{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,17]],"date-time":"2026-09-17T12:27:56Z","timestamp":1789648076203,"version":"4.0.0"},"reference-count":29,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2022,9,1]],"date-time":"2022-09-01T00:00:00Z","timestamp":1661990400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2022,9,1]],"date-time":"2022-09-01T00:00:00Z","timestamp":1661990400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["J Orthop Traumatol"],"published-print":{"date-parts":[[2022,12]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:sec>\n                <jats:title>Background<\/jats:title>\n                <jats:p>Percutaneous pedicle screw (PPS) placement is a key step in several minimally invasive spinal surgery (MISS) procedures. Traditional technique for PPS makes use of C-arm fluoroscopy assistance (FA). More recently, newer intraoperative imaging techniques have been developed for PPS, including CT-guided navigation (CTNav). The aim of this study was to compare FA and CTNav techniques for PPS with regard to accuracy, complications, and radiation dosage.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Materials and methods<\/jats:title>\n                <jats:p>A total of 192 patients with degenerative lumbar spondylolisthesis and canal stenosis who underwent MISS posterior fusion\u2009\u00b1\u2009interbody fusion through transforaminal approach (TLIF) were retrospectively reviewed. Pedicle screws were placed percutaneously using either standard C-arm fluoroscopy guidance (FA group) or CT navigation (CTNav group). Intraoperative effective dose (ED, mSv) was measured. Screw placement accuracy was assessed postoperatively on a CT scan using Gertzbein and Robbins classification (grades A\u2013E). Oswestry disability index (ODI) and visual analog scale (VAS) scores were compared in both groups before and after surgery.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Results<\/jats:title>\n                <jats:p>A total of 101 and 91 procedures were performed with FA (FA group) and CTNav approach (CTNav group), respectively. Median age was 61\u00a0years in both groups, and the most commonly treated level was L4\u2013L5. Median ED received from patients was 1.504\u00a0mSv (0.494\u20134.406) in FA technique and 21.130\u00a0mSv (10.840\u201330.390) in CTNav approach (<jats:italic>p<\/jats:italic>\u2009&lt;\u20090.001). Percentage of grade A and B screws was significantly higher for the CTNav group (96.4% versus 92%, <jats:italic>p<\/jats:italic>\u2009&lt;\u20090.001), whereas there were 16 grade E screws in the FA group and 0 grade E screws in the CTNav group (<jats:italic>p<\/jats:italic>\u2009&lt;\u20090.001). A total of seven and five complications were reported in the FA and CTNav group, respectively (<jats:italic>p<\/jats:italic>\u2009=\u20090.771).<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Conclusions<\/jats:title>\n                <jats:p>CTNav technique increases accuracy of pedicle screw placement compared with FA technique without affecting operative time. Nevertheless, no significant difference was noted in terms of reoperation rate due to screw malpositioning between CTNav and FA techniques. Radiation exposure of patients was significantly higher with CTNav technique.<\/jats:p>\n                <jats:p><jats:bold>Level of Evidence:<\/jats:bold> Level 3.