{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,7,28]],"date-time":"2025-07-28T06:33:54Z","timestamp":1753684434316,"version":"3.37.3"},"reference-count":13,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2022,7,13]],"date-time":"2022-07-13T00:00:00Z","timestamp":1657670400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2022,7,13]],"date-time":"2022-07-13T00:00:00Z","timestamp":1657670400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Anesthesiol"],"published-print":{"date-parts":[[2022,12]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:sec>\n                <jats:title>Background<\/jats:title>\n                <jats:p>The neural integrity monitor (NIM) electromyogram (EMG) endotracheal (ET) tube is a widely used device to monitor neural response through muscle activity. It is helpful in surgical procedures with high risk of damaging delicate structures in the head and neck. This case provides a thorough analysis of an adverse event that was encountered in the operating room, which others can hopefully learn from.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Case presentation<\/jats:title>\n                <jats:p>We are reporting a case in which a patient undergoing hemithyroidectomy had experienced an adverse event using the Medtronic NIM<jats:sup>\u2122<\/jats:sup> EMG endotracheal tube. After successful induction and intubation, confirming the proper positioning of the electrode wires was necessary before the incision could be made. Upon reexamination, the patient suddenly became difficult to ventilate with increased peak airway pressure, decreased tidal volume, and end tidal CO2. This episode lasted approximately 15\u00a0min and the patient\u2019s condition remained stable despite low tidal volumes. The problem was unexpectedly resolved upon deflation of the cuff of the ET tube.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Conclusions<\/jats:title>\n                <jats:p>There are several similar reports of these endotracheal tubes causing obstruction, especially those in which overinflation of the cuff caused cuff herniation and blockage of the Murphy eye and the bevel. It is currently believed that the design of this tube allowed for the obstruction to occur. The patient\u2019s short body habitus may have also been a small contributing factor. The distance that the electrodes must sit within the vocal cords to the tip of the bevel is longer in this type of ET tube compared with a standard ET tube. The distance from the true vocal cords to where the cuff sits in the trachea is also greater in this model NIM EMG tube. There was no confirmation of the exact obstructive process that took place, however, confirming the tube and cuff positioning would have been optimal.<\/jats:p>\n              <\/jats:sec>","DOI":"10.1186\/s12871-022-01762-x","type":"journal-article","created":{"date-parts":[[2022,7,13]],"date-time":"2022-07-13T06:11:00Z","timestamp":1657692660000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":3,"title":["Adverse event using Medtronic NIM\u2122 EMG endotracheal tube on a patient receiving anesthesia for hemithyroidectomy: a case report"],"prefix":"10.1186","volume":"22","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-8371-8402","authenticated-orcid":false,"given":"Emilee","family":"Carpenter","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Lorraine","family":"Norris","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Myriam","family":"Beniamin","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2022,7,13]]},"reference":[{"issue":"3","key":"1762_CR1","doi-asserted-by":"publisher","first-page":"403","DOI":"10.4103\/0970-9185.117052","volume":"29","author":"G Atlas","year":"2013","unstructured":"Atlas G, Lee M. The neural integrity monitor electromyogram tracheal tube: Anesthetic considerations. J Anaesthesiol Clin Pharmacol. 2013;29(3):403\u20134. https:\/\/doi.org\/10.4103\/0970-9185.117052.","journal-title":"J Anaesthesiol Clin Pharmacol"},{"issue":"6","key":"1762_CR2","doi-asserted-by":"publisher","first-page":"588","DOI":"10.1001\/archoto.2012.688","volume":"138","author":"GG Capra","year":"2012","unstructured":"Capra GG, Shah MD, Moore AN,MD, Halsey JD,MD, Lujan WS,MD. E, M.D. Silicone-Based Endotracheal Tube Causing Airway Obstruction and Pneumothorax. Archives of Otolaryngology - Head & Neck Surgery. 