{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,18]],"date-time":"2026-03-18T04:23:33Z","timestamp":1773807813691,"version":"3.50.1"},"reference-count":15,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2024,4,12]],"date-time":"2024-04-12T00:00:00Z","timestamp":1712880000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2024,4,12]],"date-time":"2024-04-12T00:00:00Z","timestamp":1712880000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Anesthesiol"],"abstract":"<jats:title>Abstract<\/jats:title><jats:sec>\n                <jats:title>Background<\/jats:title>\n                <jats:p>The objective of this study was to evaluate a modern combined video laryngoscopy and flexible fiberoptic bronchoscope approach to placement of a double lumen endobronchial tube and further characterize potential strengths and weaknesses of this approach.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Methods<\/jats:title>\n                <jats:p>Retrospective chart review was conducted at our single institution, academic medical center, tertiary-care hospital. Patients aged 18 years of age or older were evaluated who underwent thoracic surgery and one-lung ventilation with placement of a double lumen endobronchial tube using a novel combined video laryngoscopy and flexible fiberoptic bronchoscope approach. No interventions were performed.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Results<\/jats:title>\n                <jats:p>Demographics and induction and intubation documentation were reviewed for 21 patients who underwent thoracic surgery and one-lung ventilation with placement of a double lumen endobronchial tube using a novel combined video laryngoscopy and flexible fiberoptic bronchoscope approach. First pass success using the combined approach was 86% (18\/21). The five patients with an anticipated difficult airway had successful double lumen endobronchial tube placement on the first attempt. There were no instances of desaturation during double lumen endobronchial tube placement. No airway complications related to double lumen endobronchial tube placement were recorded.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Conclusion<\/jats:title>\n                <jats:p>Use of a combined approach employing video laryngoscopy and a flexible fiberoptic bronchoscope may represent a reliable alternative approach to placement of double lumen endobronchial tubes.<\/jats:p>\n              <\/jats:sec>","DOI":"10.1186\/s12871-024-02525-6","type":"journal-article","created":{"date-parts":[[2024,4,12]],"date-time":"2024-04-12T09:02:14Z","timestamp":1712912534000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":3,"title":["A novel combined approach to placement of a double lumen endobronchial tube using a video laryngoscope and fiberoptic bronchoscope: a retrospective chart review"],"prefix":"10.1186","volume":"24","author":[{"given":"Luiz","family":"Maracaja","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Alexandra","family":"Coffield","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"L. Daniela","family":"Smith","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"J. David","family":"Bradshaw","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Amit K.","family":"Saha","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Christopher S.","family":"McLauglin","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"T. Wesley","family":"Templeton","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2024,4,12]]},"reference":[{"key":"2525_CR1","doi-asserted-by":"publisher","first-page":"1968","DOI":"10.1213\/ANE.0000000000002637","volume":"126","author":"SR Collins","year":"2018","unstructured":"Collins SR, Titus BJ, Campos JH, Blank RS. Lung isolation in the patient with a difficult airway. Anesth Analg. 2018;126:1968\u201378.","journal-title":"Anesth Analg"},{"key":"2525_CR2","doi-asserted-by":"publisher","first-page":"71","DOI":"10.1016\/j.thorsurg.2004.09.003","volume":"15","author":"JH Campos","year":"2005","unstructured":"Campos JH. Progress in lung separation. Thorac Surg Clin. 2005;15:71\u201383.","journal-title":"Thorac Surg Clin"},{"key":"2525_CR3","doi-asserted-by":"publisher","first-page":"1485","DOI":"10.1213\/ANE.0000000000004669","volume":"131","author":"S Liu","year":"2020","unstructured":"Liu S, Mao Y, Qiu P, Faridovich KA, Dong Y. Airway rupture caused by double-lumen tubes: a review of 187 cases. Anesth Analg. 2020;131:1485\u201390.","journal-title":"Anesth Analg"},{"key":"2525_CR4","doi-asserted-by":"publisher","first-page":"1259","DOI":"10.1213\/ANE.0000000000000220","volume":"118","author":"R Lenhardt","year":"2014","unstructured":"Lenhardt R, Burkhart MT, Brock GN, Kanchi-Kandadai S, Sharma R, Ak\u00e7a O. Is video laryngoscope-assisted flexible tracheoscope intubation feasible for patients with predicted difficult airway? A prospective, randomized clinical trial. Anesth Analg. 2014;118:1259\u201365.","journal-title":"Anesth Analg"},{"key":"2525_CR5","doi-asserted-by":"publisher","first-page":"1253","DOI":"10.1111\/anae.12322","volume":"68","author":"T Russell","year":"2013","unstructured":"Russell T, Slinger P, Roscoe A, McRae K, Van Rensburg A. A randomized controlled trial comparing the GlideScope(\u00ae) and the Macintosh laryngoscope for double-lumen endobronchial intubation. Anaesthesia. 2013;68:1253\u20138.","journal-title":"Anaesthesia"},{"key":"2525_CR6","doi-asserted-by":"publisher","first-page":"282","DOI":"10.1007\/s12630-009-9243-2","volume":"57","author":"S Bustamante","year":"2010","unstructured":"Bustamante S, Parra-S\u00e1nchez I, Apostolakis J. Sequential rotation to insert a left double-lumen endotracheal tube using the GlideScope. Can J Anaesth. 