{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,2,21]],"date-time":"2025-02-21T10:58:45Z","timestamp":1740135525549,"version":"3.37.3"},"reference-count":49,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2020,8,10]],"date-time":"2020-08-10T00:00:00Z","timestamp":1597017600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2020,8,10]],"date-time":"2020-08-10T00:00:00Z","timestamp":1597017600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Anesthesiol"],"published-print":{"date-parts":[[2020,12]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:sec><jats:title>Background<\/jats:title><jats:p>In morbidly obese patients undergoing laparoscopic bariatric surgery, the combination of obesity-related comorbidities, pneumoperitoneum and extreme posture changes constitutes a high risk of perioperative hemodynamic complications. Thus, an advanced hemodynamic monitoring including continuous cardiac index (CI) assessment is desirable. While invasive catheterization may bear technical difficulties, transesophageal echocardiography is contraindicated due to the surgical procedure. Evidence on the clinical reliability of alternative semi- or non-invasive cardiac monitoring devices is limited. The aim was to compare the non-invasive vascular unloading to a semi-invasive pulse contour analysis reference technique for continuous CI measurements in bariatric surgical patients.<\/jats:p><\/jats:sec><jats:sec><jats:title>Methods<\/jats:title><jats:p>This prospective observational study included adult patients scheduled for elective, laparoscopic bariatric surgery after obtained institutional ethics approval and written informed consent. CI measurements were performed using the vascular unloading technique (Nexfin\u00ae) and semi-invasive reference method (FloTrac\u2122). At 10 defined measurement time points, the influence of clinically indicated body posture changes, passive leg raising, fluid bolus administration and pneumoperitoneum was evaluated pre- and intraoperatively. Correlation, Bland-Altman and concordance analyses were performed.<\/jats:p><\/jats:sec><jats:sec><jats:title>Results<\/jats:title><jats:p>Sixty patients (mean BMI 49.2\u2009kg\/m<jats:sup>2<\/jats:sup>) were enrolled into the study and data from 54 patients could be entered in the final analysis. Baseline CI was 3.2\u2009\u00b1\u20090.9 and 3.3\u2009\u00b1\u20090.8\u2009l\/min\/m<jats:sup>2<\/jats:sup>, respectively. Pooled absolute CI values showed a positive correlation (r<jats:sub>s<\/jats:sub>\u00a0=\u20090.76,<jats:italic>P<\/jats:italic>\u00a0&lt;\u20090.001) and mean bias of of \u2212\u20090.16\u2009l\/min\/m<jats:sup>2<\/jats:sup>(limits of agreement: \u2212\u20091.48 to 1.15\u2009l\/min\/m<jats:sup>2<\/jats:sup>) between the two methods. Pooled percentage error was 56.51%, missing the criteria of interchangeability (&lt;\u200930%). Preoperatively, bias ranged from \u2212\u20090.33 to 0.08\u2009l\/min\/m<jats:sup>2<\/jats:sup>with wide limits of agreement. Correlation of CI was best (r<jats:sub>s<\/jats:sub>\u00a0=\u20090.82,<jats:italic>P<\/jats:italic>\u00a0&lt;\u20090.001) and percentage error lowest (46.34%) during anesthesia and after fluid bolus administration. Intraoperatively, bias ranged from \u2212\u20090.34 to \u2212\u20090.03\u2009l\/min\/m<jats:sup>2<\/jats:sup>with wide limits of agreement. CI measurements correlated best during pneumoperitoneum and after fluid bolus administration (r<jats:sub>s<\/jats:sub>\u00a0=\u20090.77,<jats:italic>P<\/jats:italic>\u00a0&lt;\u20090.001; percentage error 35.95%). Trending ability for all 10 measurement points showed a concordance rate of 85.12%, not reaching the predefined Critchley criterion (&gt;\u200992%).