{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,18]],"date-time":"2026-11-18T02:08:49Z","timestamp":1794967729900,"version":"4.9.1"},"reference-count":28,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2023,6,29]],"date-time":"2023-06-29T00:00:00Z","timestamp":1687996800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2023,6,29]],"date-time":"2023-06-29T00:00:00Z","timestamp":1687996800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["J Orthop Traumatol"],"abstract":"<jats:title>Abstract<\/jats:title><jats:sec>\n                <jats:title>Background<\/jats:title>\n                <jats:p>Minimally invasive spine surgery is a field of active and intense research. Image-guided percutaneous pedicle screw (PPS) placement is a valid alternative to the standard free-hand technique, thanks to technological advancements that provide potential improvement in accuracy and safety. Herein, we describe the clinical results of a surgical technique exploiting integration of neuronavigation and intraoperative neurophysiological monitoring (IONM) for minimally invasive PPS.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Materials and Methods<\/jats:title>\n                <jats:p>An intraoperative-computed tomography (CT)-based neuronavigation system was combined with IONM in a three-step technique for PPS. Clinical and radiological data were collected to evaluate the safety and efficacy of the procedure. The accuracy of PPS placement was classified according to the Gertzbein\u2013Robbins scale.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Results<\/jats:title>\n                <jats:p>A total of 230 screws were placed in 49 patients. Only two screws were misplaced (0.8%); nevertheless, no clinical sign of radiculopathy was experienced by these patients. The majority of the screws (221, 96.1%) were classified as grade A according to Gertzbein\u2013Robbins scale, seven screws were classified as grade B, one screw was classified as grade D, and one last screw was classified as grade E.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Conclusions<\/jats:title>\n                <jats:p>The proposed three-step, navigated, percutaneous procedure offers a safe and accurate alternative to traditional techniques for lumbar and sacral pedicle screw placement.<\/jats:p>\n                <jats:p><jats:italic>Level of Evidence<\/jats:italic> Level 3.<\/jats:p>\n                <jats:p><jats:italic>Trial registration<\/jats:italic> Not applicable.<\/jats:p>\n              <\/jats:sec>","DOI":"10.1186\/s10195-023-00696-5","type":"journal-article","created":{"date-parts":[[2023,6,29]],"date-time":"2023-06-29T17:02:00Z","timestamp":1688058120000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":10,"title":["Navigated, percutaneous, three-step technique for lumbar and sacral screw placement: a novel, minimally invasive, and maximally safe strategy"],"prefix":"10.1186","volume":"24","author":[{"given":"Giuseppe","family":"La Rocca","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Edoardo","family":"Mazzucchi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Fabrizio","family":"Pignotti","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Luigi Aurelio","family":"Nasto","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Gianluca","family":"Galieri","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Pierluigi","family":"Rinaldi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Vincenzo","family":"De Santis","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Enrico","family":"Pola","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Giovanni","family":"Sabatino","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2023,6,29]]},"reference":[{"issue":"4","key":"696_CR1","doi-asserted-by":"publisher","first-page":"585","DOI":"10.1016\/j.nec.2017.06.002","volume":"28","author":"SE Adamczak","year":"2017","unstructured":"Adamczak SE, Bova FJ, Hoh DJ (2017) Intraoperative 3D computed tomography. Neurosurg Clin N Am 28(4):585\u2013594","journal-title":"Neurosurg Clin N Am"},{"issue":"5","key":"696_CR2","doi-asserted-by":"publisher","first-page":"990","DOI":"10.1007\/s00586-015-3853-x","volume":"24","author":"AA Aoude","year":"2015","unstructured":"Aoude AA, Fortin M, Figueiredo R, Jarzem P, Ouellet J, Weber