125982","volume":"30","author":"PW Goodwill","year":"2011","unstructured":"Goodwill PW, Conolly SM (2011) Multidimensional X-space magnetic particle imaging. IEEE Trans Med Imaging 30(9):1581-1590. https:\/\/doi.org\/10.1109\/TMI.2011.2125982","journal-title":"IEEE Trans Med Imaging"},{"issue":"5","key":"120_CR57","doi-asserted-by":"publisher","first-page":"1076","DOI":"10.1109\/TMI.2012.2185247","volume":"31","author":"PW Goodwill","year":"2012","unstructured":"Goodwill PW, Konkle JJ, Zheng B, Saritas EU, Conolly SM (2012) Projection X-space magnetic particle imaging. IEEE Trans Med Imaging 31(5):1076-1085. https:\/\/doi.org\/10.1109\/TMI.2012.2185247","journal-title":"IEEE Trans Med Imaging"},{"issue":"3","key":"120_CR58","doi-asserted-by":"publisher","first-page":"1619","DOI":"10.1118\/1.3554646","volume":"38","author":"RM Ferguson","year":"2011","unstructured":"Ferguson RM, Minard KR, Khandhar AP, Krishnan KM (2011) Optimizing magnetite nanoparticles for mass sensitivity in magnetic particle imaging. Med Phys 38(3):1619-1626. https:\/\/doi.org\/10.1118\/1.3554646","journal-title":"Med Phys"},{"issue":"10","key":"120_CR59","doi-asserted-by":"publisher","first-page":"1548","DOI":"10.1016\/j.jmmm.2009.02.083","volume":"321","author":"RM Ferguson","year":"2009","unstructured":"Ferguson RM, Minard KR, Krishnan KM (2009) Optimization of nanoparticle core size for magnetic particle imaging. J Magn Magn Mater 321(10):1548-1551. https:\/\/doi.org\/10.1016\/j.jmmm.2009.02.083","journal-title":"J Magn Magn Mater"},{"issue":"12","key":"120_CR60","doi-asserted-by":"publisher","first-page":"2335","DOI":"10.1109\/TMI.2012.2217979","volume":"31","author":"LR Croft","year":"2012","unstructured":"Croft LR, Goodwill PW, Conolly SM (2012) Relaxation in X-space magnetic particle imaging. IEEE Trans Med Imaging 31(12):2335-2342. https:\/\/doi.org\/10.1109\/TMI.2012.2217979","journal-title":"IEEE Trans. Med Imaging"},{"issue":"23","key":"120_CR61","doi-asserted-by":"publisher","first-page":"1904131","DOI":"10.1002\/adma.201904131","volume":"33","author":"C Shasha","year":"2021","unstructured":"Shasha C, Krishnan KM (2021) Nonequilibrium dynamics of magnetic nanoparticles with applications in biomedicine. Adv Mater 33(23):1904131. https:\/\/doi.org\/10.1002\/adma.201904131","journal-title":"Adv Mater"},{"key":"120_CR62","doi-asserted-by":"publisher","first-page":"133","DOI":"10.1016\/j.jmmm.2016.10.096","volume":"427","author":"N L\u00f6wa","year":"2017","unstructured":"L\u00f6wa N, Seidel M, Radon P, Wiekhorst F (2017) Magnetic nanoparticles in different biological environments analyzed by magnetic particle spectroscopy. J Magn Magn Mater 427:133-138. https:\/\/doi.org\/10.1016\/j.jmmm.2016.10.096","journal-title":"J Magn Magn Mater"},{"issue":"8","key":"120_CR63","doi-asserted-by":"publisher","DOI":"10.1088\/1361-6420\/aac535","volume":"34","author":"T Kluth","year":"2018","unstructured":"Kluth T (2018) Mathematical models for magnetic particle imaging. Inverse Probl 34(8):083001. https:\/\/doi.org\/10.1088\/1361-6420\/aac535","journal-title":"Inverse Probl"},{"key":"120_CR64","doi-asserted-by":"publisher","first-page":"168508","DOI":"10.1016\/j.jmmm.2021.168508","volume":"541","author":"H Albers","year":"2022","unstructured":"Albers H, Kluth T, Knopp T (2022) Simulating magnetization dynamics of large ensembles of single domain nanoparticles: numerical study of brown\/n\u00e9el dynamics and parameter identification problems in magnetic particle imaging. J Magn Magn Mater 541:168508. https:\/\/doi.org\/10.1016\/j.jmmm.2021.168508","journal-title":"J Magn Magn Mater"},{"issue":"1","key":"120_CR65","doi-asserted-by":"publisher","first-page":"012301","DOI":"10.1118\/1.4837216","volume":"41","author":"RJ Deissler","year":"2014","unstructured":"Deissler RJ, Wu Y, Martens MA (2014) Dependence of Brownian and N\u00e9el relaxation times on magnetic field strength. Med Phys 41(1):012301. https:\/\/doi.org\/10.1118\/1.4837216","journal-title":"Med Phys"},{"issue":"2","key":"120_CR66","doi-asserted-by":"publisher","first-page":"6500904","DOI":"10.1109\/TMAG.2014.2322579","volume":"51","author":"RJ Deissler","year":"2015","unstructured":"Deissler RJ, Martens MA (2015) Dependence of the magnetization response on the driving field amplitude for magnetic particle imaging and spectroscopy. IEEE Trans Magn 51(2):6500904. https:\/\/doi.org\/10.1109\/TMAG.2014.2322579","journal-title":"IEEE