<\/jats:p><\/jats:sec><jats:sec><jats:title>Conclusion<\/jats:title><jats:p>Non-invasive as compared to semi-invasive CI measurements did not reach criteria of interchangeability for monitoring absolute and trending values of CI in morbidly obese patients undergoing bariatric surgery.<\/jats:p><\/jats:sec><jats:sec><jats:title>Trial registration<\/jats:title><jats:p>The study was registered retrospectively on June\u00a012, 2017 with the registration number<jats:ext-link xmlns:xlink=\"http:\/\/www.w3.org\/1999\/xlink\" ext-link-type=\"uri\" xlink:href=\"https:\/\/clinicaltrials.gov\/ct2\/show\/NCT03184272\">NCT03184272<\/jats:ext-link>.<\/jats:p><\/jats:sec>","DOI":"10.1186\/s12871-020-01110-x","type":"journal-article","created":{"date-parts":[[2020,8,10]],"date-time":"2020-08-10T18:03:56Z","timestamp":1597082636000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":4,"title":["Perioperative non-invasive versus semi-invasive cardiac index monitoring in patients with bariatric surgery \u2013 a prospective observational study"],"prefix":"10.1186","volume":"20","author":[{"given":"Ulf","family":"Lorenzen","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Markus","family":"Pohlmann","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jonathan","family":"Hansen","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Phil","family":"Klose","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Matthias","family":"Gruenewald","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jochen","family":"Renner","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-4948-1605","authenticated-orcid":false,"given":"Gunnar","family":"Elke","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2020,8,10]]},"reference":[{"key":"1110_CR1","doi-asserted-by":"crossref","first-page":"1822","DOI":"10.1007\/s11695-015-1657-z","volume":"25","author":"L Angrisani","year":"2015","unstructured":"Angrisani L, Santonicola A, Iovino P, Formisano G, Buchwald H, Scopinaro N. Bariatric surgery worldwide 2013. Obes Surg. 2015;25:1822\u201332.","journal-title":"Obes Surg"},{"key":"1110_CR2","doi-asserted-by":"crossref","first-page":"449","DOI":"10.1159\/000355480","volume":"6","author":"M Fried","year":"2013","unstructured":"Fried M, Yumuk V, Oppert JM, Scopinaro N, Torres AJ, Weiner R, Yashkov Y, Fruhbeck G, European Association for the Study of O, International Federation for the Surgery of Obesity - European C. Interdisciplinary European guidelines on metabolic and bariatric surgery. Obes Facts. 2013;6:449\u201368.","journal-title":"Obes Facts"},{"key":"1110_CR3","doi-asserted-by":"crossref","first-page":"402","DOI":"10.1159\/000442721","volume":"8","author":"V Yumuk","year":"2015","unstructured":"Yumuk V, Tsigos C, Fried M, Schindler K, Busetto L, Micic D, Toplak H, Obesity Management Task Force of the European Association for the Study of O. European guidelines for obesity management in adults. Obes Facts. 2015;8:402\u201324.","journal-title":"Obes Facts"},{"key":"1110_CR4","doi-asserted-by":"crossref","first-page":"757","DOI":"10.29271\/jcpsp.2019.08.757","volume":"29","author":"C Kaya","year":"2019","unstructured":"Kaya C, Bilgin S, Cebeci GC, Tomak L. Anaesthetic management of patients undergoing bariatric surgery. J Coll Physicians Surg Pak. 2019;29:757\u201362.","journal-title":"J Coll Physicians Surg Pak"},{"key":"1110_CR5","doi-asserted-by":"crossref","first-page":"103","DOI":"10.1097\/ACO.0000000000000279","volume":"29","author":"A Tsai","year":"2016","unstructured":"Tsai A, Schumann R. Morbid obesity and perioperative complications. Curr Opin Anaesthesiol. 