{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,18]],"date-time":"2026-03-18T00:11:25Z","timestamp":1773792685864,"version":"3.50.1"},"reference-count":43,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2023,12,13]],"date-time":"2023-12-13T00:00:00Z","timestamp":1702425600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2023,12,13]],"date-time":"2023-12-13T00:00:00Z","timestamp":1702425600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["J Orthop Traumatol"],"abstract":"<jats:title>Abstract<\/jats:title><jats:sec>\n                <jats:title>Background<\/jats:title>\n                <jats:p>Transforaminal lumbar interbody fusion (TLIF), a commonly used procedure in spine surgery, has the advantage of a lower incidence of nerve lesions compared to the posterior lumbar interbody fusion (PLIF) technique. The intersomatic arthrodesis has always been carried out with a single tantalum cage normally used for PLIF. Tantalum is a metal that is particularly used in orthopedic surgery. It has a modulus of elasticity similar to marrow and leads to high primary stability of the implant.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Materials and methods<\/jats:title>\n                <jats:p>Our study was a retrospective monocentric observational study evaluating\u00a0clinical and radiological outcomes of tantalum cages in a modified TLIF technique with posterior instrumentation and autologous and\/or homologous posterolateral bone grafting. The aim of the study was to evaluate clinical outcomes and the increase in or redistribution of lumbar lordosis. The intersomatic arthrodesis was always carried out with a single tantalum cage normally used for PLIF to reduce the neurological risk. We retrospectively studied 105 patients who were treated with a modified unilateral TLIF approach by two surgeons between 2013 and 2018. We evaluated the Oswestry Disability Index (ODI), Visual Analogue Scale\u00a0(VAS) for back pain, global lumbar lordosis, lordosis of L4\u2013sacrum, segmental lordosis of functional motion units that underwent arthrodesis, pelvic tilt, pelvic incidence, and the sacral slope in 77 patients. All patients were suffering from grade III or IV Pfirrmann, instability, or foraminal post-laminectomy stenosis and\/or grade I\u2013II degenerative spondylolisthesis or low-grade isthmic spondylolisthesis. They had no significant sagittal imbalance, with a sagittal vertical axis (SVA) of\u2009&lt;\u20095 mm. The average follow-up duration was 30\u00a0months.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Results<\/jats:title>\n                <jats:p>We achieved excellent clinical results, with only four cases of failure (5.2%). Moreover, we noticed a statistically significant redistribution of lumbar lordosis, with an average percentage increase in L4\u2013S1 lordosis equal to 19.9% (<jats:italic>P<\/jats:italic>\u2009&lt;\u20090.001), an average increase in the L4\u2013S1\/Lumbar\u00a0lordosis\u00a0(LL) ratio from 0.53 to 0.63 (<jats:italic>P<\/jats:italic>\u2009&lt;\u20090.001), and a mean percentage increase in sacral slope equal to 7.6% (<jats:italic>P<\/jats:italic>\u2009&lt;\u20090.001).<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Conclusion<\/jats:title>\n                <jats:p> Thanks to the properties of tantalum, our modified single-portal TLIF technique is a valid surgical solution to obtain a solid arthrodesis and restore the correct lumbar lordosis distribution while reducing neurological complications and the number of failures.<\/jats:p>\n                <jats:p><jats:italic>Level of evidence<\/jats:italic>: 4<\/jats:p>\n                <jats:p><jats:italic>Trial registration statement<\/jats:italic>: retrospective observational study, no trial registration.