{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,20]],"date-time":"2026-08-20T01:27:27Z","timestamp":1787189247865,"version":"build-2736575974"},"reference-count":19,"publisher":"Springer Science and Business Media LLC","issue":"4","license":[{"start":{"date-parts":[[2005,6,21]],"date-time":"2005-06-21T00:00:00Z","timestamp":1119312000000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/2.0\/"},{"start":{"date-parts":[[2005,6,21]],"date-time":"2005-06-21T00:00:00Z","timestamp":1119312000000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/2.0\/"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Crit Care"],"abstract":"<jats:title>Abstract<\/jats:title><jats:sec>\n                        <jats:title>Introduction<\/jats:title>\n                        <jats:p>To compare the safety and efficacy of high frequency oscillatory ventilation (HFOV) with conventional mechanical ventilation (CV) for early intervention in adult respiratory distress syndrome (ARDS), a multi-centre randomized trial in four intensive care units was conducted.<\/jats:p>\n                     <\/jats:sec><jats:sec>\n                        <jats:title>Methods<\/jats:title>\n                        <jats:p>Patients with ARDS were randomized to receive either HFOV or CV. In both treatment arms a priority was given to maintain lung volume while minimizing peak pressures. CV ventilation strategy was aimed at reducing tidal volumes. In the HFOV group, an open lung strategy was used. Respiratory and circulatory parameters were recorded and clinical outcome was determined at 30 days of follow up.<\/jats:p>\n                     <\/jats:sec><jats:sec>\n                        <jats:title>Results<\/jats:title>\n                        <jats:p>The study was prematurely stopped. Thirty-seven patients received HFOV and 24 patients CV (average APACHE II score 21 and 20, oxygenation index 25 and 18 and duration of mechanical ventilation prior to randomization 2.1 and 1.5 days, respectively). There were no statistically significant differences in survival without supplemental oxygen or on ventilator, mortality, therapy failure, or crossover. Adjustment by <jats:italic>a priori<\/jats:italic> defined baseline characteristics showed an odds ratio of 0.80 (95% CI 0.22\u20132.97) for survival without oxygen or on ventilator, and an odds ratio for mortality of 1.15 (95% CI 0.43\u20133.10) for HFOV compared with CV. The response of the oxygenation index (OI) to treatment did not differentiate between survival and death. In the HFOV group the OI response was significantly higher than in the CV group between the first and the second day. A <jats:italic>post hoc<\/jats:italic> analysis suggested that there was a relatively better treatment effect of HFOV compared with CV in patients with a higher baseline OI.<\/jats:p>\n                     <\/jats:sec><jats:sec>\n                        <jats:title>Conclusion<\/jats:title>\n                        <jats:p>No significant differences were observed, but this trial only had power to detect major differences in survival without oxygen or on ventilator. In patients with ARDS and higher baseline OI, however, there might be a treatment benefit of HFOV over CV. More research is needed to establish the efficacy of HFOV in the treatment of ARDS. We suggest that future studies are designed to allow for informative analysis in patients with higher OI.<\/jats:p>\n                     <\/jats:sec>","DOI":"10.1186\/cc3737","type":"journal-article","created":{"date-parts":[[2005,6,21]],"date-time":"2005-06-21T18:13:54Z","timestamp":1119377634000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":187,"title":["High frequency oscillatory ventilation compared with conventional mechanical ventilation in adult respiratory distress syndrome: a randomized controlled trial [ISRCTN24242669]"],"prefix":"10.1186","volume":"9","author":[{"given":"Casper W","family":"Bollen","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Gijs Th J","family":"van Well","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tony","family":"Sherry","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Richard J","family":"Beale","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sanjoy","family":"Shah","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"George","family":"Findlay","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mehran","family":"Monchi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jean-Daniel","family":"Chiche","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Norbert","family":"Weiler","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Cuno SPM","family":"Uiterwaal","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Adrianus J","family":"van Vught","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2005,6,21]]},"reference":[{"key":"3682_CR1","doi-asserted-by":"publisher","first-page":"233","DOI":"10.1186\/cc1829","volume":"7","author":"JA Frank","year":"2003","unstructured":"Frank JA, Matthay MA: Science review: mechanisms of ventilator-induced injury. Crit Care. 2003, 7: 233-241. 