{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,27]],"date-time":"2026-10-27T10:05:34Z","timestamp":1793095534669,"version":"4.5.0"},"reference-count":56,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2023,8,11]],"date-time":"2023-08-11T00:00:00Z","timestamp":1691712000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2023,8,11]],"date-time":"2023-08-11T00:00:00Z","timestamp":1691712000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["J Orthop Traumatol"],"abstract":"<jats:title>Abstract<\/jats:title><jats:sec>\n                <jats:title>Background<\/jats:title>\n                <jats:p>Carbon-fibre (CF) plates are increasingly used for fracture fixation. This systematic review evaluated complications associated with CF plate fixation. It also compared outcomes of patients treated with CF plates versus metal plates, aiming to determine if CF plates offered comparable results. The study hypothesized that CF plates display similar complication rates and clinical outcomes as metal plates for fracture fixation.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Methods<\/jats:title>\n                <jats:p>The study adhered to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines. The following databases were searched from database inception until June 2023: PubMed, MEDLINE, Embase, Web of Science, Cochrane Library, Emcare, Academic Search Premier and Google Scholar. Studies reporting on clinical and radiological outcomes of patients treated with CF plates for traumatic fractures and (impending) pathological fractures were included. Study quality was assessed, and complications were documented as number and percentage per anatomic region.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Results<\/jats:title>\n                <jats:p>A total of 27 studies of moderate to very low quality of evidence were included. Of these, 22 studies (800 patients, median follow-up 12\u00a0months) focused on traumatic fractures, and 5 studies (102 patients, median follow-up 12\u00a0months) on (impending) pathological fractures. A total of 11 studies (497 patients, median follow-up 16\u00a0months) compared CF plates with metal plates. Regarding traumatic fractures, the following complications were mostly reported: soft tissue complications (52 out of 391; 13%) for the humerus, structural complications (6 out of 291; 2%) for the distal radius, nonunion and structural complication (1 out of 34; 3%) for the femur, and infection (4 out of 104; 4%) for the ankle. For (impending) pathological fractures, the most frequently reported complications were infections (2 out of 14; 14%) for the humerus and structural complication (6 out of 86; 7%) for the femur\/tibia. Comparative studies reported mixed results, although the majority (7 out of 11; 64%) reported no significant differences in clinical or radiological outcomes between patients treated with CF or metal plates.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Conclusion<\/jats:title>\n                <jats:p>This systematic review did not reveal a concerning number of complications related to CF plate fixation. Comparative studies showed no significant differences between CF plates and metal plates for traumatic fracture fixation. Therefore, CF plates appear to be a viable alternative to metal plates. However, high-quality randomized controlled trials (RCTs) with long-term follow-up are strongly recommended to provide additional evidence supporting the use of CF plates.<\/jats:p>\n                <jats:p><jats:italic>Level of evidence<\/jats:italic>:  III, systematic review.