{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,16]],"date-time":"2026-06-16T22:00:27Z","timestamp":1781647227156,"version":"3.54.5"},"reference-count":17,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2026,4,11]],"date-time":"2026-04-11T00:00:00Z","timestamp":1775865600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2026,4,14]],"date-time":"2026-04-14T00:00:00Z","timestamp":1776124800000},"content-version":"vor","delay-in-days":3,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"name":"Johann Wolfgang Goethe-Universit\u00e4t, Frankfurt am Main"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Int J Emerg Med"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Background<\/jats:title>\n                    <jats:p>Endotracheal intubation is a high-stakes intervention in emergency airway management, with patient safety closely linked to first-pass success and avoidance of repeated attempts. The Frankfurt Intubation Device (FID) is a bougie-inspired intubation device intended to provide fast protection against aspiration once positioned in the trachea.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>This dual-center randomized crossover simulation study used an easy-to-intubate airway manikin. Ninety participants were divided into three groups of different experience (anesthesiologists, non-physician critical care staff, and medical students) to perform intubation with the Frankfurt Intubation Device (FID) and a standard endotracheal tube with stylet in randomized order. The primary outcome was non-inferiority of time to airway protection, measured from laryngoscope insertion to inflation of a cuffed device positioned in the trachea (T2; \u0394\u2009=\u20095\u00a0s). Secondary outcomes included first-pass success, tooth damage, and exploratory assessment of training effects, with additional time-based outcomes assessed descriptively.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>Across all participants, the FID was non-inferior to the endotracheal tube with stylet for T2 (mean paired difference\u2009\u2212\u20090.77\u00a0s, 95% CI\u2009\u2212\u20092.50 to 0.97; non-inferiority margin 5\u00a0s). Exploratory analyses demonstrated consistent non-inferiority for T2 across experience groups (G1\u2013G3) and randomization sequences. First-pass success was high in both arms (FID 96.7% vs. ET+stylet 94.4%), while tooth damage occurred less frequently with the FID (7.8% vs. 14.4%). Training effects were observed in the simulator.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion<\/jats:title>\n                    <jats:p>In this standardized simulation study using an easy-to-intubate airway manikin, the Frankfurt Intubation Device demonstrated non-inferiority to conventional endotracheal intubation with stylet for time to airway protection. Secondary findings support continued staged evaluation of the FID, particularly in more challenging airway scenarios and among users with limited airway experience, where differences in procedural performance may become more apparent.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Trial registration<\/jats:title>\n                    <jats:p>Not applicable (simulation study).<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1186\/s12245-026-01208-y","type":"journal-article","created":{"date-parts":[[2026,4,11]],"date-time":"2026-04-11T12:35:20Z","timestamp":1775910920000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Time to intubate with an innovative intubation device: a dual-center randomized crossover non-inferiority simulation study"],"prefix":"10.1186","volume":"19","author":[{"given":"Hans Magnus","family":"Haveraaen","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Udo","family":"Seel","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Broder","family":"Romeike","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sebastian","family":"Zinn","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Haitham","family":"Mutlak","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kai","family":"Zacharowski","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Vanessa","family":"Neef","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Benjamin","family":"Friedrichson","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jan Andreas","family":"Kloka","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,4,11]]},"reference":[{"key":"1208_CR1","doi-asserted-by":"publisher","first-page":"63","DOI":"10.1016\/j.resuscitation.2015.11.005","volume":"99","author":"ML Buis","year":"2016","unstructured":"Buis ML, Maissan IM, Hoeks SE, et al. Defining the learning curve for endotracheal intubation using direct laryngoscopy: A systematic review. Resuscitation. 