{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,7]],"date-time":"2026-10-07T16:17:17Z","timestamp":1791389837935,"version":"4.3.3"},"reference-count":73,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2019,8,7]],"date-time":"2019-08-07T00:00:00Z","timestamp":1565136000000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"},{"start":{"date-parts":[[2019,8,7]],"date-time":"2019-08-07T00:00:00Z","timestamp":1565136000000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Anesthesiol"],"published-print":{"date-parts":[[2019,12]]},"DOI":"10.1186\/s12871-019-0814-7","type":"journal-article","created":{"date-parts":[[2019,8,7]],"date-time":"2019-08-07T14:03:39Z","timestamp":1565186619000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":51,"title":["Electrical impedance tomography in perioperative medicine: careful respiratory monitoring for tailored interventions"],"prefix":"10.1186","volume":"19","author":[{"given":"Elena","family":"Spinelli","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tommaso","family":"Mauri","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Alberto","family":"Fogagnolo","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Gaetano","family":"Scaramuzzo","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Annalisa","family":"Rundo","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Domenico Luca","family":"Grieco","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Giacomo","family":"Grasselli","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Carlo Alberto","family":"Volta","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-5027-5318","authenticated-orcid":false,"given":"Savino","family":"Spadaro","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2019,8,7]]},"reference":[{"key":"814_CR1","doi-asserted-by":"publisher","first-page":"83","DOI":"10.1136\/thoraxjnl-2016-208357","volume":"72","author":"I Frerichs","year":"2017","unstructured":"Frerichs I, Amato MBP, van Kaam AH, Tingay DG, Zhao Z, Grychtol B, et al. Chest electrical impedance tomography examination, data analysis, terminology, clinical use and recommendations: consensus statement of the TRanslational EIT developmeNt stuDy group. Thorax. 2017;72:83\u201393.","journal-title":"Thorax."},{"key":"814_CR2","doi-asserted-by":"publisher","first-page":"4635","DOI":"10.1039\/c2an35874c","volume":"137","author":"R Bayford","year":"2012","unstructured":"Bayford R, Tizzard A. Bioimpedance imaging: an overview of potential clinical applications. Analyst. 2012;137:4635\u201343.","journal-title":"Analyst."},{"key":"814_CR3","doi-asserted-by":"publisher","first-page":"125","DOI":"10.1088\/0967-3334\/25\/1\/021","volume":"25","author":"WRB Lionheart","year":"2004","unstructured":"Lionheart WRB. EIT reconstruction algorithms: pitfalls, challenges and recent developments. Physiol Meas. 2004;25:125\u201342.","journal-title":"Physiol Meas"},{"key":"814_CR4","doi-asserted-by":"publisher","first-page":"1106","DOI":"10.1109\/10.99074","volume":"38","author":"LF Fuks","year":"1991","unstructured":"Fuks LF, Cheney M, Isaacson D, Gisser DG, Newell JC. Detection and imaging of electric conductivity and permittivity at low frequency. IEEE Trans Biomed Eng. 1991;38:1106\u201310.","journal-title":"IEEE Trans Biomed Eng"},{"issue":"3","key":"814_CR5","doi-asserted-by":"publisher","first-page":"A161","DOI":"10.1088\/0967-3334\/16\/3A\/016","volume":"16","author":"G Hahn","year":"1995","unstructured":"Hahn G, Sipinkov\u00e1 I, Baisch F, Hellige G. Changes in the thoracic impedance distribution under different ventilatory conditions. Physiol Meas. 1995;16(3 Suppl A):A161\u201373.","journal-title":"Physiol Meas"},{"key":"814_CR6","doi-asserted-by":"publisher","first-page":"1262","DOI":"10.1088\/1361-6579\/aa691b","volume":"38","author":"EK Murphy","year":"2017","unstructured":"Murphy EK, Mahara A, Wu X, Halter RJ. Phantom experiments using soft-prior regularization EIT for breast cancer imaging. Physiol Meas. 2017;38:1262\u201377.","journal-title":"Physiol Meas"},{"key":"814_CR7","doi-asserted-by":"publisher","first-page":"892","DOI":"10.1109\/TMI.2016.2640944","volume":"36","author":"EK Murphy","year":"2017","unstructured":"Murphy EK, Mahara A, Halter RJ. Absolute reconstructions using rotational electrical impedance tomography for breast Cancer imaging. IEEE Trans Med Imaging. 