MH (2015) Methods to determine pedicle screw placement accuracy in spine surgery: a systematic review. Eur Spine J 24(5):990\u20131004","journal-title":"Eur Spine J"},{"issue":"s2","key":"696_CR3","doi-asserted-by":"publisher","first-page":"S10","DOI":"10.14444\/8136","volume":"15","author":"DH Campbell","year":"2021","unstructured":"Campbell DH, McDonald D, Araghi K, Araghi T, Chutkan N, Araghi A (2021) The Clinical impact of image guidance and robotics in spinal surgery: a review of safety, accuracy, efficiency, and complication reduction. Int J Spine Surg 15(s2):S10\u2013S20","journal-title":"Int J Spine Surg"},{"issue":"2","key":"696_CR4","doi-asserted-by":"publisher","first-page":"232","DOI":"10.1111\/j.1469-7580.2006.00686.x","volume":"210","author":"R Chakraverty","year":"2007","unstructured":"Chakraverty R, Pynsent P, Isaacs K (2007) Which spinal levels are identified by palpation of the iliac crests and the posterior superior iliac spines? J Anatomy 210(2):232\u2013236","journal-title":"J Anatomy"},{"issue":"5","key":"696_CR5","doi-asserted-by":"publisher","first-page":"654","DOI":"10.3171\/2016.3.SPINE151139","volume":"25","author":"F Costa","year":"2016","unstructured":"Costa F, Tosi G, Attuati L, Cardia A, Ortolina A, Grimaldi M, Galbusera F, Fornari M (2016) Radiation exposure in spine surgery using an image-guided system based on intraoperative cone-beam computed tomography: analysis of 107 consecutive cases. SPI 25(5):654\u2013659","journal-title":"SPI"},{"issue":"3","key":"696_CR6","doi-asserted-by":"publisher","first-page":"268","DOI":"10.3171\/2017.1.SPINE16859","volume":"27","author":"M Czabanka","year":"2017","unstructured":"Czabanka M, Haemmerli J, Hecht N, Foehre B, Arden K, Liebig T, Woitzik J, Vajkoczy P (2017) Spinal navigation for posterior instrumentation of C1\u20132 instability using a mobile intraoperative CT scanner. J Neurosurg Spine 27(3):268\u2013275","journal-title":"J Neurosurg Spine"},{"issue":"4","key":"696_CR7","doi-asserted-by":"publisher","first-page":"E8","DOI":"10.3171\/2011.7.FOCUS11168","volume":"31","author":"OP Gautschi","year":"2011","unstructured":"Gautschi OP, Schatlo B, Schaller K, Tessitore E (2011) Clinically relevant complications related to pedicle screw placement in thoracolumbar surgery and their management: a literature review of 35,630 pedicle screws. FOC 31(4):E8","journal-title":"FOC"},{"issue":"1","key":"696_CR8","doi-asserted-by":"publisher","first-page":"11","DOI":"10.1097\/00007632-199001000-00004","volume":"15","author":"SD Gertzbein","year":"1990","unstructured":"Gertzbein SD, Robbins SE (1990) Accuracy of pedicular screw placement in vivo. Spine 15(1):11\u201314","journal-title":"Spine"},{"issue":"3","key":"696_CR9","doi-asserted-by":"publisher","first-page":"661","DOI":"10.1007\/s00586-012-2499-1","volume":"22","author":"X Hu","year":"2013","unstructured":"Hu X, Ohnmeiss DD, Lieberman IH (2013) Robotic-assisted pedicle screw placement: lessons learned from the first 102 patients. Eur Spine J 22(3):661\u2013666","journal-title":"Eur Spine J"},{"issue":"12","key":"696_CR10","doi-asserted-by":"publisher","first-page":"3720","DOI":"10.1007\/s00586-021-06981-3","volume":"30","author":"S Ille","year":"2021","unstructured":"Ille S, Baumgart L, Obermueller T, Meyer B, Krieg SM (2021) Clinical efficiency of operating room-based sliding gantry CT as compared to mobile cone-beam CT-based navigated pedicle screw placement in 853 patients and 6733 screws. Eur Spine J 30(12):3720\u20133730","journal-title":"Eur Spine J"},{"key":"696_CR11","doi-asserted-by":"publisher","first-page":"5048659","DOI":"10.1155\/2016\/5048659","volume":"2016","author":"J-S Kim","year":"2016","unstructured":"Kim J-S, H\u00e4rtl R, Mayer HM (2016) Minimally invasive spinal surgery. Biomed Res Int 2016:5048659","journal-title":"Biomed Res Int"},{"issue":"3","key":"696_CR12","doi-asserted-by":"publisher","first-page":"333","DOI":"10.1097\/01.BRS.0000109983.12113.9B","volume":"29","author":"YJ Kim","year":"2004","unstructured":"Kim YJ, Lenke LG, Bridwell KH, Cho YS, Riew KD (2004) Free hand pedicle screw placement in the thoracic spine: is it safe? Spine 29(3):333\u2013342","journal-title":"Spine"},{"issue":"12","key":"696_CR13","doi-asserted-by":"publisher","first-page":"2273","DOI":"10.1007\/s11548-016-1448-6","volume":"11","author":"H