2016;29:103\u20138.","journal-title":"Curr Opin Anaesthesiol"},{"key":"1110_CR6","doi-asserted-by":"crossref","first-page":"165","DOI":"10.1097\/MCC.0000000000000492","volume":"24","author":"B Saugel","year":"2018","unstructured":"Saugel B, Vincent JL. Cardiac output monitoring: how to choose the optimal method for the individual patient. Curr Opin Crit Care. 2018;24:165\u201372.","journal-title":"Curr Opin Crit Care"},{"key":"1110_CR7","first-page":"127","volume":"64","author":"EE Frezza","year":"1998","unstructured":"Frezza EE, Mezghebe H. Indications and complications of arterial catheter use in surgical or medical intensive care units: analysis of 4932 patients. Am Surg. 1998;64:127\u201331.","journal-title":"Am Surg"},{"key":"1110_CR8","first-page":"349","volume":"24","author":"J Penaz","year":"1975","unstructured":"Penaz J. Current photoelectric recording of blood flow through the finger. Cesk Fysiol. 1975;24:349\u201352.","journal-title":"Cesk Fysiol"},{"issue":"Suppl 1","key":"1110_CR9","doi-asserted-by":"crossref","first-page":"S67","DOI":"10.1053\/j.jvca.2019.03.043","volume":"33","author":"TWL Scheeren","year":"2019","unstructured":"Scheeren TWL, Ramsay MAE. New developments in hemodynamic monitoring. J Cardiothorac Vasc Anesth. 2019;33(Suppl 1):S67\u2013s72.","journal-title":"J Cardiothorac Vasc Anesth"},{"key":"1110_CR10","doi-asserted-by":"crossref","first-page":"1449","DOI":"10.1111\/anae.13627","volume":"71","author":"P Schraverus","year":"2016","unstructured":"Schraverus P, Kuijpers MM, Coumou J, Boly CA, Boer C, van Kralingen S. Level of agreement between cardiac output measurements using Nexfin((R)) and thermodilution in morbidly obese patients undergoing laparoscopic surgery. Anaesthesia. 2016;71:1449\u201355.","journal-title":"Anaesthesia"},{"key":"1110_CR11","doi-asserted-by":"crossref","first-page":"767","DOI":"10.1007\/s10877-018-0217-1","volume":"33","author":"T Maeda","year":"2019","unstructured":"Maeda T, Hamaguchi E, Kubo N, Shimokawa A, Kanazawa H, Ohnishi Y. The accuracy and trending ability of cardiac index measured by the fourth-generation FloTrac\/Vigileo system and the Fick method in cardiac surgery patients. J Clin Monit Comput. 2019;33:767\u201376.","journal-title":"J Clin Monit Comput"},{"key":"1110_CR12","doi-asserted-by":"crossref","first-page":"475","DOI":"10.1097\/ALN.0b013e318267ef31","volume":"117","author":"CC Apfel","year":"2012","unstructured":"Apfel CC, Philip BK, Cakmakkaya OS, Shilling A, Shi YY, Leslie JB, Allard M, Turan A, Windle P, Odom-Forren J, Hooper VD, Radke OC, Ruiz J, Kovac A. Who is at risk for postdischarge nausea and vomiting after ambulatory surgery? Anesthesiology. 2012;117:475\u201386.","journal-title":"Anesthesiology"},{"key":"1110_CR13","doi-asserted-by":"crossref","first-page":"H153","DOI":"10.1152\/ajpheart.00839.2014","volume":"308","author":"BE Westerhof","year":"2015","unstructured":"Westerhof BE, Settels JJ, Bos WJ, Westerhof N, Karemaker JM, Wieling W, van Montfrans GA, van Lieshout JJ. Bridging cardiovascular physics, physiology, and clinical practice: Karel H. Wesseling, pioneer of continuous noninvasive hemodynamic monitoring. Am J Physiol Heart Circ Physiol. 