<\/jats:p>\n              <\/jats:sec>","DOI":"10.1186\/s10195-023-00741-3","type":"journal-article","created":{"date-parts":[[2023,12,13]],"date-time":"2023-12-13T16:02:37Z","timestamp":1702483357000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":7,"title":["Transforaminal lumbar interbody fusion with a tantalum cage: lumbar lordosis redistribution and sacral slope restoration with a modified posterior technique"],"prefix":"10.1186","volume":"24","author":[{"given":"Marcello","family":"Ferraro","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-4886-4233","authenticated-orcid":false,"given":"Francesco","family":"Puglia","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Andrea","family":"Della Valle","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Vincenzo","family":"Cerbone","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Alfonso","family":"Cicatelli","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Donata Rita","family":"Peroni","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Davide","family":"Cecconi","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Bernardo","family":"Misaggi","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Giovanni Andrea","family":"La Maida","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2023,12,13]]},"reference":[{"issue":"6","key":"741_CR1","doi-asserted-by":"publisher","first-page":"673","DOI":"10.3171\/spi.2005.2.6.0673","volume":"2","author":"DK Resnick","year":"2005","unstructured":"Resnick DK, Choudhri TF, Dailey AT, Groff MW, Khoo L, Matz PG, Hadley MN (2005) Guidelines for the performance of fusion procedures for degenerative disease of the lumbar spine. Part 8: lumbar fusion for disc herniation and radiculopathy. J Neurosurg Spine 2(6):673\u2013678","journal-title":"J Neurosurg Spine"},{"issue":"1","key":"741_CR2","doi-asserted-by":"publisher","first-page":"67","DOI":"10.3171\/2014.4.SPINE14276","volume":"21","author":"PV Mummaneni","year":"2014","unstructured":"Mummaneni PV, Dhall SS, Eck JC, Groff MW, Ghogawala Z, Watters WC III, Kaiser MG (2014) Guideline update for the performance of fusion procedures for degenerative disease of the lumbar spine. Part 11: Interbody techniques for lumbar fusion. J Neurosurg Spine 21(1):67\u201374","journal-title":"J Neurosurg Spine"},{"key":"741_CR3","doi-asserted-by":"publisher","first-page":"11","DOI":"10.1016\/j.jocn.2017.06.013","volume":"44","author":"I Teng","year":"2017","unstructured":"Teng I, Han J, Phan K, Mobbs R (2017) A meta-analysis comparing ALIF, PLIF, TLIF and LLIF. J Clin Neurosci 44:11\u201317","journal-title":"J Clin Neurosci"},{"issue":"4","key":"741_CR4","doi-asserted-by":"publisher","first-page":"395","DOI":"10.1007\/s10195-017-0464-9","volume":"18","author":"Y Yang","year":"2017","unstructured":"Yang Y, Zhang L, Liu B, Pang M, Xie P et al (2017) Hidden and overall haemorrhage following minimally invasive and open transforaminal lumbar interbody fusion. J Orthop Traumatol 18(4):395\u2013400","journal-title":"J Orthop Traumatol"},{"issue":"1","key":"741_CR5","doi-asserted-by":"publisher","first-page":"60","DOI":"10.3171\/spi.1999.91.1.0060","volume":"91","author":"V Rajaraman","year":"1999","unstructured":"Rajaraman V, Vingan R, Roth P, Heary RF, Conklin L, Jacobs GB (1999) Visceral and vascular complications resulting from anterior lumbar interbody fusion. J Neurosurg Spine 91(1):60\u201364","journal-title":"J Neurosurg Spine"},{"issue":"4","key":"741_CR6","doi-asserted-by":"publisher","first-page":"379","DOI":"10.3171\/SPI-07\/10\/379","volume":"7","author":"PC Hsieh","year":"2007","unstructured":"Hsieh PC, Koski TR, O\u2019Shaughnessy BA, Sugrue P, Salehi S, Ondra S, Liu JC (2007) Anterior lumbar interbody fusion in comparison with transforaminal lumbar interbody fusion: implications for the restoration of foraminal height, local disc angle, lumbar lordosis, and sagittal balance. J Neurosurg Spine 7(4):379\u2013386","journal-title":"J Neurosurg