2016;99:63\u201371. https:\/\/doi.org\/10.1016\/j.resuscitation.2015.11.005.","journal-title":"Resuscitation"},{"key":"1208_CR2","doi-asserted-by":"publisher","first-page":"71","DOI":"10.1111\/acem.12055","volume":"20","author":"JC Sakles","year":"2013","unstructured":"Sakles JC, Chiu S, Mosier J, et al. The importance of first pass success when performing orotracheal intubation in the emergency department. Acad Emerg Med. 2013;20:71\u20138. https:\/\/doi.org\/10.1111\/acem.12055.","journal-title":"Acad Emerg Med"},{"key":"1208_CR3","doi-asserted-by":"publisher","first-page":"749","DOI":"10.1016\/j.annemergmed.2012.04.005","volume":"60","author":"K Hasegawa","year":"2012","unstructured":"Hasegawa K, et al. Association between repeated intubation attempts and adverse events in emergency departments: a multicenter prospective observational study. Ann Emerg Med. 2012;60:749\u2013e7542. https:\/\/doi.org\/10.1016\/j.annemergmed.2012.04.005.","journal-title":"Ann Emerg Med"},{"key":"1208_CR4","unstructured":"Timmermann A, et al. AWMF Leitlinie \u201ePr\u00e4hospitales Atemwegsmanagement. 2019."},{"key":"1208_CR5","doi-asserted-by":"publisher","first-page":"617","DOI":"10.1097\/ALN.0b013e31822e9659","volume":"115","author":"TM Cook","year":"2011","unstructured":"Cook TM, Woodall N, Frerk C, Fourth National Audit Project. Major complications of airway management in the United Kingdom: Report and findings. Anesthesiology. 2011;115:617\u201331. https:\/\/doi.org\/10.1097\/ALN.0b013e31822e9659.","journal-title":"Anesthesiology"},{"key":"1208_CR6","doi-asserted-by":"publisher","unstructured":"Russotto V, Myatra SN, Laffey JG, et al. Intubation practices and adverse peri-intubation events in critically Ill patients from 29 countries. JAMA. 2021;325(12):1164\u201372. https:\/\/doi.org\/10.1001\/jama.2021.1727.","DOI":"10.1001\/jama.2021.1727"},{"key":"1208_CR7","doi-asserted-by":"publisher","first-page":"2179","DOI":"10.1001\/jama.2018.6496","volume":"319","author":"BE Driver","year":"2018","unstructured":"Driver BE, et al. Effect of use of a bougie vs endotracheal tube and stylet on first-attempt intubation success among patients with difficult airways undergoing emergency intubation: A randomized clinical trial. JAMA. 2018;319:2179\u201389. https:\/\/doi.org\/10.1001\/jama.2018.6496.","journal-title":"JAMA"},{"key":"1208_CR8","doi-asserted-by":"publisher","unstructured":"von Hellmann R, Fuhr N, Maia IWA, et al. Effect of bougie use on first-attempt success in tracheal intubations: a systematic review and meta-analysis. Ann Emerg Med. 2024;83(2):132\u201344. https:\/\/doi.org\/10.1016\/j.annemergmed.2023.08.484.","DOI":"10.1016\/j.annemergmed.2023.08.484"},{"key":"1208_CR9","doi-asserted-by":"publisher","first-page":"643","DOI":"10.1097\/00000542-198804000-00038","volume":"68","author":"SM McCarroll","year":"1988","unstructured":"McCarroll SM, Lamont BJ, Buckland MR, et al. The gum-elastic bougie: old but still useful. Anesthesiology. 1988;68:643\u20134. https:\/\/doi.org\/10.1097\/00000542-198804000-00038.","journal-title":"Anesthesiology"},{"key":"1208_CR10","doi-asserted-by":"publisher","DOI":"10.1136\/bmjinnov-2024-001332","author":"JA Kloka","year":"2025","unstructured":"Kloka JA, Haveraaen HM, Romeike B, et al. Development and evaluation of the Frankfurt Intubation Device, a user-centred design for enhanced patient safety. BMJ Innovations. 2025. https:\/\/doi.org\/10.1136\/bmjinnov-2024-001332.","journal-title":"BMJ Innovations"},{"key":"1208_CR11","doi-asserted-by":"publisher","first-page":"l4378","DOI":"10.1136\/bmj.l4378","volume":"366","author":"K Dwan","year":"2019","unstructured":"Dwan K, Li T, Altman DG, Elbourne D. CONSORT 2010 statement: extension to randomised crossover trials. BMJ. 2019;366:l4378.","journal-title":"BMJ"},{"key":"1208_CR12","first-page":"28","volume":"1","author":"RR Macintosh","year":"1949","unstructured":"Macintosh RR. An aid to oral intubation. Br Med J. 1949;1:28.","journal-title":"Br Med J"},{"key":"1208_CR13","doi-asserted-by":"publisher","first-page":"608","DOI":"10.1007\/s12630-020-01828-0","volume":"68","author":"S Fong","year":"2021","unstructured":"Fong S, Li E, Violato E, Reid A, Gu Y, Guo Y. Impact of aerosol box on intubation during COVID-19: a simulation study. Can J Anesth. 