{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,29]],"date-time":"2026-08-29T13:22:58Z","timestamp":1788009778987,"version":"build-2784847793"},"reference-count":40,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2022,3,22]],"date-time":"2022-03-22T00:00:00Z","timestamp":1647907200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2022,3,22]],"date-time":"2022-03-22T00:00:00Z","timestamp":1647907200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["J Orthop Traumatol"],"published-print":{"date-parts":[[2022,12]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:sec>\n                <jats:title>Background<\/jats:title>\n                <jats:p>Total hip arthroplasty (THA) is the most successful orthopaedic surgery of the past century. The current study aimed to compare the accuracy of digital planning using 2D versus 3D templating.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Materials and methods<\/jats:title>\n                <jats:p>Ninety-five THAs in 90 patients were included in the current study. Pre- and post-operative X-rays (in two planes) and low-dose rotation computed tomography scans from hip to foot were performed. Paired <jats:italic>t<\/jats:italic>-test and regression analyses were conducted to compare 2D and 3D templating accuracy of the definitive implant.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Results<\/jats:title>\n                <jats:p>Cup size planned both with 2D (<jats:italic>p<\/jats:italic>\u2009&lt;\u20090.0001) and 3D (<jats:italic>p<\/jats:italic>\u2009=\u20090.012) templating was significantly different from the definitively used cup size. The difference between the 2D-planned and implanted stem size (<jats:italic>p<\/jats:italic>\u2009&lt;\u20090.0001) was statistically significant. In contrast, there were no significant differences in the 3D-planned and implanted stem size (<jats:italic>p<\/jats:italic>\u2009=\u20090.181). Three-dimensional templating showed significantly higher accuracy than 2D templating in terms of cup size (1.1\u2009\u00b1\u20091.4 versus 1.7\u2009\u00b1\u20091.8; <jats:italic>p<\/jats:italic>\u2009=\u20090.007) and stem size (0.3\u2009\u00b1\u20090.6 versus 0.7\u2009\u00b1\u20090.7; <jats:italic>p<\/jats:italic>\u2009&lt;\u20090.0001).<\/jats:p>\n                <jats:p>With increasing body mass index (BMI), 2D templating of the stem became more inaccurate (<jats:italic>p<\/jats:italic>\u2009=\u20090.041). Remarkably, 3D templating remained accurate for all components (stem, <jats:italic>p<\/jats:italic>\u2009=\u20090.533; cup, <jats:italic>p<\/jats:italic>\u2009=\u20090.479) despite increasing BMI.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Conclusion<\/jats:title>\n                <jats:p>Despite extended planning time and increased exposure to radiation, 3D-based planning showed higher accuracy than 2D templating, especially in obese patients. On the basis of our results, we believe that 3D-based pre-operative planning in THA is justifiable and beneficial in patients with increased BMI.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Level of Evidence<\/jats:title>\n                <jats:p>III.<\/jats:p>\n              <\/jats:sec>","DOI":"10.1186\/s10195-022-00634-x","type":"journal-article","created":{"date-parts":[[2022,3,22]],"date-time":"2022-03-22T17:05:32Z","timestamp":1647968732000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":24,"title":["Pre-operative templating in THA using a short stem system: precision and accuracy of 2D versus 3D planning method"],"prefix":"10.1186","volume":"23","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-0786-8956","authenticated-orcid":false,"given":"Patrick","family":"Reinbacher","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Maria