{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,27]],"date-time":"2026-02-27T04:12:54Z","timestamp":1772165574775,"version":"3.50.1"},"reference-count":19,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2021,1,4]],"date-time":"2021-01-04T00:00:00Z","timestamp":1609718400000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"},{"start":{"date-parts":[[2021,1,4]],"date-time":"2021-01-04T00:00:00Z","timestamp":1609718400000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Anesthesiol"],"published-print":{"date-parts":[[2021,12]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Background<\/jats:title>\n                    <jats:p>A fluid warmer can prevent hypothermia during the perioperative period. This study evaluated the heating capabilities of Hotline and Barkey S-line under different flow rates and initial fluid temperatures, as well as after the extension line installation.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>We measured the temperature of a 0.9% sodium chloride solution at the fluid warmer outlet (TProx) and\u00a0the extension line end (TDistal) with three different initial fluid temperatures (room, warm, and cold)\u00a0and two flow rates (250 ml\/hr and 100 mL\/hr).<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>At a 250 ml\/hr flow rate, the TProx and TDistal values were observed to be higher in Hotline than in S-line\u00a0when using room-temperature or cold fluid. Administering of the warm fluid at the same flow rate\u00a0significantly increased the TProx and TDistal values in S-line more than the cold and room-temperature\u00a0fluids. At flow rates of 100 ml\/hr, TDistal values were significantly lower than TProx values in both\u00a0devices regardless of the initial fluid temperature.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>Hotline outperformed S-line for warming fluids at a high flow rate with cold or room-temperature\u00a0fluids. Administering warm fluid in S-line prevented a decrease in the fluid temperature at a high flow\u00a0rate. However, at a low flow rate, the fluid temperature significantly decreased in both devices after\u00a0passing through an extension line.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1186\/s12871-020-01225-1","type":"journal-article","created":{"date-parts":[[2021,1,4]],"date-time":"2021-01-04T07:03:24Z","timestamp":1609743804000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":14,"title":["Influence of flow rate, fluid temperature, and extension line on Hotline and S-line heating capability: an in vitro study"],"prefix":"10.1186","volume":"21","author":[{"given":"Hosu","family":"Kim","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Tae Kyong","family":"Kim","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Sukha","family":"Yoo","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-3738-0081","authenticated-orcid":false,"given":"Jin-Tae","family":"Kim","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2021,1,4]]},"reference":[{"issue":"1","key":"1225_CR1","doi-asserted-by":"publisher","first-page":"25","DOI":"10.2344\/0003-3006-57.1.25","volume":"57","author":"M Diaz","year":"2010","unstructured":"Diaz M, Becker DE. Thermoregulation: physiological and clinical considerations during sedation and general anesthesia. Anesth Prog. 2010;57(1):25\u201332. quiz 33 \u2013 24.","journal-title":"Anesth Prog"},{"issue":"1","key":"1225_CR2","doi-asserted-by":"publisher","first-page":"9","DOI":"10.1080\/23328940.2016.1243509","volume":"4","author":"R Matika","year":"2017","unstructured":"Matika R, Ibrahim M, Patwardhan A. The importance of body temperature: An anesthesiologist\u2019s perspective. Temperature (Austin). 