<\/jats:p>\n              <\/jats:sec>","DOI":"10.1186\/s10195-023-00724-4","type":"journal-article","created":{"date-parts":[[2023,8,11]],"date-time":"2023-08-11T13:02:03Z","timestamp":1691758923000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":13,"title":["Carbon-fibre plates for traumatic and (impending) pathological fracture fixation: Where do we stand? A systematic review"],"prefix":"10.1186","volume":"24","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-9492-4110","authenticated-orcid":false,"given":"Zeger","family":"Rijs","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Amber","family":"Weekhout","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Stef","family":"Daniel","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jan W.","family":"Schoones","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Olivier Q.","family":"Groot","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Santiago A.","family":"Lozano-Calderon","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Michiel A. J.","family":"van de Sande","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2023,8,11]]},"reference":[{"key":"724_CR1","doi-asserted-by":"publisher","first-page":"3036","DOI":"10.1200\/JCO.2014.59.5256","volume":"33","author":"N Gaspar","year":"2015","unstructured":"Gaspar N, Hawkins DS, Dirksen U et al (2015) Ewing sarcoma: current management and future approaches through collaboration. J Clin Oncol 33:3036\u20133046","journal-title":"J Clin Oncol"},{"key":"724_CR2","doi-asserted-by":"publisher","first-page":"279","DOI":"10.1106\/BKLQ-E2YG-D2LA-RG3R","volume":"15","author":"KP Baidya","year":"2001","unstructured":"Baidya KP, Ramakrishna S, Rahman M et al (2001) Quantitative radiographic analysis of fiber reinforced polymer composites. J Biomater Appl 15:279\u2013289","journal-title":"J Biomater Appl"},{"key":"724_CR3","doi-asserted-by":"publisher","first-page":"712","DOI":"10.1016\/j.medengphy.2012.07.016","volume":"35","author":"EM Feerick","year":"2013","unstructured":"Feerick EM, Kennedy J, Mullett H et al (2013) Investigation of metallic and carbon fibre PEEK fracture fixation devices for three-part proximal humeral fractures. Med Eng Phys 35:712\u2013722","journal-title":"Med Eng Phys"},{"key":"724_CR4","doi-asserted-by":"publisher","first-page":"825","DOI":"10.3928\/01477447-20141124-05","volume":"37","author":"DJ Hak","year":"2014","unstructured":"Hak DJ, Mauffrey C, Seligson D et al (2014) Use of carbon-fiber-reinforced composite implants in orthopedic surgery. Orthopedics 37:825\u2013830","journal-title":"Orthopedics"},{"key":"724_CR5","doi-asserted-by":"publisher","first-page":"61","DOI":"10.1016\/j.wneu.2021.05.100","volume":"152","author":"A Takayanagi","year":"2021","unstructured":"Takayanagi A, Siddiqi I, Ghanchi H et al (2021) Radiolucent carbon fiber-reinforced implants for treatment of spinal tumors-clinical, radiographic, and dosimetric considerations. World Neurosurg 152:61\u201370","journal-title":"World Neurosurg"},{"key":"724_CR6","doi-asserted-by":"publisher","first-page":"323","DOI":"10.21037\/jss.2017.06.20","volume":"3","author":"G Tedesco","year":"2017","unstructured":"Tedesco G, Gasbarrini A, Bandiera S et al (2017) Composite PEEK\/Carbon fiber implants can increase the effectiveness of radiotherapy in the management of spine tumors. J Spine Surg 3:323\u2013329","journal-title":"J Spine Surg"},{"key":"724_CR7","doi-asserted-by":"publisher","first-page":"256","DOI":"10.1016\/j.prro.2023.01.009","volume":"13","author":"N Depauw","year":"2023","unstructured":"Depauw N, Pursley J, Lozano-Calderon SA et al (2023) Evaluation of carbon fiber and titanium surgical implants for proton and photon therapy. Pract Radiat Oncol 13:256\u2013262","journal-title":"Pract Radiat Oncol"},{"key":"724_CR8","doi-asserted-by":"publisher","first-page":"877","DOI":"10.1016\/j.otsr.2018.05.002","volume":"104","author":"R Mugnai","year":"2018","unstructured":"Mugnai R, Tarallo L, Capra F et al (2018) Biomechanical comparison between stainless steel, titanium and carbon-fiber reinforced polyetheretherketone volar locking plates for distal radius fractures. Orthop Traumatol Surg Res 104:877\u2013882","journal-title":"Orthop Traumatol Surg