{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,8]],"date-time":"2026-10-08T14:27:28Z","timestamp":1791469648398,"version":"4.3.4"},"reference-count":28,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2019,12,1]],"date-time":"2019-12-01T00:00:00Z","timestamp":1575158400000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"},{"start":{"date-parts":[[2019,12,30]],"date-time":"2019-12-30T00:00:00Z","timestamp":1577664000000},"content-version":"vor","delay-in-days":29,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Anesthesiol"],"published-print":{"date-parts":[[2019,12]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:sec><jats:title>Background<\/jats:title><jats:p>This study were designed to investigate the usefulness of the videolaryngoscope-guided insertion technique compared with the standard digital technique for the insertion success rate and insertion conditions of the Proseal\u2122 laryngeal mask airway (PLMA).<\/jats:p><\/jats:sec><jats:sec><jats:title>Methods<\/jats:title><jats:p>Prospective, one hundred and nineteen patients (ASA I\u2013II, aged 18\u201365\u2009yr) were randomly divided for PLMA insertion using the videolaryngoscope-guided technique or the standard digital technique. The PLMA was inserted according to the manufacturer\u2019s instructions in the standard digital technique group. The videolaryngoscope-guided technique was performed a C-MAC\u00ae videolaryngoscope with D-Blade, under gentle videolaryngoscope guidance, the epiglottis was lifted, and the PLMA was advanced until the tip of the distal cuff reached the oesophagus inlet. The number of insertion attempts, insertion time, oropharyngeal leak pressure, leak volume, fiberoptic bronchoscopic view, peak inspiratory pressure, ease of gastric tube placement, hemodynamic changes, visible blood on PLMA and postoperative airway morbidity were recorded.<\/jats:p><\/jats:sec><jats:sec><jats:title>Results<\/jats:title><jats:p>The first-attempt success rate (the primary outcome) was higher in the videolaryngoscope-guided technique than in the standard digital technique (<jats:italic>p<\/jats:italic>\u2009=\u20090.029). The effect size values with 95% confidence interval were 0.19 (0.01\u20130.36) for the first and second attempts, 0.09 (\u2212\u20090.08\u20130.27) for the first and third attempts, and not computed for the second and third attempts by the groups, respectively.<\/jats:p><\/jats:sec><jats:sec><jats:title>Conclusion<\/jats:title><jats:p>Videolaryngoscope-guided insertion technique can be a help in case of difficult positioning of a PLMA and can improve the PLMA performance in some conditions. We suggest that the videolaryngoscope-guided technique may be a useful technique if the digital technique fails<jats:bold>.<\/jats:bold><\/jats:p><\/jats:sec><jats:sec><jats:title>Trial registration<\/jats:title><jats:p><jats:ext-link xmlns:xlink=\"http:\/\/www.w3.org\/1999\/xlink\" ext-link-type=\"uri\" xlink:href=\"http:\/\/clinicaltrials.gov\">ClinicalTrials.gov<\/jats:ext-link>NCT03852589 date of registration: February 22th 2019.<\/jats:p><\/jats:sec>","DOI":"10.1186\/s12871-019-0915-3","type":"journal-article","created":{"date-parts":[[2019,12,30]],"date-time":"2019-12-30T12:02:29Z","timestamp":1577707349000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":19,"title":["Comparison of videolaryngoscope-guided versus standard digital insertion techniques of the ProSeal\u2122 laryngeal mask airway: a prospective randomized study"],"prefix":"10.1186","volume":"19","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-3738-1751","authenticated-orcid":false,"given":"Ulku","family":"Ozgul","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Feray Akgul","family":"Erdil","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mehmet Ali","family":"Erdogan","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Zekine","family":"Begec","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Cemil","family":"Colak","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Aytac","family":"Yucel","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mahmut","family":"Durmus","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2019,12,30]]},"reference":[{"key":"915_CR1","doi-asserted-by":"publisher","first-page":"104","DOI":"10.1097\/00000542-200007000-00019","volume":"93","author":"J Brimacombe","year":"2000","unstructured":"Brimacombe J, Keller C. The ProSeal laryngeal mask airway: a randomized, crossover study with the standard laryngeal mask airway in paralyzed, anesthetized patients. Anesthesiology. 