{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,11]],"date-time":"2026-09-11T07:08:49Z","timestamp":1789110529472,"version":"build-2803163510"},"reference-count":27,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2026,9,10]],"date-time":"2026-09-10T00:00:00Z","timestamp":1788998400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2026,9,11]],"date-time":"2026-09-11T00:00:00Z","timestamp":1789084800000},"content-version":"vor","delay-in-days":1,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"name":"Manipal Academy of Higher Education, Manipal"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Int J Emerg Med"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Background<\/jats:title>\n                    <jats:p>Performing high-quality cardiopulmonary resuscitation (CPR) in a moving ambulance poses biomechanical and ergonomic challenges. This pilot study aimed to evaluate musculoskeletal discomfort, CPR quality, and provider posture, while exploring the experiences of healthcare providers delivering CPR in a moving ambulance.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>\n                      A mixed-methods study involving 30 Emergency Medical Service (EMS) providers and students aged 18\u201340 years trained in Basic Life Support was conducted. Participants performed CPR simulation in an in-hospital stationary setting and a moving ambulance using a Little Anne\n                      <jats:sup>\u00ae<\/jats:sup>\n                      QCPR mannequin (Laerdal Medical, Stavanger, Norway). Musculoskeletal discomfort was assessed before and after CPR in the moving ambulance using the Numerical Pain Rating Scale. CPR quality parameters, including compression score, depth, rate, recoil, and chest compression fraction, were recorded using the QCPR\n                      <jats:sup>\u00ae<\/jats:sup>\n                      app. Body posture was assessed using mean trunk and elbow angles during compression and recoil. Semi-structured interviews explored participants\u2019 experiences.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>\n                      Median pain scores increased significantly after CPR in the moving ambulance [0 (0, 2.75) before vs. 4 (0, 6) after;\n                      <jats:italic>p<\/jats:italic>\n                      \u2009&lt;\u20090.001]. The most common pain sites were the lumbar region and wrists. Chest compression score and good rate percentage were lower in the moving setting. Trunk and elbow angles showed greater flexion in the moving ambulance, with changes observed across consecutive CPR cycles. Qualitative analysis revealed themes of physical fatigue, balance issues, safety concerns, and ergonomic limitations. Participants recommended simulation-based training, improved ambulance design, and mechanical CPR devices.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion<\/jats:title>\n                    <jats:p>CPR in a moving ambulance was associated with increased musculoskeletal discomfort and lower CPR quality metrics. Ergonomic modifications, provider training, and mechanical aids may help address these challenges. Further studies with larger and more diverse populations and real-world transport conditions are warranted.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Trial registration<\/jats:title>\n                    <jats:p>Prospectively registered in Clinical Trial Registry India (CTRI\/2024\/09\/073482) on September 5th, 2024.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1186\/s12245-026-01365-0","type":"journal-article","created":{"date-parts":[[2026,9,10]],"date-time":"2026-09-10T19:18:13Z","timestamp":1789067893000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["\u201cResuscitation on the go\u201d- Musculoskeletal discomfort, CPR quality and provider experiences in a transit ambulance setting: A simulated, mixed-methods study"],"prefix":"10.1186","volume":"19","author":[{"ORCID":"https:\/\/orcid.org\/0009-0002-8336-2922","authenticated-orcid":false,"given":"Caroline Ashritha","family":"Maben","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-4363-2943","authenticated-orcid":false,"given":"Prithvishree","family":"Ravindra","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-1084-0137","authenticated-orcid":false,"given":"Abraham Samuel","family":"Babu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-9282-5450","authenticated-orcid":false,"given":"Mohammad","family":"Khalid","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0001-8993-1690","authenticated-orcid":false,"given":"B. N.","family":"Lavanya","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-3232-9308","authenticated-orcid":false,"given":"Ankit