<\/jats:p>\n              <\/jats:sec>","DOI":"10.1186\/s10195-022-00661-8","type":"journal-article","created":{"date-parts":[[2022,9,1]],"date-time":"2022-09-01T10:04:50Z","timestamp":1662026690000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":34,"title":["Intraoperative CT-guided navigation versus fluoroscopy for percutaneous pedicle screw placement in 192 patients: a comparative analysis"],"prefix":"10.1186","volume":"23","author":[{"given":"Giuseppe","family":"La Rocca","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Edoardo","family":"Mazzucchi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Fabrizio","family":"Pignotti","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Luigi Aurelio","family":"Nasto","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Gianluca","family":"Galieri","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Alessandro","family":"Olivi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Vincenzo","family":"De Santis","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Pierluigi","family":"Rinaldi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Enrico","family":"Pola","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Giovanni","family":"Sabatino","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2022,9,1]]},"reference":[{"key":"661_CR1","doi-asserted-by":"publisher","first-page":"320","DOI":"10.1007\/s00586-013-2962-7","volume":"23","author":"DT Cawley","year":"2014","unstructured":"Cawley DT, Alexander M, Morris S (2014) Multifidus innervation and muscle assessment post-spinal surgery. Eur Spine J 23:320\u2013327","journal-title":"Eur Spine J"},{"key":"661_CR2","first-page":"3032","volume":"18","author":"H Peng","year":"2019","unstructured":"Peng H, Tang G, Zhuang X, Lu S, Bai Y, Xu L (2019) Minimally invasive spine surgery decreases postoperative pain and inflammation for patients with lumbar spinal stenosis. Exp Ther Med 18:3032\u20133036","journal-title":"Exp Ther Med"},{"key":"661_CR3","doi-asserted-by":"publisher","first-page":"1082","DOI":"10.1016\/j.spinee.2017.04.002","volume":"17","author":"MH Wu","year":"2017","unstructured":"Wu MH, Dubey NK, Li YY, Lee CY, Cheng CC, Shi CS, Huang TJ (2017) Comparison of minimally invasive spine surgery using intraoperative computed tomography integrated navigation, fluoroscopy, and conventional open surgery for lumbar spondylolisthesis: a prospective registry-based cohort study. Spine J 17:1082\u20131090","journal-title":"Spine J"},{"key":"661_CR4","doi-asserted-by":"publisher","first-page":"1259","DOI":"10.1007\/s00701-018-3541-9","volume":"160","author":"GM Della Pepa","year":"2018","unstructured":"Della Pepa GM, Mattogno PP, La Rocca G, Sabatino G, Olivi A, Ricciardi L, Polli FM (2018) Real-time intraoperative contrast-enhanced ultrasound (CEUS) in vascularized spinal tumors: a technical note. Acta Neurochir 160:1259\u20131263","journal-title":"Acta Neurochir"},{"key":"661_CR5","doi-asserted-by":"publisher","first-page":"57","DOI":"10.1016\/j.ijscr.2015.06.032","volume":"15","author":"M Visocchi","year":"2015","unstructured":"Visocchi M, La Rocca G, Signorelli F, Roselli R, Jun Z, Spallone A (2015) 10 Levels thoracic no-intrumented laminectomy for huge spontaneous spinal subdural hematoma removal. Report of the first case and literature review. Int J Surg Case Rep 15:57\u201362","journal-title":"Int J Surg Case Rep"},{"key":"661_CR6","doi-asserted-by":"publisher","first-page":"232","DOI":"10.1111\/j.1469-7580.2006.00686.x","volume":"210","author":"R Chakraverty","year":"2007","unstructured":"Chakraverty R, Pynsent P, Isaacs K (2007) Which spinal levels are identified by palpation of the iliac crests and the posterior superior iliac spines? J Anat 210:232\u2013236","journal-title":"J Anat"},{"key":"661_CR7","doi-asserted-by":"publisher","first-page":"309","DOI":"10.4184\/asj.2018.12.2.309","volume":"12","author":"T Dusad","year":"2018","unstructured":"Dusad T, Kundnani V, Dutta S, Patel A, Mehta G, Singh M (2018) Comparative prospective study reporting intraoperative