10.1186\/cc1829.","journal-title":"Crit Care"},{"key":"3682_CR2","doi-asserted-by":"publisher","first-page":"S276","DOI":"10.1097\/01.CCM.0000057904.62683.2B","volume":"31","author":"GD Rubenfeld","year":"2003","unstructured":"Rubenfeld GD: Epidemiology of acute lung injury. Crit Care Med. 2003, 31: S276-S284. 10.1097\/01.CCM.0000057904.62683.2B.","journal-title":"Crit Care Med"},{"key":"3682_CR3","doi-asserted-by":"publisher","first-page":"S312","DOI":"10.1097\/01.CCM.0000057909.18362.F6","volume":"31","author":"RG Brower","year":"2003","unstructured":"Brower RG, Rubenfeld GD: Lung-protective ventilation strategies in acute lung injury. Crit Care Med. 2003, 31: S312-S316. 10.1097\/01.CCM.0000057909.18362.F6.","journal-title":"Crit Care Med"},{"key":"3682_CR4","doi-asserted-by":"publisher","first-page":"906","DOI":"10.1097\/00003246-199706000-00004","volume":"25","author":"AB Froese","year":"1997","unstructured":"Froese AB: High-frequency oscillatory ventilation for adult respiratory distress syndrome: let's get it right this time!. Crit Care Med. 1997, 25: 906-908. 10.1097\/00003246-199706000-00004.","journal-title":"Crit Care Med"},{"key":"3682_CR5","first-page":"CD000104","volume":"4","author":"D Henderson-Smart","year":"2003","unstructured":"Henderson-Smart D, Bhuta T, Cools F, Offringa M: Elective high frequency oscillatory ventilation versus conventional ventilation for acute pulmonary dysfunction in preterm infants. Cochrane Database Syst Rev. 2003, 4: CD000104-","journal-title":"Cochrane Database Syst Rev"},{"key":"3682_CR6","doi-asserted-by":"publisher","first-page":"1150","DOI":"10.1164\/rccm.200306-721CP","volume":"168","author":"CW Bollen","year":"2003","unstructured":"Bollen CW, Uiterwaal CS, van Vught AJ: Cumulative metaanalysis of high-frequency versus conventional ventilation in premature neonates. Am J Respir Crit Care Med. 2003, 168: 1150-1155. 10.1164\/rccm.200306-721CP.","journal-title":"Am J Respir Crit Care Med"},{"key":"3682_CR7","doi-asserted-by":"publisher","first-page":"801","DOI":"10.1164\/rccm.2108052","volume":"166","author":"S Derdak","year":"2002","unstructured":"Derdak S, Mehta S, Stewart TE, Smith T, Rogers M, Buchman TG, Carlin B, Lowson S, Granton J: High-frequency oscillatory ventilation for acute respiratory distress syndrome in adults: a randomized, controlled trial. Am J Respir Crit Care Med. 2002, 166: 801-808. 10.1164\/rccm.2108052.","journal-title":"Am J Respir Crit Care Med"},{"key":"3682_CR8","doi-asserted-by":"publisher","first-page":"1656","DOI":"10.1007\/s00134-003-1897-6","volume":"29","author":"M David","year":"2003","unstructured":"David M, Weiler N, Heinrichs W, Neumann M, Joost T, Markstaller K, Eberle B: High-frequency oscillatory ventilation in adult acute respiratory distress syndrome. Intensive Care Med. 2003, 29: 1656-1665. 10.1007\/s00134-003-1897-6.","journal-title":"Intensive Care Med"},{"key":"3682_CR9","doi-asserted-by":"publisher","first-page":"1530","DOI":"10.1097\/00003246-199422100-00006","volume":"22","author":"JH Arnold","year":"1994","unstructured":"Arnold JH, Hanson JH, Toro-Figuero LO, Gutierrez J, Berens RJ, Anglin DL: Prospective, randomized comparison of high-frequency oscillatory ventilation and conventional mechanical ventilation in pediatric respiratory failure. Crit Care Med. 1994, 22: 1530-1539.","journal-title":"Crit Care Med"},{"key":"3682_CR10","doi-asserted-by":"publisher","first-page":"1360","DOI":"10.1097\/00003246-200107000-00011","volume":"29","author":"S Mehta","year":"2001","unstructured":"Mehta S, Lapinsky SE, Hallett DC, Merker D, Groll RJ, Cooper AB, MacDonald RJ, Stewart TE: Prospective trial of high-frequency oscillation in adults with acute respiratory distress syndrome. Crit Care Med. 2001, 29: 1360-1369. 10.1097\/00003246-200107000-00011.","journal-title":"Crit Care Med"},{"key":"3682_CR11","doi-asserted-by":"publisher","first-page":"937","DOI":"10.1097\/00003246-199706000-00008","volume":"25","author":"P Fort","year":"1997","unstructured":"Fort P, Farmer C, Westerman J, Johannigman J, Beninati W, Dolan S, Derdak S: High-frequency oscillatory ventilation for adult respiratory distress syndrome \u2013 a pilot study. Crit Care Med. 1997, 25: 937-947. 