{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,17]],"date-time":"2026-06-17T23:54:38Z","timestamp":1781740478433,"version":"3.54.5"},"reference-count":13,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2024,7,3]],"date-time":"2024-07-03T00:00:00Z","timestamp":1719964800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2024,7,3]],"date-time":"2024-07-03T00:00:00Z","timestamp":1719964800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Anesthesiol"],"abstract":"<jats:title>Abstract<\/jats:title><jats:sec>\n                <jats:title>Background<\/jats:title>\n                <jats:p>This study aimed to evaluate the accuracy of ankle blood pressure measurements in relation to invasive blood pressure in the lateral position.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Methods<\/jats:title>\n                <jats:p>This prospective observational study included adult patients scheduled for elective non-cardiac surgery under general anesthesia in the lateral position. Paired radial artery invasive and ankle noninvasive blood pressure readings were recorded in the lateral position using GE Carescape B650 monitor. The primary outcome was the ability of ankle mean arterial pressure (MAP) to detect hypotension (MAP\u2009&lt;\u200970 mmHg) using area under the receiver operating characteristic curve (AUC) analysis. The secondary outcomes were the ability of ankle systolic blood pressure (SBP) to detect hypertension (SBP\u2009&gt;\u2009140 mmHg)\u00a0as well as bias (invasive measurement \u2013 noninvasive measurement), and agreement between the two methods using the Bland-Altman analysis.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Results<\/jats:title>\n                <jats:p>We analyzed 415 paired readings from 30 patients. The AUC (95% confidence interval [CI]) of ankle MAP for detecting hypotension was 0.88 (0.83\u20130.93). An ankle MAP of \u2264\u200986 mmHg had negative and positive predictive values (95% CI) of 99 (97\u2013100)% and 21 (15\u201329)%, respectively, for detecting hypotension. The AUC (95% CI) of ankle SBP to detect hypertension was 0.83 (0.79\u20130.86) with negative and positive predictive values (95% CI) of 95 (92\u201397)% and 36 (26\u201346)%, respectively, at a cutoff value of &gt;\u2009144 mmHg. The mean bias between the two methods was \u2212\u200912\u2009\u00b1\u200917, 3\u2009\u00b1\u200912, and \u2212\u20091\u2009\u00b1\u200911 mmHg for the SBP, diastolic blood pressure, and MAP, respectively.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Conclusion<\/jats:title>\n                <jats:p>In patients under general anesthesia in the lateral position, ankle blood pressure measurements are not interchangeable with the corresponding invasive measurements. However, an ankle MAP\u2009&gt;\u200986 mmHg can exclude hypotension with 99% accuracy, and an ankle SBP\u2009&lt;\u2009144 mmHg can exclude hypertension with 95% accuracy.<\/jats:p>\n              <\/jats:sec>","DOI":"10.1186\/s12871-024-02595-6","type":"journal-article","created":{"date-parts":[[2024,7,3]],"date-time":"2024-07-03T11:06:19Z","timestamp":1720004779000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":2,"title":["Accuracy of oscillometric noninvasive blood pressure at the ankle in the lateral position during general anesthesia"],"prefix":"10.1186","volume":"24","author":[{"given":"Ahmed","family":"Farag","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Maha","family":"Mostafa","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ahmed","family":"Hasanin","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Lamis","family":"Sobh","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Heba","family":"Raafat","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Gihan","family":"Obayah","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Maha","family":"Youssef","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2024,7,3]]},"reference":[{"key":"2595_CR1","doi-asserted-by":"publisher","first-page":"563","DOI":"10.1016\/j.bja.2019.01.013","volume":"122","author":"DI Sessler","year":"2019","unstructured":"Sessler DI, Bloomstone JA, Aronson S, Berry C, Gan TJ, Kellum JA, et al. Perioperative Quality Initiative consensus statement on intraoperative blood pressure, risk and outcomes for elective surgery. Br J Anaesth. 2019;122:563\u201374.","journal-title":"Br J Anaesth"},{"key":"2595_CR2","doi-asserted-by":"publisher","first-page":"930","DOI":"10.1016\/j.jash.2014.08.014","volume":"8","author":"BS Alpert","year":"2014","unstructured":"Alpert BS, Quinn D, Gallick D. Oscillometric blood pressure: a review for clinicians. J Am Soc Hypertens. 2014;8:930\u20138.","journal-title":"J Am Soc Hypertens"},{"key":"2595_CR3","doi-asserted-by":"publisher","first-page":"364","DOI":"10.1097\/MBP.0000000000000546","volume":"26","author":"M Mostafa","year":"2021","unstructured":"Mostafa M, Hasanin AM, Elsayed OS, Mostafa MM, Sarhan K. Accuracy of oscillometric blood pressure measurement at both arms in the lateral position. Blood Press Monit. 