parameters, pedicle screw perforation, and radiation exposure in navigation-guided versus non-navigated fluoroscopy-assisted minimal invasive transforaminal lumbar interbody fusion. Asian Spine J 12:309\u2013316","journal-title":"Asian Spine J"},{"key":"661_CR8","doi-asserted-by":"publisher","first-page":"2117","DOI":"10.1088\/0031-9155\/37\/11\/008","volume":"37","author":"JC Le Heron","year":"1992","unstructured":"Le Heron JC (1992) Estimation of effective dose to the patient during medical x-ray examinations from measurements of the dose-area product. Phys Med Biol 37:2117\u20132126","journal-title":"Phys Med Biol"},{"key":"661_CR9","doi-asserted-by":"publisher","first-page":"E850","DOI":"10.1097\/BRS.0000000000000363","volume":"39","author":"C O'Donnell","year":"2014","unstructured":"O\u2019Donnell C, Maertens A, Bompadre V, Wagner TA, Krengel W 3rd (2014) Comparative radiation exposure using standard fluoroscopy versus cone-beam computed tomography for posterior instrumented fusion in adolescent idiopathic scoliosis. Spine 39:E850\u2013E855","journal-title":"Spine"},{"key":"661_CR10","doi-asserted-by":"publisher","first-page":"E306","DOI":"10.1097\/BRS.0b013e318281d70b","volume":"38","author":"J Lange","year":"2013","unstructured":"Lange J, Karellas A, Street J, Eck JC, Lapinsky A, Connolly PJ, Dipaola CP (2013) Estimating the effective radiation dose imparted to patients by intraoperative cone-beam computed tomography in thoracolumbar spinal surgery. Spine 38:E306\u2013E312","journal-title":"Spine"},{"key":"661_CR11","doi-asserted-by":"publisher","first-page":"52","DOI":"10.1097\/BSD.0b013e318211fdea","volume":"25","author":"K Abul-Kasim","year":"2012","unstructured":"Abul-Kasim K, Soderberg M, Selariu E, Gunnarsson M, Kherad M, Ohlin A (2012) Optimization of radiation exposure and image quality of the cone-beam O-arm intraoperative imaging system in spinal surgery. J Spinal Disord Tech 25:52\u201358","journal-title":"J Spinal Disord Tech"},{"key":"661_CR12","doi-asserted-by":"publisher","first-page":"E1580","DOI":"10.1097\/BRS.0b013e318271b1fa","volume":"37","author":"E Van de Kelft","year":"2012","unstructured":"Van de Kelft E, Costa F, Van der Planken D, Schils F (2012) A prospective multicenter registry on the accuracy of pedicle screw placement in the thoracic, lumbar, and sacral levels with the use of the O-arm imaging system and StealthStation Navigation. Spine 37:E1580\u2013E1587","journal-title":"Spine"},{"key":"661_CR13","doi-asserted-by":"publisher","first-page":"11","DOI":"10.1097\/00007632-199001000-00004","volume":"15","author":"SD Gertzbein","year":"1990","unstructured":"Gertzbein SD, Robbins SE (1990) Accuracy of pedicular screw placement in vivo. Spine 15:11\u201314","journal-title":"Spine"},{"key":"661_CR14","doi-asserted-by":"publisher","first-page":"890","DOI":"10.1038\/s41598-017-19054-7","volume":"8","author":"Y Fan","year":"2018","unstructured":"Fan Y, Du Peng J, Liu JJ, Zhang JN, Liu SC, Hao DJ (2018) Radiological and clinical differences among three assisted technologies in pedicle screw fixation of adult degenerative scoliosis. Sci Rep 8:890","journal-title":"Sci Rep"},{"key":"661_CR15","doi-asserted-by":"publisher","first-page":"247","DOI":"10.1007\/s00586-011-2011-3","volume":"21","author":"ID Gelalis","year":"2012","unstructured":"Gelalis ID, Paschos NK, Pakos EE, Politis AN, Arnaoutoglou CM, Karageorgos AC, Ploumis A, Xenakis TA (2012) Accuracy of pedicle screw placement: a systematic review of prospective in vivo studies comparing free hand, fluoroscopy guidance and navigation techniques. Eur Spine J 21:247\u2013255","journal-title":"Eur Spine J"},{"key":"661_CR16","doi-asserted-by":"publisher","first-page":"1254","DOI":"10.1097\/00007632-199706010-00018","volume":"22","author":"T