Liu","year":"2016","unstructured":"Liu H, Chen W, Wang Z, Lin J, Meng B, Yang H (2016) Comparison of the accuracy between robot-assisted and conventional freehand pedicle screw placement: a systematic review and meta-analysis. Int J CARS 11(12):2273\u20132281","journal-title":"Int J CARS"},{"issue":"1","key":"696_CR14","doi-asserted-by":"publisher","first-page":"165","DOI":"10.1016\/j.spinee.2013.03.029","volume":"14","author":"A Manbachi","year":"2014","unstructured":"Manbachi A, Cobbold RSC, Ginsberg HJ (2014) Guided pedicle screw insertion: techniques and training. Spine J 14(1):165\u2013179","journal-title":"Spine J"},{"issue":"3","key":"696_CR15","doi-asserted-by":"publisher","first-page":"343","DOI":"10.1016\/j.spinee.2015.11.020","volume":"16","author":"D Mendelsohn","year":"2016","unstructured":"Mendelsohn D, Strelzow J, Dea N et\u00a0al (2016) Patient and surgeon radiation exposure during spinal instrumentation using intraoperative computed tomography-based navigation. Spine J 16(3):343\u2013354","journal-title":"Spine J"},{"issue":"1","key":"696_CR16","doi-asserted-by":"publisher","first-page":"83","DOI":"10.1055\/s-0036-1583942","volume":"7","author":"A Nooh","year":"2017","unstructured":"Nooh A, Lubov J, Aoude A, Aldebeyan S, Jarzem P, Ouellet J, Weber MH (2017) Differences between manufacturers of computed tomography-based computer-assisted surgery systems do exist: a systematic literature review. Global Spine J 7(1):83\u201394","journal-title":"Global Spine J"},{"key":"696_CR17","doi-asserted-by":"publisher","first-page":"43","DOI":"10.1016\/j.wneu.2020.06.043","volume":"142","author":"PD Patel","year":"2020","unstructured":"Patel PD, Canseco JA, Houlihan N, Gabay A, Grasso G, Vaccaro AR (2020) Overview of minimally invasive spine surgery. World Neurosurg 142:43\u201356","journal-title":"World Neurosurg"},{"issue":"2","key":"696_CR18","doi-asserted-by":"publisher","first-page":"112","DOI":"10.5312\/wjo.v5.i2.112","volume":"5","author":"V Puvanesarajah","year":"2014","unstructured":"Puvanesarajah V (2014) Techniques and accuracy of thoracolumbar pedicle screw placement. WJO 5(2):112","journal-title":"WJO"},{"key":"696_CR19","doi-asserted-by":"publisher","first-page":"218","DOI":"10.1016\/j.jocn.2017.11.012","volume":"48","author":"J Quillo-Olvera","year":"2018","unstructured":"Quillo-Olvera J, Lin G-X, Suen T-K, Jo H-J, Kim J-S (2018) Anterior transcorporeal tunnel approach for cervical myelopathy guided by CT-based intraoperative spinal navigation: technical note. J Clin Neurosci 48:218\u2013223","journal-title":"J Clin Neurosci"},{"issue":"5","key":"696_CR20","doi-asserted-by":"publisher","first-page":"1003","DOI":"10.1177\/21925682211018472","volume":"12","author":"RP Reddy","year":"2022","unstructured":"Reddy RP, Chang R, Coutinho DV, Meinert JW, Anetakis KM, Crammond DJ, Balzer JR, Shaw JD, Lee JY, Thirumala PD (2022) Triggered electromyography is a useful intraoperative adjunct to predict postoperative neurological deficit following lumbar pedicle screw instrumentation. Global Spine Journal 12(5):1003\u20131011","journal-title":"Global Spine Journal"},{"issue":"4","key":"696_CR21","doi-asserted-by":"publisher","first-page":"397","DOI":"10.3171\/2018.1.SPINE17927","volume":"29","author":"P Scarone","year":"2018","unstructured":"Scarone P, Vincenzo G, Distefano D, Del Grande F, Cianfoni A, Presilla S, Reinert M (2018) Use of the Airo mobile intraoperative CT system versus the O-arm for transpedicular screw fixation in the thoracic and lumbar spine: a retrospective cohort study of 263 patients. J Neurosurg Spine 29(4):397\u2013406","journal-title":"J Neurosurg Spine"},{"issue":"1","key":"696_CR22","doi-asserted-by":"publisher","first-page":"102","DOI":"10.3171\/2014.4.SPINE14324","volume":"21","author":"A Sharan","year":"2014","unstructured":"Sharan A, Groff MW, Dailey AT et\u00a0al. (2014) Guideline update for the performance of fusion procedures for degenerative disease of the lumbar spine. Part 15: Electrophysiological monitoring and lumbar fusion. J Neurosurg Spine 21(1):102\u2013105","journal-title":"J Neurosurg Spine"},{"key":"696_CR23","doi-asserted-by":"publisher","first-page":"433","DOI":"10.1016\/j.wneu.2018.05.159","volume":"116","author":"VE