2021;26:364\u201372.","journal-title":"Blood Press Monit"},{"key":"2595_CR4","doi-asserted-by":"publisher","first-page":"1207","DOI":"10.1097\/CCM.0b013e31823dae42","volume":"40","author":"K Lakhal","year":"2012","unstructured":"Lakhal K, Macq C, Ehrmann S, Boulain T, Capdevila X. Noninvasive monitoring of blood pressure in the critically ill. Crit Care Med. 2012;40:1207\u201313.","journal-title":"Crit Care Med"},{"key":"2595_CR5","doi-asserted-by":"publisher","first-page":"571","DOI":"10.1080\/10543400701329422","volume":"17","author":"JM Bland","year":"2007","unstructured":"Bland JM, Altman DG. Agreement between methods of measurement with multiple observations per individual. J Biopharm Stat. 2007;17:571\u201382.","journal-title":"J Biopharm Stat"},{"key":"2595_CR6","doi-asserted-by":"publisher","first-page":"459","DOI":"10.1097\/HJH.0000000000002039","volume":"37","author":"GS Stergiou","year":"2019","unstructured":"Stergiou GS, Palatini P, Asmar R, Ioannidis JP, Kollias A, Lacy P, et al. Recommendations and practical Guidance for performing and reporting validation studies according to the Universal Standard for the validation of blood pressuremeasuring devices by theAssociation for the Advancement ofMedical Instrumentation\/European Socie. J Hypertens. 2019;37:459\u201366.","journal-title":"J Hypertens"},{"key":"2595_CR7","doi-asserted-by":"publisher","first-page":"23","DOI":"10.1097\/MBP.0b013e3283360e98","volume":"15","author":"E O\u2019Brien","year":"2010","unstructured":"O\u2019Brien E, Atkins N, Stergiou G, Karpettas N, Parati G, Asmar R, et al. European Society of Hypertension International Protocol revision 2010 for the validation of blood pressure measuring devices in adults. Blood Press Monit. 2010;15:23\u201338.","journal-title":"Blood Press Monit"},{"key":"2595_CR8","doi-asserted-by":"publisher","first-page":"1180","DOI":"10.1213\/ANE.0b013e3181f08a5b","volume":"111","author":"LA Critchley","year":"2010","unstructured":"Critchley LA, Lee A, Ho AMH. A critical review of the ability of continuous cardiac output monitors to measure trends in cardiac output. Anesth Analg. 2010;111:1180\u201392.","journal-title":"Anesth Analg"},{"key":"2595_CR9","doi-asserted-by":"publisher","first-page":"1350","DOI":"10.1097\/CCM.0000000000005945","volume":"51","author":"K Lakhal","year":"2023","unstructured":"Lakhal K, Dauvergne JE, Kamel T, Messet-Charriere H, Jacquier S, Robert-Edan V, et al. Noninvasive monitoring of arterial pressure: Finger or Lower Leg as Alternatives to the Upper Arm: a prospective study in three ICUs. Crit Care Med. 2023;51:1350\u201362.","journal-title":"Crit Care Med"},{"key":"2595_CR10","doi-asserted-by":"publisher","first-page":"179","DOI":"10.1097\/ALN.0000000000003636","volume":"134","author":"R Schumann","year":"2021","unstructured":"Schumann R, Meidert AS, Bonney I, Koutentis C, Wesselink W, Kouz K, et al. Intraoperative blood pressure monitoring in obese patients: arterial catheter, Finger Cuff, and Oscillometry. Anesthesiology. 2021;134:179\u201388.","journal-title":"Anesthesiology"},{"key":"2595_CR11","doi-asserted-by":"crossref","unstructured":"Gamal RM, Mostafa M, Hasanin AM, Khedr SA, Abdelgalil AS, Elshal MM. Evaluation of the accuracy of oscillometric non-invasive blood pressure measurement at the ankle in children during general anesthesia. J Clin Monit Comput. 2023.","DOI":"10.1007\/s10877-023-01025-1"},{"key":"2595_CR12","doi-asserted-by":"publisher","first-page":"973","DOI":"10.1097\/ALN.0b013e3182330286","volume":"115","author":"DB Wax","year":"2011","unstructured":"Wax DB, Lin HM, Leibowitz AB. Invasive and concomitant noninvasive intraoperative blood pressure monitoring: observed differences in measurements and associated therapeutic interventions. Anesthesiology. 2011;115:973\u20138.","journal-title":"Anesthesiology"},{"key":"2595_CR13","doi-asserted-by":"publisher","first-page":"470","DOI":"10.1111\/anae.13421","volume":"71","author":"MR Checketts","year":"2016","unstructured":"Checketts MR. AAGBI recommendations for standards of monitoring during anaesthesia and recovery 2015. Anaesthesia. 2016;71:470\u20131.","journal-title":"Anaesthesia"}],"container-title":["BMC Anesthesiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12871-024-02595-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s12871-024-02595-6\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12871-024-02595-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,7,3]],"date-time":"2024-07-03T11:06:22Z","timestamp":1720004782000},"score":1,"resource":{"primary":{"URL":"https:\/\/bmcanesthesiol.biomedcentral.com\/articles\/10.1186\/s12871-024-02595-6"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,7,3]]},"references-count":13,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2024,12]]}},"alternative-id":["2595"],"URL":"https:\/\/doi.org\/10.1186\/s12871-024-02595-6","relation":{},"ISSN":["1471-2253"],"issn-type":[{"value":"1471-2253","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,7,3]]},"assertion":[{"value":"23 January 2024","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"11 June 2024","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"3 July 2024","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Ethical approval from Cairo University\u2019s Research Ethics Committee was obtained (MD-359-2022). Written informed consents were obtained from participants before inclusion.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical approval"}},{"value":"Not applicable.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare that they have no competing interests.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"221"}}