Anna","family":"Smolle","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Joerg","family":"Friesenbichler","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Alexander","family":"Draschl","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Andreas","family":"Leithner","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Werner","family":"Maurer-Ertl","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2022,3,22]]},"reference":[{"key":"634_CR1","doi-asserted-by":"publisher","first-page":"1508","DOI":"10.1016\/S0140-6736(07)60457-7","volume":"370","author":"ID Learmonth","year":"2007","unstructured":"Learmonth ID, Young C, Rorabeck C (2007) The operation of the century: total hip replacement. Lancet 370:1508\u20131519. https:\/\/doi.org\/10.1016\/S0140-6736(07)60457-7","journal-title":"Lancet"},{"key":"634_CR2","first-page":"243","volume":"162","author":"JS Siopack","year":"1995","unstructured":"Siopack JS, Jergesen HE (1995) Total hip arthroplasty. West J Med 162:243\u2013249","journal-title":"West J Med"},{"key":"634_CR3","doi-asserted-by":"publisher","DOI":"10.1016\/S0140-6736(18)31777-X","author":"RJ Ferguson","year":"2018","unstructured":"Ferguson RJ, Palmer AJ, Taylor A et\u00a0al (2018) Hip replacement. Lancet (London, England). https:\/\/doi.org\/10.1016\/S0140-6736(18)31777-X","journal-title":"Lancet (London, England)"},{"key":"634_CR4","doi-asserted-by":"publisher","first-page":"1424","DOI":"10.1016\/S0140-6736(17)30059-4","volume":"389","author":"LE Bayliss","year":"2017","unstructured":"Bayliss LE, Culliford D, Monk AP et\u00a0al (2017) The effect of patient age at intervention on risk of implant revision after total replacement of the hip or knee: a population-based cohort study. Lancet 389:1424\u20131430. https:\/\/doi.org\/10.1016\/S0140-6736(17)30059-4","journal-title":"Lancet"},{"key":"634_CR5","doi-asserted-by":"publisher","first-page":"534","DOI":"10.1302\/0301-620X.77B4.7615595","volume":"77","author":"RG Geesink","year":"1995","unstructured":"Geesink RG, Hoefnagels NH (1995) Six-year results of hydroxyapatite-coated total hip replacement. J Bone Joint Surg. 77:534\u2013547. https:\/\/doi.org\/10.1302\/0301-620X.77B4.7615595","journal-title":"J Bone Joint Surg."},{"key":"634_CR6","doi-asserted-by":"publisher","first-page":"157","DOI":"10.1002\/jor.1100170203","volume":"17","author":"H McKellop","year":"1999","unstructured":"McKellop H, Shen FW, Lu B et\u00a0al (1999) Development of an extremely wear-resistant ultra high molecular weight polyethylene for total hip replacements. J Orthop Res 17:157\u2013167. https:\/\/doi.org\/10.1002\/jor.1100170203","journal-title":"J Orthop Res"},{"key":"634_CR7","doi-asserted-by":"publisher","first-page":"626","DOI":"10.1302\/2058-5241.4.180075","volume":"4","author":"A Colombi","year":"2019","unstructured":"Colombi A, Schena D, Castelli CC (2019) Total hip arthroplasty planning. EFORT Open Rev 4:626\u2013632. https:\/\/doi.org\/10.1302\/2058-5241.4.180075","journal-title":"EFORT Open Rev"},{"key":"634_CR8","doi-asserted-by":"publisher","first-page":"1767","DOI":"10.1007\/s00264-012-1532-7","volume":"36","author":"F Schmidutz","year":"2012","unstructured":"Schmidutz F, Steinbr\u00fcck A, Wanke-Jellinek L et\u00a0al (2012) The accuracy of digital templating: a comparison of short-stem total hip arthroplasty and conventional total hip arthroplasty. Int Orthop (SICOT) 36:1767\u20131772. https:\/\/doi.org\/10.1007\/s00264-012-1532-7","journal-title":"Int Orthop (SICOT)"},{"key":"634_CR9","doi-asserted-by":"publisher","first-page":"529","DOI":"10.1016\/j.arth.2009.04.011","volume":"25","author":"P Gamble","year":"2010","unstructured":"Gamble P, de Beer J, Petruccelli D et\u00a0al (2010) The accuracy of digital templating