Res"},{"key":"724_CR9","doi-asserted-by":"publisher","DOI":"10.1115\/1.4027669","volume":"136","author":"ZS Bagheri","year":"2014","unstructured":"Bagheri ZS, Tavakkoli Avval P, Bougherara H et al (2014) Biomechanical analysis of a new carbon fiber\/flax\/epoxy bone fracture plate shows less stress shielding compared to a standard clinical metal plate. J Biomech Eng 136:091002","journal-title":"J Biomech Eng"},{"key":"724_CR10","doi-asserted-by":"publisher","first-page":"1293","DOI":"10.1007\/s00590-020-02701-7","volume":"30","author":"L Tarallo","year":"2020","unstructured":"Tarallo L, Giorgini A, Novi M et al (2020) Volar PEEK plate for distal radius fracture: analysis of adverse events. Eur J Orthop Surg Traumatol 30:1293\u20131298","journal-title":"Eur J Orthop Surg Traumatol"},{"key":"724_CR11","doi-asserted-by":"publisher","first-page":"2387","DOI":"10.1007\/s00068-021-01778-x","volume":"48","author":"GD Chloros","year":"2022","unstructured":"Chloros GD, Prodromidis AD, Wilson J et al (2022) Fracture fixation in extremity trauma with carbon fiber-reinforced polyetheretherketone (CFR-PEEK) plates: evidence today. Eur J Trauma Emerg Surg 48:2387\u20132406","journal-title":"Eur J Trauma Emerg Surg"},{"key":"724_CR12","doi-asserted-by":"publisher","first-page":"28362","DOI":"10.52965\/001c.28362","volume":"13","author":"M Saracco","year":"2021","unstructured":"Saracco M, Fulchignoni C, Velluto C et al (2021) Safety and reliability of carbon-peek plate for the treatment of distal radius fractures: a review of the literature. Orthop Rev 13:28362","journal-title":"Orthop Rev"},{"key":"724_CR13","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcot.2021.101674","volume":"23","author":"K Theivendran","year":"2021","unstructured":"Theivendran K, Arshad F, Hanif UK et al (2021) Carbon fibre reinforced PEEK versus traditional metallic implants for orthopaedic trauma surgery: a systematic review. J Clin Orthop Trauma 23:101674","journal-title":"J Clin Orthop Trauma"},{"key":"724_CR14","doi-asserted-by":"publisher","first-page":"398","DOI":"10.1016\/j.jmbbm.2012.12.013","volume":"20","author":"ZS Bagheri","year":"2013","unstructured":"Bagheri ZS, El Sawi I, Schemitsch EH et al (2013) Biomechanical properties of an advanced new carbon\/flax\/epoxy composite material for bone plate applications. J Mech Behav Biomed Mater 20:398\u2013406","journal-title":"J Mech Behav Biomed Mater"},{"key":"724_CR15","doi-asserted-by":"publisher","first-page":"548","DOI":"10.1177\/1071100715625291","volume":"37","author":"WK Wilson","year":"2016","unstructured":"Wilson WK, Morris RP, Ward AJ et al (2016) Torsional failure of carbon fiber composite plates versus stainless steel plates for comminuted distal fibula fractures. Foot Ankle Int 37:548\u2013553","journal-title":"Foot Ankle Int"},{"issue":"Suppl 1","key":"724_CR16","doi-asserted-by":"publisher","first-page":"S1","DOI":"10.1007\/s12306-015-0371-2","volume":"99","author":"R Rotini","year":"2015","unstructured":"Rotini R, Cavaciocchi M, Fabbri D et al (2015) Proximal humeral fracture fixation: multicenter study with carbon fiber peek plate. Musculoskelet Surg 99(Suppl 1):S1-8","journal-title":"Musculoskelet Surg"},{"issue":"e20","key":"724_CR17","first-page":"00041","volume":"10","author":"WA Goudriaan","year":"2020","unstructured":"Goudriaan WA, Tordoir RL, Broekhuis D et al (2020) Early failure of a carbon-fiber-reinforced polyetheretherketone distal femur plate: a case report. JBJS Case Connect. 10(e20):00041","journal-title":"JBJS Case Connect."},{"key":"724_CR18","doi-asserted-by":"publisher","DOI":"10.1136\/bmj.n71","volume":"372","author":"MJ Page","year":"2021","unstructured":"Page MJ, McKenzie JE, Bossuyt PM et al (2021) The PRISMA 2020 statement: an updated guideline for reporting systematic reviews. BMJ 372:n71","journal-title":"BMJ"},{"key":"724_CR19","unstructured":"Institute. TJB. JBI Critical Appraisal Checklist for Case Reports. 