2010;57:282\u20133.","journal-title":"Can J Anaesth"},{"key":"2525_CR7","doi-asserted-by":"publisher","first-page":"424","DOI":"10.1007\/s12630-012-9671-2","volume":"59","author":"JS Bussi\u00e8res","year":"2012","unstructured":"Bussi\u00e8res JS, Martel F, Somma J, Morin S, Gagn\u00e9 N. A customized stylet for GlideScope\u00ae insertion of double lumen tubes. Can J Anaesth. 2012;59:424\u20135.","journal-title":"Can J Anaesth"},{"key":"2525_CR8","doi-asserted-by":"publisher","first-page":"260","DOI":"10.1186\/s12871-022-01800-8","volume":"22","author":"HT Hsu","year":"2022","unstructured":"Hsu HT, Kuo YW, Ma CW, Su MP, Tseng KY, Li CL, et al. Trachway\u00ae flexible stylet facilitates the correct placement of double-lumen endobronchial tube: a prospective, randomized study. BMC Anesthesiol. 2022;22:260.","journal-title":"BMC Anesthesiol"},{"key":"2525_CR9","doi-asserted-by":"publisher","first-page":"72","DOI":"10.1186\/1471-2253-14-72","volume":"14","author":"HT Hsu","year":"2014","unstructured":"Hsu HT, Chou SH, Chou CY, Tseng KY, Kuo YW, Chen MC, et al. A modified technique to improve the outcome of intubation with a left-sided double-lumen endobronchial tube. BMC Anesthesiol. 2014;14:72.","journal-title":"BMC Anesthesiol"},{"key":"2525_CR10","first-page":"e01198","volume":"14","author":"AR Muncey","year":"2020","unstructured":"Muncey AR, Sweeney J, Hafez O. Placement of a double-lumen endotracheal tube using a combined bronchoscopy and fluoroscopy technique: a case report. Pract. 2020;14:e01198.","journal-title":"Pract"},{"key":"2525_CR11","doi-asserted-by":"publisher","first-page":"5524","DOI":"10.3390\/jcm10235524","volume":"10","author":"K Karczewska","year":"2021","unstructured":"Karczewska K, Bialka S, Smereka J, Cyran M, Nowak-Starz G, Chmielewski J, et al. Efficacy and safety of video-laryngoscopy versus direct laryngoscopy for double-lumen endotracheal intubation: a systematic review and meta-analysis. J Clin Med. 2021;10:5524.","journal-title":"J Clin Med"},{"key":"2525_CR12","doi-asserted-by":"publisher","first-page":"132","DOI":"10.1016\/j.jclinane.2018.12.023","volume":"55","author":"HC Lai","year":"2019","unstructured":"Lai HC, Wu ZF. Easier double-lumen tube placement using real-time video laryngoscopy and wireless video fiberoptic bronchoscopy. J Clin Anesth. 2019;55:132\u20133.","journal-title":"J Clin Anesth"},{"key":"2525_CR13","doi-asserted-by":"publisher","first-page":"920","DOI":"10.1093\/bja\/82.6.920","volume":"82","author":"KF Cheong","year":"1999","unstructured":"Cheong KF, Koh KF. Placement of left-sided double-lumen endobronchial tubes: comparison of clinical and fibreoptic-guided placement. Br J Anaesth. 1999;82:920\u20131.","journal-title":"Br J Anaesth"},{"key":"2525_CR14","doi-asserted-by":"publisher","first-page":"557","DOI":"10.1016\/S0952-8180(98)00081-6","volume":"10","author":"CD Boucek","year":"1998","unstructured":"Boucek CD, Landreneau R, Freeman JA, Strollo D, Bircher NG. A comparison of techniques for placement of double-lumen endobronchial tubes. J Clin Anesth. 1998;10:557\u201360.","journal-title":"J Clin Anesth"},{"key":"2525_CR15","doi-asserted-by":"publisher","first-page":"51","DOI":"10.1186\/s13063-018-3163-9","volume":"20","author":"T Ryu","year":"2019","unstructured":"Ryu T, Kim E, Kim JH, Woo SJ, Roh WS, Byun SH. Comparing the placement of a left-sided double-lumen tube via fiberoptic bronchoscopy guidance versus conventional intubation using a Macintosh laryngoscope, to reduce the incidence of malpositioning: study protocol for a randomized controlled pilot trial. Trials. 2019;20:51.","journal-title":"Trials"}],"container-title":["BMC Anesthesiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12871-024-02525-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s12871-024-02525-6\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12871-024-02525-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,4,12]],"date-time":"2024-04-12T09:04:00Z","timestamp":1712912640000},"score":1,"resource":{"primary":{"URL":"https:\/\/bmcanesthesiol.biomedcentral.com\/articles\/10.1186\/s12871-024-02525-6"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,4,12]]},"references-count":15,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2024,12]]}},"alternative-id":["2525"],"URL":"https:\/\/doi.org\/10.1186\/s12871-024-02525-6","relation":{},"ISSN":["1471-2253"],"issn-type":[{"value":"1471-2253","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,4,12]]},"assertion":[{"value":"6 October 2023","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"5 April 2024","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"12 April 2024","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"This retrospective review was approved by the Advocate \u2013 Wake Forest University School of Medicine Institutional Review Board, and a waiver of informed consent was granted given the retrospective nature of the study. The Approval memo was sent on 1\/27\/2023. IRB#93096.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Not applicable.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"Founder of Pneuomocyte LLC. LM is now a paid consultant for Verathon the manufacturer of the Glidescope. He began his role as a consultant after the conclusion of this study and did not receive any funding during the time in which these cases occurred. LM has not previously been a consultant for Verathon. No other listed authors have any relevant competing interests.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"142"}}