Kumar","family":"Sahu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-0100-2396","authenticated-orcid":false,"given":"Vimal","family":"Krishnan S","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,9,10]]},"reference":[{"issue":"11","key":"1365_CR1","doi-asserted-by":"publisher","first-page":"1479","DOI":"10.1016\/j.resuscitation.2010.08.006","volume":"81","author":"J Berdowski","year":"2010","unstructured":"Berdowski J, Berg RA, Tijssen JGP, Koster RW. Global incidences of out-of-hospital cardiac arrest and survival rates: Systematic review of 67 prospective studies. Resuscitation. 2010;81(11):1479\u201387.","journal-title":"Resuscitation"},{"key":"1365_CR2","doi-asserted-by":"publisher","first-page":"39","DOI":"10.1016\/j.resuscitation.2020.02.044","volume":"152","author":"T Kiguchi","year":"2020","unstructured":"Kiguchi T, Okubo M, Nishiyama C, Maconochie I, Ong MEH, Kern KB, et al. Out-of-hospital cardiac arrest across the World: First report from the International Liaison Committee on Resuscitation (ILCOR). Resuscitation. 2020;152:39\u201349.","journal-title":"Resuscitation"},{"issue":"1","key":"1365_CR3","doi-asserted-by":"publisher","first-page":"55","DOI":"10.1017\/S1049023X19005193","volume":"35","author":"S Mullin","year":"2020","unstructured":"Mullin S, Lydon S, O\u2019Connor P. The Effect of Operator Position on the Quality of Chest Compressions Delivered in a Simulated Ambulance. Prehosp Disaster Med. 2020;35(1):55\u201360.","journal-title":"Prehosp Disaster Med"},{"issue":"3","key":"1365_CR4","doi-asserted-by":"publisher","first-page":"388","DOI":"10.1080\/10903120802706104","volume":"13","author":"DE Slattery","year":"2009","unstructured":"Slattery DE, Silver A. The Hazards of Providing Care in Emergency Vehicles: An Opportunity for Reform. Prehospital Emerg Care. 2009;13(3):388\u201397.","journal-title":"Prehospital Emerg Care"},{"issue":"3","key":"1365_CR5","doi-asserted-by":"publisher","first-page":"263","DOI":"10.1016\/j.resuscitation.2010.11.003","volume":"82","author":"NH Krarup","year":"2011","unstructured":"Krarup NH, Terkelsen CJ, Johnsen SP, Clemmensen P, Olivecrona GK, Hansen TM, et al. Quality of cardiopulmonary resuscitation in out-of-hospital cardiac arrest is hampered by interruptions in chest compressions\u2014A nationwide prospective feasibility study. Resuscitation. 2011;82(3):263\u20139.","journal-title":"Resuscitation"},{"issue":"10","key":"1365_CR6","doi-asserted-by":"publisher","first-page":"e107960","DOI":"10.1371\/journal.pone.0107960","volume":"9","author":"NP Foo","year":"2014","unstructured":"Foo NP, Chang JH, Su SB, Chen KT, Cheng CF, Chen PC, et al. A Stabilization Device That Promotes the Efficiency of Cardiopulmonary Resuscitation during Ambulance Transportation to the Level as under Non-Moving Conditions. PLoS ONE. 2014;9(10):e107960.","journal-title":"PLoS ONE"},{"issue":"13","key":"1365_CR7","doi-asserted-by":"publisher","first-page":"2783","DOI":"10.7150\/ijms.59037","volume":"18","author":"CS Ho","year":"2021","unstructured":"Ho CS, Hsu YJ, Li F, Tang CC, Yang CP, Huang CC, et al. Effect of Ambulance Stretcher Bed Height Adjustment on CPR Quality and Rescuer Fatigue in a Laboratory Environment. Int J Med Sci. 2021;18(13):2783\u20138.","journal-title":"Int J Med Sci"},{"issue":"9","key":"1365_CR8","doi-asserted-by":"publisher","first-page":"e023784","DOI":"10.1136\/bmjopen-2018-023784","volume":"8","author":"JH Beom","year":"2018","unstructured":"Beom JH, Kim MJ, You JS, Lee HS, Kim JH, Park YS, et al. Evaluation of the quality of cardiopulmonary resuscitation according to vehicle driving pattern, using a virtual reality ambulance driving system: a prospective, cross-over, randomised study. BMJ Open. 2018;8(9):e023784.","journal-title":"BMJ Open"},{"issue":"10","key":"1365_CR9","doi-asserted-by":"publisher","first-page":"1181","DOI":"10.1016\/j.resuscitation.2009.06.025","volume":"80","author":"JY Tsou","year":"2009","unstructured":"Tsou JY, Chi CH, Hsu RMF, Wu HF, Su FC. Mechanical loading of the low back during cardiopulmonary resuscitation. Resuscitation. 2009;80(10):1181\u20136.","journal-title":"Resuscitation"},{"key":"1365_CR10","unstructured":"Laerdal Medical [Internet]. CPR scoring explained [cited 2023 Jul 24]. Available from: https:\/\/laerdal.com\/gb\/support\/scoring\/."