Spine"},{"issue":"2","key":"741_CR7","doi-asserted-by":"publisher","first-page":"147","DOI":"10.1055\/s-0035-1557141","volume":"6","author":"RJ Mobbs","year":"2016","unstructured":"Mobbs RJ, Phan K, Daly D, Rao PJ, Lennox A (2016) Approach-related complications of anterior lumbar interbody fusion: results of a combined spine and vascular surgical team. Global Spine J 6(2):147\u2013154","journal-title":"Global Spine J"},{"issue":"1","key":"741_CR8","doi-asserted-by":"publisher","first-page":"14","DOI":"10.1055\/s-0035-1555656","volume":"6","author":"RJ Mobbs","year":"2016","unstructured":"Mobbs RJ, Phan K, Thayaparan GK, Rao PJ (2016) Anterior lumbar interbody fusion as a salvage technique for pseudarthrosis following posterior lumbar fusion surgery. Global Spine J 6(1):14\u201320","journal-title":"Global Spine J"},{"issue":"6","key":"741_CR9","doi-asserted-by":"publisher","first-page":"406","DOI":"10.1016\/j.cuor.2008.07.006","volume":"22","author":"TS Madhu","year":"2008","unstructured":"Madhu TS (2008) Posterior and anterior lumbar interbody fusion. Curr Orthopaedics 22(6):406\u2013413","journal-title":"Curr Orthopaedics"},{"issue":"11","key":"741_CR10","doi-asserted-by":"publisher","first-page":"1712","DOI":"10.1016\/j.spinee.2017.06.018","volume":"17","author":"LDK Suzanne","year":"2017","unstructured":"Suzanne LDK, Sander MJVK, Kim R, Inge JMHC, Wouter van Hemert LW, Robde A, van Santbrink H (2017) Transforaminal lumbar interbody fusion (TLIF) versus posterior lumbar interbody fusion (PLIF) in lumbar spondylolisthesis: a systematic review and meta-analysis. Spine J 17(11):1712\u20131721","journal-title":"Spine J"},{"issue":"5","key":"741_CR11","doi-asserted-by":"publisher","first-page":"1017","DOI":"10.1007\/s00586-015-3903-4","volume":"24","author":"K Phan","year":"2015","unstructured":"Phan K, Rao PJ, Kam AC, Mobbs RJ (2015) Minimally invasive versus open transforaminal lumbar interbody fusion for treatment of degenerative lumbar disease: systematic review and meta-analysis. Eur Spine J 24(5):1017\u20131030","journal-title":"Eur Spine J"},{"key":"741_CR12","doi-asserted-by":"publisher","first-page":"167","DOI":"10.1016\/0267-6605(94)90113-9","volume":"16","author":"J Black","year":"1994","unstructured":"Black J (1994) Biological performance of tantalum. Clin Mater 16:167\u2013173","journal-title":"Clin Mater"},{"key":"741_CR13","doi-asserted-by":"publisher","first-page":"E571","DOI":"10.1097\/BRS.0b013e318240f981","volume":"37","author":"SK Sinclair","year":"2012","unstructured":"Sinclair SK, Konz GJ, Dawson JM, Epperson RT, Bloebaum RD (2012) Host bone response to polyetheretherketone versus porous tantalum implants for cervical spinal fusion in a goat model. Spine 37:E571\u2013E580","journal-title":"Spine"},{"key":"741_CR14","doi-asserted-by":"publisher","first-page":"180","DOI":"10.1002\/1097-4636(2001)58:2<180::AID-JBM1005>3.0.CO;2-5","volume":"58","author":"LD Zardiackas","year":"2001","unstructured":"Zardiackas LD, Parsell DE, Dillon LD, Mitchell DW, Nunnery LA, Poggie R (2001) Structure, metallurgy, and mechanical properties of a porous tantalum foam. J Biomed Mater Res 58:180\u2013187","journal-title":"J Biomed Mater Res"},{"key":"741_CR15","doi-asserted-by":"crossref","unstructured":"Brown TD, Heiner AD, Poggie RA, Fitzpatrick DC, Ahn PB, Zhang Y (1999) Interfacial frictional behavior: cancellous bone, cortical bone, and a novel porous tantalum biomaterial. J Musculoskelet Res 03:245\u2013251","DOI":"10.1142\/S0218957799000269"},{"key":"741_CR16","doi-asserted-by":"publisher","first-page":"662","DOI":"10.3928\/0147-7447-20050701-13","volume":"28","author":"JB Stiehl","year":"2005","unstructured":"Stiehl JB (2005) Trabecular metal in hip reconstructive surgery. Orthopedics 28:662\u2013670","journal-title":"Orthopedics"},{"key":"741_CR17","doi-asserted-by":"publisher","first-page":"907","DOI":"10.1302\/0301-620X.81B5.0810907","volume":"81B","author":"JD Bobyn","year":"1999","unstructured":"Bobyn