2000;93:104\u20139.","journal-title":"Anesthesiology"},{"key":"915_CR2","doi-asserted-by":"publisher","first-page":"262","DOI":"10.1093\/bja\/85.2.262","volume":"85","author":"C Keller","year":"2000","unstructured":"Keller C, Brimacombe J. Mucosal pressure and oropharyngeal leak pressure with the ProSeal versus laryngeal mask airway in anaesthetized paralysed patients. Br J Anaesth. 2000;85:262\u20136.","journal-title":"Br J Anaesth"},{"key":"915_CR3","doi-asserted-by":"publisher","first-page":"289","DOI":"10.1097\/00000542-200202000-00011","volume":"96","author":"J Brimacombe","year":"2002","unstructured":"Brimacombe J, Keller C, Fullekrug B, Agr\u00f2 F, Rosenblatt W, Dierdorf SF, et al. A multicenter study comparing the ProSeal and classic laryngeal mask airway in anesthetized, nonparalyzed patients. Anesthesiology. 2002;96:289\u201395.","journal-title":"Anesthesiology"},{"key":"915_CR4","doi-asserted-by":"publisher","first-page":"25","DOI":"10.1097\/00000542-200401000-00008","volume":"100","author":"J Brimacombe","year":"2004","unstructured":"Brimacombe J, Keller C, Judd DV. Gum elastic bougie-guided insertion of the ProSeal laryngeal mask airway is superior to the digital and introducer tool techniques. Anesthesiology. 2004;100:25\u20139.","journal-title":"Anesthesiology"},{"key":"915_CR5","doi-asserted-by":"publisher","first-page":"905","DOI":"10.1097\/ALN.0b013e31819b5d40","volume":"110","author":"JW Hwang","year":"2009","unstructured":"Hwang JW, Park HP, Lim YJ, Do SH, Lee SC, Jeon YT. Comparison of two insertion techniques of ProSeal laryngeal mask airway: standard versus 90-degree rotation. Anesthesiology. 2009;110:905\u20137.","journal-title":"Anesthesiology"},{"key":"915_CR6","doi-asserted-by":"publisher","first-page":"617","DOI":"10.1007\/s12630-011-9506-6","volume":"58","author":"HS Chen","year":"2011","unstructured":"Chen HS, Yang SC, Chien CC, Spielberger J, Hung KC, Chung KC. Insertion of the ProSeal\u2122 laryngeal mask airway is more successful with the flexi-slip\u2122 stylet than with the introducer. Can J Anesth. 2011;58:617\u201323.","journal-title":"Can J Anesth"},{"key":"915_CR7","doi-asserted-by":"publisher","first-page":"725","DOI":"10.1007\/s12630-009-9141-7","volume":"56","author":"H El Beheiry","year":"2009","unstructured":"El Beheiry H, Wong J, Nair G, Chinnappa V, Arora G, Morales E, et al. Improved esophageal patency when inserting the ProSeal laryngeal mask airway with an Eschmann tracheal tube introducer. Can J Anesth. 2009;56:725\u201332.","journal-title":"Can J Anesth"},{"key":"915_CR8","doi-asserted-by":"publisher","first-page":"613","DOI":"10.1177\/0310057X0102900609","volume":"29","author":"CK Koay","year":"2001","unstructured":"Koay CK, Yoong CS, Kok P. A randomized trial comparing two laryngeal mask airway insertion techniques. Anaesth Intensive Care. 2001;29:613\u20135.","journal-title":"Anaesth Intensive Care"},{"key":"915_CR9","doi-asserted-by":"publisher","first-page":"76","DOI":"10.5152\/TJAR.2017.67764","volume":"45","author":"M Sorbello","year":"2017","unstructured":"Sorbello M, Petrini F. Supraglottic airway devices: the search for the best insertion technique or the time to change our point of view? Turk J Anaesthesiol Reanim. 2017;45:76\u201382.","journal-title":"Turk J Anaesthesiol Reanim"},{"key":"915_CR10","doi-asserted-by":"publisher","first-page":"1014","DOI":"10.1111\/j.1365-2044.1989.tb09242.x","volume":"44","author":"JJ Lee","year":"1989","unstructured":"Lee JJ. Laryngeal mask and trauma to uvula. Anaesthesia. 