in uncemented total hip arthroplasty. J Arthroplasty 25:529\u2013532. https:\/\/doi.org\/10.1016\/j.arth.2009.04.011","journal-title":"J Arthroplasty"},{"key":"634_CR10","doi-asserted-by":"publisher","DOI":"10.1007\/s00402-021-03836-w","author":"D Dammerer","year":"2021","unstructured":"Dammerer D, Keiler A, Herrnegger S et\u00a0al (2021) Accuracy of digital templating of uncemented total hip arthroplasty at a certified arthroplasty center: a retrospective comparative study. Arch Orthop Trauma Surg. https:\/\/doi.org\/10.1007\/s00402-021-03836-w","journal-title":"Arch Orthop Trauma Surg"},{"key":"634_CR11","doi-asserted-by":"publisher","first-page":"150","DOI":"10.1016\/S1001-9294(15)30039-0","volume":"30","author":"H-B Si","year":"2015","unstructured":"Si H-B, Zeng Y, Cao F et\u00a0al (2015) Accuracy of a simple digital templating in primary uncemented total hip arthroplasty. Chin Med Sci J 30:150\u2013155. https:\/\/doi.org\/10.1016\/S1001-9294(15)30039-0","journal-title":"Chin Med Sci J"},{"key":"634_CR12","doi-asserted-by":"publisher","first-page":"949","DOI":"10.1016\/j.jbiomech.2012.12.010","volume":"46","author":"TL Norman","year":"2013","unstructured":"Norman TL, Shultz T, Noble G et\u00a0al (2013) Bone creep and short and long term subsidence after cemented stem total hip arthroplasty (THA). J Biomech 46:949\u2013955. https:\/\/doi.org\/10.1016\/j.jbiomech.2012.12.010","journal-title":"J Biomech"},{"key":"634_CR13","unstructured":"Van EE, Hendrickx M, Scheerlinck T (2010) Uncemented femoral stem design influences the occurrence rate of postoperative fractures after primary hip arthroplasty: a comparison of the Image and Profile stems. Acta orthopaedica Belgica 76"},{"key":"634_CR14","doi-asserted-by":"publisher","DOI":"10.1186\/s13018-021-02584-2","author":"LFU G\u00f3mez","year":"2021","unstructured":"G\u00f3mez LFU, Gait\u00e1n-Lee H, Duarte MA et\u00a0al (2021) Precision and accuracy of pre-surgical planning of non-cemented total hip replacement with calibrated digital images and acetates. J Orthop Surg Res. https:\/\/doi.org\/10.1186\/s13018-021-02584-2","journal-title":"J Orthop Surg Res"},{"key":"634_CR15","unstructured":"H. Blackley, G. Howell, C. Rorabeck (2000) Planning and management of the difficult primary hip replacement: preoperative planning and technical considerations. undefined"},{"key":"634_CR16","doi-asserted-by":"publisher","first-page":"382","DOI":"10.1302\/0301-620x.80b3.7764","volume":"80","author":"S Eggli","year":"1998","unstructured":"Eggli S, Pisan M, M\u00fcller ME (1998) The value of preoperative planning for total hip arthroplasty. J Bone Joint Surg 80:382\u2013390. https:\/\/doi.org\/10.1302\/0301-620x.80b3.7764","journal-title":"J Bone Joint Surg"},{"key":"634_CR17","doi-asserted-by":"publisher","first-page":"442","DOI":"10.1007\/bf00350537","volume":"16","author":"V Hoikka","year":"1987","unstructured":"Hoikka V, Paavilainen T, Lindholm TS et\u00a0al (1987) Measurement and restoration of equality in length of the lower limbs in total hip replacement. Skeletal Radiol 16:442\u2013446. https:\/\/doi.org\/10.1007\/bf00350537","journal-title":"Skeletal Radiol"},{"key":"634_CR18","doi-asserted-by":"publisher","first-page":"263","DOI":"10.1007\/s00402-018-3080-0","volume":"139","author":"LA Holzer","year":"2019","unstructured":"Holzer LA, Scholler G, Wagner S et\u00a0al (2019) The accuracy of digital templating in uncemented total hip arthroplasty. Arch Orthop Trauma Surg 139:263\u2013268. https:\/\/doi.org\/10.1007\/s00402-018-3080-0","journal-title":"Arch Orthop Trauma Surg"},{"key":"634_CR19","doi-asserted-by":"publisher","first-page":"747","DOI":"10.1007\/s11999-009-1045-x","volume":"468","author":"X Flecher","year":"2010","unstructured":"Flecher