2015;308:H153\u20136.","journal-title":"Am J Physiol Heart Circ Physiol"},{"key":"1110_CR14","doi-asserted-by":"crossref","first-page":"1092","DOI":"10.1097\/ALN.0b013e31824f94ed","volume":"116","author":"JR Martina","year":"2012","unstructured":"Martina JR, Westerhof BE, van Goudoever J, de Beaumont EM, Truijen J, Kim YS, Immink RV, Jobsis DA, Hollmann MW, Lahpor JR, de Mol BA, van Lieshout JJ. Noninvasive continuous arterial blood pressure monitoring with Nexfin(R). Anesthesiology. 2012;116:1092\u2013103.","journal-title":"Anesthesiology"},{"key":"1110_CR15","doi-asserted-by":"crossref","first-page":"267","DOI":"10.1007\/s10877-012-9375-8","volume":"26","author":"J Truijen","year":"2012","unstructured":"Truijen J, van Lieshout JJ, Wesselink WA, Westerhof BE. Noninvasive continuous hemodynamic monitoring. J Clin Monit Comput. 2012;26:267\u201378.","journal-title":"J Clin Monit Comput"},{"key":"1110_CR16","doi-asserted-by":"crossref","first-page":"45","DOI":"10.1097\/AIA.0b013e3181b48a1b","volume":"48","author":"B Hashim","year":"2010","unstructured":"Hashim B, Lerner AB. The FloTrac system--measurement of stroke volume and the assessment of dynamic fluid loading. Int Anesthesiol Clin. 2010;48:45\u201356.","journal-title":"Int Anesthesiol Clin"},{"key":"1110_CR17","doi-asserted-by":"crossref","first-page":"403","DOI":"10.2345\/0899-8205(2007)41[403:CAPCOU]2.0.CO;2","volume":"41","author":"B Pratt","year":"2007","unstructured":"Pratt B, Roteliuk L, Hatib F, Frazier J, Wallen RD. Calculating arterial pressure-based cardiac output using a novel measurement and analysis method. Biomed Instrum Technol. 2007;41:403\u201311.","journal-title":"Biomed Instrum Technol"},{"key":"1110_CR18","doi-asserted-by":"crossref","first-page":"523","DOI":"10.1213\/ANE.0b013e3182240054","volume":"113","author":"M Biais","year":"2011","unstructured":"Biais M, Stecken L, Ottolenghi L, Roullet S, Quinart A, Masson F, Sztark F. The ability of pulse pressure variations obtained with CNAP device to predict fluid responsiveness in the operating room. Anesth Analg. 2011;113:523\u20138.","journal-title":"Anesth Analg"},{"key":"1110_CR19","doi-asserted-by":"crossref","first-page":"202","DOI":"10.1093\/bja\/aer394","volume":"108","author":"C Ilies","year":"2012","unstructured":"Ilies C, Bauer M, Berg P, Rosenberg J, Hedderich J, Bein B, Hinz J, Hanss R. Investigation of the agreement of a continuous non-invasive arterial pressure device in comparison with invasive radial artery measurement. Br J Anaesth. 2012;108:202\u201310.","journal-title":"Br J Anaesth"},{"key":"1110_CR20","unstructured":"How can I decide the sample size for a study of agreement between two methods of measurement? https:\/\/www-users.york.ac.uk\/~mb55\/meas\/sizemeth. Accessed 1 May 2020."},{"key":"1110_CR21","doi-asserted-by":"crossref","first-page":"307","DOI":"10.1016\/S0140-6736(86)90837-8","volume":"1","author":"JM Bland","year":"1986","unstructured":"Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet. 1986;1:307\u201310.","journal-title":"Lancet"},{"key":"1110_CR22","doi-asserted-by":"crossref","first-page":"85","DOI":"10.1023\/A:1009982611386","volume":"15","author":"LA Critchley","year":"1999","unstructured":"Critchley LA, Critchley JA. A meta-analysis of studies using bias and precision statistics to compare cardiac output measurement techniques. J Clin Monit Comput. 