2017."},{"key":"724_CR20","doi-asserted-by":"publisher","DOI":"10.1136\/bmj.i4919","volume":"355","author":"JA Sterne","year":"2016","unstructured":"Sterne JA, Hern\u00e1n MA, Reeves BC et al (2016) ROBINS-I: a tool for assessing risk of bias in non-randomised studies of interventions. BMJ 355:i4919","journal-title":"BMJ"},{"key":"724_CR21","doi-asserted-by":"publisher","DOI":"10.1136\/bmj.l4898","volume":"366","author":"JAC Sterne","year":"2019","unstructured":"Sterne JAC, Savovi\u0107 J, Page MJ et al (2019) RoB 2: a revised tool for assessing risk of bias in randomised trials. BMJ 366:l4898","journal-title":"BMJ"},{"key":"724_CR22","doi-asserted-by":"publisher","first-page":"924","DOI":"10.1136\/bmj.39489.470347.AD","volume":"336","author":"GH Guyatt","year":"2008","unstructured":"Guyatt GH, Oxman AD, Vist GE et al (2008) GRADE: an emerging consensus on rating quality of evidence and strength of recommendations. BMJ 336:924\u2013926","journal-title":"BMJ"},{"key":"724_CR23","unstructured":"Doyle DJ, Hendrix JM, Garmon EH. American Society of Anesthesiologists Classification. StatPearls. Treasure Island (FL) ineligible companies. Disclosure: Joseph Maxwell Hendrix declares no relevant financial relationships with ineligible companies. Disclosure: Emily Garmon declares no relevant financial relationships with ineligible companies.: StatPearls Publishing. Copyright \u00a9 2023, StatPearls Publishing LLC.; 2023."},{"key":"724_CR24","doi-asserted-by":"publisher","first-page":"177","DOI":"10.1080\/17453670610045902","volume":"77","author":"M Sundfeldt","year":"2006","unstructured":"Sundfeldt M, Carlsson LV, Johansson CB et al (2006) Aseptic loosening, not only a question of wear: a review of different theories. Acta Orthop 77:177\u2013197","journal-title":"Acta Orthop"},{"key":"724_CR25","doi-asserted-by":"publisher","DOI":"10.1016\/j.jmbbm.2021.104608","volume":"121","author":"E Liverani","year":"2021","unstructured":"Liverani E, Rogati G, Pagani S et al (2021) Mechanical interaction between additive-manufactured metal lattice structures and bone in compression: implications for stress shielding of orthopaedic implants. J Mech Behav Biomed Mater 121:104608","journal-title":"J Mech Behav Biomed Mater"},{"key":"724_CR26","doi-asserted-by":"publisher","first-page":"351","DOI":"10.1007\/s00590-016-1891-7","volume":"27","author":"JC Katthagen","year":"2017","unstructured":"Katthagen JC, Ellwein A, Lutz O et al (2017) Outcomes of proximal humeral fracture fixation with locked CFR-PEEK plating. Eur J Orthop Surg Traumatol 27:351\u2013358","journal-title":"Eur J Orthop Surg Traumatol"},{"key":"724_CR27","doi-asserted-by":"publisher","first-page":"49","DOI":"10.1007\/s12306-018-0562-8","volume":"102","author":"A Padolino","year":"2018","unstructured":"Padolino A, Porcellini G, Guollo B et al (2018) Comparison of CFR-PEEK and conventional titanium locking plates for proximal humeral fractures: a retrospective controlled study of patient outcomes. Musculoskelet Surg 102:49\u201356","journal-title":"Musculoskelet Surg"},{"key":"724_CR28","doi-asserted-by":"publisher","first-page":"1282","DOI":"10.1016\/j.jse.2014.12.028","volume":"24","author":"B Schliemann","year":"2015","unstructured":"Schliemann B, Hartensuer R, Koch T et al (2015) Treatment of proximal humerus fractures with a CFR-PEEK plate: 2-year results of a prospective study and comparison to fixation with a conventional locking plate. J Shoulder Elbow Surg 24:1282\u20131288","journal-title":"J Shoulder Elbow Surg"},{"key":"724_CR29","first-page":"757","volume":"116","author":"P Ziegler","year":"2019","unstructured":"Ziegler P, Maier S, St\u00f6ckle U et al (2019) The treatment of proximal humerus fracture using internal fixation with fixed-angle plates. Dtsch Arztebl Int 116:757\u2013763","journal-title":"Dtsch Arztebl