2012;138(6):588. https:\/\/www.proquest.com\/scholarly-journals\/silicone-based-endotracheal-tube-causing-airway\/docview\/1022029559\/se-2?accountid=28944.","journal-title":"Archives of Otolaryngology - Head & Neck Surgery"},{"issue":"1","key":"1762_CR3","doi-asserted-by":"publisher","first-page":"2168","DOI":"10.1038\/s41598-021-81744-0","volume":"11","author":"X Ge","year":"2021","unstructured":"Ge X, Huang H, Bai C, et al. The lengths of trachea and main bronchus in Chinese Shanghai population [published correction appears in Sci Rep. 2021 Oct 1;11(1):19917]. Sci Rep. 2021;11(1):2168. https:\/\/doi.org\/10.1038\/s41598-021-81744-0 Published 2021 Jan 26.","journal-title":"Sci Rep"},{"issue":"4","key":"1762_CR4","doi-asserted-by":"publisher","first-page":"777","DOI":"10.1016\/j.atc.2006.08.002","volume":"24","author":"LC Jameson","year":"2006","unstructured":"Jameson LC, Sloan TB. Monitoring of the brain and spinal cord. Anesthesiol Clin. 2006;24(4):777\u201391. https:\/\/doi.org\/10.1016\/j.atc.2006.08.002.","journal-title":"Anesthesiol Clin"},{"issue":"9","key":"1762_CR5","doi-asserted-by":"publisher","first-page":"1935","DOI":"10.1007\/s00268-008-9549-1","volume":"32","author":"IC Lu","year":"2008","unstructured":"Lu IC, Chu KS, Tsai CJ, et al. Optimal depth of NIM EMG endotracheal tube for intraoperative neuromonitoring of the recurrent laryngeal nerve during thyroidectomy. World J Surg. 2008;32(9):1935\u20139. https:\/\/doi.org\/10.1007\/s00268-008-9549-1.","journal-title":"World J Surg"},{"key":"1762_CR6","unstructured":"Maude adverse event report: Medtronic XOMED Inc. Nim Emg - endotracheal tube stimulator, nerve. Acessdata.fda.gov. https:\/\/www.accessdata.fda.gov\/scripts\/cdrh\/cfdocs\/cfMAUDE\/detail.cfm?mdrfoi_id=11574917&pc=ETN. Published March 26 2021. Accessed 12 Feb 2022."},{"key":"1762_CR7","unstructured":"Maude adverse event report: Medtronic XOMED Inc. Nim Emg - endotracheal tube stimulator,nerve. accessdata.fda.gov. https:\/\/www.accessdata.fda.gov\/scripts\/cdrh\/cfdocs\/cfMAUDE\/detail.cfm?mdrfoi_id=11574917&pc=ETN. Published April 2, 2021. Accessed 12 Feb\u00a02022."},{"key":"1762_CR8","unstructured":"Maude adverse event report: Medtronic XOMED Inc.. Nim Emg - endotracheal tube stimulator, nerve. accessdata.fda.gov. https:\/\/www.accessdata.fda.gov\/scripts\/cdrh\/cfdocs\/cfMAUDE\/detail.cfm?mdrfoi__id=2431973&pc=ETN.\u00a0 Published January 30, 2012. Accessed Feb 12 2022."},{"key":"1762_CR9","unstructured":"Maude - manufacturer and User Facility Device experience. accessdata.fda.gov. https:\/\/www.accessdata.fda.gov\/scripts\/cdrh\/cfdocs\/cfMAUDE\/results.cfm. Accessed 12 Feb\u00a02022."},{"key":"1762_CR10","unstructured":"Medtronic NIM\u2122 Standard Reinforced EMG Endotracheal Tube & NIM CONTACT\u2122 Reinforced EMG Endotracheal Tube, Instructions for Use. Jacksonville, FL: Medtronic; 2016:1\u20137."},{"key":"1762_CR11","unstructured":"Medtronic. Nim trivantage EMG tubes - indications, safety, and warnings. Medtronic. https:\/\/www.medtronic.com\/us-en\/healthcare-professionals\/products\/ear-nose-throat\/neuromonitoring\/emg-trivantage-endotracheal-tube\/indications-safety-warnings.html. Accessed 12 Feb 2022."},{"issue":"4","key":"1762_CR12","first-page":"607","volume":"25","author":"N Nawshin","year":"2016","unstructured":"Nawshin N, Mannan S, Begum M, et al. Variation of Length of Trachea in Different Age & Sex Group of Bangladeshi Cadaver. Mymensingh Med J. 2016;25(4):607\u201310.","journal-title":"Mymensingh Med J"},{"issue":"3","key":"1762_CR13","doi-asserted-by":"publisher","first-page":"989","DOI":"10.1213\/ane.0b013e31817ef17","volume":"107","author":"DT Wong","year":"2008","unstructured":"Wong DT, Weng H, Lam E, Song HB, Liu J. Lengthening of the trachea during neck extension: which part of the trachea is stretched? Anesth Analg. 2008;107(3):989\u201393. https:\/\/doi.org\/10.1213\/ane.0b013e31817ef17.","journal-title":"Anesth Analg"}],"container-title":["BMC Anesthesiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12871-022-01762-x.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s12871-022-01762-x\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12871-022-01762-x.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,7,13]],"date-time":"2022-07-13T06:11:19Z","timestamp":1657692679000},"score":1,"resource":{"primary":{"URL":"https:\/\/bmcanesthesiol.biomedcentral.com\/articles\/10.1186\/s12871-022-01762-x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,7,13]]},"references-count":13,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2022,12]]}},"alternative-id":["1762"],"URL":"https:\/\/doi.org\/10.1186\/s12871-022-01762-x","relation":{},"ISSN":["1471-2253"],"issn-type":[{"type":"electronic","value":"1471-2253"}],"subject":[],"published":{"date-parts":[[2022,7,13]]},"assertion":[{"value":"5 April 2022","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"5 July 2022","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"13 July 2022","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Not applicable.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Consent for publication was obtained by the patient as is available in writing upon request.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare that they have no competing interests.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"220"}}