10.1097\/00003246-199706000-00008.","journal-title":"Crit Care Med"},{"key":"3682_CR12","doi-asserted-by":"publisher","first-page":"S317","DOI":"10.1097\/01.CCM.0000057910.50618.EB","volume":"31","author":"S Derdak","year":"2003","unstructured":"Derdak S: High-frequency oscillatory ventilation for acute respiratory distress syndrome in adult patients. Crit Care Med. 2003, 31: S317-S323. 10.1097\/01.CCM.0000057910.50618.EB.","journal-title":"Crit Care Med"},{"key":"3682_CR13","doi-asserted-by":"publisher","first-page":"1396","DOI":"10.1097\/00003246-199608000-00020","volume":"24","author":"AP Sarnaik","year":"1996","unstructured":"Sarnaik AP, Meert KL, Pappas MD, Simpson PM, Lieh-Lai MW, Heidemann SM: Predicting outcome in children with severe acute respiratory failure treated with high-frequency ventilation. Crit Care Med. 1996, 24: 1396-1402. 10.1097\/00003246-199608000-00020.","journal-title":"Crit Care Med"},{"key":"3682_CR14","doi-asserted-by":"crossref","unstructured":"Ventilation with lower tidal volumes as compared with traditional tidal volumes for acute lung injury and the acute respiratory distress syndrome. The Acute Respiratory Distress Syndrome Network. N Engl J Med. 2000, 342: 1301-1308. 10.1056\/NEJM200005043421801.","DOI":"10.1056\/NEJM200005043421801"},{"key":"3682_CR15","doi-asserted-by":"publisher","first-page":"1151","DOI":"10.1007\/s00134-002-1368-5","volume":"28","author":"HR van Genderingen","year":"2002","unstructured":"van Genderingen HR, van Vught JA, Jansen JR, Duval EL, Markhorst DG, Versprille A: Oxygenation index, an indicator of optimal distending pressure during high-frequency oscillatory ventilation?. Intensive Care Med. 2002, 28: 1151-1156. 10.1007\/s00134-002-1368-5.","journal-title":"Intensive Care Med"},{"key":"3682_CR16","doi-asserted-by":"publisher","first-page":"319","DOI":"10.1007\/BF01694358","volume":"18","author":"B Lachmann","year":"1992","unstructured":"Lachmann B: Open up the lung and keep the lung open. Intensive Care Med. 1992, 18: 319-321. 10.1007\/BF01694358.","journal-title":"Intensive Care Med"},{"key":"3682_CR17","doi-asserted-by":"publisher","first-page":"2s","DOI":"10.1183\/09031936.03.00420103","volume":"42","author":"JD Ricard","year":"2003","unstructured":"Ricard JD, Dreyfuss D, Saumon G: Ventilator-induced lung injury. Eur Respir J Suppl. 2003, 42: 2s-9s. 10.1183\/09031936.03.00420103.","journal-title":"Eur Respir J Suppl"},{"key":"3682_CR18","doi-asserted-by":"publisher","first-page":"518","DOI":"10.1378\/chest.126.2.518","volume":"126","author":"S Mehta","year":"2004","unstructured":"Mehta S, Granton J, MacDonald RJ, Bowman D, Matte-Martyn A, Bachman T, Smith T, Stewart TE: High-frequency oscillatory ventilation in adults: the Toronto experience. Chest. 2004, 126: 518-527. 10.1378\/chest.126.2.518.","journal-title":"Chest"},{"key":"3682_CR19","first-page":"CD004085","volume-title":"Cochrane Database Syst Rev","author":"H Wunsch","year":"2004","unstructured":"Wunsch H, Mapstone J: High-frequency ventilation versus conventional ventilation for treatment of acute lung injury and acute respiratory distress syndrome. Cochrane Database Syst Rev. 2004, CD004085-"}],"container-title":["Critical Care"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/cc3737.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/cc3737\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/cc3737.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,10,7]],"date-time":"2024-10-07T12:07:13Z","timestamp":1728302833000},"score":1,"resource":{"primary":{"URL":"https:\/\/ccforum.biomedcentral.com\/articles\/10.1186\/cc3737"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2005,6,21]]},"references-count":19,"journal-issue":{"issue":"4","published-online":{"date-parts":[[2005,8]]}},"alternative-id":["3682"],"URL":"https:\/\/doi.org\/10.1186\/cc3737","relation":{},"ISSN":["1364-8535"],"issn-type":[{"value":"1364-8535","type":"electronic"}],"subject":[],"published":{"date-parts":[[2005,6,21]]},"assertion":[{"value":"19 December 2004","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"22 April 2005","order":2,"name":"revised","label":"Revised","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"12 May 2005","order":3,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"21 June 2005","order":4,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}}],"article-number":"R430"}}