Int"},{"key":"724_CR30","doi-asserted-by":"publisher","first-page":"1307","DOI":"10.1007\/s00590-022-03298-9","volume":"33","author":"RO Dey Hazra","year":"2022","unstructured":"Dey Hazra RO, Szewczyk K, Ellwein A et al (2022) Minimum 2-year results of the second-generation CFR-PEEK locking plate on the proximal humeral fracture. Eur J Orthop Surg Traumatol 33:1307\u20131314","journal-title":"Eur J Orthop Surg Traumatol"},{"key":"724_CR31","doi-asserted-by":"publisher","first-page":"63","DOI":"10.1186\/s12891-023-06176-5","volume":"24","author":"M Kimmeyer","year":"2023","unstructured":"Kimmeyer M, Schmalzl J, Rentschler V et al (2023) Functional results and unfavorable events after treatment of proximal humerus fractures using a new locking plate system. BMC Musculoskelet Disord 24:63","journal-title":"BMC Musculoskelet Disord"},{"key":"724_CR32","doi-asserted-by":"publisher","first-page":"30","DOI":"10.1186\/s13037-019-0210-8","volume":"13","author":"F Allemann","year":"2019","unstructured":"Allemann F, Halvachizadeh S, Rauer T et al (2019) Clinical outcomes after carbon-plate osteosynthesis in patients with distal radius fractures. Patient Saf Surg 13:30","journal-title":"Patient Saf Surg"},{"key":"724_CR33","doi-asserted-by":"publisher","first-page":"139","DOI":"10.1007\/s00113-015-0088-6","volume":"120","author":"P Behrendt","year":"2017","unstructured":"Behrendt P, Kruse E, Kl\u00fcter T et al (2017) Winkelstabile karbonverst\u00e4rkte Polymerkompositplatte zur Versorgung einer distalen Radiusfraktur. Unfallchirurg 120:139\u2013146","journal-title":"Unfallchirurg"},{"issue":"Suppl 3","key":"724_CR34","doi-asserted-by":"publisher","first-page":"S34","DOI":"10.1016\/S0020-1383(17)30655-1","volume":"48","author":"B Di Maggio","year":"2017","unstructured":"Di Maggio B, Sessa P, Mantelli P et al (2017) PEEK radiolucent plate for distal radius fractures: multicentre clinical results at 12\u00a0months follow up. Injury 48(Suppl 3):S34-s38","journal-title":"Injury"},{"key":"724_CR35","doi-asserted-by":"publisher","first-page":"185","DOI":"10.36149\/0390-5276-224","volume":"36","author":"M Paracuollo","year":"2022","unstructured":"Paracuollo M, Coscione AV, Coppola A et al (2022) Clinical and radiographic outcomes of distal radius fracture treatment with Carbon-fiber-reinforced- polymer volar plates (CFRPEEK): analysis of 40 cases. Lo Scalpello J 36:185\u2013190","journal-title":"Lo Scalpello J"},{"issue":"Suppl 3","key":"724_CR36","doi-asserted-by":"publisher","first-page":"S24","DOI":"10.1016\/S0020-1383(17)30653-8","volume":"48","author":"D Perugia","year":"2017","unstructured":"Perugia D, Guzzini M, Mazza D et al (2017) Comparison between carbon-peek volar locking plates and titanium volar locking plates in the treatment of distal radius fractures. Injury 48(Suppl 3):S24-s29","journal-title":"Injury"},{"key":"724_CR37","doi-asserted-by":"publisher","first-page":"521","DOI":"10.52628\/87.3.18","volume":"87","author":"J Berger-Groch","year":"2021","unstructured":"Berger-Groch J, Stodtmeister AC, Petersen JP et al (2021) Palmar plating of distal radius fractures\u202f: 3-year follow-up with titanium and PEEK plates give similar outcomes. Acta Orthop Belg 87:521\u2013527","journal-title":"Acta Orthop Belg"},{"key":"724_CR38","first-page":"61","volume":"90","author":"M Guzzini","year":"2018","unstructured":"Guzzini M, Lupariello D, Lanzetti RM et al (2018) Preliminary experience with triangular CarboFix \u201cPiccolo\u201d distal radius plate in wrist fractures. Clin Radiolog Results Acta Biomed 90:61\u201366","journal-title":"Clin Radiolog Results Acta Biomed"},{"key":"724_CR39","doi-asserted-by":"publisher","first-page":"596","DOI":"10.1016\/j.injury.2003.10.014","volume":"35","author":"D Baker","year":"2004","unstructured":"Baker D, Kadambande SS, Alderman PM (2004) Carbon fibre plates in the treatment of femoral periprosthetic fractures. Injury 