X, Pearce O, Parratte S et\u00a0al (2010) Custom cementless stem improves hip function in young patients at 15-year followup. Clin Orthop Relat Res 468:747\u2013755. https:\/\/doi.org\/10.1007\/s11999-009-1045-x","journal-title":"Clin Orthop Relat Res"},{"key":"634_CR20","doi-asserted-by":"publisher","first-page":"17","DOI":"10.1054\/arth.2002.33263","volume":"17","author":"RB Bourne","year":"2002","unstructured":"Bourne RB, Rorabeck CH (2002) Soft tissue balancing: the hip. J Arthroplasty 17:17\u201322. https:\/\/doi.org\/10.1054\/arth.2002.33263","journal-title":"J Arthroplasty"},{"key":"634_CR21","doi-asserted-by":"publisher","first-page":"414","DOI":"10.1016\/j.arth.2004.01.016","volume":"20","author":"I Asayama","year":"2005","unstructured":"Asayama I, Chamnongkich S, Simpson KJ et\u00a0al (2005) Reconstructed hip joint position and abductor muscle strength after total hip arthroplasty. J Arthroplasty 20:414\u2013420. https:\/\/doi.org\/10.1016\/j.arth.2004.01.016","journal-title":"J Arthroplasty"},{"key":"634_CR22","doi-asserted-by":"publisher","first-page":"333","DOI":"10.1302\/0301-620X.91B3.21390","volume":"91","author":"E Sariali","year":"2009","unstructured":"Sariali E, Mouttet A, Pasquier G et\u00a0al (2009) Accuracy of reconstruction of the hip using computerised three-dimensional pre-operative planning and a cementless modular neck. J Bone Joint Surg 91:333\u2013340. https:\/\/doi.org\/10.1302\/0301-620X.91B3.21390","journal-title":"J Bone Joint Surg"},{"key":"634_CR23","doi-asserted-by":"publisher","first-page":"1028","DOI":"10.3928\/01477447-20121120-03","volume":"35","author":"K Issa","year":"2012","unstructured":"Issa K, Pivec R, Boyd B et\u00a0al (2012) Comparing the accuracy of radiographic preoperative digital templating for a second- versus a first-generation THA stem. Orthopedics 35:1028\u20131034. https:\/\/doi.org\/10.3928\/01477447-20121120-03","journal-title":"Orthopedics"},{"key":"634_CR24","doi-asserted-by":"publisher","first-page":"151","DOI":"10.1016\/j.otsr.2011.09.023","volume":"98","author":"E Sariali","year":"2012","unstructured":"Sariali E, Mauprivez R, Khiami F et\u00a0al (2012) Accuracy of the preoperative planning for cementless total hip arthroplasty. A randomised comparison between three-dimensional computerised planning and conventional templating. Orthop Traumatol Surg Res 98:151\u2013158. https:\/\/doi.org\/10.1016\/j.otsr.2011.09.023","journal-title":"Orthop Traumatol Surg Res"},{"key":"634_CR25","first-page":"273","volume":"57","author":"DR Whiddon","year":"2008","unstructured":"Whiddon DR, Bono JV (2008) Digital templating in total hip arthroplasty. Instr Course Lect 57:273\u2013279","journal-title":"Instr Course Lect"},{"key":"634_CR26","doi-asserted-by":"publisher","first-page":"1149","DOI":"10.1016\/j.arth.2020.10.016","volume":"36","author":"M Brenneis","year":"2021","unstructured":"Brenneis M, Braun S, van Drongelen S et\u00a0al (2021) Accuracy of preoperative templating in total hip arthroplasty with special focus on stem morphology: a randomized comparison between common digital and three-dimensional planning using biplanar radiographs. J Arthroplasty 36:1149\u20131155. https:\/\/doi.org\/10.1016\/j.arth.2020.10.016","journal-title":"J Arthroplasty"},{"key":"634_CR27","doi-asserted-by":"publisher","first-page":"531","DOI":"10.1016\/j.otsr.2017.03.001","volume":"103","author":"D Mainard","year":"2017","unstructured":"Mainard D, Barbier O, Knafo Y et\u00a0al (2017) Accuracy and reproducibility of preoperative three-dimensional planning for total hip arthroplasty using biplanar low-dose radiographs: a pilot study. Orthop Traumatol Surg Res 103:531\u2013536. https:\/\/doi.org\/10.1016\/j.otsr.2017.03.001","journal-title":"Orthop Traumatol