Laine","year":"1997","unstructured":"Laine T, Schlenzka D, Makitalo K, Tallroth K, Nolte LP, Visarius H (1997) Improved accuracy of pedicle screw insertion with computer-assisted surgery. A prospective clinical trial of 30 patients. Spine 22:1254\u20131258","journal-title":"Spine"},{"key":"661_CR17","doi-asserted-by":"publisher","first-page":"606","DOI":"10.1097\/00007632-200003010-00012","volume":"25","author":"LP Amiot","year":"2000","unstructured":"Amiot LP, Lang K, Putzier M, Zippel H, Labelle H (2000) Comparative results between conventional and computer-assisted pedicle screw installation in the thoracic, lumbar, and sacral spine. Spine 25:606\u2013614","journal-title":"Spine"},{"key":"661_CR18","doi-asserted-by":"publisher","first-page":"1320","DOI":"10.1097\/00007632-199606010-00008","volume":"21","author":"WH Castro","year":"1996","unstructured":"Castro WH, Halm H, Jerosch J, Malms J, Steinbeck J, Blasius S (1996) Accuracy of pedicle screw placement in lumbar vertebrae. Spine 21:1320\u20131324","journal-title":"Spine"},{"key":"661_CR19","doi-asserted-by":"publisher","first-page":"452","DOI":"10.1097\/00007632-199702150-00020","volume":"22","author":"O Schwarzenbach","year":"1997","unstructured":"Schwarzenbach O, Berlemann U, Jost B, Visarius H, Arm E, Langlotz F, Nolte LP, Ozdoba C (1997) Accuracy of computer-assisted pedicle screw placement. An in vivo computed tomography analysis. Spine 22:452\u2013458","journal-title":"Spine"},{"key":"661_CR20","doi-asserted-by":"publisher","first-page":"895","DOI":"10.1007\/s00264-009-0792-3","volume":"33","author":"NF Tian","year":"2009","unstructured":"Tian NF, Xu HZ (2009) Image-guided pedicle screw insertion accuracy: a meta-analysis. Int Orthop 33:895\u2013903","journal-title":"Int Orthop"},{"key":"661_CR21","doi-asserted-by":"publisher","first-page":"E111","DOI":"10.1097\/01.brs.0000254048.79024.8b","volume":"32","author":"V Kosmopoulos","year":"2007","unstructured":"Kosmopoulos V, Schizas C (2007) Pedicle screw placement accuracy: a meta-analysis. Spine 32:E111\u2013E120","journal-title":"Spine"},{"key":"661_CR22","doi-asserted-by":"publisher","first-page":"370","DOI":"10.1007\/s00586-009-1258-4","volume":"19","author":"R Verma","year":"2010","unstructured":"Verma R, Krishan S, Haendlmayer K, Mohsen A (2010) Functional outcome of computer-assisted spinal pedicle screw placement: a systematic review and meta-analysis of 23 studies including 5,992 pedicle screws. Eur Spine J 19:370\u2013375","journal-title":"Eur Spine J"},{"issue":"664\u2013678","key":"661_CR23","first-page":"e3","volume":"126","author":"A Perdomo-Pantoja","year":"2019","unstructured":"Perdomo-Pantoja A, Ishida W, Zygourakis C, Holmes C, Iyer RR, Cottrill E, Theodore N, Witham TF, Lo SL (2019) Accuracy of current techniques for placement of pedicle screws in the spine: a comprehensive systematic review and meta-analysis of 51,161 screws. World Neurosurg. 126(664\u2013678):e3","journal-title":"World Neurosurg."},{"key":"661_CR24","first-page":"402","volume":"28","author":"SK Mirza","year":"2003","unstructured":"Mirza SK, Wiggins GC, C.t. Kuntz, J.E. York, C. Bellabarba, M.A. Knonodi, J.R. Chapman, and C.I. Shaffrey. (2003) Accuracy of thoracic vertebral body screw placement using standard fluoroscopy, fluoroscopic image guidance, and computed tomographic image guidance: a cadaver study. Spine 28:402\u2013413","journal-title":"Spine"},{"key":"661_CR25","doi-asserted-by":"publisher","first-page":"32","DOI":"10.1186\/s13037-017-0142-0","volume":"11","author":"J Riis","year":"2017","unstructured":"Riis J, Lehman RR, Perera RA, Quinn JR, Rinehart P, Tuten HR, Kuester V (2017) A