35:596\u2013598","journal-title":"Injury"},{"key":"724_CR40","doi-asserted-by":"publisher","first-page":"1103","DOI":"10.1007\/s00590-020-02681-8","volume":"30","author":"SE Byun","year":"2020","unstructured":"Byun SE, Vintimilla DR, Bedeir YH et al (2020) Evaluation of callus formation in distal femur fractures after carbon fiber composite versus stainless steel plate fixation. Eur J Orthop Surg Traumatol 30:1103\u20131107","journal-title":"Eur J Orthop Surg Traumatol"},{"key":"724_CR41","doi-asserted-by":"publisher","DOI":"10.1016\/j.tcr.2021.100493","volume":"34","author":"MB Mellon","year":"2021","unstructured":"Mellon MB (2021) Late recognition of an early catastrophic failure of a carbon fiber reinforced distal femoral plate: a case report. Trauma Case Rep 34:100493","journal-title":"Trauma Case Rep"},{"key":"724_CR42","doi-asserted-by":"publisher","first-page":"386","DOI":"10.1097\/BOT.0000000000001223","volume":"32","author":"PM Mitchell","year":"2018","unstructured":"Mitchell PM, Lee AK, Collinge CA et al (2018) Early comparative outcomes of carbon fiber-reinforced polymer plate in the fixation of distal femur fractures. J Orthop Trauma 32:386\u2013390","journal-title":"J Orthop Trauma"},{"issue":"Suppl 6","key":"724_CR43","doi-asserted-by":"publisher","first-page":"S36","DOI":"10.1016\/j.injury.2014.10.020","volume":"45","author":"M Caforio","year":"2014","unstructured":"Caforio M, Perugia D, Colombo M et al (2014) Preliminary experience with Piccolo Composite\u2122, a radiolucent distal fibula plate, in ankle fractures. Injury 45(Suppl 6):S36-38","journal-title":"Injury"},{"key":"724_CR44","doi-asserted-by":"publisher","first-page":"1249","DOI":"10.1016\/j.injury.2017.03.035","volume":"48","author":"M Guzzini","year":"2017","unstructured":"Guzzini M, Lanzetti RM, Lupariello D et al (2017) Comparison between carbon-peek plate and conventional stainless steal plate in ankle fractures. A prospective study of two years follow up. Injury 48:1249\u20131252","journal-title":"Injury"},{"key":"724_CR45","doi-asserted-by":"publisher","first-page":"223","DOI":"10.1177\/1938640017718343","volume":"11","author":"ZW Pinter","year":"2018","unstructured":"Pinter ZW, Smith KS, Hudson PW et al (2018) A retrospective case series of carbon fiber plate fixation of ankle fractures. Foot Ankle Spec 11:223\u2013229","journal-title":"Foot Ankle Spec"},{"key":"724_CR46","doi-asserted-by":"publisher","first-page":"241","DOI":"10.1186\/s12957-018-1545-9","volume":"16","author":"CJ Laux","year":"2018","unstructured":"Laux CJ, Hodel SM, Farshad M et al (2018) Carbon fibre\/polyether ether ketone (CF\/PEEK) implants in orthopaedic oncology. World J Surg Oncol 16:241","journal-title":"World J Surg Oncol"},{"key":"724_CR47","doi-asserted-by":"publisher","first-page":"18969","DOI":"10.1038\/s41598-022-23519-9","volume":"12","author":"Z Rijs","year":"2022","unstructured":"Rijs Z, Weekhout A, Lozano-Calderon SA et al (2022) Complications of patients with bone tumors treated with carbon-fiber plates: an international multicenter study. Sci Rep 12:18969","journal-title":"Sci Rep"},{"key":"724_CR48","doi-asserted-by":"publisher","first-page":"247","DOI":"10.1002\/micr.30487","volume":"40","author":"B Barnds","year":"2020","unstructured":"Barnds B, Johnson A, Rosenthal H et al (2020) Ipsilateral rotational double-barrel fibula autograft for limb salvage in a pediatric patient with lower extremity intramedullary osteosarcoma: a case report. Microsurgery 40:247\u2013251","journal-title":"Microsurgery"},{"key":"724_CR49","doi-asserted-by":"publisher","first-page":"4959","DOI":"10.3390\/jcm11174959","volume":"11","author":"CM Yeung","year":"2022","unstructured":"Yeung CM, Bhashyam AR, Patel SS et al (2022) Carbon fiber implants in orthopaedic oncology. J Clin Med 11:4959","journal-title":"J Clin Med"},{"key":"724_CR50","doi-asserted-by":"publisher","first-page":"442","DOI":"10.3390\/children8060442","volume":"8","author":"C