Surg Res"},{"key":"634_CR28","doi-asserted-by":"publisher","first-page":"231","DOI":"10.1016\/8756-3282(93)90146-2","volume":"14","author":"LD Dorr","year":"1993","unstructured":"Dorr LD, Faugere M-C, Mackel AM et\u00a0al (1993) Structural and cellular assessment of bone quality of proximal femur. Bone 14:231\u2013242. https:\/\/doi.org\/10.1016\/8756-3282(93)90146-2","journal-title":"Bone"},{"key":"634_CR29","doi-asserted-by":"publisher","first-page":"289","DOI":"10.1016\/j.artd.2016.09.003","volume":"3","author":"FA Osmani","year":"2017","unstructured":"Osmani FA, Thakkar S, Ramme A et\u00a0al (2017) Variance in predicted cup size by 2-dimensional vs 3-dimensional computerized tomography-based templating in primary total hip arthroplasty. Arthroplast Today 3:289\u2013293. https:\/\/doi.org\/10.1016\/j.artd.2016.09.003","journal-title":"Arthroplast Today"},{"key":"634_CR30","doi-asserted-by":"publisher","first-page":"371","DOI":"10.1016\/S1350-4533(03)00018-3","volume":"25","author":"M Viceconti","year":"2003","unstructured":"Viceconti M, Lattanzi R, Antonietti B et\u00a0al (2003) CT-based surgical planning software improves the accuracy of total hip replacement preoperative planning. Med Eng Phys 25:371\u2013377. https:\/\/doi.org\/10.1016\/S1350-4533(03)00018-3","journal-title":"Med Eng Phys"},{"key":"634_CR31","doi-asserted-by":"publisher","first-page":"601","DOI":"10.1016\/j.arth.2017.08.031","volume":"33","author":"Y Wako","year":"2018","unstructured":"Wako Y, Nakamura J, Miura M et\u00a0al (2018) Interobserver and intraobserver reliability of three-dimensional preoperative planning software in total hip arthroplasty. J Arthroplasty 33:601\u2013607. https:\/\/doi.org\/10.1016\/j.arth.2017.08.031","journal-title":"J Arthroplasty"},{"key":"634_CR32","doi-asserted-by":"publisher","first-page":"711","DOI":"10.1007\/s00264-013-2166-0","volume":"38","author":"K Kuroda","year":"2014","unstructured":"Kuroda K, Kabata T, Maeda T et\u00a0al (2014) The value of computed tomography based navigation in revision total hip arthroplasty. Int Orthop 38:711\u2013716. https:\/\/doi.org\/10.1007\/s00264-013-2166-0","journal-title":"Int Orthop"},{"key":"634_CR33","doi-asserted-by":"publisher","unstructured":"(2013) Obesity and total joint arthroplasty: a literature based review. J Arthroplasty 28:714\u2013721. Doi: https:\/\/doi.org\/10.1016\/j.arth.2013.02.011","DOI":"10.1016\/j.arth.2013.02.011"},{"key":"634_CR34","doi-asserted-by":"publisher","first-page":"442","DOI":"10.1503\/cjs.017318","volume":"62","author":"M Tohidi","year":"2019","unstructured":"Tohidi M, Brogly SB, Lajkosz K et\u00a0al (2019) Ten-year risk of complication and mortality after total hip arthroplasty in morbidly obese patients: a population study. Can J Surg 62:442\u2013449. https:\/\/doi.org\/10.1503\/cjs.017318","journal-title":"Can J Surg"},{"issue":"121\u201335","key":"634_CR35","doi-asserted-by":"publisher","first-page":"ix","DOI":"10.1016\/j.pop.2015.10.001","volume":"43","author":"KB Smith","year":"2016","unstructured":"Smith KB, Smith MS (2016) Obesity statistics. Prim Care 43(121\u201335):ix. https:\/\/doi.org\/10.1016\/j.pop.2015.10.001","journal-title":"Prim Care"},{"key":"634_CR36","doi-asserted-by":"publisher","first-page":"31","DOI":"10.1016\/j.joca.2019.10.005","volume":"28","author":"JR Onggo","year":"2020","unstructured":"Onggo JR, Onggo JD, de Steiger R et\u00a0al (2020) Greater risks of complications, infections, and revisions in the obese versus non-obese total hip arthroplasty population of 2,190,824 patients: a meta-analysis and systematic review. Osteoarthr Cartil 28:31\u201344. https:\/\/doi.org\/10.1016\/j.joca.2019.10.005","journal-title":"Osteoarthr