2017;36:892\u2013903.","journal-title":"IEEE Trans Med Imaging"},{"key":"814_CR8","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1088\/0967-3334\/37\/1\/1","volume":"37","author":"A Nissinen","year":"2016","unstructured":"Nissinen A, Kaipio JP, Vauhkonen M, Kolehmainen V. Contrast enhancement in EIT imaging of the brain. Physiol Meas. 2016;37:1\u201324.","journal-title":"Physiol Meas"},{"key":"814_CR9","unstructured":"Lionheart WRL, Polydorides N, Borsic A. Electrical Impedance Tomography: Methods, History and Applications p3-64, Editor David Holder Institute of Physics Publishing, 2004. ISBN 0750309520."},{"key":"814_CR10","doi-asserted-by":"publisher","first-page":"792","DOI":"10.1109\/10.844230","volume":"47","author":"JC de Munck","year":"2000","unstructured":"de Munck JC, Faes TJ, Heethaar RM. The boundary element method in the forward and inverse problem of electrical impedance tomography. IEEE Trans Biomed Eng. 2000;47:792\u2013800.","journal-title":"IEEE Trans Biomed Eng"},{"key":"814_CR11","doi-asserted-by":"publisher","first-page":"1083","DOI":"10.1088\/0967-3334\/35\/6\/1083","volume":"35","author":"Z Zhao","year":"2014","unstructured":"Zhao Z, Frerichs I, Pulletz S, M\u00fcller-Lisse U, M\u00f6ller K. The influence of image reconstruction algorithms on linear thorax EIT image analysis of ventilation. Physiol Meas. 2014;35:1083\u201393.","journal-title":"Physiol Meas"},{"key":"814_CR12","doi-asserted-by":"publisher","first-page":"698","DOI":"10.1088\/0967-3334\/37\/6\/698","volume":"37","author":"I Frerichs","year":"2016","unstructured":"Frerichs I, Zhao Z, Becher T, Zabel P, Weiler N, Vogt B. Regional lung function determined by electrical impedance tomography during bronchodilator reversibility testing in patients with asthma. Physiol Meas. 2016;37:698\u2013712.","journal-title":"Physiol Meas"},{"key":"814_CR13","doi-asserted-by":"publisher","first-page":"1154","DOI":"10.1152\/japplphysiol.01630.2011","volume":"113","author":"B Vogt","year":"2012","unstructured":"Vogt B, Pulletz S, Elke G, Zhao Z, Zabel P, Weiler N, et al. Spatial and temporal heterogeneity of regional lung ventilation determined by electrical impedance tomography during pulmonary function testing. J Appl Physiol. 2012;113:1154\u201361.","journal-title":"J Appl Physiol"},{"key":"814_CR14","doi-asserted-by":"publisher","first-page":"L8","DOI":"10.1152\/ajplung.00463.2015","volume":"311","author":"B Vogt","year":"2016","unstructured":"Vogt B, Zhao Z, Zabel P, Weiler N, Frerichs I. Regional lung response to bronchodilator reversibility testing determined by electrical impedance tomography in chronic obstructive pulmonary disease. Am J Physiol Lung Cell Mol Physiol. 2016;311:L8\u201319.","journal-title":"Am J Physiol Lung Cell Mol Physiol"},{"key":"814_CR15","doi-asserted-by":"publisher","first-page":"524","DOI":"10.1213\/ANE.0000000000001424","volume":"124","author":"S Spadaro","year":"2017","unstructured":"Spadaro S, Caramori G, Rizzuto C, Mojoli F, Zani G, Ragazzi R, et al. Expiratory flow limitation as a risk factor for pulmonary complications after major abdominal surgery. Anesth Analg. 2017;124:524\u201330.","journal-title":"Anesth Analg"},{"key":"814_CR16","doi-asserted-by":"crossref","first-page":"69","DOI":"10.1002\/cphy.c080111","volume":"2","author":"G Hedenstierna","year":"2012","unstructured":"Hedenstierna G, Rothen HU. Respiratory function during anesthesia: effects on gas exchange. Compr Physiol. 2012;2:69\u201396.","journal-title":"Compr Physiol"},{"key":"814_CR17","doi-asserted-by":"publisher","first-page":"1156","DOI":"10.1016\/j.bja.2018.03.022","volume":"121","author":"DL Grieco","year":"2018","unstructured":"Grieco DL, Russo A, Roman\u00f2 B, Anzellotti GM, Ciocchetti P, Torrini F, et al. Lung volumes, respiratory mechanics and dynamic strain during general anaesthesia. Br J Anaesth. 2018;121:1156\u201365.","journal-title":"Br J Anaesth"},{"key":"814_CR18","doi-asserted-by":"publisher","first-page":"46","DOI":"10.1097\/ALN.0000000000002693","volume":"131","author":"G Hedenstierna","year":"2019","unstructured":"Hedenstierna G, Tokics L, Scaramuzzo G, Rothen HU, Edmark L, \u00d6hrvik J. Oxygenation impairment during anesthesia: influence of age and body weight. Anesthesiology. 