},{"issue":"4","key":"1365_CR11","doi-asserted-by":"publisher","first-page":"332","DOI":"10.1007\/s00420-004-0577-3","volume":"78","author":"AYM Jones","year":"2005","unstructured":"Jones AYM, Lee RYW. Cardiopulmonary resuscitation and back injury in ambulance officers. Int Arch Occup Environ Health. 2005;78(4):332\u20136.","journal-title":"Int Arch Occup Environ Health"},{"issue":"1","key":"1365_CR12","doi-asserted-by":"publisher","first-page":"30","DOI":"10.2344\/anpr-65-01-06","volume":"65","author":"C Cobo-V\u00e1zquez","year":"2018","unstructured":"Cobo-V\u00e1zquez C, De Blas G, Garc\u00eda-Canas P. Del Carmen Gasco-Garc\u00eda M. Electrophysiology of Muscle Fatigue in Cardiopulmonary Resuscitation on Manikin Model. Anesth Prog. 2018;65(1):30\u20137.","journal-title":"Anesth Prog"},{"issue":"5","key":"1365_CR13","doi-asserted-by":"publisher","first-page":"579","DOI":"10.1016\/j.resuscitation.2010.02.006","volume":"81","author":"NP Foo","year":"2010","unstructured":"Foo NP, Chang JH, Lin HJ, Guo HR. Rescuer fatigue and cardiopulmonary resuscitation positions: A randomized controlled crossover trial. Resuscitation. 2010;81(5):579\u201384.","journal-title":"Resuscitation"},{"issue":"16","key":"1365_CR14","doi-asserted-by":"publisher","first-page":"2184","DOI":"10.1001\/jama.1992.03490160054025","volume":"268","author":"Adult Basic Life Support","year":"1992","unstructured":"Adult Basic Life Support. JAMA. 1992;268(16):2184\u201398.","journal-title":"JAMA"},{"issue":"1","key":"1365_CR15","doi-asserted-by":"publisher","first-page":"9","DOI":"10.1186\/s40001-019-0369-6","volume":"24","author":"B Bucki","year":"2019","unstructured":"Bucki B, Waniczek D, Michnik R, Karpe J, Bieniek A, Niczyporuk A, et al. The assessment of the kinematics of the rescuer in continuous chest compression during a 10-min simulation of cardiopulmonary resuscitation. Eur J Med Res. 2019;24(1):9.","journal-title":"Eur J Med Res"},{"issue":"2","key":"1365_CR16","doi-asserted-by":"publisher","first-page":"162","DOI":"10.3109\/10903127.2012.749964","volume":"17","author":"Y Yasuda","year":"2013","unstructured":"Yasuda Y, Kato Y, Sugimoto K, Tanaka S, Tsunoda N, Kumagawa D, et al. Muscles Used for Chest Compression Under Static and Transportation Conditions. Prehospital Emerg Care. 2013;17(2):162\u20139.","journal-title":"Prehospital Emerg Care"},{"issue":"1","key":"1365_CR17","doi-asserted-by":"publisher","first-page":"68","DOI":"10.1080\/10903120500373108","volume":"10","author":"JA Kim","year":"2006","unstructured":"Kim JA, Vogel D, Guimond G, Hostler D, Wang HE, Menegazzi JJ. A Randomized, Controlled Comparison of Cardiopulmonary Resuscitation Performed on the Floor andon a Moving Ambulance Stretcher. Prehospital Emerg Care. 2006;10(1):68\u201370.","journal-title":"Prehospital Emerg Care"},{"key":"1365_CR18","doi-asserted-by":"publisher","first-page":"1","DOI":"10.33151\/ajp.15.3.563","volume":"15","author":"R Chew","year":"2018","unstructured":"Chew R, Price C, Moqadassi H, Talbert S, Hilliar T, Thyer E, et al. Impact of Loading and Transport on Effectiveness of External Chest Compressions \u2013 a Simulation Study. Australasian J Paramedicine. 2018;15:1\u20137.","journal-title":"Australasian J Paramedicine"},{"issue":"5","key":"1365_CR19","doi-asserted-by":"publisher","first-page":"634","DOI":"10.5811\/westjem.2016.6.29949","volume":"17","author":"C Russi","year":"2016","unstructured":"Russi C, Myers L, Kolb L, Lohse C, Hess E, White R. A Comparison of Chest Compression Quality Delivered During On-Scene and Ground Transport Cardiopulmonary Resuscitation. Western J Emerg Med. 2016;17(5):634\u20139.","journal-title":"Western J Emerg Med"},{"issue":"4","key":"1365_CR20","doi-asserted-by":"publisher","first-page":"491","DOI":"10.3109\/10903127.2013.818176","volume":"17","author":"ME Hock Ong","year":"2013","unstructured":"Hock Ong ME, Shin S, Do, Sung SS, Tanaka H, Huei-Ming M, Song KJ, et al. Recommendations on Ambulance Cardiopulmonary Resuscitation in Basic Life Support Systems. Prehospital Emerg Care. 2013;17(4):491\u2013500.","journal-title":"Prehospital Emerg Care"},{"issue":"9","key":"1365_CR21","doi-asserted-by":"publisher","first-page":"1085","DOI":"10.1016\/j.resuscitation.2012.01.033","volume":"83","author":"MC Kurz","year":"2012","unstructured":"Kurz MC, Dante SA, Puckett BJ. Estimating the impact of off-balancing forces upon cardiopulmonary resuscitation during ambulance transport. Resuscitation. 