{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,10]],"date-time":"2026-04-10T19:46:33Z","timestamp":1775850393327,"version":"3.50.1"},"reference-count":19,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2020,12,1]],"date-time":"2020-12-01T00:00:00Z","timestamp":1606780800000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"},{"start":{"date-parts":[[2020,12,7]],"date-time":"2020-12-07T00:00:00Z","timestamp":1607299200000},"content-version":"vor","delay-in-days":6,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Anesthesiol"],"published-print":{"date-parts":[[2020,12]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:sec>\n<jats:title>Background<\/jats:title>\n<jats:p>In critically ill patients continuous EEG (cEEG) is recommended in several conditions. Recently, a new wireless EEG headset (CerebAir\u00ae,Nihon-Kohden) is available. It has 8 electrodes, and its positioning seems to be easier than conventional systems.<\/jats:p>\n<jats:p>Aim of this study was to evaluate the feasibility of this device for cEEG monitoring, if positioned by ICU physician.<\/jats:p>\n<\/jats:sec><jats:sec>\n<jats:title>Methods<\/jats:title>\n<jats:p>Neurological patients were divided in two groups according with the admission to Neuro-ICU (Study-group:20 patients) or General-ICU (Control-group:20 patients). In Study group, cEEG was recorded by CerebAir\u00ae assembled by an ICU physician, while in Control group a simplified 8-electrodes-EEG recording positioned by an EEG technician was performed.<\/jats:p>\n<\/jats:sec><jats:sec>\n<jats:title>Results<\/jats:title>\n<jats:p>Time for electrodes applying was shorter in Study-group than in Control-group: 6.2\u2009\u00b1\u20091.1\u2032 vs 10.4\u2009\u00b1\u20092.3\u2032; <jats:italic>p<\/jats:italic>\u00a0&lt;\u20090.0001. Thirty five interventions were necessary to correct artifacts in Study-group and 11 in Control-group. EEG abnormalities with or without epileptic meaning were respectively 7(35%) and 7(35%) in Study-group, and 5(25%) and 9(45%) in Control-group;<jats:italic>p<\/jats:italic>\u00a0&gt;\u20090.05. In Study-group, cEEG was interrupted for risk of skin lesions in 4 cases after 52\u2009\u00b1\u20094\u2009h. cEEG was obtained without EEG technician in all cases in Study-group; quality of EEG was similar.<\/jats:p>\n<\/jats:sec><jats:sec>\n<jats:title>Conclusions<\/jats:title>\n<jats:p>Although several limitations should be considered, this simplified EEG system could be feasible even if EEG technician was not present. It was faster to position if compared with standard techniques, and can be used for continuous EEG monitoring. It could be very useful as part of diagnostic process in an emergency setting.<\/jats:p>\n<\/jats:sec>","DOI":"10.1186\/s12871-020-01213-5","type":"journal-article","created":{"date-parts":[[2020,12,7]],"date-time":"2020-12-07T05:02:54Z","timestamp":1607317374000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":19,"title":["Continuous EEG monitoring by a new simplified wireless headset in intensive care unit"],"prefix":"10.1186","volume":"20","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-5929-120X","authenticated-orcid":false,"given":"Anselmo","family":"Caricato","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Giacomo","family":"Della Marca","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Eleonora","family":"Ioannoni","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Serena","family":"Silva","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Tiziana","family":"Benzi Markushi","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Eleonora","family":"Stival","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Daniele Guerino","family":"Biasucci","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Nicola","family":"Montano","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Camilla","family":"Gelormini","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Isabella","family":"Melchionda","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2020,12,7]]},"reference":[{"issue":"8","key":"1213_CR1","doi-asserted-by":"publisher","first-page":"1337","DOI":"10.1007\/s00134-013-2938-4","volume":"39","author":"J Claassen","year":"2013","unstructured":"Claassen J, Taccone FS, Horn P, et al. Recommendations on the use of EEG monitoring in critically ill patients: consensus statement from the neurointensive care section of the ESICM. Intensive Care Med. 2013;39(8):1337\u201351.","journal-title":"Intensive Care Med"},{"issue":"2","key":"1213_CR2","doi-asserted-by":"publisher","first-page":"87","DOI":"10.1097\/WNP.0000000000000166","volume":"32","author":"ST Herman","year":"2015","unstructured":"Herman ST, Abend NS, Bleck TP, et al. Consensus statement on continuous EEG in critically ill adults and children, part I: indications. J Clin Neurophysiol. 