JD, Stackpool GJ, Hacking SA, Tanzer M, Krygier JJ (1999) Characteristics of bone ingrowth and interface mechanics of a new porous tantalum biomaterial. J Bone Joint Surg 81B:907\u2013914","journal-title":"J Bone Joint Surg"},{"issue":"5","key":"741_CR18","doi-asserted-by":"publisher","first-page":"505","DOI":"10.4103\/0019-5413.101032","volume":"46","author":"CG Paganias","year":"2012","unstructured":"Paganias CG, Tsakotos GA, Koutsostathis SD, Macheras GA (2012) Osseous integration in porous tantalum implants. Indian J Orthop 46(5):505\u2013513","journal-title":"Indian J Orthop"},{"issue":"1","key":"741_CR19","doi-asserted-by":"publisher","first-page":"23","DOI":"10.1186\/s10195-019-0530-6","volume":"20","author":"AM Ebied","year":"2019","unstructured":"Ebied AM, Ebied AA, Marei S, Smith E (2019) Enhancing biology and providing structural support for acetabular reconstruction in single-stage revision for infection. J Orthop Traumatol 20(1):23","journal-title":"J Orthop Traumatol"},{"issue":"27","key":"741_CR20","doi-asserted-by":"publisher","first-page":"4671","DOI":"10.1016\/j.biomaterials.2006.04.041","volume":"27","author":"BR Levine","year":"2006","unstructured":"Levine BR et al (2006) Experimental and clinical performance of porous tantalum in orthopedic surgery. Biomaterials 27(27):4671\u20134681","journal-title":"Biomaterials"},{"issue":"5","key":"741_CR21","doi-asserted-by":"publisher","first-page":"331","DOI":"10.1016\/S1529-9430(01)00113-9","volume":"1","author":"KS Sidhu","year":"2001","unstructured":"Sidhu KS et al (2001) Anterior cervical interbody fusion with rhBMP-2 and tantalum in a goat model. Spine J 1(5):331\u2013340","journal-title":"Spine J"},{"issue":"14","key":"741_CR22","doi-asserted-by":"publisher","first-page":"E392","DOI":"10.1097\/01.brs.0000170588.80377.3f","volume":"30","author":"X Zou","year":"2005","unstructured":"Zou X et al (2005) Pedicle screw fixation enhances anterior lumbar interbody fusion with porous tantalum cages: an experimental study in pigs. Spine 30(14):E392\u2013E399. https:\/\/doi.org\/10.1097\/01.brs.0000170588.80377.3f","journal-title":"Spine"},{"key":"741_CR23","doi-asserted-by":"crossref","unstructured":"Zou X et al (2004) Bone ingrowth characteristics of porous tantalum and carbon fiber interbody devices: an experimental study in pigs. Spine J 4(1):99\u2013105","DOI":"10.1016\/S1529-9430(03)00407-8"},{"issue":"5","key":"741_CR24","doi-asserted-by":"publisher","first-page":"418","DOI":"10.1080\/02688690310001611206","volume":"17","author":"C Wigfield","year":"2003","unstructured":"Wigfield C et al (2003) Clinical experience with porous tantalum cervical interbody implants in a prospective randomized controlled trial. Br J Neurosurg 17(5):418\u2013425","journal-title":"Br J Neurosurg"},{"issue":"7","key":"741_CR25","doi-asserted-by":"publisher","first-page":"476","DOI":"10.1097\/00005131-200608000-00005","volume":"20","author":"AS Thomas","year":"2006","unstructured":"Thomas AS, Bruce R, Gert M, Manfred K (2006) Bacterial adherence to tantalum versus commonly used orthopedic metallic implant materials. J Orthop Trauma 20(7):476\u2013484","journal-title":"J Orthop Trauma"},{"issue":"2","key":"741_CR26","doi-asserted-by":"publisher","first-page":"332","DOI":"10.1002\/jbm.a.31850","volume":"88","author":"TA Schildhauer","year":"2009","unstructured":"Schildhauer TA, Peter E, Muhr G, K\u00f6ller M (2009) Activation of human leukocytes on tantalum trabecular metal in comparison to commonly used orthopedic metal implant materials. J Biomed Mater Res A 88(2):332\u2013341","journal-title":"J Biomed Mater Res A"},{"issue":"9","key":"741_CR27","doi-asserted-by":"publisher","first-page":"1153","DOI":"10.1302\/0301-620X.99B9.BJJ-2016-1309.R1","volume":"99-B","author":"PL Harrison","year":"2017","unstructured":"Harrison PL, Harrison T, Stockley I, Smith TJ (2017) Does tantalum exhibit any intrinsic antimicrobial or antibiofilm properties? Bone Joint J. 99-B(9):1153\u20131156","journal-title":"Bone Joint J."