2021;68:608\u201315. https:\/\/doi.org\/10.1007\/s12630-020-01828-0.","journal-title":"Can J Anesth"},{"key":"1208_CR14","doi-asserted-by":"publisher","first-page":"183","DOI":"10.1186\/s12871-020-01149-w","volume":"20","author":"JL Begley","year":"2020","unstructured":"Begley JL, Lavery KE, Nickson CP, Brewster DJ. Time to adapt in the pandemic era: a prospective randomized non-inferiority study comparing time to intubate with and without the barrier box. BMC Anesthesiol. 2020;20:183. https:\/\/doi.org\/10.1186\/s12871-020-01149-w.","journal-title":"BMC Anesthesiol"},{"issue":"5","key":"1208_CR15","doi-asserted-by":"publisher","first-page":"1019","DOI":"10.1016\/j.bja.2024.02.004","volume":"132","author":"C Hayes-Bradley","year":"2024","unstructured":"Hayes-Bradley C, McCreery M, Delorenzo A, Bowles KA. Predictive and protective factors for failing first-pass intubation in prehospital rapid sequence intubation: an aetiology and risk systematic review with meta-analysis. Br J Anaesth. 2024;132(5):1019\u201332. https:\/\/doi.org\/10.1016\/j.bja.2024.02.004.","journal-title":"Br J Anaesth"},{"issue":"5","key":"1208_CR16","doi-asserted-by":"publisher","first-page":"497","DOI":"10.1111\/1742-6723.12704","volume":"29","author":"L Park","year":"2017","unstructured":"Park L, Zeng I, Brainard A. Systematic review and meta-analysis of first-pass success rates and adverse events during emergency department intubation. Emerg Med Australas. 2017;29(5):497\u2013504. https:\/\/doi.org\/10.1111\/1742-6723.12704.","journal-title":"Emerg Med Australas"},{"key":"1208_CR17","doi-asserted-by":"crossref","unstructured":"Soar J, B\u00f6ttiger BW, Carli P, et al. European resuscitation council guidelines. 2021: Adult advanced life support. Resuscitation. 2021.","DOI":"10.1016\/j.resuscitation.2021.02.010"}],"container-title":["International Journal of Emergency Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s12245-026-01208-y","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12245-026-01208-y.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12245-026-01208-y.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,6,16]],"date-time":"2026-06-16T21:51:00Z","timestamp":1781646660000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1186\/s12245-026-01208-y"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,4,11]]},"references-count":17,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2026,12]]}},"alternative-id":["1208"],"URL":"https:\/\/doi.org\/10.1186\/s12245-026-01208-y","relation":{},"ISSN":["1865-1380"],"issn-type":[{"value":"1865-1380","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,4,11]]},"assertion":[{"value":"2 February 2026","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"2 April 2026","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"11 April 2026","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"This study involved human participants in a simulation setting (questionnaire data and video recordings of study procedures for time measurement and quality control). The Ethics Committee of the University Hospital Frankfurt waived the need for ethical approval (Ref: 2023\u2009\u2212\u20091160).","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"All participants provided written informed consent for the use of anonymized questionnaire data in scientific publications and for video recording of study procedures for study-related analysis. The videos will not be published, and no identifiable participant information is included in this manuscript.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"All authors have been involved in the design process. The FID is filed for patent by JK and US (U31030DE, 16.11.2020). The Department of Anesthesiology, Intensive Care and Pain Therapy, University Hospital Frankfurt, provided institutional support in the form of internal research funds, access to facilities and equipment, and publication costs. The Department had no role in study design, data collection, data analysis, data interpretation, or manuscript preparation.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"98"}}