2017;4(1):9\u201312.","journal-title":"Temperature (Austin)"},{"issue":"2","key":"1225_CR3","doi-asserted-by":"publisher","first-page":"318","DOI":"10.1097\/ALN.0b013e31817f6d76","volume":"109","author":"DI Sessler","year":"2008","unstructured":"Sessler DI. Temperature monitoring and perioperative thermoregulation. Anesthesiology. 2008;109(2):318\u201338.","journal-title":"Anesthesiology"},{"issue":"3","key":"1225_CR4","doi-asserted-by":"publisher","first-page":"139","DOI":"10.1152\/advan.00126.2014","volume":"39","author":"EA Tansey","year":"2015","unstructured":"Tansey EA, Johnson CD. Recent advances in thermoregulation. Adv Physiol Educ. 2015;39(3):139\u201348.","journal-title":"Adv Physiol Educ"},{"issue":"5","key":"1225_CR5","doi-asserted-by":"publisher","first-page":"e4","DOI":"10.1053\/j.jvca.2018.04.030","volume":"32","author":"DB Wax","year":"2018","unstructured":"Wax DB, Tyson W, Smith N. Avoidance of Inadvertent Hypothermia With a Fluid-Warming\/Infusion System. J Cardiothorac Vasc Anesth. 2018;32(5):e4\u20135.","journal-title":"J Cardiothorac Vasc Anesth"},{"issue":"4","key":"1225_CR6","doi-asserted-by":"publisher","first-page":"337","DOI":"10.1111\/j.1744-1609.2011.00227.x","volume":"9","author":"S Moola","year":"2011","unstructured":"Moola S, Lockwood C. Effectiveness of strategies for the management and\/or prevention of hypothermia within the adult perioperative environment. Int J Evid Based Healthc. 2011;9(4):337\u201345.","journal-title":"Int J Evid Based Healthc"},{"issue":"5","key":"1225_CR7","doi-asserted-by":"publisher","first-page":"1245","DOI":"10.1016\/j.surg.2014.04.024","volume":"156","author":"AT Billeter","year":"2014","unstructured":"Billeter AT, Hohmann SF, Druen D, Cannon R, Polk HC Jr. Unintentional perioperative hypothermia is associated with severe complications and high mortality in elective operations. Surgery. 2014;156(5):1245\u201352.","journal-title":"Surgery"},{"issue":"3","key":"1225_CR8","doi-asserted-by":"publisher","first-page":"227","DOI":"10.1016\/S0188-4409(01)00272-7","volume":"32","author":"A Flores-Maldonado","year":"2001","unstructured":"Flores-Maldonado A, Medina-Escobedo CE, Rios-Rodriguez HM, Fernandez-Dominguez R. Mild perioperative hypothermia and the risk of wound infection. Arch Med Res. 2001;32(3):227\u201331.","journal-title":"Arch Med Res"},{"issue":"2","key":"1225_CR9","first-page":"155","volume":"67","author":"CB Mahoney","year":"1999","unstructured":"Mahoney CB, Odom J. Maintaining intraoperative normothermia: a meta-analysis of outcomes with costs. AANA J. 1999;67(2):155\u201363.","journal-title":"AANA J"},{"issue":"1","key":"1225_CR10","doi-asserted-by":"publisher","first-page":"7","DOI":"10.1016\/S0020-1383(03)00309-7","volume":"35","author":"BJ Tsuei","year":"2004","unstructured":"Tsuei BJ, Kearney PA. Hypothermia in the trauma patient. Injury. 2004;35(1):7\u201315.","journal-title":"Injury"},{"issue":"14","key":"1225_CR11","doi-asserted-by":"publisher","first-page":"879","DOI":"10.2165\/00007256-200232140-00001","volume":"32","author":"DS Moran","year":"2002","unstructured":"Moran DS, Mendal L. Core temperature measurement: methods and current insights. Sports Med. 2002;32(14):879\u201385.","journal-title":"Sports Med"},{"issue":"1","key":"1225_CR12","doi-asserted-by":"publisher","first-page":"98","DOI":"10.1186\/s12871-018-0565-x","volume":"18","author":"N Zoremba","year":"2018","unstructured":"Zoremba N, Bruells C, Rossaint R, Breuer T. Heating capabilities of small fluid warming systems. BMC Anesthesiol. 2018;18(1):98.","journal-title":"BMC Anesthesiol"},{"key":"1225_CR13","unstructured":"National Institute for Health and Care Excellence. (2008) Hypothermia: prevention and management in adults having surgery. https:\/\/www.nice.org.uk\/guidance\/cg65. Accessed 23 March 2020."