1989;44:1014\u20135.","journal-title":"Anaesthesia"},{"key":"915_CR11","doi-asserted-by":"publisher","first-page":"510","DOI":"10.4103\/0970-9185.194774","volume":"32","author":"KB Nalini","year":"2016","unstructured":"Nalini KB, Shivakumar S, Archana S, Sandhya Rani DC, Mohan CV. Comparison of three insertion techniques of ProSeal laryngeal mask airway: a randomized clinical trial. J Anaesthesiol Clin Pharmacol. 2016;32:510\u20134.","journal-title":"J Anaesthesiol Clin Pharmacol"},{"key":"915_CR12","doi-asserted-by":"publisher","first-page":"95","DOI":"10.1007\/s12663-009-0025-8","volume":"8","author":"SN Chandan","year":"2009","unstructured":"Chandan SN, Sharma SM, Raveendra US, Rajendra Prasad B. Fiberoptic assessment of laryngeal mask airway placement: a comparison of blind insertion and insertion with the use of a laryngoscope. J Maxillofac Oral Surg. 2009;8:95\u20138.","journal-title":"J Maxillofac Oral Surg"},{"key":"915_CR13","doi-asserted-by":"publisher","first-page":"1108","DOI":"10.1016\/j.joms.2003.10.014","volume":"62","author":"RL Campbell","year":"2004","unstructured":"Campbell RL, Biddle C, Assudmi N, Campbell JR, Hotchkiss M. Fiberoptic assessment of laryngeal mask airway placement: blind insertion versus direct visual epiglottoscopy. J Maxillofac Oral Surg. 2004;62:1108\u201313.","journal-title":"J Maxillofac Oral Surg"},{"key":"915_CR14","doi-asserted-by":"publisher","first-page":"4","DOI":"10.1186\/s12871-018-0674-6","volume":"19","author":"GW Kim","year":"2019","unstructured":"Kim GW, Kim JY, Kim SJ, Moon YR, Park EJ, Park SY. Conditions for laryngeal mask airway placement in terms of oropharyngeal leak pressure: a comparison between blind insertion and laryngoscope-guided insertion. BMC Anesthesiol. 2019;19:4.","journal-title":"BMC Anesthesiol"},{"key":"915_CR15","doi-asserted-by":"publisher","first-page":"831","DOI":"10.2147\/TCRM.S136221","volume":"13","author":"FS Xue","year":"2017","unstructured":"Xue FS, Li HX, Liu YY, Yang GZ. Current evidence for the use of C-MAC videolaryngoscope in adult airway management: a review of the literature. Ther Clin Risk Manag. 2017;13:831\u201341.","journal-title":"Ther Clin Risk Manag"},{"key":"915_CR16","doi-asserted-by":"crossref","first-page":"381","DOI":"10.4103\/joacp.JOACP_296_17","volume":"34","author":"S Rajan","year":"2018","unstructured":"Rajan S, Kadapamannil D, Barua K, Tosh P, Paul J, Kumar L. Ease of intubation and hemodynamic responses to nasotracheal intubation using C-MAC videolaryngoscope with D blade: a comparison with use of traditional Macintosh laryngoscope. J Anaesthesiol Clin Pharmacol. 2018;34:381\u20135.","journal-title":"J Anaesthesiol Clin Pharmacol"},{"key":"915_CR17","doi-asserted-by":"publisher","first-page":"1063","DOI":"10.1007\/BF03022539","volume":"53","author":"M Micaglio","year":"2006","unstructured":"Micaglio M, Parotto M, Trevisanuto D, Zanardo V, Ori C. Glidescope\/gastric-tube guided technique: a back-up approach for ProSeal LMA insertion. Can J Anesth. 2006;53:1063\u20134.","journal-title":"Can J Anesth"},{"key":"915_CR18","unstructured":"Arslan AK, Colak C. RAY: randomization procedures software, biostatapps.inonu.edu.tr\/RAY\/"},{"key":"915_CR19","unstructured":"LMA. LMA Proseal\u2122 Instruction Manual, 1st ed. San Diego: LMA North America Inc; 2000."},{"key":"915_CR20","doi-asserted-by":"publisher","first-page":"286","DOI":"10.1093\/bja\/82.2.286","volume":"82","author":"C Keller","year":"1999","unstructured":"Keller C, Brimacombe JR, Keller K, Morris R. Comparison of four methods for assessing airway sealing pressure with the laryngeal mask airway in adult patients. Br J Anaesth. 1999;82:286\u20137.","journal-title":"Br J Anaesth"},{"key":"915_CR21","first-page":"457","volume":"76","author":"J Brimacombe","year":"1993","unstructured":"Brimacombe J, Berry A. A proposed fiber-optic scoring system to standardize the assessment of laryngeal mask airway position. Anesth Analg. 1993;76:457.","journal-title":"Anesth Analg"},{"key":"915_CR22","doi-asserted-by":"publisher","first-page":"827","DOI":"10.1093\/bja\/aev371","volume":"115","author":"C Frerk","year":"2015","unstructured":"Frerk C, Mitchell VS, McNarry AF, Mendonca C, Bhagrath R, Patel A, et al. Difficult Airway Society 2015 guidelines for management of unanticipated difficult intubation in adults. Br J Anaesth. 