{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,10]],"date-time":"2026-02-10T23:54:21Z","timestamp":1770767661231,"version":"3.50.0"},"reference-count":22,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2022,8,17]],"date-time":"2022-08-17T00:00:00Z","timestamp":1660694400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2022,8,17]],"date-time":"2022-08-17T00:00:00Z","timestamp":1660694400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["J Orthop Traumatol"],"published-print":{"date-parts":[[2022,12]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:sec>\n                <jats:title>Background<\/jats:title>\n                <jats:p>The aim of this study was to compare two techniques for the surgical treatment of diaphyseal fractures in the adult humerus: double-crossed retrograde elastic stable intramedullary nailing (DCR-ESIN) and limited-contact dynamic compression plate (LC-DCP).<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Methods<\/jats:title>\n                <jats:p>This was a retrospective study conducted at a single hospital. We included 122 patients with diaphyseal fractures of the humerus who had received DCR-ESIN or LC-DCP from January 2011 to January 2017. We compared union rates, union times, disabilities of the arm, shoulder, and hand (DASH) scores at the postoperative 1-year follow-up, and complications between the two groups.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Results<\/jats:title>\n                <jats:p>Plating management was performed in 63 patients, while DCR-ESIN was performed in 59 patients. The union rate was higher in the DCR-ESIN group than in the LC-DCP group (100% vs. 90.5%; <jats:italic>p<\/jats:italic>\u2009=\u20090.052). The union time was shorter in the DCR-ESIN group than in the LC-DCP group (12.0\u00a0weeks vs. 14.8\u00a0weeks; <jats:italic>p<\/jats:italic>\u2009&lt;\u20090.001). The intraoperative blood loss and operative time were less in the DCR-ESIN group than in the LC-DCP group (76.4\u00a0min vs. 129.5\u00a0min; <jats:italic>p<\/jats:italic>\u2009&lt;\u20090.001; 60.9\u00a0ml vs. 244.8\u00a0ml; <jats:italic>p<\/jats:italic>\u2009&lt;\u20090.001, respectively). The DCR-ESIN had superior results for the rate of overall complications (<jats:italic>p<\/jats:italic>\u2009=\u20090.006). At the 1-year follow-up, the DCR-ESIN group had better DASH scores than the LC-DCP group (<jats:italic>p<\/jats:italic>\u2009=\u20090.014).<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Conclusions<\/jats:title>\n                <jats:p>The DCR-ESIN technique, used to treat diaphyseal fractures of the humerus, has shorter operative times, less intra-operative blood loss, shorter union times, and better functional outcomes at 1-year follow-up than the LC-DCP technique. DCR-ESIN may be an alternative method for the surgical treatment of diaphyseal humeral fractures in adults.<\/jats:p>\n              <\/jats:sec>","DOI":"10.1186\/s10195-022-00662-7","type":"journal-article","created":{"date-parts":[[2022,8,17]],"date-time":"2022-08-17T16:08:19Z","timestamp":1660752499000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":5,"title":["Is double-crossed retrograde elastic stable intramedullary nailing an alternative method for the treatment of diaphyseal fractures in the adult humerus?"],"prefix":"10.1186","volume":"23","author":[{"given":"Hsuan-Hsiao","family":"Ma","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Chao-Ching","family":"Chiang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yu-Ping","family":"Su","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Kun-Hui","family":"Chen","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2022,8,17]]},"reference":[{"issue":"3","key":"662_CR1","doi-asserted-by":"publisher","first-page":"162","DOI":"10.1097\/00005131-200003000-00002","volume":"14","author":"JR