},{"issue":"5","key":"1225_CR14","doi-asserted-by":"publisher","first-page":"1105","DOI":"10.1007\/s10877-019-00400-1","volume":"34","author":"X Xu","year":"2020","unstructured":"Xu X, Lian C, Liu Y, Ding H, Lu Y, ShangGuan W. Warming efficacy of Ranger and FT2800 fluid warmer under different room temperatures and flow rates. J Clin Monit Comput. 2020;34(5):1105\u201310.","journal-title":"J Clin Monit Comput"},{"key":"1225_CR15","first-page":"4","volume":"2018","author":"V Thongsukh","year":"2018","unstructured":"Thongsukh V, Kositratana C, Jandonpai A. Effect of Fluid Flow Rate on Efficacy of Fluid Warmer: An In Vitro Experimental Study. Anesthesiol Res Pract. 2018;2018:4.","journal-title":"Anesthesiol Res Pract"},{"issue":"4","key":"1225_CR16","doi-asserted-by":"publisher","first-page":"456","DOI":"10.4097\/kjae.2017.70.4.456","volume":"70","author":"DJ Kim","year":"2017","unstructured":"Kim DJ, Kim SH, So KY, An TH. Mega Acer Kit(R) is more effective for warming the intravenous fluid than Ranger and ThermoSens(R) at 440 ml\/h of infusion rate: an experimental performance study. Korean J Anesthesiol. 2017;70(4):456\u201361.","journal-title":"Korean J Anesthesiol"},{"issue":"1","key":"1225_CR17","first-page":"215","volume":"94","author":"A Macario","year":"2002","unstructured":"Macario A, Dexter F. What are the most important risk factors for a patient\u2019s developing intraoperative hypothermia? Anesth Analg. 2002;94(1):215\u201320. table of contents.","journal-title":"Anesth Analg"},{"issue":"3","key":"1225_CR18","doi-asserted-by":"publisher","first-page":"229","DOI":"10.1097\/SHK.0b013e3181c30f0c","volume":"33","author":"HP Santry","year":"2010","unstructured":"Santry HP, Alam HB. Fluid resuscitation: past, present, and the future. Shock. 2010;33(3):229\u201341.","journal-title":"Shock"},{"issue":"1","key":"1225_CR19","doi-asserted-by":"publisher","first-page":"67","DOI":"10.1007\/BF01872821","volume":"101","author":"NL Gershfeld","year":"1988","unstructured":"Gershfeld NL, Murayama M. Thermal instability of red blood cell membrane bilayers: temperature dependence of hemolysis. J Membr Biol. 1988;101(1):67\u201372.","journal-title":"J Membr Biol"}],"container-title":["BMC Anesthesiology"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1186\/s12871-020-01225-1.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1186\/s12871-020-01225-1\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1186\/s12871-020-01225-1.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,1,4]],"date-time":"2021-01-04T07:03:54Z","timestamp":1609743834000},"score":1,"resource":{"primary":{"URL":"https:\/\/bmcanesthesiol.biomedcentral.com\/articles\/10.1186\/s12871-020-01225-1"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,1,4]]},"references-count":19,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2021,12]]}},"alternative-id":["1225"],"URL":"https:\/\/doi.org\/10.1186\/s12871-020-01225-1","relation":{"has-preprint":[{"id-type":"doi","id":"10.21203\/rs.3.rs-69397\/v1","asserted-by":"object"},{"id-type":"doi","id":"10.21203\/rs.3.rs-69397\/v2","asserted-by":"object"},{"id-type":"doi","id":"10.21203\/rs.3.rs-69397\/v3","asserted-by":"object"}]},"ISSN":["1471-2253"],"issn-type":[{"value":"1471-2253","type":"electronic"}],"subject":[],"published":{"date-parts":[[2021,1,4]]},"assertion":[{"value":"29 August 2020","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"22 December 2020","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"4 January 2021","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"Not applicable.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Not applicable.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare that they have no competing interests.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"1"}}