2012;83(9):1085\u20139.","journal-title":"Resuscitation"},{"issue":"1","key":"1365_CR22","doi-asserted-by":"publisher","first-page":"107","DOI":"10.1080\/10903127.2023.2177367","volume":"28","author":"MAC Manoukian","year":"2024","unstructured":"Manoukian MAC, Mumma BE, Wagner JL, Linvill MT, Rose JS. Measuring the Effect of Off-Balancing Vectors on the Delivery of High-Quality CPR during Ambulance Transport: A Proof of Concept Study. Prehospital Emerg Care. 2024;28(1):107\u201313.","journal-title":"Prehospital Emerg Care"},{"issue":"7","key":"1365_CR23","doi-asserted-by":"publisher","first-page":"841","DOI":"10.1016\/j.resuscitation.2010.02.024","volume":"81","author":"TN Chung","year":"2010","unstructured":"Chung TN, Kim SW, Cho YS, Chung SP, Park I, Kim SH. Effect of vehicle speed on the quality of closed-chest compression during ambulance transport. Resuscitation. 2010;81(7):841\u20137.","journal-title":"Resuscitation"},{"issue":"11","key":"1365_CR24","doi-asserted-by":"publisher","first-page":"1","DOI":"10.3310\/hta21110","volume":"21","author":"S Gates","year":"2017","unstructured":"Gates S, Lall R, Quinn T, Deakin CD, Cooke MW, Horton J, et al. Prehospital randomised assessment of a mechanical compression device in out-of-hospital cardiac arrest (PARAMEDIC): a pragmatic, cluster randomised trial and economic evaluation. Health Technol Assess (Rockv). 2017;21(11):1\u2013176.","journal-title":"Health Technol Assess (Rockv)"},{"issue":"9972","key":"1365_CR25","doi-asserted-by":"publisher","first-page":"947","DOI":"10.1016\/S0140-6736(14)61886-9","volume":"385","author":"GD Perkins","year":"2015","unstructured":"Perkins GD, Lall R, Quinn T, Deakin CD, Cooke MW, Horton J, et al. Mechanical versus manual chest compression for out-of-hospital cardiac arrest (PARAMEDIC): a pragmatic, cluster randomised controlled trial. Lancet. 2015;385(9972):947\u201355.","journal-title":"Lancet"},{"issue":"2","key":"1365_CR26","first-page":"171","volume":"76","author":"JTH Kamauzaman Tht, Ngu","year":"2021","unstructured":"Kamauzaman Tht, Ngu JTH, Arithra A, Noh AYM, Siti-Azrin AH, Nor J. Simulation study on quality of CPR between manual chest compression and mechanical chest compression devices performed in ambulance. Med J Malaysia. 2021;76(2):171\u20136.","journal-title":"Med J Malaysia"},{"issue":"1","key":"1365_CR27","doi-asserted-by":"publisher","first-page":"39","DOI":"10.1186\/1757-7241-20-39","volume":"20","author":"M Ong","year":"2012","unstructured":"Ong M, Mackey KE, Zhang Z, Tanaka H, Ma M, Swor R, et al. Mechanical CPR devices compared to manual CPR during out-of-hospital cardiac arrest and ambulance transport: a systematic review. Scand J Trauma Resusc Emerg Med. 2012;20(1):39.","journal-title":"Scand J Trauma Resusc Emerg Med"}],"container-title":["International Journal of Emergency Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s12245-026-01365-0","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12245-026-01365-0.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12245-026-01365-0.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,9,11]],"date-time":"2026-09-11T07:02:13Z","timestamp":1789110133000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1186\/s12245-026-01365-0"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,9,10]]},"references-count":27,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2026,12]]}},"alternative-id":["1365"],"URL":"https:\/\/doi.org\/10.1186\/s12245-026-01365-0","relation":{},"ISSN":["1865-1380"],"issn-type":[{"value":"1865-1380","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,9,10]]},"assertion":[{"value":"11 June 2026","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"1 September 2026","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"10 September 2026","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The study was conducted in a tertiary care university teaching hospital in South India after obtaining approval from the Institutional Ethics Committee (IEC2 454\/2024). Written informed consent was obtained from all participants prior to their inclusion in the study.","order":1,"name":"Ethics","label":"Ethics approval and consent to participate","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"All participants provided consent for the publication of anonymized data.","order":2,"name":"Ethics","label":"Consent for publication","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The authors declare no competing interests.","order":3,"name":"Ethics","label":"Competing interests","group":{"name":"EthicsHeading","label":"Declarations"}}],"article-number":"228"}}