2019;131:46\u201357.","journal-title":"Anesthesiology."},{"key":"814_CR19","doi-asserted-by":"publisher","first-page":"531","DOI":"10.1097\/ALN.0000000000002011","volume":"128","author":"S Spadaro","year":"2018","unstructured":"Spadaro S, Grasso S, Karbing DS, Fogagnolo A, Contoli M, Bollini G, et al. Physiologic evaluation of ventilation perfusion mismatch and respiratory mechanics at different positive end-expiratory pressure in patients undergoing protective one-lung ventilation. Anesthesiology. 2018;128:531\u20138.","journal-title":"Anesthesiology."},{"key":"814_CR20","doi-asserted-by":"publisher","first-page":"855","DOI":"10.1093\/bja\/aew123","volume":"116","author":"S Spadaro","year":"2016","unstructured":"Spadaro S, Karbing DS, Mauri T, Marangoni E, Mojoli F, Valpiani G, et al. Effect of positive end-expiratory pressure on pulmonary shunt and dynamic compliance during abdominal surgery. Br J Anaesth. 2016;116:855\u201361.","journal-title":"Br J Anaesth"},{"key":"814_CR21","doi-asserted-by":"publisher","first-page":"264","DOI":"10.1186\/s13054-018-2199-2","volume":"22","author":"L Gattinoni","year":"2018","unstructured":"Gattinoni L, Quintel M, Marini JJ. Volutrauma and atelectrauma: which is worse? Crit Care. 2018;22:264.","journal-title":"Crit Care"},{"key":"814_CR22","doi-asserted-by":"publisher","first-page":"346","DOI":"10.1164\/rccm.200710-1589OC","volume":"178","author":"D Chiumello","year":"2008","unstructured":"Chiumello D, Carlesso E, Cadringher P, Caironi P, Valenza F, Polli F, et al. Lung stress and strain during mechanical ventilation for acute respiratory distress syndrome. Am J Respir Crit Care Med. 2008;178:346\u201355.","journal-title":"Am J Respir Crit Care Med"},{"key":"814_CR23","doi-asserted-by":"publisher","first-page":"887","DOI":"10.1111\/j.1460-9592.2011.03547.x","volume":"21","author":"S Humphreys","year":"2011","unstructured":"Humphreys S, Pham TMT, Stocker C, Schibler A. The effect of induction of anesthesia and intubation on end-expiratory lung level and regional ventilation distribution in cardiac children. Paediatr Anaesth. 2011;21:887\u201393.","journal-title":"Paediatr Anaesth"},{"key":"814_CR24","doi-asserted-by":"publisher","first-page":"833","DOI":"10.1111\/j.1399-6576.2006.01079.x","volume":"50","author":"K Erlandsson","year":"2006","unstructured":"Erlandsson K, Odenstedt H, Lundin S, Stenqvist O. Positive end-expiratory pressure optimization using electric impedance tomography in morbidly obese patients during laparoscopic gastric bypass surgery. Acta Anaesthesiol Scand. 2006;50:833\u20139.","journal-title":"Acta Anaesthesiol Scand"},{"key":"814_CR25","doi-asserted-by":"publisher","first-page":"1194","DOI":"10.1093\/bja\/aex192","volume":"119","author":"C Nestler","year":"2017","unstructured":"Nestler C, Simon P, Petroff D, Hammerm\u00fcller S, Kamrath D, Wolf S, et al. Individualized positive end-expiratory pressure in obese patients during general anaesthesia: a randomized controlled clinical trial using electrical impedance tomography. Br J Anaesth. 2017;119:1194\u2013205.","journal-title":"Br J Anaesth"},{"key":"814_CR26","doi-asserted-by":"publisher","first-page":"51","DOI":"10.1186\/1471-2253-14-51","volume":"14","author":"MS Schaefer","year":"2014","unstructured":"Schaefer MS, Wania V, Bastin B, Schmalz U, Kienbaum P, Beiderlinden M, et al. Electrical impedance tomography during major open upper abdominal surgery: a pilot-study. BMC Anesthesiol. 2014;14:51.","journal-title":"BMC Anesthesiol"},{"key":"814_CR27","doi-asserted-by":"publisher","first-page":"1070","DOI":"10.1097\/ALN.0000000000002435","volume":"129","author":"SM Pereira","year":"2018","unstructured":"Pereira SM, Tucci MR, Morais CCA, Sim\u00f5es CM, Tonelotto BFF, Pompeo MS, et al. Individual positive end-expiratory pressure settings optimize intraoperative mechanical ventilation and reduce postoperative atelectasis. Anesthesiology. 2018;129:1070\u201381.","journal-title":"Anesthesiology."