2015;115:827\u201348.","journal-title":"Br J Anaesth"},{"key":"915_CR23","doi-asserted-by":"publisher","first-page":"986","DOI":"10.1111\/j.1365-2044.2012.07167.x","volume":"67","author":"CY Choo","year":"2012","unstructured":"Choo CY, Koay CK, Yoong CS. A randomised controlled trial comparing two insertion techniques for the laryngeal mask airway flexible\u2122 in patients undergoing dental surgery. Anaesthesia. 2012;67:986\u201390.","journal-title":"Anaesthesia"},{"key":"915_CR24","doi-asserted-by":"publisher","first-page":"32","DOI":"10.1016\/j.jclinane.2012.06.004","volume":"25","author":"BZ Chen","year":"2013","unstructured":"Chen BZ, Tan L, Zhang L, Shang YC. Is muscle relaxant necessary in patients undergoing laparoscopic gynecological surgery with a ProSeal LMA\u2122? J Clin Anesth. 2013;25:32\u20135.","journal-title":"J Clin Anesth"},{"key":"915_CR25","doi-asserted-by":"publisher","unstructured":"van Zundert AAJ, Wyssusek KH, Pelecanos A, Roets M, Kumar CM. A prospective randomized comparison of airway seal using the novel vision-guided insertion of LMA-Supreme\u00ae and LMA-Protector\u00ae. J Clin Monit Comput. 2019; https:\/\/doi.org\/10.1007\/s10877-019-00301-3. [Epub ahead of print].","DOI":"10.1007\/s10877-019-00301-3"},{"key":"915_CR26","doi-asserted-by":"publisher","first-page":"300","DOI":"10.1111\/j.1365-2044.1992.tb02168.x","volume":"47","author":"IG Wilson","year":"1992","unstructured":"Wilson IG, Fell D, Robinson SL, Smith G. Cardiovascular responses to insertion of the laryngeal mask. Anaesthesia. 1992;47:300\u20132.","journal-title":"Anaesthesia"},{"key":"915_CR27","first-page":"181","volume":"63","author":"RL Maassen","year":"2012","unstructured":"Maassen RL, Pieters BM, Maathuis B, Serroyen J, Marcus MA, Wouters P, et al. Endotracheal intubation using videolaryngoscopy causes less cardiovascular response compared to classic direct laryngoscopy, in cardiac patients according a standard hospital protocol. Acta Anaesthesiol Belg. 2012;63:181\u20136.","journal-title":"Acta Anaesthesiol Belg"},{"key":"915_CR28","doi-asserted-by":"publisher","first-page":"349","DOI":"10.1213\/ANE.0b013e31823b6748","volume":"114","author":"MR Hernandez","year":"2012","unstructured":"Hernandez MR, Klock PA Jr, Ovassapian A. Evolution of the extraglottic airway: a review of its history, applications, and practical tips for success. Anesth Analg. 2012;114:349\u201368.","journal-title":"Anesth Analg"}],"container-title":["BMC Anesthesiology"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1186\/s12871-019-0915-3.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1186\/s12871-019-0915-3\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1186\/s12871-019-0915-3.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,10,9]],"date-time":"2022-10-09T14:27:16Z","timestamp":1665325636000},"score":1,"resource":{"primary":{"URL":"https:\/\/bmcanesthesiol.biomedcentral.com\/articles\/10.1186\/s12871-019-0915-3"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,12]]},"references-count":28,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2019,12]]}},"alternative-id":["915"],"URL":"https:\/\/doi.org\/10.1186\/s12871-019-0915-3","relation":{},"ISSN":["1471-2253"],"issn-type":[{"value":"1471-2253","type":"electronic"}],"subject":[],"published":{"date-parts":[[2019,12]]},"assertion":[{"value":"7 October 2019","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"12 December 2019","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"30 December 2019","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"This study was approved by the Malatya Clinical Research Ethics Committee (Ref: 2019\/36, February 20, 2019) and registered at(identifier: NCT03852589, principal investigator: Ulku Ozgul, date of registration: February 22, 2019). Written informed consent was obtained from each patient.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Not applicable.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare that they have no competing interests or disclosures.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"244"}}