Trans Magn"},{"issue":"6","key":"120_CR67","doi-asserted-by":"publisher","first-page":"841","DOI":"10.4218\/etrij.2017-0094","volume":"39","author":"BG Chae","year":"2017","unstructured":"Chae BG (2017) Neural network image reconstruction for magnetic particle imaging. ETRI J 39(6):841-850. https:\/\/doi.org\/10.4218\/etrij.2017-0094","journal-title":"ETRI J"},{"key":"120_CR68","doi-asserted-by":"publisher","unstructured":"Dittmer S, Kluth T, Henriksen MTR, Maass P (2020) Deep image prior for 3D magnetic particle imaging: a quantitative comparison of regularization techniques on open MPI dataset. arXiv preprint arXiv:2007.01593. https:\/\/doi.org\/10.48550\/arXiv.2007.01593","DOI":"10.48550\/arXiv.2007.01593"},{"key":"120_CR69","doi-asserted-by":"crossref","unstructured":"Baltruschat IM, Szwargulski P, Griese F, Grosser M, Werner R, Knopp T (2020) 3D-smrnet: achieving a new quality of MPI system matrix recovery by deep learning. In: Martel AL, Abolmaesumi P, Stoyanov D, Mateus D, Zuluaga MA, Zhou SK et al (eds) 23rd international conference on medical image computing and computer-assisted intervention, Lima, Peru, October 2020. Lecture notes in computer science book series, vol 12262. Springer, Lima, pp. 74-82","DOI":"10.1007\/978-3-030-59713-9_8"},{"issue":"12","key":"120_CR70","doi-asserted-by":"publisher","DOI":"10.1088\/1361-6560\/ac6e24","volume":"67","author":"YX Shang","year":"2022","unstructured":"Shang YX, Liu J, Zhang LW, Wu XJ, Zhang P, Yin L et al (2022) Deep learning for improving the spatial resolution of magnetic particle imaging. Phys Med Biol 67(12):125012. https:\/\/doi.org\/10.1088\/1361-6560\/ac6e24","journal-title":"Phys Med Biol"},{"key":"120_CR71","unstructured":"Ulyanov D, Vedaldi A, Lempitsky V (2018) Deep image prior. Paper presented at the IEEE conference on computer vision and pattern recognition, IEEE, Salt Lake City, 18-23 June 2018"},{"key":"120_CR72","doi-asserted-by":"publisher","DOI":"10.1016\/j.dib.2019.104971","volume":"28","author":"T Knopp","year":"2020","unstructured":"Knopp T, Szwargulski P, Griese F, Gr\u00e4ser M (2020) OpenMPIData: an initiative for freely accessible magnetic particle imaging data. Data Brief 28:104971. https:\/\/doi.org\/10.1016\/j.dib.2019.104971","journal-title":"Data Brief"},{"key":"120_CR73","doi-asserted-by":"publisher","unstructured":"G\u00fcng\u00f6r A, Askin B, Soydan DA, Saritas EU, Top CB, \u00c7ukur T (2021) TranSMS: transformers for super-resolution calibration in magnetic particle imaging. arXiv preprint arXiv:2111.02163. https:\/\/doi.org\/10.48550\/arXiv.2111.02163","DOI":"10.48550\/arXiv.2111.02163"},{"issue":"4","key":"120_CR74","doi-asserted-by":"publisher","first-page":"1119","DOI":"10.1002\/ima.22707","volume":"32","author":"YS Shen","year":"2022","unstructured":"Shen YS, Hu CE, Zhang P, Tian J, Hui H (2022) A novel software framework for magnetic particle imaging reconstruction. Int J Imaging Syst Technol 32(4):1119-1132. https:\/\/doi.org\/10.1002\/ima.22707","journal-title":"Int J Imaging Syst Technol"}],"container-title":["Visual Computing for Industry, Biomedicine, and Art"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s42492-022-00120-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s42492-022-00120-5\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s42492-022-00120-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,10,1]],"date-time":"2022-10-01T02:09:30Z","timestamp":1664590170000},"score":1,"resource":{"primary":{"URL":"https:\/\/vciba.springeropen.com\/articles\/10.1186\/s42492-022-00120-5"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,10,1]]},"references-count":74,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2022,12]]}},"alternative-id":["120"],"URL":"https:\/\/doi.org\/10.1186\/s42492-022-00120-5","relation":{},"ISSN":["2524-4442"],"issn-type":[{"value":"2524-4442","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,10,1]]},"assertion":[{"value":"31 May 2022","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"16 August 2022","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"1 October 2022","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Not applicable.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"All authors have approved the publication.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare that they have no competing interests.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"24"}}