},{"key":"814_CR28","doi-asserted-by":"publisher","first-page":"76","DOI":"10.1186\/s13613-017-0299-9","volume":"7","author":"N Eronia","year":"2017","unstructured":"Eronia N, Mauri T, Maffezzini E, Gatti S, Bronco A, Alban L, et al. Bedside selection of positive end-expiratory pressure by electrical impedance tomography in hypoxemic patients: a feasibility study. Ann Intensive Care. 2017;7:76.","journal-title":"Ann Intensive Care"},{"key":"814_CR29","doi-asserted-by":"publisher","first-page":"411","DOI":"10.1093\/bja\/aen166","volume":"101","author":"D Steinmann","year":"2008","unstructured":"Steinmann D, Stahl CA, Minner J, Schumann S, Loop T, Kirschbaum A, et al. Electrical impedance tomography to confirm correct placement of double-lumen tube: a feasibility study. Br J Anaesth. 2008;101:411\u20138.","journal-title":"Br J Anaesth"},{"key":"814_CR30","doi-asserted-by":"publisher","first-page":"1900","DOI":"10.1007\/s00134-009-1589-y","volume":"35","author":"Z Zhao","year":"2009","unstructured":"Zhao Z, M\u00f6ller K, Steinmann D, Frerichs I, Guttmann J. Evaluation of an electrical impedance tomography-based global inhomogeneity index for pulmonary ventilation distribution. Intensive Care Med. 2009;35:1900\u20136.","journal-title":"Intensive Care Med"},{"key":"814_CR31","doi-asserted-by":"publisher","first-page":"034003","DOI":"10.1088\/1361-6579\/aaaeb2","volume":"39","author":"Z Zhao","year":"2018","unstructured":"Zhao Z, Wang W, Zhang Z, Xu M, Frerichs I, Wu J, et al. Influence of tidal volume and positive end-expiratory pressure on ventilation distribution and oxygenation during one-lung ventilation. Physiol Meas. 2018;39:034003.","journal-title":"Physiol Meas"},{"key":"814_CR32","doi-asserted-by":"publisher","first-page":"26","DOI":"10.1186\/s13054-017-1931-7","volume":"22","author":"S Spadaro","year":"2018","unstructured":"Spadaro S, Mauri T, B\u00f6hm SH, Scaramuzzo G, Turrini C, Waldmann AD, et al. Variation of poorly ventilated lung units (silent spaces) measured by electrical impedance tomography to dynamically assess recruitment. Crit Care. 2018;22:26.","journal-title":"Crit Care"},{"key":"814_CR33","doi-asserted-by":"publisher","first-page":"221","DOI":"10.1186\/s13054-018-2137-3","volume":"22","author":"C Karagiannidis","year":"2018","unstructured":"Karagiannidis C, Waldmann AD, R\u00f3ka PL, Schreiber T, Strassmann S, Windisch W, et al. Regional expiratory time constants in severe respiratory failure estimated by electrical impedance tomography: a feasibility study. Crit Care. 2018;22:221.","journal-title":"Crit Care"},{"key":"814_CR34","doi-asserted-by":"publisher","first-page":"948","DOI":"10.1016\/j.chest.2018.01.046","volume":"154","author":"D Junhasavasdikul","year":"2018","unstructured":"Junhasavasdikul D, Telias I, Grieco DL, Chen L, Gutierrez CM, Piraino T, et al. Expiratory flow limitation during mechanical ventilation. Chest. 2018;154:948\u201362.","journal-title":"Chest."},{"key":"814_CR35","doi-asserted-by":"publisher","first-page":"128","DOI":"10.1164\/rccm.201808-1504LE","volume":"199","author":"L Chen","year":"2019","unstructured":"Chen L, Del Sorbo L, Fan E, Brochard L. Reply to Koutsoukou: expiratory flow limitation and airway closure in patients with acute respiratory distress syndrome. Am J Respir Crit Care Med. 2019;199:128\u20139.","journal-title":"Am J Respir Crit Care Med"},{"key":"814_CR36","doi-asserted-by":"publisher","first-page":"354","DOI":"10.1111\/aas.12455","volume":"59","author":"H Reinius","year":"2015","unstructured":"Reinius H, Borges JB, Fred\u00e9n F, Jideus L, Camargo EDLB, Amato MBP, et al. Real-time ventilation and perfusion distributions by electrical impedance tomography during one-lung ventilation with capnothorax. Acta Anaesthesiol Scand. 2015;59:354\u201368.","journal-title":"Acta Anaesthesiol Scand"},{"key":"814_CR37","doi-asserted-by":"publisher","first-page":"193","DOI":"10.1016\/S2213-2600(18)30024-9","volume":"6","author":"C Ferrando","year":"2018","unstructured":"Ferrando C, Soro M, Unzueta C, Suarez-Sipmann F, Canet J, Librero J, et al. Individualised perioperative open-lung approach versus standard protective ventilation in abdominal surgery (iPROVE): a randomised controlled trial. Lancet Respir Med. 2018;6:193\u2013203.","journal-title":"Lancet Respir Med"},{"key":"814_CR38","doi-asserted-by":"publisher","first-page":"376","DOI":"10.1016\/j.bja.2017.10.011","volume":"120","author":"R Makaryus","year":"2018","unstructured":"Makaryus R, Miller TE, Gan TJ. Current concepts of fluid management in enhanced recovery pathways. Br J Anaesth. 