1999;15:85\u201391.","journal-title":"J Clin Monit Comput"},{"key":"1110_CR23","doi-asserted-by":"crossref","first-page":"1180","DOI":"10.1213\/ANE.0b013e3181f08a5b","volume":"111","author":"LA Critchley","year":"2010","unstructured":"Critchley LA, Lee A, Ho AM. A critical review of the ability of continuous cardiac output monitors to measure trends in cardiac output. Anesth Analg. 2010;111:1180\u201392.","journal-title":"Anesth Analg"},{"key":"1110_CR24","doi-asserted-by":"crossref","first-page":"225","DOI":"10.1097\/00000441-200104000-00003","volume":"321","author":"MA Alpert","year":"2001","unstructured":"Alpert MA. Obesity cardiomyopathy: pathophysiology and evolution of the clinical syndrome. Am J Med Sci. 2001;321:225\u201336.","journal-title":"Am J Med Sci"},{"key":"1110_CR25","doi-asserted-by":"crossref","first-page":"525","DOI":"10.7326\/0003-4819-142-7-200504050-00011","volume":"142","author":"V Snow","year":"2005","unstructured":"Snow V, Barry P, Fitterman N, Qaseem A, Weiss K, Clinical Efficacy Assessment Subcommittee of the American College of P. Pharmacologic and surgical management of obesity in primary care: a clinical practice guideline from the American College of Physicians. Ann Intern Med. 2005;142:525\u201331.","journal-title":"Ann Intern Med"},{"key":"1110_CR26","doi-asserted-by":"crossref","first-page":"562","DOI":"10.1093\/bja\/aeu447","volume":"114","author":"B Saugel","year":"2015","unstructured":"Saugel B, Cecconi M, Wagner JY, Reuter DA. Noninvasive continuous cardiac output monitoring in perioperative and intensive care medicine. Br J Anaesth. 2015;114:562\u201375.","journal-title":"Br J Anaesth"},{"key":"1110_CR27","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1007\/s10877-014-9619-x","volume":"29","author":"JY Wagner","year":"2015","unstructured":"Wagner JY, Saugel B. When should we adopt continuous noninvasive hemodynamic monitoring technologies into clinical routine? J Clin Monit Comput. 2015;29:1\u20133.","journal-title":"J Clin Monit Comput"},{"key":"1110_CR28","doi-asserted-by":"crossref","first-page":"424","DOI":"10.1213\/ANE.0000000000003482","volume":"127","author":"K Maheshwari","year":"2018","unstructured":"Maheshwari K, Khanna S, Bajracharya GR, Makarova N, Riter Q, Raza S, Cywinski JB, Argalious M, Kurz A, Sessler DI. A randomized trial of continuous noninvasive blood pressure monitoring during noncardiac surgery. Anesth Analg. 2018;127:424\u201331.","journal-title":"Anesth Analg"},{"key":"1110_CR29","doi-asserted-by":"crossref","first-page":"716","DOI":"10.1097\/EJA.0000000000000690","volume":"34","author":"AS Meidert","year":"2017","unstructured":"Meidert AS, Nold JS, Hornung R, Paulus AC, Zwissler B, Czerner S. The impact of continuous non-invasive arterial blood pressure monitoring on blood pressure stability during general anaesthesia in orthopaedic patients: a randomised trial. Eur J Anaesthesiol. 2017;34:716\u201322.","journal-title":"Eur J Anaesthesiol"},{"key":"1110_CR30","doi-asserted-by":"crossref","first-page":"1346","DOI":"10.1001\/jama.2017.14172","volume":"318","author":"E Futier","year":"2017","unstructured":"Futier E, Lefrant JY, Guinot PG, Godet T, Lorne E, Cuvillon P, Bertran S, Leone M, Pastene B, Piriou V, Molliex S, Albanese J, Julia JM, Tavernier B, Imhoff E, Bazin JE, Constantin JM, Pereira B, Jaber S, Group IS. Effect of individualized vs standard blood pressure management strategies on postoperative organ dysfunction among high-risk patients undergoing major surgery: a randomized clinical trial. JAMA. 2017;318:1346\u201357.","journal-title":"JAMA"},{"key":"1110_CR31","doi-asserted-by":"crossref","first-page":"139","DOI":"10.1016\/j.bpa.2019.05.008","volume":"33","author":"B Bein","year":"2019","unstructured":"Bein B, Renner J. Best practice & research clinical anaesthesiology: advances in haemodynamic monitoring for the perioperative patient: perioperative cardiac output monitoring. Best Pract Res Clin Anaesthesiol. 