Cartil"},{"key":"634_CR37","doi-asserted-by":"publisher","first-page":"2140","DOI":"10.2106\/JBJS.18.00120","volume":"100","author":"S Mouchti","year":"2018","unstructured":"Mouchti S, Whitehouse MR, Sayers A et\u00a0al (2018) The association of body mass index with risk of long-term revision and 90-day mortality following primary total hip replacement: findings from the national joint registry for England, Wales, Northern Ireland and the Isle Of Man. J Bone Joint Surg Am 100:2140\u20132152. https:\/\/doi.org\/10.2106\/JBJS.18.00120","journal-title":"J Bone Joint Surg Am"},{"key":"634_CR38","doi-asserted-by":"publisher","first-page":"947","DOI":"10.1016\/j.arth.2019.01.027","volume":"34","author":"Q Wang","year":"2019","unstructured":"Wang Q, Goswami K, Shohat N et\u00a0al (2019) Longer operative time results in a higher rate of subsequent periprosthetic joint infection in patients undergoing primary joint arthroplasty. J Arthroplasty 34:947\u2013953. https:\/\/doi.org\/10.1016\/j.arth.2019.01.027","journal-title":"J Arthroplasty"},{"key":"634_CR39","doi-asserted-by":"publisher","first-page":"1513","DOI":"10.1302\/0301-620X.88B11.17986","volume":"88","author":"J Henckel","year":"2006","unstructured":"Henckel J, Richards R, Lozhkin K et\u00a0al (2006) Very low-dose computed tomography for planning and outcome measurement in knee replacement. The imperial knee protocol. J Bone Joint Surg 88:1513\u20131518. https:\/\/doi.org\/10.1302\/0301-620X.88B11.17986","journal-title":"J Bone Joint Surg"},{"key":"634_CR40","doi-asserted-by":"publisher","first-page":"406","DOI":"10.1016\/j.ejrad.2009.11.024","volume":"78","author":"A Huppertz","year":"2011","unstructured":"Huppertz A, Radmer S, Asbach P et\u00a0al (2011) Computed tomography for preoperative planning in minimal-invasive total hip arthroplasty: radiation exposure and cost analysis. Eur J Radiol 78:406\u2013413. https:\/\/doi.org\/10.1016\/j.ejrad.2009.11.024","journal-title":"Eur J Radiol"}],"container-title":["Journal of Orthopaedics and Traumatology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s10195-022-00634-x.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s10195-022-00634-x\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s10195-022-00634-x.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,3,22]],"date-time":"2022-03-22T17:05:41Z","timestamp":1647968741000},"score":1,"resource":{"primary":{"URL":"https:\/\/jorthoptraumatol.springeropen.com\/articles\/10.1186\/s10195-022-00634-x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,3,22]]},"references-count":40,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2022,12]]}},"alternative-id":["634"],"URL":"https:\/\/doi.org\/10.1186\/s10195-022-00634-x","relation":{},"ISSN":["1590-9921","1590-9999"],"issn-type":[{"value":"1590-9921","type":"print"},{"value":"1590-9999","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,3,22]]},"assertion":[{"value":"16 May 2021","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"26 February 2022","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"22 March 2022","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The present study has been approved by the institutional review board (IRB-No. 28\u2013152 ex 15\/16). All patients gave their written informed consent prior to being included in this study.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"As no patient-identifying information is made public, no specific consent for publication was obtained from patients.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"Prof. Leithner receives institutional, educational grants from Johnson & Johnson, Alphamed, Implantec and Globus, outside the submitted work. The remaining authors have no competing interests to declare.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"16"}}