2018;120:376\u201383.","journal-title":"Br J Anaesth"},{"key":"814_CR39","doi-asserted-by":"publisher","first-page":"820","DOI":"10.1097\/00000542-200210000-00012","volume":"97","author":"TJ Gan","year":"2002","unstructured":"Gan TJ, Soppitt A, Maroof M, el-Moalem H, Robertson KM, Moretti E, et al. Goal-directed intraoperative fluid administration reduces length of hospital stay after major surgery. Anesthesiology. 2002;97:820\u20136.","journal-title":"Anesthesiology."},{"key":"814_CR40","doi-asserted-by":"publisher","first-page":"R118","DOI":"10.1186\/cc9070","volume":"14","author":"J Benes","year":"2010","unstructured":"Benes J, Chytra I, Altmann P, Hluchy M, Kasal E, Svitak R, et al. Intraoperative fluid optimization using stroke volume variation in high risk surgical patients: results of prospective randomized study. Crit Care. 2010;14:R118.","journal-title":"Crit Care"},{"key":"814_CR41","doi-asserted-by":"publisher","first-page":"199","DOI":"10.1186\/cc1489","volume":"6","author":"B Scheer","year":"2002","unstructured":"Scheer B, Perel A, Pfeiffer UJ. Clinical review: complications and risk factors of peripheral arterial catheters used for haemodynamic monitoring in anaesthesia and intensive care medicine. Crit Care. 2002;6:199\u2013204.","journal-title":"Crit Care"},{"key":"814_CR42","doi-asserted-by":"publisher","first-page":"285","DOI":"10.1088\/0967-3334\/21\/2\/308","volume":"21","author":"A Vonk-Noordegraaf","year":"2000","unstructured":"Vonk-Noordegraaf A, Janse A, Marcus JT, Bronzwaer JG, Postmust PE, Faes TJ, et al. Determination of stroke volume by means of electrical impedance tomography. Physiol Meas. 2000;21:285\u201393.","journal-title":"Physiol Meas"},{"key":"814_CR43","doi-asserted-by":"publisher","first-page":"76","DOI":"10.1213\/ANE.0000000000000241","volume":"119","author":"R Pikkemaat","year":"2014","unstructured":"Pikkemaat R, Lundin S, Stenqvist O, Hilgers R-D, Leonhardt S. Recent advances in and limitations of cardiac output monitoring by means of electrical impedance tomography. Anesth Analg. 2014;119:76\u201383.","journal-title":"Anesth Analg"},{"key":"814_CR44","doi-asserted-by":"publisher","first-page":"102","DOI":"10.1213\/ANE.0000000000002271","volume":"126","author":"FJ da Silva Ramos","year":"2018","unstructured":"da Silva Ramos FJ, Hovnanian A, Souza R, Azevedo LCP, Amato MBP, Costa ELV. Estimation of stroke volume and stroke volume changes by electrical impedance tomography. Anesth Analg. 2018;126:102\u201310.","journal-title":"Anesth Analg"},{"key":"814_CR45","doi-asserted-by":"publisher","first-page":"282","DOI":"10.1186\/cc710","volume":"4","author":"F Michard","year":"2000","unstructured":"Michard F, Teboul JL. Using heart-lung interactions to assess fluid responsiveness during mechanical ventilation. Crit Care. 2000;4:282\u20139.","journal-title":"Crit Care"},{"key":"814_CR46","doi-asserted-by":"publisher","first-page":"591","DOI":"10.1093\/bja\/aem062","volume":"98","author":"JC Kubitz","year":"2007","unstructured":"Kubitz JC, Annecke T, Forkl S, Kemming GI, Kronas N, Goetz AE, et al. Validation of pulse contour derived stroke volume variation during modifications of cardiac afterload. Br J Anaesth. 2007;98:591\u20137.","journal-title":"Br J Anaesth"},{"key":"814_CR47","doi-asserted-by":"publisher","first-page":"3001","DOI":"10.1097\/CCM.0b013e31818b31f0","volume":"36","author":"J Marquez","year":"2008","unstructured":"Marquez J, McCurry K, Severyn DA, Pinsky MR. Ability of pulse power, esophageal Doppler, and arterial pulse pressure to estimate rapid changes in stroke volume in humans. Crit Care Med. 2008;36:3001\u20137.","journal-title":"Crit Care Med"},{"key":"814_CR48","doi-asserted-by":"publisher","first-page":"2173","DOI":"10.1097\/CCM.0b013e3182227e65","volume":"39","author":"S Maisch","year":"2011","unstructured":"Maisch S, Bohm SH, Sol\u00e0 J, Goepfert MS, Kubitz JC, Richter HP, et al. Heart-lung interactions measured by electrical impedance tomography. Crit Care Med. 2011;39:2173\u20136.","journal-title":"Crit Care Med"},{"key":"814_CR49","doi-asserted-by":"publisher","first-page":"225","DOI":"10.1152\/japplphysiol.01090.2010","volume":"112","author":"JB Borges","year":"2011","unstructured":"Borges JB, Suarez-Sipmann F, Bohm SH, Tusman G, Melo A, Maripuu E, et al. Regional lung perfusion estimated by electrical impedance tomography in a piglet model of lung collapse. J Appl Physiol. 