Staartjes","year":"2018","unstructured":"Staartjes VE, Klukowska AM, Schr\u00f6der ML (2018) Pedicle screw revision in robot-guided, navigated, and freehand thoracolumbar instrumentation: a systematic review and meta-analysis. World Neurosurg 116:433-443.e8","journal-title":"World Neurosurg"},{"issue":"1","key":"696_CR24","doi-asserted-by":"publisher","first-page":"25","DOI":"10.1007\/s00586-009-1091-9","volume":"19","author":"T Tjardes","year":"2010","unstructured":"Tjardes T, Shafizadeh S, Rixen D, Paffrath T, Bouillon B, Steinhausen ES, Baethis H (2010) Image-guided spine surgery: state of the art and future directions. Eur Spine J 19(1):25\u201345","journal-title":"Eur Spine J"},{"issue":"1","key":"696_CR25","doi-asserted-by":"publisher","first-page":"49","DOI":"10.1186\/s10195-022-00669-0","volume":"23","author":"S Luengo-Matos","year":"2022","unstructured":"Luengo-Matos S, S\u00e0nchez-G\u00f2mez LM, Hijas-G\u00f2mez AI, Garc\u00eca-Carpintero EE, Ballesteros- Mass\u00f2 R, Polo-deSantos M (2022) Efficacy and safety of robotic spine surgery: systematic review and meta-analysis. J Orthop Traumatol 23(1):49","journal-title":"J Orthop Traumatol"},{"issue":"1","key":"696_CR26","doi-asserted-by":"publisher","first-page":"44","DOI":"10.1186\/s10195-022-00661-8","volume":"23","author":"G La Rocca","year":"2022","unstructured":"La Rocca G, Mazzucchi E, Pignotti F, Nasto LA, Galieri G, Olivi A, De Santis V, Rinaldi P, Pola E, Sabatino G (2022) Intraoperative CT-guided navigation versus fluoroscopy for percutaneous pedicle screw placement in 192 patients: a comparative analysis. J Orthop Traumatol 23(1):44","journal-title":"J Orthop Traumatol"},{"issue":"13","key":"696_CR27","doi-asserted-by":"publisher","first-page":"1004","DOI":"10.1097\/BRS.0000000000000351","volume":"39","author":"J Villard","year":"2014","unstructured":"Villard J, Ryang Y-M, Demetriades AK, Reinke A, Behr M, Preuss A, Meyer B, Ringel F (2014) Radiation exposure to the surgeon and the patient during posterior lumbar spinal instrumentation: a prospective randomized comparison of navigated versus non-navigated freehand techniques. Spine 39(13):1004\u20131009","journal-title":"Spine"},{"issue":"2","key":"696_CR28","doi-asserted-by":"publisher","first-page":"351","DOI":"10.1007\/s00264-018-4005-9","volume":"43","author":"Y Wang","year":"2019","unstructured":"Wang Y, Chen K, Chen H, Zhang K, Lu J, Mao H, Yang H (2019) Comparison between free-hand and O-arm-based navigated posterior lumbar interbody fusion in elderly cohorts with three-level lumbar degenerative disease. Int Orthop 43(2):351\u2013357","journal-title":"Int Orthop"}],"container-title":["Journal of Orthopaedics and Traumatology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s10195-023-00696-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s10195-023-00696-5\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s10195-023-00696-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,6,29]],"date-time":"2023-06-29T17:02:02Z","timestamp":1688058122000},"score":1,"resource":{"primary":{"URL":"https:\/\/jorthoptraumatol.springeropen.com\/articles\/10.1186\/s10195-023-00696-5"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,6,29]]},"references-count":28,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2023,12]]}},"alternative-id":["696"],"URL":"https:\/\/doi.org\/10.1186\/s10195-023-00696-5","relation":{},"ISSN":["1590-9999"],"issn-type":[{"value":"1590-9999","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,6,29]]},"assertion":[{"value":"9 October 2022","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"2 April 2023","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"29 June 2023","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The study was approved by our local ethical committee (Comitato Etico Aziendale ATS Sardegna) with approval no. N.276\/120\/CE. All patients signed a written consent for surgery, due to its retrospective nature consent for the study was waived by our local ethical committee.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Not applicable.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent of publication"}},{"value":"The authors declare they have no competing financial interests with the current study.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"32"}}