2015;32(2):87\u201395.","journal-title":"J Clin Neurophysiol"},{"issue":"2","key":"1213_CR3","doi-asserted-by":"publisher","first-page":"96","DOI":"10.1097\/WNP.0000000000000165","volume":"32","author":"ST Herman","year":"2015","unstructured":"Herman ST, Abend NS, Bleck TP, et al. Consensus statement on continuous EEG in critically ill adults and children, part II: personnel, technical specifications and clinical practice. J Clin Neurophysiol. 2015;32(2):96\u2013108.","journal-title":"J Clin Neurophysiol"},{"issue":"1","key":"1213_CR4","doi-asserted-by":"publisher","first-page":"75","DOI":"10.1186\/s13054-018-1997-x","volume":"22","author":"A Caricato","year":"2018","unstructured":"Caricato A, Melchionda I, Antonelli M. Continuous electroencephalography monitoring in adults in the intensive care unit. Crit Care. 2018;22(1):75.","journal-title":"Crit Care"},{"key":"1213_CR5","doi-asserted-by":"publisher","first-page":"1743","DOI":"10.1212\/01.WNL.0000125184.88797.62","volume":"62","author":"J Claassen","year":"2004","unstructured":"Claassen J, Mayer SA, Kowalski RG, Emerson RG, Hirsch LJ. Detection of electrographic seizures with continuous EEG monitoring in critically ill patients. Neurology. 2004;62:1743\u20138.","journal-title":"Neurology"},{"key":"1213_CR6","doi-asserted-by":"publisher","first-page":"5","DOI":"10.1016\/j.neucli.2016.09.001","volume":"47","author":"Y Fogang","year":"2017","unstructured":"Fogang Y, Legros B, Depondt C, et al. Yield of repeated intermittent EEG for seizure detection in critically ill adults. Clin Neurophysiol. 2017;47:5\u201312.","journal-title":"Clin Neurophysiol"},{"key":"1213_CR7","doi-asserted-by":"publisher","first-page":"910","DOI":"10.1016\/j.clinph.2011.07.053","volume":"123","author":"WC Ziai","year":"2012","unstructured":"Ziai WC, Schlattman D, Llinas R, et al. Emergent EEG in the emergency department in patients with altered mental states. Clin Neurophysiol. 2012;123:910\u20137.","journal-title":"Clin Neurophysiol"},{"key":"1213_CR8","doi-asserted-by":"publisher","first-page":"181","DOI":"10.1097\/WNP.0000000000000049","volume":"31","author":"AE Tanner","year":"2014","unstructured":"Tanner AE, S\u00e4rkel\u00e4 MO, Virtanen J, et al. Application of subhairline EEG montage in intensive care unit: comparison with full montage. J Clin Neurophysiol. 2014;31:181\u20136.","journal-title":"J Clin Neurophysiol"},{"issue":"1","key":"1213_CR9","doi-asserted-by":"publisher","first-page":"145","DOI":"10.1007\/s13760-016-0663-9","volume":"117","author":"P Vanherpe","year":"2017","unstructured":"Vanherpe P, Schrooten M. Minimal EEG montage with high yield for the detection of status epilepticus in the setting of postanoxic brain damage. Acta Neurol Belg. 2017;117(1):145\u201352.","journal-title":"Acta Neurol Belg"},{"key":"1213_CR10","doi-asserted-by":"publisher","first-page":"100","DOI":"10.1097\/WNP.0b013e3181d649e4","volume":"27","author":"I Karakis","year":"2010","unstructured":"Karakis I, Montouris GD, Otis JAD, et al. A quick and reliable EEG montage for the detection of seizures in the critical care setting. J Clin Neurophysiol. 2010;27:100\u20135.","journal-title":"J Clin Neurophysiol"},{"key":"1213_CR11","doi-asserted-by":"publisher","unstructured":"Meyer M, Fuest S, Krain D, et al. Evaluation of a new wireless technique for continuous electroencephalography monitoring in neurological intensive care patients. J Clin Monit Comput. 2020. https:\/\/doi.org\/10.1007\/s10877-020-00533-8.","DOI":"10.1007\/s10877-020-00533-8"},{"key":"1213_CR12","doi-asserted-by":"publisher","first-page":"217","DOI":"10.1007\/s12028-019-00863-9","volume":"32","author":"S Egawa","year":"2020","unstructured":"Egawa S, Hifumi T, Nakamoto H, et al. Diagnostic reliability of headset-type continuous video EEG monitoring for detection of ICU patterns and NCSE in patients with altered mental status with unknown etiology. Neurocrit Care. 2020;32:217\u201325.","journal-title":"Neurocrit Care"},{"key":"1213_CR13","doi-asserted-by":"publisher","first-page":"329","DOI":"10.1007\/s10877-011-9312-2","volume":"25","author":"R Nitzschke","year":"2011","unstructured":"Nitzschke R, M\u00fcller J, Engelhardt R, et al. Single-channel amplitude integrated EEG recording for the identification of epileptic seizures by nonexpert physicians in the adult acute care setting. J Clin Monit Comput. 