2011;112:225\u201336.","journal-title":"J Appl Physiol"},{"key":"814_CR50","doi-asserted-by":"publisher","first-page":"e0188313","DOI":"10.1371\/journal.pone.0188313","volume":"12","author":"M Graf","year":"2017","unstructured":"Graf M, Riedel T. Electrical impedance tomography: amplitudes of cardiac related impedance changes in the lung are highly position dependent. PLoS One. 2017;12:e0188313.","journal-title":"PLoS One"},{"key":"814_CR51","doi-asserted-by":"publisher","first-page":"e0191870","DOI":"10.1371\/journal.pone.0191870","volume":"13","author":"F Braun","year":"2018","unstructured":"Braun F, Proen\u00e7a M, Adler A, Riedel T, Thiran J-P, Sol\u00e0 J. Accuracy and reliability of noninvasive stroke volume monitoring via ECG-gated 3D electrical impedance tomography in healthy volunteers. PLoS One. 2018;13:e0191870.","journal-title":"PLoS One"},{"key":"814_CR52","doi-asserted-by":"publisher","first-page":"2200","DOI":"10.1097\/CCM.0b013e318226608b","volume":"39","author":"J-L Teboul","year":"2011","unstructured":"Teboul J-L, Monnet X. Just fastening the belt! Is it the future measure for assessing fluid responsiveness? Crit Care Med. 2011;39:2200\u20131.","journal-title":"Crit Care Med"},{"key":"814_CR53","doi-asserted-by":"crossref","unstructured":"Reychler G, Uribe Rodriguez V, Hickmann CE, Tombal B, Laterre P-F, Feyaerts A, et al. Incentive spirometry and positive expiratory pressure improve ventilation and recruitment in postoperative recovery: a randomized crossover study. Physiother Theory Pract. 2018:1\u20137.","DOI":"10.1080\/09593985.2018.1443185"},{"key":"814_CR54","first-page":"158","volume":"80","author":"J Karsten","year":"2014","unstructured":"Karsten J, Heinze H, Meier T. Impact of PEEP during laparoscopic surgery on early postoperative ventilation distribution visualized by electrical impedance tomography. Minerva Anestesiol. 2014;80:158\u201366.","journal-title":"Minerva Anestesiol"},{"key":"814_CR55","doi-asserted-by":"publisher","first-page":"26","DOI":"10.1111\/anae.12799","volume":"70","author":"D Frasca","year":"2015","unstructured":"Frasca D, Geraud L, Charriere JM, Debaene B, Mimoz O. Comparison of acoustic and impedance methods with mask capnometry to assess respiration rate in obese patients recovering from general anaesthesia. Anaesthesia. 2015;70:26\u201331.","journal-title":"Anaesthesia."},{"key":"814_CR56","doi-asserted-by":"publisher","first-page":"223","DOI":"10.1007\/s10877-014-9596-0","volume":"29","author":"CJ Voscopoulos","year":"2015","unstructured":"Voscopoulos CJ, MacNabb CM, Brayanov J, Qin L, Freeman J, Mullen GJ, et al. The evaluation of a non-invasive respiratory volume monitor in surgical patients undergoing elective surgery with general anesthesia. J Clin Monit Comput. 2015;29:223\u201330.","journal-title":"J Clin Monit Comput"},{"key":"814_CR57","doi-asserted-by":"publisher","first-page":"1042","DOI":"10.1097\/CCM.0b013e31820eb736","volume":"39","author":"H Heinze","year":"2011","unstructured":"Heinze H, Eichler W, Karsten J, Sedemund-Adib B, Heringlake M, Meier T. Functional residual capacity-guided alveolar recruitment strategy after endotracheal suctioning in cardiac surgery patients. Crit Care Med. 2011;39:1042\u20139.","journal-title":"Crit Care Med"},{"key":"814_CR58","doi-asserted-by":"publisher","first-page":"990","DOI":"10.1007\/s00246-014-0886-6","volume":"35","author":"U Krause","year":"2014","unstructured":"Krause U, Becker K, Hahn G, Dittmar J, Ruschewski W, Paul T. Monitoring of regional lung ventilation using electrical impedance tomography after cardiac surgery in infants and children. Pediatr Cardiol. 2014;35:990\u20137.","journal-title":"Pediatr Cardiol"},{"key":"814_CR59","doi-asserted-by":"publisher","first-page":"345","DOI":"10.6061\/clinics\/2013(03)OA10","volume":"68","author":"S Rossi F de","year":"2013","unstructured":"Rossi F de S, Yagui ACZ, Haddad LB, Deutsch AD, Rebello CM. Electrical impedance tomography to evaluate air distribution prior to extubation in very-low-birth-weight infants: a feasibility study. Clinics (Sao Paulo). 