Chapman","year":"2000","unstructured":"Chapman JR, Henley MB, Agel J, Benca PJ (2000) Randomized prospective study of humeral shaft fracture fixation: intramedullary nails versus plates. J Orthop Trauma 14(3):162\u2013166","journal-title":"J Orthop Trauma"},{"issue":"3","key":"662_CR2","doi-asserted-by":"publisher","first-page":"391","DOI":"10.1007\/s00264-006-0200-1","volume":"31","author":"M Changulani","year":"2007","unstructured":"Changulani M, Jain UK, Keswani T (2007) Comparison of the use of the humerus intramedullary nail and dynamic compression plate for the management of diaphyseal fractures of the humerus. A randomised controlled study. Int Orthop 31(3):391\u2013395. https:\/\/doi.org\/10.1007\/s00264-006-0200-1","journal-title":"Int Orthop"},{"issue":"3","key":"662_CR3","doi-asserted-by":"publisher","first-page":"133","DOI":"10.1007\/s11751-014-0204-0","volume":"9","author":"MG Wali","year":"2014","unstructured":"Wali MG, Baba AN, Latoo IA, Bhat NA, Baba OK, Sharma S (2014) Internal fixation of shaft humerus fractures by dynamic compression plate or interlocking intramedullary nail: a prospective, randomised study. Strategies Trauma Limb Reconstr 9(3):133\u2013140. https:\/\/doi.org\/10.1007\/s11751-014-0204-0","journal-title":"Strategies Trauma Limb Reconstr"},{"issue":"7","key":"662_CR4","doi-asserted-by":"publisher","first-page":"960","DOI":"10.2106\/00004623-198668070-00002","volume":"68","author":"RJ Brumback","year":"1986","unstructured":"Brumback RJ, Bosse MJ, Poka A, Burgess AR (1986) Intramedullary stabilization of humeral shaft fractures in patients with multiple trauma. J Bone Joint Surg Am 68(7):960\u2013970","journal-title":"J Bone Joint Surg Am"},{"key":"662_CR5","doi-asserted-by":"crossref","unstructured":"Hall RF Jr, Pankovich AM (1987) Ender nailing of acute fractures of the humerus. A study of closed fixation by intramedullary nails without reaming. J Bone Joint Surg Am 69(4):558\u201367","DOI":"10.2106\/00004623-198769040-00013"},{"issue":"2","key":"662_CR6","doi-asserted-by":"publisher","first-page":"117","DOI":"10.1007\/s10195-014-0290-2","volume":"15","author":"AK Singh","year":"2014","unstructured":"Singh AK, Narsaria N, Seth RR, Garg S (2014) Plate osteosynthesis of fractures of the shaft of the humerus: comparison of limited contact dynamic compression plates and locking compression plates. J Orthop Traumatol 15(2):117\u2013122. https:\/\/doi.org\/10.1007\/s10195-014-0290-2","journal-title":"J Orthop Traumatol"},{"issue":"Suppl 1","key":"662_CR7","doi-asserted-by":"publisher","first-page":"A20","DOI":"10.1016\/j.injury.2004.12.009","volume":"36","author":"JB Hunter","year":"2005","unstructured":"Hunter JB (2005) The principles of elastic stable intramedullary nailing in children. Injury 36(Suppl 1):A20\u2013A24. https:\/\/doi.org\/10.1016\/j.injury.2004.12.009","journal-title":"Injury"},{"issue":"2","key":"662_CR8","doi-asserted-by":"publisher","first-page":"385","DOI":"10.1007\/s00264-016-3210-7","volume":"41","author":"E Westrick","year":"2017","unstructured":"Westrick E, Hamilton B, Toogood P, Henley B, Firoozabadi R (2017) Humeral shaft fractures: results of operative and non-operative treatment. Int Orthop 41(2):385\u2013395. https:\/\/doi.org\/10.1007\/s00264-016-3210-7","journal-title":"Int Orthop"},{"issue":"11","key":"662_CR9","doi-asserted-by":"publisher","first-page":"1881","DOI":"10.1016\/j.jse.2017.07.001","volume":"26","author":"FE Harkin","year":"2017","unstructured":"Harkin FE, Large RJ (2017) Humeral shaft fractures: union outcomes in a large cohort. J Shoulder Elbow