2019;33:139\u201353.","journal-title":"Best Pract Res Clin Anaesthesiol"},{"key":"1110_CR32","doi-asserted-by":"crossref","first-page":"171","DOI":"10.1186\/s12871-015-0153-2","volume":"15","author":"O Broch","year":"2015","unstructured":"Broch O, Carbonell J, Ferrando C, Metzner M, Carstens A, Albrecht M, Gruenewald M, Hocker J, Soro M, Steinfath M, Renner J, Bein B. Accuracy of an autocalibrated pulse contour analysis in cardiac surgery patients: a bi-center clinical trial. BMC Anesthesiol. 2015;15:171.","journal-title":"BMC Anesthesiol"},{"key":"1110_CR33","doi-asserted-by":"crossref","first-page":"1119","DOI":"10.1111\/j.1365-2044.2010.06511.x","volume":"65","author":"LW Bogert","year":"2010","unstructured":"Bogert LW, Wesseling KH, Schraa O, Van Lieshout EJ, de Mol BA, van Goudoever J, Westerhof BE, van Lieshout JJ. Pulse contour cardiac output derived from non-invasive arterial pressure in cardiovascular disease. Anaesthesia. 2010;65:1119\u201325.","journal-title":"Anaesthesia"},{"key":"1110_CR34","doi-asserted-by":"crossref","first-page":"377","DOI":"10.1111\/j.1365-2044.2011.07018.x","volume":"67","author":"O Broch","year":"2012","unstructured":"Broch O, Renner J, Gruenewald M, Meybohm P, Schottler J, Caliebe A, Steinfath M, Malbrain M, Bein B. A comparison of the Nexfin(R) and transcardiopulmonary thermodilution to estimate cardiac output during coronary artery surgery. Anaesthesia. 2012;67:377\u201383.","journal-title":"Anaesthesia"},{"key":"1110_CR35","doi-asserted-by":"crossref","first-page":"451081","DOI":"10.1100\/2012\/451081","volume":"2012","author":"O Broch","year":"2012","unstructured":"Broch O, Renner J, Gruenewald M, Meybohm P, Schottler J, Steinfath M, Malbrain M, Bein B. A comparison of third-generation semi-invasive arterial waveform analysis with thermodilution in patients undergoing coronary surgery. ScientificWorldJournal. 2012;2012:451081.","journal-title":"ScientificWorldJournal"},{"key":"1110_CR36","doi-asserted-by":"crossref","first-page":"89","DOI":"10.1016\/j.jclinane.2017.03.029","volume":"39","author":"S Pouwels","year":"2017","unstructured":"Pouwels S, Lascaris B, Nienhuijs SW, Arthur Bouwman R, Buise MP. Validation of the Nexfin(R) non-invasive continuous blood pressure monitoring validated against Riva-Rocci\/Korotkoff in a bariatric patient population. J Clin Anesth. 2017;39:89\u201395.","journal-title":"J Clin Anesth"},{"key":"1110_CR37","doi-asserted-by":"crossref","first-page":"454","DOI":"10.1213\/ANE.0000000000002660","volume":"126","author":"DE Rogge","year":"2018","unstructured":"Rogge DE, Nicklas JY, Haas SA, Reuter DA, Saugel B. Continuous noninvasive arterial pressure monitoring using the vascular unloading technique (CNAP system) in obese patients during laparoscopic bariatric operations. Anesth Analg. 2018;126:454\u201363.","journal-title":"Anesth Analg"},{"key":"1110_CR38","doi-asserted-by":"crossref","first-page":"477","DOI":"10.1213\/ANE.0000000000003943","volume":"128","author":"DE Rogge","year":"2019","unstructured":"Rogge DE, Nicklas JY, Schon G, Grothe O, Haas SA, Reuter DA, Saugel B. Continuous noninvasive arterial pressure monitoring in obese patients during bariatric surgery: an evaluation of the vascular unloading technique (Clearsight system). Anesth Analg. 