2013;68:345\u201350.","journal-title":"Clinics (Sao Paulo)"},{"key":"814_CR60","doi-asserted-by":"publisher","first-page":"316","DOI":"10.1213\/XAA.0000000000000499","volume":"8","author":"P de la Oliva","year":"2017","unstructured":"de la Oliva P, Waldmann AD, B\u00f6hm SH, Verd\u00fa-S\u00e1nchez C, P\u00e9rez-Ferrer A, Alvarez-Rojas E. Bedside breath-wise visualization of bronchospasm by electrical impedance tomography could improve perioperative patient safety: a case report. A A Case Rep. 2017;8:316\u20139.","journal-title":"A A Case Rep"},{"key":"814_CR61","doi-asserted-by":"publisher","first-page":"N107","DOI":"10.1088\/0967-3334\/34\/11\/N107","volume":"34","author":"Z Zhao","year":"2013","unstructured":"Zhao Z, M\u00fcller-Lisse U, Frerichs I, Fischer R, M\u00f6ller K. Regional airway obstruction in cystic fibrosis determined by electrical impedance tomography in comparison with high resolution CT. Physiol Meas. 2013;34:N107\u201314.","journal-title":"Physiol Meas"},{"key":"814_CR62","doi-asserted-by":"publisher","first-page":"237","DOI":"10.1088\/0967-3334\/23\/1\/324","volume":"23","author":"HJ Smit","year":"2002","unstructured":"Smit HJ, Vonk Noordegraaf A, Roeleveld RJ, Bronzwaer JGF, Postmus PE, de Vries PMJM, et al. Epoprostenol-induced pulmonary vasodilatation in patients with pulmonary hypertension measured by electrical impedance tomography. Physiol Meas. 2002;23:237\u201343.","journal-title":"Physiol Meas"},{"key":"814_CR63","doi-asserted-by":"publisher","first-page":"1088","DOI":"10.1007\/s00134-016-4302-y","volume":"42","author":"DL Grieco","year":"2016","unstructured":"Grieco DL, Mura B, Bisanti A, Tagliaferri C, Maviglia R, Antonelli M. Electrical impedance tomography to monitor lung sampling during broncho-alveolar lavage. Intensive Care Med. 2016;42:1088\u20139.","journal-title":"Intensive Care Med"},{"issue":"5 Suppl 1","key":"814_CR64","doi-asserted-by":"publisher","first-page":"557S","DOI":"10.1378\/chest.102.5_Supplement_1.557S","volume":"102","author":"GU Meduri","year":"1992","unstructured":"Meduri GU, Chastre J. The standardization of bronchoscopic techniques for ventilator-associated pneumonia. Chest. 1992;102(5 Suppl 1):557S\u201364S.","journal-title":"Chest."},{"key":"814_CR65","doi-asserted-by":"publisher","first-page":"11","DOI":"10.1186\/s40635-019-0225-6","volume":"7","author":"I Frerichs","year":"2019","unstructured":"Frerichs I, Dargaville PA, Rimensberger PC. Regional pulmonary effects of bronchoalveolar lavage procedure determined by electrical impedance tomography. Intensive Care Med Exp. 2019;7:11.","journal-title":"Intensive Care Med Exp"},{"key":"814_CR66","doi-asserted-by":"publisher","first-page":"1219","DOI":"10.1016\/j.bja.2018.02.030","volume":"120","author":"T Becher","year":"2018","unstructured":"Becher T, Bu\u00dfmeyer M, Lautenschl\u00e4ger I, Sch\u00e4dler D, Weiler N, Frerichs I. Characteristic pattern of pleural effusion in electrical impedance tomography images of critically ill patients. Br J Anaesth. 2018;120:1219\u201328.","journal-title":"Br J Anaesth"},{"key":"814_CR67","doi-asserted-by":"publisher","first-page":"851","DOI":"10.1088\/0967-3334\/32\/7\/S09","volume":"32","author":"M Yasin","year":"2011","unstructured":"Yasin M, B\u00f6hm S, Gaggero PO, Adler A. Evaluation of EIT system performance. Physiol Meas. 2011;32:851\u201365.","journal-title":"Physiol Meas"},{"key":"814_CR68","doi-asserted-by":"publisher","first-page":"975","DOI":"10.1088\/0967-3334\/35\/6\/975","volume":"35","author":"D Bl\u00e4ser","year":"2014","unstructured":"Bl\u00e4ser D, Pulletz S, Becher T, Sch\u00e4dler D, Elke G, Weiler N, et al. Unilateral empyema impacts the assessment of regional lung ventilation by electrical impedance tomography. Physiol Meas. 2014;35:975\u201383.","journal-title":"Physiol Meas"},{"key":"814_CR69","doi-asserted-by":"publisher","first-page":"1420","DOI":"10.1164\/rccm.201303-0539OC","volume":"188","author":"T Yoshida","year":"2013","unstructured":"Yoshida T, Torsani V, Gomes S, De Santis RR, Beraldo MA, Costa ELV, et al. Spontaneous effort causes occult pendelluft during mechanical ventilation. Am J Respir Crit Care Med. 2013;188:1420\u20137.","journal-title":"Am J Respir Crit Care