Surg 26(11):1881\u20131888. https:\/\/doi.org\/10.1016\/j.jse.2017.07.001","journal-title":"J Shoulder Elbow Surg"},{"issue":"6","key":"662_CR10","first-page":"626","volume":"116","author":"GJ Lloyd","year":"1977","unstructured":"Lloyd GJ, Wright TA (1977) 8. Self-compressing implants in the management of fractures. Can Med Assoc J 116(6):626\u20138","journal-title":"Can Med Assoc J"},{"key":"662_CR11","doi-asserted-by":"publisher","first-page":"139","DOI":"10.1186\/1746-6148-8-139","volume":"8","author":"M Hoerdemann","year":"2012","unstructured":"Hoerdemann M, Gedet P, Ferguson SJ, Sauter-Louis C, Nuss K (2012) In-vitro comparison of LC-DCP- and LCP-constructs in the femur of newborn calves\u2014a pilot study. BMC Vet Res 8:139. https:\/\/doi.org\/10.1186\/1746-6148-8-139","journal-title":"BMC Vet Res"},{"issue":"5","key":"662_CR12","doi-asserted-by":"publisher","first-page":"715","DOI":"10.1007\/s00264-009-0836-8","volume":"34","author":"Y Xiong","year":"2010","unstructured":"Xiong Y, Zhao YF, Xing SX et al (2010) Comparison of interface contact profiles of a new minimum contact locking compression plate and the limited contact dynamic compression plate. Int Orthop 34(5):715\u2013718. https:\/\/doi.org\/10.1007\/s00264-009-0836-8","journal-title":"Int Orthop"},{"key":"662_CR13","doi-asserted-by":"publisher","first-page":"5959","DOI":"10.1002\/14651858.CD005959.pub2","volume":"6","author":"H Kurup","year":"2011","unstructured":"Kurup H, Hossain M, Andrew JG (2011) Dynamic compression plating versus locked intramedullary nailing for humeral shaft fractures in adults. Cochrane Database Syst Rev 6:5959. https:\/\/doi.org\/10.1002\/14651858.CD005959.pub2","journal-title":"Cochrane Database Syst Rev"},{"issue":"9","key":"662_CR14","doi-asserted-by":"publisher","first-page":"683","DOI":"10.1016\/S0020-1383(00)00081-4","volume":"31","author":"CM Chen","year":"2000","unstructured":"Chen CM, Chiu FY, Lo WH (2000) Treatment of acute closed humeral shaft fractures with ender nails. Injury 31(9):683\u2013685","journal-title":"Injury"},{"issue":"6","key":"662_CR15","doi-asserted-by":"publisher","first-page":"947","DOI":"10.1097\/00005373-199712000-00014","volume":"43","author":"FY Chiu","year":"1997","unstructured":"Chiu FY, Chen CM, Lin CF, Lo WH, Huang YL, Chen TH (1997) Closed humeral shaft fractures: a prospective evaluation of surgical treatment. J Trauma 43(6):947\u2013951","journal-title":"J Trauma"},{"issue":"5","key":"662_CR16","doi-asserted-by":"publisher","first-page":"571","DOI":"10.1097\/00005373-198905000-00005","volume":"29","author":"WG DeLong Jr","year":"1989","unstructured":"DeLong WG Jr, Born CT, Marcelli E, Shaikh KA, Iannacone WM, Schwab CW (1989) Ender nail fixation in long bone fractures: experience in a level I trauma center. J Trauma 29(5):571\u2013576","journal-title":"J Trauma"},{"issue":"Suppl 2","key":"662_CR17","doi-asserted-by":"publisher","first-page":"105","DOI":"10.1007\/s12306-017-0509-5","volume":"101","author":"A Maresca","year":"2017","unstructured":"Maresca A, Sangiovanni P, Cerbasi S et al (2017) Why a surgically treated humeral shaft fracture became a nonunion: review of 11 years in two trauma centers. Musculoskelet Surg 101(Suppl 2):105\u2013112. https:\/\/doi.org\/10.1007\/s12306-017-0509-5","journal-title":"Musculoskelet Surg"},{"key":"662_CR18","doi-asserted-by":"crossref","unstructured":"Rodriguez-Merchan EC (1995) Compression plating versus Hackethal nailing in closed humeral shaft fractures failing nonoperative reduction. J Orthop Trauma 9(3):194\u2013197","DOI":"10.1097\/00005131-199506000-00003"},{"issue":"4","key":"662_CR19","doi-asserted-by":"publisher","first-page":"571","DOI":"10.1007\/s00264-009-0813-2","volume":"34","author":"K