2019;128:477\u201383.","journal-title":"Anesth Analg"},{"key":"1110_CR39","doi-asserted-by":"crossref","first-page":"861","DOI":"10.1007\/s00540-014-1835-5","volume":"28","author":"JD Tobias","year":"2014","unstructured":"Tobias JD, McKee C, Herz D, Teich S, Sohner P, Rice J, Barry N, Michalsky M. Accuracy of the CNAP monitor, a noninvasive continuous blood pressure device, in providing beat-to-beat blood pressure measurements during bariatric surgery in severely obese adolescents and young adults. J Anesth. 2014;28:861\u20135.","journal-title":"J Anesth"},{"key":"1110_CR40","doi-asserted-by":"crossref","first-page":"562","DOI":"10.1016\/j.jcrc.2015.01.015","volume":"30","author":"A Tejedor","year":"2015","unstructured":"Tejedor A, Rivas E, Rios J, Arismendi E, Martinez-Palli G, Delgado S, Balust J. Accuracy of Vigileo\/Flotrac monitoring system in morbidly obese patients. J Crit Care. 2015;30:562\u20136.","journal-title":"J Crit Care"},{"key":"1110_CR41","doi-asserted-by":"crossref","first-page":"298","DOI":"10.1093\/bja\/aew461","volume":"118","author":"A Joosten","year":"2017","unstructured":"Joosten A, Desebbe O, Suehiro K, Murphy LS, Essiet M, Alexander B, Fischer MO, Barvais L, Van Obbergh L, Maucort-Boulch D, Cannesson M. Accuracy and precision of non-invasive cardiac output monitoring devices in perioperative medicine: a systematic review and meta-analysisdagger. Br J Anaesth. 2017;118:298\u2013310.","journal-title":"Br J Anaesth"},{"key":"1110_CR42","doi-asserted-by":"crossref","first-page":"334","DOI":"10.1097\/MCC.0000000000000422","volume":"23","author":"B Saugel","year":"2017","unstructured":"Saugel B, Vincent JL, Wagner JY. Personalized hemodynamic management. Curr Opin Crit Care. 2017;23:334\u201341.","journal-title":"Curr Opin Crit Care"},{"key":"1110_CR43","doi-asserted-by":"crossref","first-page":"1080","DOI":"10.1097\/ALN.0000000000000226","volume":"120","author":"SH Kim","year":"2014","unstructured":"Kim SH, Lilot M, Sidhu KS, Rinehart J, Yu Z, Canales C, Cannesson M. Accuracy and precision of continuous noninvasive arterial pressure monitoring compared with invasive arterial pressure: a systematic review and meta-analysis. Anesthesiology. 2014;120:1080\u201397.","journal-title":"Anesthesiology"},{"key":"1110_CR44","doi-asserted-by":"crossref","first-page":"603","DOI":"10.1007\/s10877-015-9757-9","volume":"30","author":"K Suehiro","year":"2016","unstructured":"Suehiro K, Joosten A, Murphy LS, Desebbe O, Alexander B, Kim SH, Cannesson M. Accuracy and precision of minimally-invasive cardiac output monitoring in children: a systematic review and meta-analysis. J Clin Monit Comput. 2016;30:603\u201320.","journal-title":"J Clin Monit Comput"},{"key":"1110_CR45","doi-asserted-by":"crossref","first-page":"423","DOI":"10.1007\/s10877-017-0053-8","volume":"32","author":"CA Boly","year":"2018","unstructured":"Boly CA, Schraverus P, van Raalten F, Coumou JW, Boer C, van Kralingen S. Pulse-contour derived cardiac output measurements in morbid obesity: influence of actual, ideal and adjusted bodyweight. J Clin Monit Comput. 