Med"},{"key":"814_CR70","doi-asserted-by":"publisher","first-page":"186","DOI":"10.1513\/AnnalsATS.201306-142OC","volume":"11","author":"SHS Alves","year":"2014","unstructured":"Alves SHS, Amato MBP, Terra RM, Vargas FS, Caruso P. Lung reaeration and reventilation after aspiration of pleural effusions. A study using electrical impedance tomography. Ann Am Thorac Soc. 2014;11:186\u201391.","journal-title":"Ann Am Thorac Soc"},{"key":"814_CR71","doi-asserted-by":"publisher","first-page":"66","DOI":"10.5617\/jeb.3350","volume":"8","author":"V Chitturi","year":"2017","unstructured":"Chitturi V, Nagi F. Spatial resolution in electrical impedance tomography: a topical review. J Electrical Bioimpedance. 2017;8:66\u201378\u201378.","journal-title":"J Electrical Bioimpedance"},{"key":"814_CR72","doi-asserted-by":"publisher","first-page":"30","DOI":"10.1186\/1475-925X-13-30","volume":"13","author":"F Zhang","year":"2014","unstructured":"Zhang F, Li C, Zhang J, Guo H, Wu D. Comparison of quantitative computed tomography analysis and single-indicator thermodilution to measure pulmonary edema in patients with acute respiratory distress syndrome. Biomed Eng Online. 2014;13:30.","journal-title":"Biomed Eng Online"},{"issue":"7","key":"814_CR73","doi-asserted-by":"publisher","first-page":"074006","DOI":"10.1088\/1361-6579\/ab291d","volume":"40","author":"Bart\u0142omiej Grychtol","year":"2019","unstructured":"Grychtol B, Schramel JP, Braun F, Riedel T, Auer U, Mosing M, et al. Thoracic EIT in 3D - experiences and recommendations. Physiol Meas. 2019. https:\/\/doi.org\/10.1088\/1361-6579\/ab291d .","journal-title":"Physiological Measurement"}],"updated-by":[{"DOI":"10.1186\/s12871-019-0840-5","type":"correction","label":"Correction","source":"publisher","updated":{"date-parts":[[2019,9,4]],"date-time":"2019-09-04T00:00:00Z","timestamp":1567555200000}}],"container-title":["BMC Anesthesiology"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1186\/s12871-019-0814-7.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1186\/s12871-019-0814-7\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1186\/s12871-019-0814-7.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,9,25]],"date-time":"2022-09-25T04:32:50Z","timestamp":1664080370000},"score":1,"resource":{"primary":{"URL":"https:\/\/bmcanesthesiol.biomedcentral.com\/articles\/10.1186\/s12871-019-0814-7"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,8,7]]},"references-count":73,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2019,12]]}},"alternative-id":["814"],"URL":"https:\/\/doi.org\/10.1186\/s12871-019-0814-7","relation":{},"ISSN":["1471-2253"],"issn-type":[{"value":"1471-2253","type":"electronic"}],"subject":[],"published":{"date-parts":[[2019,8,7]]},"assertion":[{"value":"20 March 2019","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"29 July 2019","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"7 August 2019","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"4 September 2019","order":4,"name":"change_date","label":"Change Date","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"Correction","order":5,"name":"change_type","label":"Change Type","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"Following publication of the original article [1], the authors reported that one of the co-authors has a mistake in the author name; the middle name and surname are switched. This is the correct information.","order":6,"name":"change_details","label":"Change Details","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"This manuscript is a review, which did not involve research on human subjects. Due to the nature of the project, no Ethics approval was requested.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Not applicable.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"GG received a payment for lectures from Getinge, Draeger Medical, Pfizer, Fisher & Paykel; received a payment for travel\/accommodation\/congress registration support from Getinge and Biotest. TM receiving speaking fees from Draeger outside of the present work. SS received a payment for travel\/accommodation\/congress registration support from Getinge. The other authors declare no conflicts of interests.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"140"}}