Singisetti","year":"2010","unstructured":"Singisetti K, Ambedkar M (2010) Nailing versus plating in humerus shaft fractures: a prospective comparative study. Int Orthop 34(4):571\u2013576. https:\/\/doi.org\/10.1007\/s00264-009-0813-2","journal-title":"Int Orthop"},{"issue":"11","key":"662_CR20","doi-asserted-by":"publisher","first-page":"e307","DOI":"10.1016\/j.jse.2015.07.012","volume":"24","author":"FM Claessen","year":"2015","unstructured":"Claessen FM, Peters RM, Verbeek DO, Helfet DL, Ring D (2015) Factors associated with radial nerve palsy after operative treatment of diaphyseal humeral shaft fractures. J Shoulder Elbow Surg 24(11):e307\u2013e311. https:\/\/doi.org\/10.1016\/j.jse.2015.07.012","journal-title":"J Shoulder Elbow Surg"},{"issue":"3","key":"662_CR21","doi-asserted-by":"publisher","first-page":"800","DOI":"10.1097\/TA.0b013e31816142cf","volume":"66","author":"JP Wang","year":"2009","unstructured":"Wang JP, Shen WJ, Chen WM, Huang CK, Shen YS, Chen TH (2009) Iatrogenic radial nerve palsy after operative management of humeral shaft fractures. J Trauma 66(3):800\u2013803. https:\/\/doi.org\/10.1097\/TA.0b013e31816142cf","journal-title":"J Trauma"},{"issue":"3","key":"662_CR22","doi-asserted-by":"publisher","first-page":"331","DOI":"10.1007\/s00590-013-1197-y","volume":"24","author":"X Wang","year":"2014","unstructured":"Wang X, Zhang P, Zhou Y, Zhu C (2014) Secondary radial nerve palsy after internal fixation of humeral shaft fractures. Eur J Orthop Surg Traumatol 24(3):331\u2013333. https:\/\/doi.org\/10.1007\/s00590-013-1197-y","journal-title":"Eur J Orthop Surg Traumatol"}],"container-title":["Journal of Orthopaedics and Traumatology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s10195-022-00662-7.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s10195-022-00662-7\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s10195-022-00662-7.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,8,17]],"date-time":"2022-08-17T16:08:23Z","timestamp":1660752503000},"score":1,"resource":{"primary":{"URL":"https:\/\/jorthoptraumatol.springeropen.com\/articles\/10.1186\/s10195-022-00662-7"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,8,17]]},"references-count":22,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2022,12]]}},"alternative-id":["662"],"URL":"https:\/\/doi.org\/10.1186\/s10195-022-00662-7","relation":{},"ISSN":["1590-9921","1590-9999"],"issn-type":[{"value":"1590-9921","type":"print"},{"value":"1590-9999","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,8,17]]},"assertion":[{"value":"14 March 2022","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"3 August 2022","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"17 August 2022","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The medical ethics committee of Taipei Veterans General Hospital approved the study. Written informed consent was obtained from all the participants. All procedures were performed in accordance with relevant guidelines. Taipei Veterans General Hospital approved the human protocol for this investigation, and each author certifies that all investigations were conducted in conformity with the ethical principles of research. The study was done at Taipei Veterans General Hospital, Taipei, Taiwan.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Not applicable.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"Each author certifies that he or she has no commercial associations (e.g., consultancies, stock ownership, equity interest, patent\/licensing arrangements, etc.) that might pose a conflict of interest in connection with the submitted article.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"40"}}