2018;32:423\u20138.","journal-title":"J Clin Monit Comput"},{"key":"1110_CR46","doi-asserted-by":"crossref","first-page":"183","DOI":"10.1177\/1358863X07079323","volume":"12","author":"LS Acree","year":"2007","unstructured":"Acree LS, Montgomery PS, Gardner AW. The influence of obesity on arterial compliance in adult men and women. Vasc Med. 2007;12:183\u20138.","journal-title":"Vasc Med"},{"key":"1110_CR47","doi-asserted-by":"crossref","first-page":"923","DOI":"10.1038\/sj.jhh.1002093","volume":"20","author":"CE Clark","year":"2006","unstructured":"Clark CE, Campbell JL, Evans PH, Millward A. Prevalence and clinical implications of the inter-arm blood pressure difference: a systematic review. J Hum Hypertens. 2006;20:923\u201331.","journal-title":"J Hum Hypertens"},{"key":"1110_CR48","doi-asserted-by":"crossref","first-page":"273","DOI":"10.1186\/s13063-018-2620-9","volume":"19","author":"S Funcke","year":"2018","unstructured":"Funcke S, Saugel B, Koch C, Schulte D, Zajonz T, Sander M, Gratarola A, Ball L, Pelosi P, Spadaro S, Ragazzi R, Volta CA, Mencke T, Zitzmann A, Neukirch B, Azparren G, Gine M, Moral V, Pinnschmidt HO, Diaz-Cambronero O, Estelles MJA, Velez ME, Montanes MV, Belda J, Soro M, Puig J, Reuter DA, Haas SA. Individualized, perioperative, hemodynamic goal-directed therapy in major abdominal surgery (iPEGASUS trial): study protocol for a randomized controlled trial. Trials. 2018;19:273.","journal-title":"Trials"},{"key":"1110_CR49","doi-asserted-by":"crossref","first-page":"778","DOI":"10.1097\/00000542-198811000-00027","volume":"69","author":"TS Kurki","year":"1988","unstructured":"Kurki TS, Sanford TJ Jr, Smith NT, Dec-Silver H, Head N. Effects of radial artery cannulation on the function of finger blood pressure and pulse oximeter monitors. Anesthesiology. 1988;69:778\u201382.","journal-title":"Anesthesiology"}],"container-title":["BMC Anesthesiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12871-020-01110-x.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s12871-020-01110-x\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12871-020-01110-x.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,11,6]],"date-time":"2022-11-06T11:48:41Z","timestamp":1667735321000},"score":1,"resource":{"primary":{"URL":"https:\/\/bmcanesthesiol.biomedcentral.com\/articles\/10.1186\/s12871-020-01110-x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,8,10]]},"references-count":49,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2020,12]]}},"alternative-id":["1110"],"URL":"https:\/\/doi.org\/10.1186\/s12871-020-01110-x","relation":{},"ISSN":["1471-2253"],"issn-type":[{"type":"electronic","value":"1471-2253"}],"subject":[],"published":{"date-parts":[[2020,8,10]]},"assertion":[{"value":"28 May 2020","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"27 July 2020","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"10 August 2020","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"Ethical approval was obtained for this study from the ethics committee of the Christian-Albrechts-University Kiel (File number: A 132\/14). Written informed consent was obtained from alll study patients before enrollment. All study procedures were performed in accordance with the Declaration of Helsinki. The study was registered retrospectively on June 12, 2017 at.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Not applicable.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"All authors have provided information on potential conflicts of interests directly or indirectly related to the work submitted. All other authors declared that they have no conflict of interest.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"196"}}