},{"key":"741_CR28","doi-asserted-by":"crossref","unstructured":"Fairbank JC, Pynsent PB (2000) The Oswestry Disability Index. Spine 25:2940\u20132952","DOI":"10.1097\/00007632-200011150-00017"},{"issue":"1","key":"741_CR29","first-page":"2","volume":"1","author":"RJ Mobbs","year":"2015","unstructured":"Mobbs RJ, Phan K, Malham G, Seex K, Rao JP (2015) Lumbar interbody fusion: techniques, indications and comparison of interbody fusion options including PLIF, TLIF, MI-TLIF, OLIF\/ATP, LLIF and ALIF. J Spine Surg 1(1):2\u201318","journal-title":"J Spine Surg"},{"key":"741_CR30","doi-asserted-by":"publisher","first-page":"311","DOI":"10.1007\/s00402-014-1925-8","volume":"134","author":"K Kida","year":"2014","unstructured":"Kida K, Tadokoro N, Kumon M et al (2014) Can cantilever transforaminal lumbar interbody fusion (C-TLIF) maintain segmental lordosis for degenerative spondylolisthesis on a long-term basis? Arch Orthop Trauma Surg 134:311\u2013315","journal-title":"Arch Orthop Trauma Surg"},{"key":"741_CR31","doi-asserted-by":"publisher","first-page":"907","DOI":"10.1302\/0301-620X.81B5.0810907","volume":"81","author":"JD Bobyn","year":"1999","unstructured":"Bobyn JD, Stackpool GJ, Hacking SA et al (1999) Characteristics of bone ingrowth and interface mechanics of a new porous tantalum biomaterial. J Bone Joint Surg Br 81:907\u2013914","journal-title":"J Bone Joint Surg Br"},{"key":"741_CR32","first-page":"216","volume":"31","author":"R Cohen","year":"2002","unstructured":"Cohen R (2002) A porous tantalum trabecular metal: basic science. Am J Orthop (Belle Mead NJ) 31:216\u2013217","journal-title":"Am J Orthop (Belle Mead NJ)"},{"issue":"5","key":"741_CR33","doi-asserted-by":"publisher","first-page":"239","DOI":"10.1097\/BSD.0b013e318241e70f","volume":"26","author":"MK Kasliwal","year":"2013","unstructured":"Kasliwal MK, Baskin DS, Traynelis VC (2013) Failure of porous tantalum cervical interbody fusion devices. J Spinal Disord Tech 26(5):239","journal-title":"J Spinal Disord Tech"},{"key":"741_CR34","doi-asserted-by":"publisher","first-page":"167","DOI":"10.1016\/0267-6605(94)90113-9","volume":"16","author":"J Black","year":"1994","unstructured":"Black J (1994) Biological performance of tantulum. Clin Mater 16:167","journal-title":"Clin Mater"},{"key":"741_CR35","unstructured":"Tummler H, Thull R (1985) Model of the metal\/tissue connection of implants made of titanium or tantalum. In: Christel P, Meunier A, Lee AJC (eds) Biological and biomechanical performances of biomaterials. Elsevier, Amsterdam, pp 403\u2013408"},{"key":"741_CR36","doi-asserted-by":"publisher","first-page":"609","DOI":"10.1002\/jor.21251","volume":"28","author":"KB Sagomonyants","year":"2011","unstructured":"Sagomonyants KB, Hakim-Zargar M, Jhaveri A, Aronow MS, Gronowicz G (2011) Porous tantalum stimulates the proliferation and osteogenesis of osteoblasts from elderly female patients. J Orthop Res 28:609\u2013616","journal-title":"J Orthop Res"},{"issue":"1","key":"741_CR37","doi-asserted-by":"publisher","first-page":"83","DOI":"10.21037\/jss-22-24","volume":"9","author":"F Jadhakhan","year":"2023","unstructured":"Jadhakhan F, Bell D, Rushton A (2023) Outcomes of surgical intervention for degenerative lumbar spondylolisthesis: a comparative analysis of different surgical fixation techniques. J Spine Surg 9(1):83\u201397","journal-title":"J Spine Surg"},{"issue":"7","key":"741_CR38","doi-asserted-by":"publisher","first-page":"1250","DOI":"10.1016\/j.spinee.2018.02.018","volume":"18","author":"CM Kirk","year":"2018","unstructured":"Kirk CM, Easley J, Seim HB, Regan D, Berven SH, Hsu WH, Mroz TE, Puttlitz CM (2018) Bony ingrowth potential of 3D-printed porous titanium alloy: a direct comparison of interbody cage materials in an in vivo