Zoccali","year":"2021","unstructured":"Zoccali C, Careri S, Attala D et al (2021) A new proximal femur reconstruction technique after bone tumor resection in a very small patient: an exemplificative case. Children 8:442","journal-title":"Children"},{"key":"724_CR51","doi-asserted-by":"publisher","first-page":"118","DOI":"10.1007\/s00776-005-0984-7","volume":"11","author":"HK Uhthoff","year":"2006","unstructured":"Uhthoff HK, Poitras P, Backman DS (2006) Internal plate fixation of fractures: short history and recent developments. J Orthop Sci 11:118\u2013126","journal-title":"J Orthop Sci"},{"key":"724_CR52","doi-asserted-by":"publisher","first-page":"675","DOI":"10.1007\/s12178-020-09671-7","volume":"13","author":"NO Sarpong","year":"2020","unstructured":"Sarpong NO, Herndon CL, Held MB et al (2020) What is the learning curve for new technologies in total joint arthroplasty? A Review. Curr Rev Musculoskelet Med 13:675\u2013679","journal-title":"A Review Curr Rev Musculoskelet Med"},{"key":"724_CR53","doi-asserted-by":"publisher","first-page":"1095","DOI":"10.1017\/S0266462300103149","volume":"16","author":"CR Ramsay","year":"2000","unstructured":"Ramsay CR, Grant AM, Wallace SA et al (2000) Assessment of the learning curve in health technologies. A systematic review. Int J Technol Assess Health Care 16:1095\u20131108","journal-title":"Int J Technol Assess Health Care"},{"key":"724_CR54","doi-asserted-by":"publisher","first-page":"e260","DOI":"10.1097\/BOT.0000000000002320","volume":"36","author":"LN Herzog","year":"2022","unstructured":"Herzog LN, Traven SA, Walton ZJ et al (2022) The use of carbon fiber implants for impending or existing pathologic fractures. J Orthop Trauma 36:e260\u2013e264","journal-title":"J Orthop Trauma"},{"key":"724_CR55","doi-asserted-by":"publisher","first-page":"1721","DOI":"10.1002\/bjs.11009","volume":"105","author":"SML de Mik","year":"2018","unstructured":"de Mik SML, Stubenrouch FE, Balm R et al (2018) Systematic review of shared decision-making in surgery. Br J Surg 105:1721\u20131730","journal-title":"Br J Surg"},{"key":"724_CR56","doi-asserted-by":"publisher","DOI":"10.1136\/bmjopen-2021-050801","volume":"11","author":"K Woudstra","year":"2021","unstructured":"Woudstra K, Tummers M, Rovers MM et al (2021) Innovators\u2019 views on involving users and patients in surgical device development: a qualitative interview study. BMJ Open 11:e050801","journal-title":"BMJ Open"}],"container-title":["Journal of Orthopaedics and Traumatology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s10195-023-00724-4.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s10195-023-00724-4\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s10195-023-00724-4.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,11,19]],"date-time":"2023-11-19T16:02:00Z","timestamp":1700409720000},"score":1,"resource":{"primary":{"URL":"https:\/\/jorthoptraumatol.springeropen.com\/articles\/10.1186\/s10195-023-00724-4"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,8,11]]},"references-count":56,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2023,12]]}},"alternative-id":["724"],"URL":"https:\/\/doi.org\/10.1186\/s10195-023-00724-4","relation":{},"ISSN":["1590-9999"],"issn-type":[{"value":"1590-9999","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,8,11]]},"assertion":[{"value":"17 April 2023","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"21 July 2023","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"11 August 2023","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Not applicable.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Not applicable.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"Disclosures SLC: Paid consultant ONKOS, paid consultant illuminOss, paid speaker Carbofix. All other authors declare that they have no conflict of interest.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"42"}}