retrospective comparison of intraoperative CT and fluoroscopy evaluating radiation exposure in posterior spinal fusions for scoliosis. Patient Saf Surg 11:32","journal-title":"Patient Saf Surg"},{"key":"661_CR26","doi-asserted-by":"publisher","first-page":"431","DOI":"10.1093\/rpd\/ncr149","volume":"148","author":"MS Park","year":"2012","unstructured":"Park MS, Lee KM, Lee B, Min E, Kim Y, Jeon S, Huh Y, Lee K (2012) Comparison of operator radiation exposure between C-arm and O-arm fluoroscopy for orthopaedic surgery. Radiat Prot Dosimetry 148:431\u2013438","journal-title":"Radiat Prot Dosimetry"},{"key":"661_CR27","doi-asserted-by":"publisher","first-page":"2078","DOI":"10.1001\/archinternmed.2009.427","volume":"169","author":"R Smith-Bindman","year":"2009","unstructured":"Smith-Bindman R, Lipson J, Marcus R, Kim KP, Mahesh M, Gould R, Berrington de Gonzalez A, Miglioretti DL (2009) Radiation dose associated with common computed tomography examinations and the associated lifetime attributable risk of cancer. Arch Intern Med 169:2078\u20132086","journal-title":"Arch Intern Med"},{"key":"661_CR28","doi-asserted-by":"publisher","first-page":"343","DOI":"10.1016\/j.spinee.2015.11.020","volume":"16","author":"D Mendelsohn","year":"2016","unstructured":"Mendelsohn D, Strelzow J, Dea N, Ford NL, Batke J, Pennington A, Yang K, Ailon T, Boyd M, Dvorak M, Kwon B, Paquette S, Fisher C, Street J (2016) Patient and surgeon radiation exposure during spinal instrumentation using intraoperative computed tomography-based navigation. Spine J 16:343\u2013354","journal-title":"Spine J"},{"key":"661_CR29","doi-asserted-by":"publisher","first-page":"2339","DOI":"10.1007\/s00586-017-5453-4","volume":"27","author":"S Rajasekaran","year":"2018","unstructured":"Rajasekaran S, Bhushan M, Aiyer S, Kanna R, Shetty AP (2018) Accuracy of pedicle screw insertion by AIRO((R)) intraoperative CT in complex spinal deformity assessed by a new classification based on technical complexity of screw insertion. Eur Spine J 27:2339\u20132347","journal-title":"Eur Spine J"}],"container-title":["Journal of Orthopaedics and Traumatology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s10195-022-00661-8.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s10195-022-00661-8\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s10195-022-00661-8.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,9,1]],"date-time":"2022-09-01T10:05:04Z","timestamp":1662026704000},"score":1,"resource":{"primary":{"URL":"https:\/\/jorthoptraumatol.springeropen.com\/articles\/10.1186\/s10195-022-00661-8"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,9,1]]},"references-count":29,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2022,12]]}},"alternative-id":["661"],"URL":"https:\/\/doi.org\/10.1186\/s10195-022-00661-8","relation":{},"ISSN":["1590-9921","1590-9999"],"issn-type":[{"value":"1590-9921","type":"print"},{"value":"1590-9999","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,9,1]]},"assertion":[{"value":"10 November 2021","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"3 August 2022","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"1 September 2022","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The study was approved by our local ethical committee with approval no. 276\/2020\/CE. All patients signed a written consent for surgery; owing to its retrospective nature, consent for the study was waived by our local ethical committee.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Not applicable.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare they have no competing financial interests with the current study.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"44"}}