ovine lumbar fusion model. Spine J 18(7):1250\u20131260","journal-title":"Spine J"},{"key":"741_CR39","doi-asserted-by":"publisher","first-page":"147","DOI":"10.1016\/j.spinee.2010.07.379","volume":"10","author":"JP Malloy","year":"2010","unstructured":"Malloy JP, Beutler W, Peppelman W, Harris R, Slotkin E, Gillette J (2010) Clinical outcomes with porous tantalum in lumbar interbody fusion. Spine J 10:147\u2013148","journal-title":"Spine J"},{"issue":"11","key":"741_CR40","doi-asserted-by":"publisher","first-page":"1245","DOI":"10.1097\/00007632-199806010-00014","volume":"23","author":"AD Levi","year":"1998","unstructured":"Levi AD, Choi WG, Keller PJ, Heiserman JE, Sonntag VK, Dickman C (1998) The radiographic and imaging characteristics of porous tantalum implants within the human cervical spine. Spine 23(11):1245\u20131250 (discussion 1251)","journal-title":"Spine"},{"key":"741_CR41","doi-asserted-by":"publisher","first-page":"2101","DOI":"10.1038\/s41598-022-05988-0","volume":"12","author":"JM Sousa","year":"2022","unstructured":"Sousa JM, Ribeiro H, Silva JL, Nogueira P, Consci\u00eancia JG (2022) Clinical outcomes, complications and fusion rates in endoscopic assisted intraforaminal lumbar interbody fusion (iLIF) versus minimally invasive transforaminal lumbar interbody fusion (MI-TLIF): systematic review and meta-analysis. Sci Rep 12:2101","journal-title":"Sci Rep"},{"key":"741_CR42","first-page":"523728","volume":"2015","author":"JH Lee","year":"2015","unstructured":"Lee JH, Lee DO, Lee JH, Shim HJ (2015) Effects of lordotic angle of a cage on sagittal alignment and clinical outcome in one level posterior lumbar interbody fusion with pedicle screw fixation. Biomed Res Int 2015:523728","journal-title":"Biomed Res Int"},{"key":"741_CR43","doi-asserted-by":"publisher","first-page":"596","DOI":"10.1016\/j.wneu.2019.03.284","volume":"127","author":"MA Alvi","year":"2019","unstructured":"Alvi MA, Kurian SJ, Wahood W, Goyal A, Elder BD, Bydon M (2019) Assessing the difference in clinical and radiologic outcomes between expandable cage and nonexpandable cage among patients undergoing minimally invasive transforaminal interbody fusion: a systematic review and meta-analysis. World Neurosurg 127:596-606.e1","journal-title":"World Neurosurg"}],"container-title":["Journal of Orthopaedics and Traumatology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s10195-023-00741-3.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s10195-023-00741-3\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s10195-023-00741-3.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,12,13]],"date-time":"2023-12-13T16:02:43Z","timestamp":1702483363000},"score":1,"resource":{"primary":{"URL":"https:\/\/jorthoptraumatol.springeropen.com\/articles\/10.1186\/s10195-023-00741-3"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,12,13]]},"references-count":43,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2023,12]]}},"alternative-id":["741"],"URL":"https:\/\/doi.org\/10.1186\/s10195-023-00741-3","relation":{},"ISSN":["1590-9999"],"issn-type":[{"value":"1590-9999","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,12,13]]},"assertion":[{"value":"22 February 2023","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"19 November 2023","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"13 December 2023","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The Ethics Committee of the University of Milan reviewed the study and decided that it did not require formal ethics approval (as it was within the remit of the audit) and did not require formal patient consent (as it involved a retrospective review of anonymized data).","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Not applicable.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare that they have no competing interests.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"62"}}