2011;25:329\u201337.","journal-title":"J Clin Monit Comput"},{"issue":"Suppl. 1","key":"1213_CR14","doi-asserted-by":"publisher","first-page":"38","DOI":"10.1111\/anae.13739","volume":"72","author":"Z Hajat","year":"2017","unstructured":"Hajat Z, Ahmad N, Andrzejowski J. The role and limitations of EEG-based depth of anaesthesia monitoring in theatres and intensive care. Anaesthesia. 2017;72(Suppl. 1):38\u201347.","journal-title":"Anaesthesia"},{"key":"1213_CR15","doi-asserted-by":"publisher","first-page":"325","DOI":"10.1093\/bja\/aet006","volume":"110","author":"JJ Pandit","year":"2013","unstructured":"Pandit JJ, Cook TM. National Institute for clinical excellence guidance on measuring depth of anaesthesia: limitations of EEG-based technology. Br J Anaesth. 2013;110:325\u20138.","journal-title":"Br J Anaesth"},{"key":"1213_CR16","doi-asserted-by":"publisher","first-page":"1676","DOI":"10.1213\/ane.0b013e318184e9ab","volume":"5","author":"V Cottenceau","year":"2008","unstructured":"Cottenceau V, Petit L, Masson F, et al. The use of bispectral index to monitor barbiturate coma in severely brain-injured patients with refractory intracranial hypertension. Anesth Analg. 2008;5:1676\u201382.","journal-title":"Anesth Analg"},{"key":"1213_CR17","doi-asserted-by":"publisher","first-page":"48","DOI":"10.1016\/j.eplepsyres.2014.10.013","volume":"109","author":"N Dericioglu","year":"2015","unstructured":"Dericioglu N, Yetim E, Bas DF, et al. Nonexpert use of quantitative EEG displays for seizure identification in the adult neuro-intensive care unit. Epilepsy Res. 2015;109:48\u201356.","journal-title":"Epilepsy Res"},{"key":"1213_CR18","doi-asserted-by":"publisher","first-page":"1067","DOI":"10.1007\/s00134-017-4775-3","volume":"43","author":"G Citerio","year":"2017","unstructured":"Citerio G, Patruno A, Beretta S, et al. Implementation of continuous qEEG in two neurointensive care units by intensivists: a feasibility study. Intensive Care Med. 2017;43:1067\u20138.","journal-title":"Intensive Care Med"},{"issue":"11","key":"1213_CR19","doi-asserted-by":"publisher","first-page":"1747","DOI":"10.1007\/s00134-017-4887-9","volume":"43","author":"DG Biasucci","year":"2017","unstructured":"Biasucci DG, Caricato A, Citerio G. qEEG by neurointensivists: research agenda and implications for training. Intensive Care Med. 2017;43(11):1747\u20138.","journal-title":"Intensive Care Med"}],"container-title":["BMC Anesthesiology"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1186\/s12871-020-01213-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1186\/s12871-020-01213-5\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1186\/s12871-020-01213-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2020,12,7]],"date-time":"2020-12-07T05:02:56Z","timestamp":1607317376000},"score":1,"resource":{"primary":{"URL":"https:\/\/bmcanesthesiol.biomedcentral.com\/articles\/10.1186\/s12871-020-01213-5"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,12]]},"references-count":19,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2020,12]]}},"alternative-id":["1213"],"URL":"https:\/\/doi.org\/10.1186\/s12871-020-01213-5","relation":{},"ISSN":["1471-2253"],"issn-type":[{"value":"1471-2253","type":"electronic"}],"subject":[],"published":{"date-parts":[[2020,12]]},"assertion":[{"value":"21 April 2020","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"25 November 2020","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"7 December 2020","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"All procedures performed in studies involving human participants were in accordance with the ethical standards of the institutional and\/or national research committee and with the 1964 Helsinki declaration and its later amendments or comparable ethical standards. Data were managed according with GDPR policy. The study was approved by the Institutional Ethics Committee, Agostino Gemelli University Hospital Foundation IRCCS \u2013 Catholic University of the Sacred Heart Ethics Committee (Prot 42457\/17(1884\/18)ID:1750). Signed informed consent was obtained from all individual participants or from relatives of unconscious patients included in the study.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Not applicable.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"Daniele Guerino Biasucci is an Associate Editor of the journal. The authors declare that they have no other competing interest.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"298"}}